| 2007-01-16 07:48:39 | BUILDING PLAN REVIEW |
| | PERMIT:06080340 |
| | ADD:? |
| | CONT: ECD |
| | TEL: (561)822-1252 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 2ND |
| | ACTION: DENIED |
| | |
| | 1)THE ADDRESS ON THE APPLICATION AND DRAWINGS DOES |
| | NOT MATCH THE ONE IN OUR SYSTEM. CLARIFY. |
| | |
| | 2)106.1 IF THE DESIGN PPOFISSIONAL IS AN ARCHITECT OR |
| | ENGINEER LEGALLY REGISTERED UNDER THE LAWS OF THIS |
| | STATE TEGULATING THE PRACTICE OF ARCHITECTURE AS |
| | PROVIDED FOR IN CHAPTER 481 OR 471 OF THE FLORIDA |
| | STATUTES,THEN HE ODR SHE SHALL AFFIX HIS OR HER |
| | OFFICIAL SEAL, SIGNATURE AND DATE TO SAID DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA AS REQUIRED BY |
| | FLORIDA STATUTE. |
| | |
| | 3)ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| | |
| | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH |
| | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. |
| | |
| | _XX__ 2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING |
| | INFORMATION ON THE APPLICATION, SEE ATTACHED |
| | POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / |
| | AREA OF EACH ROOF TYPE |
| | |
| | _XX__ 3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED IN ADDITION TO THE EVALUATION REPORT |
| | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG |
| | |
| | _XX__4.)FOR THE FLAT DECK, SELECT THE APPROVED |
| | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER |
| | IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. |
| | |
| | _XX__ 5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED |
| | FASTENING FOR CORNER AND PERIMETER ZONES. |
| | |
| | _XX__ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH |
| | METHOD OF ATTACHMENT YOU ARE USING. |
| | |
| | _XX__ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS |
| | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF |
| | CONSULTANT REQUIRED FOR ENHANCED FASTENING. |
| | |
| | |
| | NOTE: FBC 1609.6.6.2THE SYSTEM SELECTED |
| | FROM THE SUBMITTED FLAT ROOF PRODUCT |
| | APPROVAL NOA HAS A MAXIMUM DESIGN |
| | PRESSURE OF LESS THAN -89 PSF AND CITES |
| | GENERAL LIMITATION #9.GENERAL LIMITATION #9 |
| | PROHIBITS |
| | RATIONAL ANALYSIS OR EXTRAPOLATION TO |
| | ENHANCE THE UPLIFT PRESSURE AT PERIMETER |
| | AND CORNER AREAS BY REDUCING THE |
| | FASTENER SPACING IN THESE AREAS.EITHER |
| | SELECT AN ALTERNATIVE SYSTEM (OR PRODUCT |
| | APPROVAL) THAT DOES NOT CITE GENERAL |
| | LIMITATION #9.ALTERNATIVELY IF THE |
| | SELECTED SYSTEM DOES CITE GENERAL |
| | LIMITATION #9, IT MUST HAVE A MAXIMUM |
| | DESIGN PRESSURE THAT EXCEEDS THE |
| | PRESSURE IN ROOF ZONE 3 (TYPICALLY -89 |
| | PSF FOR MEAN ROOF HEIGHT OF 30 FEET OR |
| | LESS). |
| | |
| | 4)THE PRODUCT APPROVALS ARE MISSING THE FLORIDA STATE |
| | APPROVAL COVER SHEETS. |
| | |
| | 5)SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS |
| | APPLY |
| | |
| | _XX___1.PROVIDE BUILDING HEIGHT ON THE PLAN. DESIGN |
| | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE |
| | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY |
| | AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND |
| | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED |
| | ORIGINALS FAC61G15-23.002. |
| | |
| | _XX___2.COMPLETE THE ATTACHED INSTALLATION SCHEDULE |
| | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN |
| | ANOTHER FORMAT. |
| | |
| | _XX___3.FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. |
| | |
| | _XX___4.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS |
| | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A |
| | HIGHLIGHTER. |
| | |
| | _XX___5.SHOW THE EMERGENCY MEANS OF ESCAPE, |
| | |
| | _XX___ 6.PROVIDE A FLOOR PLAN SHOWING WHERE THE |
| | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH |
| | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4 |
| | ABOVE. |
| | |
| | 6)INDICATE THE OCCUPANT LOAD OFF THE BUILDING ON THE |
| | DRAWINGS. SEE FBC 1004. |
| | |
| | 7)FBC 302.3WHERE A BUILDING IS OCCUPIED BY TWO OR |
| | MORE USES NOT INCLUCED IN THE SAME OCCUPANCY |
| | CLASSIFICATION, THE BUILDING OR PORTION THEREOF SHALL |
| | COMPLY WITH SECTION 302.1 OR 302.3.2 OR A COMBINATION |
| | OF THESE SECTIONS. THEREFORE IF THERE IS MORE THAN ONE |
| | TYPE OF OCCUPANCY, THE OCCUPANCY HAS TO REFLECT THE |
| | CORRECT USE ACCORDING FBC SEC.302. |
| | |
| | 8)THE DESCRIPTION ON THE APPLICATION HAS TO BE MORE |
| | SPECIFIC TO SHOW THE WORK THAT WILL BE DONE ON THE |
| | PROJECT. |
| | |
| | 9)SIGNS AND FENCE REQUIRE SEPERATE PERMITS. |
| | |
| | 10)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH |
| | R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE |
| | INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY |
| | THE DESIGNER OF RECORD. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |
| | |
| | |
| | |