Plan Review Details - Permit 06080053
Plan Review Stops For Permit 06080053
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-10-30 Cont ID  
Sent By rmcdouga Date 2006-10-30 Time 13:02 Rev Time 0.00
Received By rmcdouga Date 2006-10-30 Time 12:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-12 Cont ID  
Sent By rmcdouga Date 2006-10-12 Time 15:25 Rev Time 0.00
Received By rmcdouga Date 2006-10-12 Time 15:25 Sent To  
Notes
2006-10-12 15:29:44DENIED
 1)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) ENERGY CALCULATION FORM MUST BE SIGNED BY THE
 OWNER.
  
 WHEN THESE ITEMS HAVE BEEN ADDRESSED THE STATUS WILL BE
 CHANGED TO PASS AND THE PERMIT CAN BE ISSUED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-29 Cont ID  
Sent By rmcdouga Date 2006-09-29 Time 07:23 Rev Time 0.00
Received By rmcdouga Date 2006-09-29 Time 07:33 Sent To M
Notes
2006-09-29 00:00:00DENIED BY BUILDING
  
 1)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) SUBMIT ENERGY CALULATION FORMS AS
 REQUIRED BY FBC 13-101.2.
  
 3) WPB ADMINISTRATIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. A STAMP IS
 NOT ACCEPTABLE, THEY MUST BE SIGNED BY
 DOR.
  
 4) THE PRODUCT APPROVAL STATE COVER
 SHEET FOR THE STORM PANELS IS FOR THE
 2001 CODE. THE ONE FOR THE 2004 FBC IS
 FL 7226 AND THE UPDATED ACOMPANYING NOA
 IS NOA NO 05-926.02. SUBMIT THE CURRENT
 PRODUCT INFORMATION.
  
 5) THE UPDATED NOA FOR THE 2100 SERIES
 SINGLE HUNG WINDOWS WITH FL 6585 IS NOA
 NO 05-0729.03. SUBMIT THE CURRENT
 PRODUCT INFORMATION.
  
 6) R303.3 BATHROOMS, WATER CLOSET
 COMPARTMENTS AND OTHER SIMILAR ROOMS
 SHALL BE PROVIDED WITH AGGREGATE GLAZING
 AREA IN WINDOWS OF NOT LESS THAN 3
 SQUARE FEET (0.279 M 2 ), ONE-HALF OF
 WHICH MUST BE OPENABLE.
 EXCEPTION: THE GLAZED AREAS SHALL NOT BE
 REQUIRED WHERE ARTIFICIAL LIGHT AND A
 MECHANICAL VENTILATION SYSTEM ARE
 PROVIDED. THE MINIMUM VENTILATION RATES
 SHALL BE 50 CFM (23.6 L/S) FOR
 INTERMITTENT VENTILATION OR 20 CFM (9.4
 L/S) FOR CONTINUOUS VENTILATION.
 VENTILATION AIR FROM THE SPACE SHALL BE
 EXHAUSTED DIRECTLY TO THE OUTSIDE.
 BECAUSE THE BATHROOM NO LONGER WILL HAVE
 A WINDOW OPENING TO THE EXTERIOR A
 MECHANICAL VENT WILL BE REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-23 Cont ID  
Sent By rmcdouga Date 2006-08-23 Time 10:15 Rev Time 0.00
Received By rmcdouga Date 2006-08-23 Time 06:55 Sent To  
Notes
2006-08-23 00:00:00DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE EXISTING BUILDING LEVEL OF
 ALTERATION IS LEVEL 2 NOT LEVEL 3. LEVEL
 3 ALTERATIONS APPLY WHERE THE WORK AREA
 EXCEEDS 50 PERCENT OF THE AGGREGATE AREA
 OF THE BUILDING AND MADE WITHIN ANY
 12-MONTH PERIOD.
  
 4) CLARIFY THAT A DOORWAY IS BEING
 CREATED BETWEEN THE EXISTING BEDROOM AND
  
 ENCLOSED CARPORT WHERE WINDOW IS BEING
 REMOVED.
  
 5) THE EMERGENCY EGRESS REQUIREMENT OF
 R310 MUST BE MAINTAINED IN THE EXISTING
 BEDROOM ADJACENT TO THE ENCLOSED GARAGE.
  
 6) GENERAL NOTE 3 ON SHEET 2 CALLS FOR
 8" MASONRY WALLS AND THE FLOOR PLAN
 SPECIFIES 2X4 FRAME WALLS 24" OC AND THE
 FOUNDATION PLAN ON SHEET 3 HAS FRAMING
 16"OC. PLEASE CORRECT.
  
