Plan Review Details - Permit 06080370
Plan Review Stops For Permit 06080370
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-03-29 Cont ID  
Sent By amorse Date 2007-03-29 Time 15:56 Rev Time 0.00
Received By amorse Date 2007-03-29 Time 15:56 Sent To P
Notes
2007-03-29 16:00:20 
 PASSEDREVISION
  
 ALTHOUGH THE DRAWINGS HAVE PASSED BUILDING REVIEW FOR
 THE REVISION DATED FEB 7, 2007 THEY ARE NOT STAMPED FOR
 APPROVAL AS ANOTHER SET OF UPDATED DRAWINGS WERE
 SUBMITTED ON FEB 21,2007 WITH CHANGES TO THE A/C
 LOCATION. I APPROVED AND STAMPED THIS SET BUT THERE ARE
 OUTSTANDING COMMENTS IN ELECTRICAL BECAUSE THE SECOND
 SUBMITTAL CAME IN BEFORE ELECTRICAL REVIEW HAD DONE
 THEIR FIRST REVIEW. PLEASE REFRAIN FROM SUBMITTALS OR
 CHANGES BEFORE COMPLETE REVIEW BY ALL TRADES AS THIS
 WILL REQUIRE UNNECESSARY RESUB FEES AND LONGER WAIT
 TIMES.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-11-09 Cont ID  
Sent By jleech Date 2007-01-03 Time 12:32 Rev Time 0.00
Received By lmartine Date 2007-01-04 Time 12:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-09-08 Cont ID  
Sent By alange Date 2006-09-08 Time 10:42 Rev Time 1.00
Received By alange Date 2006-09-08 Time 10:00 Sent To  
Notes
2006-09-08 00:00:00DENIED
  
 1.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-06-12 Cont ID  
Sent By btrobaug Date 2007-06-12 Time 16:21 Rev Time 0.50
Received By btrobaug Date 2007-06-05 Time 08:57 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-04-19 Cont ID  
Sent By btrobaug Date 2007-04-19 Time 10:45 Rev Time 0.50
Received By btrobaug Date 2007-04-19 Time 10:21 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-02-27 Cont ID  
Sent By btrobaug Date 2007-02-27 Time 14:26 Rev Time 0.50
Received By btrobaug Date 2007-02-27 Time 14:25 Sent To P
Notes
2007-02-27 14:26:10 
 REVISION DENIED
  
 1} REGARDING THE FEED TO THE HOUSE FROM THE MAIN PANEL;
 250.32(B)(1) EQUIPMENT GROUNDING CONDUCTOR. AN
 EQUIPMENT GROUNDING CONDUCTOR AS DESCRIBED IN 250.118
 SHALL BE RUN WITH THE SUPPLY CONDUCTORS AND CONNECTED
 TO THE BUILDING OR STRUCTURE DISCONNECTING MEANS AND TO
 THE GROUNDING ELECTRODE(S). THE EQUIPMENT GROUNDING
 CONDUCTOR SHALL BE USED FOR GROUNDING OR BONDING OF
 EQUIPMENT, STRUCTURES, OR FRAMES REQUIRED TO BE
 GROUNDED OR BONDED. THE EQUIPMENT GROUNDING CONDUCTOR
 SHALL BE SIZED IN ACCORDANCE WITH 250.122. ANY
 INSTALLED GROUNDED CONDUCTOR SHALL NOT BE CONNECTED TO
 THE EQUIPMENT GROUNDING CONDUCTOR OR TO THE GROUNDING
 ELECTRODE(S).
  
 2} THE TANKLESS WATER HEATER IS NOT INCLUDED IN THE
 LOAD CALCULATIONS, PLEASE INCLUDE AND RECALCULATE.
  
 3} GIVEN IT CONTAINS OVERCURRENT PROTECTION, PER
 240.22(D), THE TANKLESS HEATER CANNOT BE LOCATED IN A
 CLOSET.
  
 4} 210.63 HEATING, AIR-CONDITIONING, AND REFRIGERATION
 EQUIPMENT OUTLET.
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT.THE
 RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND
 WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING,
 AND REFRIGERATION EQUIPMENT. LOCATE ON THE PLAN.
  
 5} 210.52(E)-) OUTDOOR OUTLETS. FOR A ONE-FAMILY
 DWELLING AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS
 AT GRADE LEVEL, AT LEAST ONE RECEPTACLE OUTLET
 ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 2.0 M (61/2
 FT) ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND
 BACK OF THE DWELLING. SEE 210.8(A)(3). LOCATE ON THE
 PLAN.
  
