Plan Review Details - Permit 06080009
Plan Review Stops For Permit 06080009
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-09-20 Cont ID  
Sent By mjacobs Date 2006-09-20 Time 14:31 Rev Time 0.00
Received By mjacobs Date 2006-09-20 Time 12:50 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-17 Cont ID  
Sent By mjacobs Date 2006-08-17 Time 07:35 Rev Time 0.00
Received By mjacobs Date 2006-08-17 Time 06:48 Sent To PC
Notes
2006-08-17 00:00:00 
 1) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3*
  
 2) AN APPROVAL LETTER FROM YOUR HOA IS
 REQUIRED.
  
 3) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-09-20 Cont ID  
Sent By btrobaug Date 2006-09-20 Time 07:23 Rev Time 0.33
Received By btrobaug Date 2006-09-20 Time 07:15 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-11 Cont ID  
Sent By adarroug Date 2006-08-11 Time 08:32 Rev Time 0.33
Received By btrobaug Date 2006-08-11 Time 08:10 Sent To P
Notes
2006-08-11 00:00:00 
  
 NONCOMPLIANT
  
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 THE #12 CONDUCTORS FEEDING THE HEAT PUMP
 ON THE SCHEMATIC ARE TOO SMALL FOR THE
 50 AMP LOAD SERVED. 310.16. 2002 NEC
  
 PROVIDE A LOAD CALCULATION PER 220.31,
 INCLUDE ADDED LOADS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-18 Cont ID  
Sent By adarroug Date 2006-09-18 Time 09:39 Rev Time 0.00
Received By adarroug Date 2006-09-18 Time 09:39 Sent To E
Notes
2006-09-18 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-13 Cont ID  
Sent By adarroug Date 2006-09-13 Time 13:48 Rev Time 0.00
Received By adarroug Date 2006-09-13 Time 13:48 Sent To Z
Notes
2006-09-13 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-10 Cont ID  
Sent By adarroug Date 2006-08-10 Time 15:49 Rev Time 0.00
Received By adarroug Date 2006-08-10 Time 15:13 Sent To E
Notes
2006-08-10 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-02 Cont ID  
Sent By adarroug Date 2006-08-17 Time 10:55 Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 10:55 Sent To Z
Notes
2006-08-02 00:00:00SENT "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-08-15 Cont ID  
Sent By mperson Date 2006-08-15 Time 09:54 Rev Time 0.33
Received By mperson Date 2006-08-15 Time 09:54 Sent To B
Notes
2006-08-15 00:00:00 
  
  
 ******PROVISO******
 FBC-2004 SEC. 424.2.12.1, OR FBCR-2004
 SEC. R4101.12.1 PRESSURE TESTS. PER
 MANUFACTURE RECOMMENDATIONS, NO AIR TEST
 SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
  
 FBC-2004 SEC. 424.2.14.4, OR FBCR-2004
 SEC. R4101.14.4 CONNECTIONS, ALL WATER
 HEATING EQUIPMENT SHALL BE INSTALLED
 WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER.
 (ADD TO NOTES)
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-09-15 Cont ID  
Sent By mmclean Date 2006-09-15 Time 18:14 Rev Time 0.00
Received By mmclean Date 2006-09-15 Time 18:14 Sent To I
Notes
2006-09-15 00:00:00NTOE: THE PROPOSED POOL EQUIPMENT SHALL
 NOT BE CLOSER THAN 6.1FT FROM SIDE
 PROPERTY LINE.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-09 Cont ID  
Sent By mmclean Date 2006-08-09 Time 17:35 Rev Time 0.00
Received By mmclean Date 2006-08-09 Time 17:35 Sent To I
Notes
2006-08-09 00:00:00DENIED,
 1. NEED TO SHOW THE LOCATION OF THE
 PROPOSED DECK ON THE TWO COPY OF SURVEY
 WITH SETBACKS (SIDES & REAR).
 2. THE SETBACK FOR PROPOSED DECK IS AS
 FOLLOWS: SIDE (INTERIOR) 3FT, (ZERO) 0FT
 AND REAR 3FT.
 3. PLEASE PROVIDE THE HOA APPROVAL
 4. PLEASE SHOW THE LOCATION OF THE
 PROPOSED ON THE TWO COPY OF SURVEY.
  
 SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
 5. THE PROPOSED DECK CANNOT ENROACH INTO
 THE 25FT DRAINAGE EASEMENT. IF SO, THE
 OWNER OF THE DRAINAGE EASEMENT APPROVAL
 LETTER MUST BE SUBMITTED AND SURVEY
 STAMPED FOR APPROVAL.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  