Plan Review Details - Permit 06080428
Plan Review Stops For Permit 06080428
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-07 Cont ID  
Sent By btrobaug Date 2006-12-07 Time 13:39 Rev Time 0.25
Received By btrobaug Date 2006-12-07 Time 13:39 Sent To  
Notes
2006-12-07 13:40:53 
  
 OK PER LUIS./WRT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-11-07 Cont ID  
Sent By lmartine Date 2006-11-07 Time 15:17 Rev Time 0.00
Received By lmartine Date 2006-11-07 Time 15:17 Sent To  
Notes
2006-11-07 15:37:01RECORDED NOTICE OF COMMENCEMENT IS REQUIRED.
2006-11-07 15:33:03 
  
  
 BUILDING COMMENTS
 ------------ ----------------
  
  
 PROVIDE TWO SETS OF DRAWINGS , SIGNED AND SEALED.
  
  
  
  
 L.MARTINEZ
 561-805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-21 Cont ID  
Sent By amorse Date 2006-08-21 Time 07:30 Rev Time 0.00
Received By amorse Date 2006-08-21 Time 07:30 Sent To PC
Notes
2006-08-21 00:00:00 
  
  
 DENIED
  
 1) PROVIDE WIND DESIGN DATA ON DRAWINGS
 PER 1603.1.4 FBC
  
 2) PROVIDE 2 COPIES OF SIGNED AND SEALED
 DRAWINGS THAT THE SIGNS WILL MEET THE
 WIND DESIGN AS PROVIDED IN NOTE #1
  
 3) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 4) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-07 Cont ID  
Sent By btrobaug Date 2006-12-07 Time 13:39 Rev Time 0.50
Received By btrobaug Date 2006-12-07 Time 13:25 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-11-03 Cont ID  
Sent By btrobaug Date 2006-11-03 Time 12:28 Rev Time 0.33
Received By btrobaug Date 2006-11-03 Time 12:10 Sent To B
Notes
2006-11-03 12:27:57 
  
 NONCOMPLIANT
  
  
 THE PERSON TAKING RESPONSIBILITY FOR THE
 DESIGN MUST PRINT AND SIGN THEIR NAME TO
 SAME PER 106.3.4.2. ALL SETS SUBMITTED, TWO REQUIRED
 FOR REVIEW, ONLY ONE SET SEALED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-17 Cont ID  
Sent By btrobaug Date 2006-08-17 Time 07:21 Rev Time 0.33
Received By btrobaug Date 2006-08-17 Time 07:11 Sent To B
Notes
2006-08-17 00:00:00 
  
 NONCOMPLIANT
  
  
 THE PERSON TAKING RESPONSIBILITY FOR THE
 DESIGN MUST PRINT AND SIGN THEIR NAME TO
 SAME PER 106.3.4.2.
  
 THE VALUE ON THE APPLICATION MUST
 INCLUDE THE TOTAL COST OF LABOR AND
 MATERIAL . VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF
 NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES PER 108.3 FBC AS AMENDED.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-29 Cont ID  
Sent By spalmer Date 2006-11-29 Time 19:12 Rev Time 0.00
Received By spalmer Date 2006-11-29 Time 19:12 Sent To E
Notes
2006-11-29 19:12:47RESUB/TO BTROBAUGH'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 16:32 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 16:32 Sent To E
Notes
2006-11-02 16:33:10TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-20 Cont ID  
Sent By adarroug Date 2006-10-20 Time 15:22 Rev Time 0.00
Received By adarroug Date 2006-10-20 Time 15:22 Sent To Z
Notes
2006-10-20 15:22:26TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-15 Cont ID  
Sent By adarroug Date 2006-08-15 Time 09:59 Rev Time 0.00
Received By adarroug Date 2006-08-15 Time 09:59 Sent To E
Notes
2006-08-15 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-08-21 Time   Rev Time 0.00
Received By adarroug Date 2006-08-08 Time 16:47 Sent To  
Notes
2006-08-08 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2006-11-02 Cont ID  
Sent By jroach Date 2006-11-02 Time 09:18 Rev Time 0.00
Received By jroach Date 2006-10-28 Time 06:05 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-14 Cont ID  
Sent By mmclean Date 2006-08-14 Time 15:56 Rev Time 0.00
Received By mmclean Date 2006-08-14 Time 15:56 Sent To I
Notes
2006-08-14 00:00:00DENIED,
 1. PLEASE PROVIDE THE APPROVED SQUARE
 FOOTAGE OF THE EXISTING SIGN (SIGN 1 &
 2) FOR STRUCTURE.
 2. PLEASE PROVIDE THE HEIGHT & WIDTH OF
 THE STRUCUTRE TO WHERE THE SIGN WILL BE
 LOCATED.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720