 6} THE DISCONNECTING MEANS FOR THE CONDENSER IS IN
 VIOLATION OF 110.26 CLEARANCE REQUIREMENTS.
  
 7} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1
 RESIDENTIAL FLORIDA BUILDING CODE. PLEASE LOCATE ON THE
 PLAN.
  
 8} SUBMIT A PANEL SCHEDULE PER 408.4 NEC AND
 106.3.5.4(8) FBC.FOR THE NEW 200 AMP PANEL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-02-26 Cont ID  
Sent By btrobaug Date 2007-02-26 Time 15:11 Rev Time 1.00
Received By btrobaug Date 2007-02-26 Time 07:53 Sent To P
Notes
2007-02-26 15:11:25 
  
 REVISION DENIED
  
 1} REGARDING THE FEED TO THE HOUSE FROM THE MAIN PANEL;
 250.32(B)(1) EQUIPMENT GROUNDING CONDUCTOR. AN
 EQUIPMENT GROUNDING CONDUCTOR AS DESCRIBED IN 250.118
 SHALL BE RUN WITH THE SUPPLY CONDUCTORS AND CONNECTED
 TO THE BUILDING OR STRUCTURE DISCONNECTING MEANS AND TO
 THE GROUNDING ELECTRODE(S). THE EQUIPMENT GROUNDING
 CONDUCTOR SHALL BE USED FOR GROUNDING OR BONDING OF
 EQUIPMENT, STRUCTURES, OR FRAMES REQUIRED TO BE
 GROUNDED OR BONDED. THE EQUIPMENT GROUNDING CONDUCTOR
 SHALL BE SIZED IN ACCORDANCE WITH 250.122. ANY
 INSTALLED GROUNDED CONDUCTOR SHALL NOT BE CONNECTED TO
 THE EQUIPMENT GROUNDING CONDUCTOR OR TO THE GROUNDING
 ELECTRODE(S).
  
 2} THE TANKLESS WATER HEATER IS NOT INCLUDED IN THE
 LOAD CALCULATIONS, PLEASE INCLUDE AND RECALCULATE.
  
 3} GIVEN IT CONTAINS OVERCURRENT PROTECTION, PER
 240.22(D), THE TANKLESS HEATER CANNOT BE LOCATED IN A
 CLOSET.
  
 4} 210.63 HEATING, AIR-CONDITIONING, AND REFRIGERATION
 EQUIPMENT OUTLET.
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING,
 AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT.THE
 RECEPTACLE SHALL BE LOCATED ON THE SAME LEVEL AND
 WITHIN 7.5 M (25 FT) OF THE HEATING, AIR-CONDITIONING,
 AND REFRIGERATION EQUIPMENT. LOCATE ON THE PLAN.
  
 5} 210.52(E)-) OUTDOOR OUTLETS. FOR A ONE-FAMILY
 DWELLING AND EACH UNIT OF A TWO-FAMILY DWELLING THAT IS
 AT GRADE LEVEL, AT LEAST ONE RECEPTACLE OUTLET
 ACCESSIBLE AT GRADE LEVEL AND NOT MORE THAN 2.0 M (61/2
 FT) ABOVE GRADE SHALL BE INSTALLED AT THE FRONT AND
 BACK OF THE DWELLING. SEE 210.8(A)(3). LOCATE ON THE
 PLAN.
  
 6} THE DISCONNECTING MEANS FOR THE CONDENSER IS IN
 VIOLATION OF 110.26 CLEARANCE REQUIREMENTS.
  
 7} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.1
 RESIDENTIAL FLORIDA BUILDING CODE. PLEASE LOCATE ON THE
 PLAN.
  
 8} SUBMIT A PANEL SCHEDULE PER 408.4 NEC AND
 106.3.5.4(8) FBC.FOR THE NEW 200 AMP PANEL.
  
 9} THE DESIGNER OF RECORD MUST SIGN DATE AND SEAL THE
 PLANS 471-481 FS OR MUST PRINT AND SIGN PER 106.3.4.2.
 FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status N Date 2006-12-21 Cont ID  
Sent By btrobaug Date 2006-12-21 Time 17:43 Rev Time 0.50
Received By btrobaug Date 2006-12-21 Time 17:43 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-11-02 Cont ID  
Sent By btrobaug Date 2006-11-02 Time 09:16 Rev Time 0.75
Received By btrobaug Date 2006-11-02 Time 06:28 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-15 Cont ID  
Sent By btrobaug Date 2006-08-15 Time 13:41 Rev Time 0.75
Received By btrobaug Date 2006-08-15 Time 12:39 Sent To P
Notes
2006-08-15 00:00:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} BATH CIRCUIT REQUIRED TO HAVE A 20
 AMP RECEPTACLE PER 210.11(C) (3),
 LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1).
  
