| Plan Review Stops For Permit 06080861 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-09-23 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-05 |
Time |
15:25 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-01-05 |
Time |
15:19 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-16 |
Time |
16:31 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-10-16 |
Time |
16:31 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-01 |
Time |
15:40 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-01 |
Time |
15:16 |
Sent To |
M |
|
| Notes |
| 2006-09-01 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1) PROVIDE A PANEL SCHEDULE FOR THE | | | EMERGENCY/GENERATOR PANEL(S). CALCULATE | | | THE LOADS FOR THE INDIVIDUAL PANELS AS | | | IT APPEARS TWO PANELS ARE BEING FED FROM | | | THE ATS. PLEASE CLARIFY. | | | | | | 2} THERE MUST BE A DISCONNECT FROM THE | | | GENERATOR WHERE THE CONDUCTORS ENTER THE | | | BUILDING. IF ALL DISCONNECTS CANNOT BE | | | GROUPED PER 230.72, SEE THAT ALL | | | ARTICLES FROM 225.31 THROUGH 225.39, ARE | | | COMPLIED WITH. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-03 |
Time |
15:49 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-05-03 |
Time |
15:49 |
Sent To |
PC |
|
| Notes |
| 2007-05-03 16:02:34 | REVISION: CHANGE LAYOUT AND LENGTH OF PIPE. | | | | | | ****************PROVISO**************** | | | A}PER FBC-2004 FUEL GAS SECTION 409.5 EQUIPMENT | | | SHUTOFF VALVE: EACH APPLIANCE SHALL BE PROVIDED WITH A | | | SHUTOFF VALVE SEPERATE FROM THE APPLIANCE. THE SHUTOFF | | | VALVE SHALL BE LOCATED IN THE SAME ROOM AS THE | | | APPLIANCE, NOT FURTHER THAN 6 FEET FROM THE APPLIANCE, | | | AND SHALL BE INSTALLED UPSTREAM FROM THE UNION, | | | CONNECTOR OR QUICK DISCONNECT DEVICE IT SERVES. SUCH | | | SHUTOFF VALVES SHALL BE PROVIDED WITH ACCESS. | | | | | | B} PER FBC-2004 FUEL GAS, SECTION 404.13.3AN | | | INSULATED COPPER TRACER WIRE SHALL BE INSTALLED | | | ADJACENT TO UNDERGROUND NONMETALLIC GAS PIPING. THE | | | TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE | | | INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL. | | | | | | C} PER FBC-2004 FUEL GAS SECTION 408.4 A SEDIMENT TRAP | | | SHALL BE INSTALLED DOWNSTREAM OF THE EQUIPMENT SHUTOFF | | | VALVE AS CLOSE TO THE INLET OF THE EQUIPMENT AS | | | PRACTICAL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-01-10 |
Time |
11:18 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-01-10 |
Time |
11:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-15 |
Time |
08:18 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-11-15 |
Time |
08:18 |
Sent To |
PC |
|
| Notes |
| 2006-11-15 08:56:25 | UNSAT 2ND TIME | | | REFERENCE: FBC-2004 FUEL GAS AND FBC-2004 CHAPTER 1 | | | | | | THE PRIVIOUS GAS PLAN REVIEW COMMENTS FROM 10/18/06 | | | WERE NOT ADDRESSED. PLEASE KNOW THAT A GAS PERMIT | | | APPLICATION WITHOUT DRAWINGS OF THE GAS SYSTEM HAS BEEN | | | SUBMITTED WITH THE MASTER GEN/RES APPLICATION. THE | | | FOLLOWING INFORMATION IS REQUIRED FOR GAS PLAN REVIEW | | | IN ORDER TO RECIEVE A GEN/RES PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | 12. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-10-18 |
Time |
10:26 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-10-18 |
Time |
10:26 |
Sent To |
M |
|
| Notes |
| 2006-10-18 10:45:58 | ******UNSAT****** | | | REFERENCE: FBC-2004 FUEL GAS AND CHAPTER 1 | | | | | | PLEASE KNOW THAT A GAS PERMIT APPLICATION WITHOUT | | | DRAWINGS OF THE GAS SYSTEM HAS BEEN SUBMITTED WITH THE | | | MASTER GEN/RES PERMIT. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR GAS PLAN REVIEW: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (IF APPLICABLE) | | | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2 | | | | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | 12. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-06 |
Time |
13:58 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-09-06 |
Time |
13:58 |
Sent To |
B |
|
| Notes |
| 2006-09-06 00:00:00 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. | | | | | | ******IMPROTANT INFORMATION****** | | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | | MATION AND GAS (OR DIESEL) INFORMATION | | | IS ALL SUBMITTED AT THE SAME TIME. THE | | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | | FORMATION WILL BE ROUTED TOGETHER. THIS | | | WILL ENSURE THAT ALL OF THE INFORMATION | | | (PARTICULARLY THE MANUFACTURER'S SPECI- | | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-26 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-26 |
Time |
16:01 |
Sent To |
G |
|
| Notes |
| 2007-04-26 16:01:46 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-27 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-27 |
Time |
14:39 |
Sent To |
E |
|
| Notes |
| 2006-12-27 14:43:35 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-07 |
Time |
16:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-07 |
Time |
16:00 |
Sent To |
G |
|
| Notes |
| 2006-11-07 16:02:11 | TO "G" BOX/RESUB--"E" REVIEW NOT NEEDED. PLANS PASSED | | | BY "E" 10/16/06 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-05 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-05 |
Time |
13:35 |
Sent To |
E |
|
| Notes |
| 2006-10-05 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-22 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-22 |
Time |
14:29 |
Sent To |
E |
|
| Notes |
| 2006-08-22 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-08-12 |
Time |
14:07 |
Sent To |
PC |
|
| Notes |
| 2006-08-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-18 |
Time |
13:39 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-10-18 |
Time |
13:39 |
Sent To |
Z |
|
| Notes |
| 2006-10-18 13:40:26 | RE-STAMP. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-05 |
Time |
16:20 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-05 |
Time |
16:20 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-10-26 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-10-26 |
Time |
14:00 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-19 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-19 |
Time |
17:51 |
Sent To |
I |
|
| Notes |
|
|