| Plan Review Stops For Permit 06080009 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-09-20 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-09-20 |
Time |
12:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-08-17 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-08-17 |
Time |
06:48 |
Sent To |
PC |
|
| Notes |
| 2006-08-17 00:00:00 | | | | 1) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3* | | | | | | 2) AN APPROVAL LETTER FROM YOUR HOA IS | | | REQUIRED. | | | | | | 3) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-20 |
Time |
07:23 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-09-20 |
Time |
07:15 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-11 |
Time |
08:32 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-08-11 |
Time |
08:10 |
Sent To |
P |
|
| Notes |
| 2006-08-11 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | THE #12 CONDUCTORS FEEDING THE HEAT PUMP | | | ON THE SCHEMATIC ARE TOO SMALL FOR THE | | | 50 AMP LOAD SERVED. 310.16. 2002 NEC | | | | | | PROVIDE A LOAD CALCULATION PER 220.31, | | | INCLUDE ADDED LOADS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
09:39 |
Sent To |
E |
|
| Notes |
| 2006-09-18 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-13 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-13 |
Time |
13:48 |
Sent To |
Z |
|
| Notes |
| 2006-09-13 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-10 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-10 |
Time |
15:13 |
Sent To |
E |
|
| Notes |
| 2006-08-10 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-17 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
10:55 |
Sent To |
Z |
|
| Notes |
| 2006-08-02 00:00:00 | SENT "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-15 |
Time |
09:54 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-08-15 |
Time |
09:54 |
Sent To |
B |
|
| Notes |
| 2006-08-15 00:00:00 | | | | | | | | | | ******PROVISO****** | | | FBC-2004 SEC. 424.2.12.1, OR FBCR-2004 | | | SEC. R4101.12.1 PRESSURE TESTS. PER | | | MANUFACTURE RECOMMENDATIONS, NO AIR TEST | | | SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | | | | FBC-2004 SEC. 424.2.14.4, OR FBCR-2004 | | | SEC. R4101.14.4 CONNECTIONS, ALL WATER | | | HEATING EQUIPMENT SHALL BE INSTALLED | | | WITH FLANGES OR UNION CONNECTIONS | | | ADJACENT TO THE HEATER. | | | (ADD TO NOTES) | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-15 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-15 |
Time |
18:14 |
Sent To |
I |
|
| Notes |
| 2006-09-15 00:00:00 | NTOE: THE PROPOSED POOL EQUIPMENT SHALL | | | NOT BE CLOSER THAN 6.1FT FROM SIDE | | | PROPERTY LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-08-09 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-09 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-09 |
Time |
17:35 |
Sent To |
I |
|
| Notes |
| 2006-08-09 00:00:00 | DENIED, | | | 1. NEED TO SHOW THE LOCATION OF THE | | | PROPOSED DECK ON THE TWO COPY OF SURVEY | | | WITH SETBACKS (SIDES & REAR). | | | 2. THE SETBACK FOR PROPOSED DECK IS AS | | | FOLLOWS: SIDE (INTERIOR) 3FT, (ZERO) 0FT | | | AND REAR 3FT. | | | 3. PLEASE PROVIDE THE HOA APPROVAL | | | 4. PLEASE SHOW THE LOCATION OF THE | | | PROPOSED ON THE TWO COPY OF SURVEY. | | | | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | 5. THE PROPOSED DECK CANNOT ENROACH INTO | | | THE 25FT DRAINAGE EASEMENT. IF SO, THE | | | OWNER OF THE DRAINAGE EASEMENT APPROVAL | | | LETTER MUST BE SUBMITTED AND SURVEY | | | STAMPED FOR APPROVAL. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|