 2} 210.8(A)(7)GFI REQUIRED@WET BAR SINKS
 ? WHERE THE RECEPTACLES ARE INSTALLED TO
 SERVE THE COUNTERTOP SURFACES AND ARE
 LOCATED WITHIN 1.8 M (6 FT) OF THE
 OUTSIDE EDGE OF THE WET BAR SINK.RE:
 CABANA.
  
 3} SMOKE DETECTORS MUST BE INSTALLED TO
 COMPLY WITH R313.1 RESIDENTIAL FLORIDA
 BUILDING CODE.
  
 4} 210.52(E) OUTDOOR OUTLETS. FOR A
 ONE-FAMILY DWELLING AND EACH UNIT OF A
 TWO-FAMILY DWELLING THAT IS AT GRADE
 LEVEL, AT LEAST ONE RECEPTACLE OUTLET
 ACCESSIBLE AT GRADE LEVEL AND NOT MORE
 THAN 2.0 M (61/2 FT) ABOVE GRADE SHALL
 BE INSTALLED AT THE FRONT AND BACK OF
 THE DWELLING. SEE 210.8(A)(3). THE
 CABANA MUST ALSO COMPLY.
  
 5} A #6 EQUIPMENT GROUND IS REQUIRED TO
 BE RAN WITH THE SUB FEEDER PER 250.110.
  
 IF THERE AR ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-01-04 Cont ID  
Sent By lmartine Date 2007-01-04 Time 12:25 Rev Time 0.00
Received By lmartine Date 2007-01-04 Time 12:25 Sent To  
Notes
2007-01-04 12:26:43SEE APPROVAL ON APPLICATION DATED 8/4/06
2006-08-04 00:00:00OK PER G JUDGE NO FEE 8-4-06

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-06-22 Cont ID  
Sent By adarroug Date 2007-06-22 Time 11:05 Rev Time 0.00
Received By adarroug Date 2007-06-22 Time 11:05 Sent To P
Notes
2007-06-22 11:06:07TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 16:08 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 16:08 Sent To E
Notes
2007-05-29 16:08:24TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-05-23 Cont ID  
Sent By adarroug Date 2007-05-23 Time 09:08 Rev Time 0.00
Received By adarroug Date 2007-05-23 Time 09:08 Sent To M
Notes
2007-05-23 09:08:21TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-04-06 Cont ID  
Sent By spalmer Date 2007-04-06 Time 17:18 Rev Time 0.00
Received By spalmer Date 2007-04-06 Time 17:18 Sent To E
Notes
2007-04-06 17:18:22TO BILL TROBAUGH

