Plan Review Details - Permit 06080517
Plan Review Stops For Permit 06080517
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-15 Cont ID  
Sent By shill Date 2006-12-15 Time 12:25 Rev Time 0.00
Received By shill Date 2006-12-15 Time 12:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-24 Cont ID  
Sent By shill Date 2006-10-24 Time 14:16 Rev Time 0.00
Received By shill Date 2006-10-24 Time 14:16 Sent To  
Notes
2006-10-24 14:26:08****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL.
  
 2.)WHEN APPLYING FOR LOCAL PRODUCT APPROVAL, ADVISE
 AS TO HOW QUALITY ASSURANCE REQUIRED BY FAC9B72 WILL BE
 ADDRESSED.
  
 3.)THE ENGINEERING REFLECTS FOUR SIDED SUPPORT, BUT
 TWO ARE SOFT SUPPORT AND SHOULD NOT BE ADDRESSED THE
 SAME AS THE STRUCTURAL SUPPORT.PLEASE ADDRESS, ITEM 4
 IN CLARIFICATION.
  
 4.)PHOTOCOPIES WERE SUBMITTED.ALL DOCUMENTS
 PREPARED BY AN ENGINEER AND SUBMITTED FOR PUBLIC RECORD
 ARE TO BE SIGNED,SEALED, DATED ORIGINALS
 FAC61G16-23.002.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-16 Cont ID  
Sent By shill Date 2006-08-16 Time 13:26 Rev Time 0.00
Received By shill Date 2006-08-16 Time 12:03 Sent To  
Notes
2006-08-16 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 BUILDING
 FBC RFLORIDA BUILDING CODE 2004
 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)COMPLETE A LOCAL PRODUCT APPROVAL
 APPLICATION, SEE ATTACHED.
  
 2.)THE ENGINEERING DOES NOT PROVIDE A
 DESIGN PRESSURE LIMITATION FOR THE BUTT
 GLASS WINDOW, ONLY THE REQUIREMENT FOR
 THE OPENING.
  
 3.)TWO SETS OF ENGINEERING SUBMTITTED.
 I BELIEVE THAT ONLY ONE IS REQUIRED; FOR
 THE 95 HIGH WINDOW.THE PROVISO THAT
 THERE WERE TWO BUTT GLASS OPENINGS TO BE
 PERMITTED WAS AN ERROR AS ONE HAS
 ALREADY BEEN ADDRESSED. THEREFORE, THIS
 REVIEW DOES NOT ADDRESS THE 84INCH HIGH
 OPENING.
  
 4.)SILICONE STRESS IS STATED, APPEARS
 TO BE A DESIGN REQUIREMENT.PROVIDE
 INFORMATION TO SHOW THAT THE GE1200 IS
 COMPLIANT, EITHER IN SPEC SHEETS OR
 STATEMENT ON THE PLAN.
  
 5.)CALCULATIONS REQUIRED.
  
 6.)HOW WILL QUALITY ASSURANCE BE
 ADDRESSED?AS THIS IS USUALLY ASSEMBLED
 IN THE FIELD, GENERALLY THE ENGINEER
 PROVIDES A LETTER STATING THAT HE WILL
 DO THE INSPECTION, AND AN INSPECTION
 LETTER PROVIDED AFTER THAT INSPECTION
 HAS BEEN DONE.
  
 7.)THE NOA IS NOT HELPFUL IN
 DETERMINING DESIGN PRESSURES FOR THE
 WINDOW.NO INFORMATION WAS IN THE
 PRODUCT APPROVAL RELATED TO THE GLASS,
 ONLY MULLIONS AND ANCHORS.USING THE
 CHART FOR MULLIONS, 96" (MULL) SPAN, AT
 -38PSF THE PRODUCT IS LIMITED TO 65IN,
 THIS IS A 69.5 IN TRIBUTARY WIDTH.THE
 GLASS SPECIFIED IN THE PRODUCT APPROVAL
 IS FOR 1/4" TEMPERED GLASS, THE
 ENGINEERING SPECIFIES 3/8" TEMPERED
 GLASS.
  
 8.)THE ENGINEERING STATES THAT THIS IS
 BASED ON 4 SIDED SUPPORT.IT APPEARS
 THAT TWO PANELS ARE SUPPORTED ON THREE
 SIDES, ONE IS SUPPORTED ON TWO SIDES.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-29 Cont ID  
Sent By mmiller Date 2006-11-29 Time 17:51 Rev Time 0.00
Received By mmiller Date 2006-11-29 Time 17:51 Sent To B
Notes
2006-12-10 18:36:40 
  
  
 12/10/06 SITE SPECIFIC PRODUCT APPROVAL, INCL. QUALITY
 ASSURANCE LETTER, ROUTED TO SAMANTHA HILL'S DESK.RB
2006-11-29 17:51:43SENT TO SAMANTHA HILL'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-13 Cont ID  
Sent By adarroug Date 2006-10-13 Time 16:55 Rev Time 0.00
Received By adarroug Date 2006-10-13 Time 16:55 Sent To B
Notes
2006-10-13 16:55:42TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-16 Cont ID  
Sent By mmiller Date 2006-08-16 Time 14:01 Rev Time 0.00
Received By shill Date 2006-08-11 Time 10:18 Sent To  
Notes
2006-08-11 00:00:00SENT TO MISC BOX #1