 7) SPECIFY THE CONNECTORS THAT WILL BE
 USED TO ANCHOR THE NEW WALL TO TRUSSES
 AND NEW WALL TO EXISTING BEAM. 1/4" X 6"
 WOOD SCREWS DO NOT APPEAR TO BE ADEQUATE
 FOR UPLIFT.
  
 8) SPECIFY THE WASHER FOR THE ANCHOR
 BOLT AT THE BOTTOM PLATE. SEE R403.1.6.
  
 9) ANCHOR BOLTS ARE REQUIRED TO EXTEND A
 MINIMUM OF 7 INCHES INTO CONCRETE. SEE
 R403.1.6.
  
 10) R319.1 LOCATION REQUIRED.
 IN AREAS SUBJECT TO DECAY DAMAGE AS
 ESTABLISHED BY TABLE R301.2(1) , THE
 FOLLOWING LOCATIONS SHALL REQUIRE THE
 USE OF AN APPROVED SPECIES AND GRADE OF
 LUMBER, PRESSURE TREATED IN ACCORDANCE
 WITH AWPA C1, C2, C3, C4, C9, C15, C18,
 C22, C23, C24, C28, C31, C33, P1, P2 AND
 P3, OR DECAY-RESISTANT HEARTWOOD OF
 REDWOOD, BLACK LOCUST, OR CEDARS.
 5.WOOD SIDING, SHEATHING AND WALL
 FRAMING ON THE EXTERIOR OF A BUILDING
 HAVING A CLEARANCE OF LESS THAN 6 INCHES
 (152 MM) FROM THE GROUND.
 SPECIFY THE CLEARANCE FROM FINISH GRADE
 TO WALL SHEATHING AND FRAMING.
  
 11) SUBMIT ENERGY CALCULATION FORMS AS
 REQUIRED BY FBC 13-101.2.
  
 12) SPECIFY THE CEILING/ATTIC INSULATION
 ON THE PLANS.
  
 13) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SUBMIT
 PRODUCT APPROVALS FOR THE EXTERIOR
 WINDOW, DOOR AND STRUCTURAL CONNECTORS.
  
 14) W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 15) THE VALUE OF THE CONSTRUCTION HAS
 BEEN INCREASED TO $9343.OO BASED ON ICC
 CONSTRUCTION COST TABLE. INCLUDES LABOR
 AND MATERIAL COSTS CHARGED BY BUILDING
 CONTRACTORS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-08-11 Cont ID  
Sent By btrobaug Date 2006-08-11 Time 07:49 Rev Time 0.33
Received By btrobaug Date 2006-08-11 Time 07:45 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-30 Cont ID  
Sent By adarroug Date 2006-10-30 Time 11:19 Rev Time 0.00
Received By adarroug Date 2006-10-30 Time 11:19 Sent To B
Notes
2006-10-30 11:20:14TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-11 Cont ID  
Sent By adarroug Date 2006-10-11 Time 15:39 Rev Time 0.00
Received By adarroug Date 2006-10-11 Time 15:39 Sent To M
Notes
2006-10-11 15:40:41TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-27 Cont ID  
Sent By adarroug Date 2006-09-27 Time 13:20 Rev Time 0.00
Received By adarroug Date 2006-09-27 Time 13:20 Sent To B
Notes
2006-09-27 00:00:00TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-10 Cont ID  
Sent By adarroug Date 2006-08-10 Time 15:59 Rev Time 0.00
Received By adarroug Date 2006-08-10 Time 15:59 Sent To E
Notes
2006-08-10 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-23 Cont ID  
Sent By rmcdouga Date 2006-08-23 Time 10:15 Rev Time 0.00
Received By rmcdouga Date 2006-08-02 Time 10:44 Sent To  
Notes
2006-08-02 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2006-10-12 Cont ID  
Sent By tgordon Date 2006-10-12 Time 10:28 Rev Time 0.20
Received By tgordon Date 2006-10-12 Time 10:27 Sent To B
Notes
2006-10-12 10:29:45BATHROOM EXHAUST FAN IS EXISTING.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-10-03 Cont ID  
Sent By tgordon Date 2006-10-03 Time 11:50 Rev Time 0.25
Received By tgordon Date 2006-10-03 Time 11:50 Sent To  
Notes
2006-10-03 00:00:00*** DENIED ***
 1) BY INCLOSING THE BATHROOM WINDOW YOU
 WILL NEED TO INSTALL AN EXHAUST FAN, PER
 2004 FBC/R M1506.3 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2006-08-09 Cont ID  
Sent By mmclean Date 2006-08-09 Time 14:37 Rev Time 0.00
Received By mmclean Date 2006-08-09 Time 14:37 Sent To I
Notes
***NONE***