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-02-23 Cont ID  
Sent By adarroug Date 2007-02-23 Time 15:17 Rev Time 0.00
Received By adarroug Date 2007-02-23 Time 15:17 Sent To E
Notes
2007-02-23 15:18:32TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-02-20 Cont ID  
Sent By adarroug Date 2007-02-20 Time 17:32 Rev Time 0.00
Received By adarroug Date 2007-02-20 Time 17:32 Sent To E
Notes
2007-02-20 17:32:44TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-02-08 Cont ID  
Sent By adarroug Date 2007-02-08 Time 16:01 Rev Time 0.00
Received By adarroug Date 2007-02-08 Time 16:01 Sent To Z
Notes
2007-02-08 16:02:25TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-01-03 Cont ID  
Sent By adarroug Date 2007-01-03 Time 12:19 Rev Time 0.00
Received By adarroug Date 2007-01-03 Time 12:19 Sent To P
Notes
2007-01-03 12:19:50TO "P" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-12-15 Cont ID  
Sent By adarroug Date 2006-12-15 Time 16:08 Rev Time 0.00
Received By adarroug Date 2006-12-15 Time 16:08 Sent To M
Notes
2006-12-15 16:08:53TO "TGORDON" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-12-06 Cont ID  
Sent By adarroug Date 2006-12-06 Time 13:50 Rev Time 0.00
Received By adarroug Date 2006-12-06 Time 13:50 Sent To Z
Notes
2006-12-06 13:50:34TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-01 Cont ID  
Sent By adarroug Date 2006-11-01 Time 18:51 Rev Time 0.00
Received By adarroug Date 2006-11-01 Time 18:51 Sent To E
Notes
2006-11-01 18:51:48TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-24 Cont ID  
Sent By mmclean Date 2006-10-31 Time 15:34 Rev Time 0.00
Received By adarroug Date 2006-10-24 Time 17:29 Sent To Z
Notes
2006-10-24 17:29:28TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-12 Cont ID  
Sent By adarroug Date 2006-08-12 Time 16:32 Rev Time 0.00
Received By adarroug Date 2006-08-12 Time 16:32 Sent To E
Notes
2006-08-12 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-09-08 Cont ID  
Sent By alange Date 2006-09-08 Time 10:43 Rev Time 0.00
Received By alange Date 2006-08-07 Time 17:05 Sent To  
Notes
2006-08-07 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-05-23 Cont ID  
Sent By tgordon Date 2007-05-23 Time 15:45 Rev Time 0.30
Received By tgordon Date 2007-05-23 Time 15:45 Sent To  
Notes
2007-05-23 15:47:27REVISION TO MECHANICAL PLANS.
 *** PROVISO ***
 1) DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS
 OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE
 SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET
 STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO
 OPENINGS INTO THE GARAGE. PER 2004 FBC/R 309.1.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-12-18 Cont ID  
Sent By tgordon Date 2006-12-18 Time 08:37 Rev Time 0.30
Received By tgordon Date 2006-12-18 Time 08:37 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-11-03 Cont ID  
Sent By tgordon Date 2006-11-03 Time 09:00 Rev Time 0.30
Received By tgordon Date 2006-11-03 Time 09:00 Sent To B
Notes
2006-11-03 09:08:14*** DENIED ***
 1) AS NOTED IN LAST REVIEW 8-24-06, NO MECHANICAL PLANS
 WERE SUBMITTED FOR REVIEW, PLEASE SUBMIT MECHANICAL
 PLANS FOR REVIEW, PER 2004 FBC WPB AMEND. 106.3.5.4.
  
 2) ENERGY CALCULATIONS FORM 600C-04 CAN NOT BE USED FOR
 THE CABANA AS IT IS NOT AN ADDITION OR RENOVATION, PER
 2004 FBC 13-600.3C. PLEASE SUBMIT FORM 'A' OR' B' FOR
 THE CABANA.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-08-24 Cont ID  
Sent By tgordon Date 2006-08-24 Time 16:27 Rev Time 0.25
Received By tgordon Date 2006-08-24 Time 16:27 Sent To B
Notes
2006-08-24 00:00:00*** DENIED ***
 1) NO MECHANICAL PLANS WERE SUBMITTED
 FOR REVIEW. PLEASE SUBMIT MECHANICAL
 PLANS FOR REVIEW, OR YOU MAY WISH TO
 VOID YOUR MECHANICAL PERMIT NUMBER
 06080374 SO YOUR BUILDING PLANS MAY
 BY-PASS A MECHANICAL REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 8 Status P Date 2007-07-24 Cont ID  
Sent By jleech Date 2007-07-24 Time 07:56 Rev Time 0.00
Received By jleech Date 2007-07-24 Time 07:56 Sent To  
Notes
2007-07-24 07:57:47CHANGED SHOWER IN MASTER BATHROOM TO TUB

Review Stop P PLUMBING
Rev No 7 Status P Date 2007-03-30 Cont ID  
Sent By jleech Date 2007-03-30 Time 08:00 Rev Time 0.00
Received By jleech Date 2007-03-30 Time 08:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 6 Status P Date 2007-02-27 Cont ID  
Sent By jleech Date 2007-02-27 Time 09:15 Rev Time 0.00
Received By jleech Date 2007-02-27 Time 09:15 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-01-03 Cont ID  
Sent By jleech Date 2007-01-03 Time 12:54 Rev Time 0.00
Received By jleech Date 2007-01-03 Time 12:54 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-01-04 Cont ID  
Sent By jleech Date 2007-01-04 Time 12:49 Rev Time 0.00
Received By jleech Date 2007-01-04 Time 12:49 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-12-18 Cont ID  
Sent By jleech Date 2006-12-18 Time 15:18 Rev Time 0.00
Received By jleech Date 2006-12-18 Time 15:18 Sent To E
Notes
2006-12-18 15:29:24DENIED;
 MASTER BATH IN FRONT HOUSE OK.
 CABANA;
 1. RISER DIAGRAM DOES NOT MEET CODE.
 (A)SHOWER IS NOT VENTED. ( AVENT IS REQUIRED
 UP STREAM OF THE TOILET).
 (B)THE SINK CA NOT BE PART OF THE WET VENT
 FOR THE BATHROOM GROUP SEE SECTION 909.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-11-03 Cont ID  
Sent By jleech Date 2006-11-03 Time 07:29 Rev Time 0.00
Received By jleech Date 2006-11-03 Time 07:29 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-08-24 Cont ID  
Sent By jleech Date 2006-08-24 Time 15:31 Rev Time 0.00
Received By jleech Date 2006-08-24 Time 15:31 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status F Date 2007-02-15 Cont ID  
Sent By jroach Date 2007-02-15 Time 08:47 Rev Time 0.00
Received By jroach Date 2007-02-15 Time 08:47 Sent To I
Notes
2007-02-15 08:51:00***REVISION FAILED***
  
 1) SURVEY SHALL BE PROVIDED INDICATING THE LOCATION OF
 THE PROPOSED STRUCTURES AND THE DISTANCES FROM THE
 STRUCTURES TO THE PROPERTY LINES.
  
 2) DISTANCES FROM THE CABANA A/C EQUIPMENT TO THE
 PROPERTY LINES SHALL BE PROVIDED.THE EQUIPMENT SHALL
 BE NO CLOSER THAN 8.5 FEET TO THE REAR PROPERTY LINE.
  
 3) BUILDING HEIGHT ON THE ELEVATIONS SHALL BE MEASURED
 FROM GRADE TO THE MEAN POINT OF THE PITCH OF THE ROOF.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 3 Status P Date 2006-12-15 Cont ID  
Sent By mmclean Date 2006-12-15 Time 07:02 Rev Time 0.00
Received By mmclean Date 2006-12-14 Time 11:03 Sent To I
Notes
2006-12-14 11:17:10PROVISO: THE PROPOSED A/C UNIT SHALL NOT BE CLOSER THAN
 6FT FROM SIDE PROPERTY LINE.
  
 NOTE: MUST PULL A SEPARATE PERMIT FOR POOL/SPA/DECK.
  
 PROVISO: THE PROPOSED A/C UNIT SHALL NOT BE CLOSER THAN
 6FT FROM SIDE PROPERTY LINE AND 8FT FROM REAR PROPERTY
 LINE (GUEST CABANA)

Review Stop Z ZONING
Rev No 2 Status F Date 2006-10-31 Cont ID  
Sent By mmclean Date 2006-10-31 Time 14:55 Rev Time 0.00
Received By mmclean Date 2006-10-31 Time 14:55 Sent To I
Notes
2006-10-31 15:24:09DENIED,
 1. THE SITEPLAN DOES NOT SHOW THE FRONT SETBACK OF THE
 STRUCTURE FROM PROPERTY LINE.
 2. THE SURVEY DOES NOT SHOW ALL THAT IS NEEDED TO
 REVIEW THE APPLICATION (SITEPLAN WILL BE USED FOR
 REVIEW).
 3. PLEASE PROVIDE THE DIMENSION OF THE EXISTING WALKWAY
 AND THE RELOCATED WALKWAY (WIDTH & LENGTH).
 4. HISTORIC MUST REVIEW THE NEW REVISED PLANS.
  
 NOTE: MUST PULL A SEPARATE PERMIT FOR THE PROPOSED
 POOL/SPA/DECK

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-12 Cont ID  
Sent By mmclean Date 2006-08-12 Time 10:24 Rev Time 0.00
Received By mmclean Date 2006-08-12 Time 10:24 Sent To I
Notes
2006-08-12 00:00:00DENIED,
 1. THE PROPOSED SITEPLANS DOES NOT
 PROVIDE THE ADDRESS OF THE PROPERTY.
 2. THE PROPOSED/EXISTING STRUCTURE MUST
 SHOW THE SETBACKS FROM THE PROPERTY LINE
 (FRONT & SIDES).
 3. THE NEW PROPOSED WORK MUST MEET THE
 CURRENT SIDE SETBACKS. PLANS SHOW 3-4'
 12/16".
 SF14 - FRONT: 25FT, SIDE: FIVE FEET
 MINIMUM, 15FT TOTAL. ONE SIDE MUST BE A
 MINIMUM OF 5FT.
 4. PLEASE SUBMIT A COPY OF CURRENT
 SURVEY.
 5. PLEASE SHOW THE EXISTING
 DRIVEWAY/WALKWAY AND ANY NEW, WITH
 DIMENSION (WIDTH & LENGTH)
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720