| 2006-08-21 00:00:00 | BUILDING DENIED |
| | |
| | 1)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) THE WINDOW IN THE NEW BATHROOM MUST |
| | COMPLY WITH FBC R308.4 (5). SAFETY |
| | GLAZING IS REQUIRED IN THE FOLLOWING |
| | LOCATION. |
| | 5.GLAZING IN DOORS AND ENCLOSURES |
| | FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM |
| | ROOMS, BATHTUBS AND SHOWERS. GLAZING IN |
| | ANY PART OF A BUILDING WALL ENCLOSING |
| | THESE COMPARTMENTS WHERE THE BOTTOM |
| | EXPOSED EDGE OF THE GLAZING IS LESS THAN |
| | 60 INCHES (1524 MM) MEASURED VERTICALLY |
| | ABOVE ANY STANDING OR WALKING SURFACE. |
| | |
| | 3) SPECIFY THE NEW WALLS ON THE PLANS. |
| | |
| | 4) PROVIDE A DETAIL OF NEW WALLS. |
| | SPECIFY FRAMING MATERIAL, STUD SPACING, |
| | WALL SHEATHING. |
| | |
| | 5) SPECIFY THE BATHROOM WALL AND FLOOR |
| | FINISHES. |
| | |
| | 6) FBC R303.3BATHROOMS. |
| | BATHROOMS, WATER CLOSET COMPARTMENTS AND |
| | OTHER SIMILAR ROOMS SHALL BE PROVIDED |
| | WITH AGGREGATE GLAZING AREA IN WINDOWS |
| | OF NOT LESS THAN 3 SQUARE FEET (0.279 M |
| | 2 ), ONE-HALF OF WHICH MUST BE OPENABLE. |
| | |
| | EXCEPTION: THE GLAZED AREAS SHALL NOT BE |
| | REQUIRED WHERE ARTIFICIAL LIGHT AND A |
| | MECHANICAL VENTILATION SYSTEM ARE |
| | PROVIDED. THE MINIMUM VENTILATION RATES |
| | SHALL BE 50 CFM (23.6 L/S) FOR |
| | INTERMITTENT VENTILATION OR 20 CFM (9.4 |
| | L/S) FOR CONTINUOUS VENTILATION. |
| | VENTILATION AIR FROM THE SPACE SHALL BE |
| | EXHAUSTED DIRECTLY TO THE OUTSIDE. |
| | MUST HAVE WINDOW THAT COMPLIES OR |
| | MECHANICAL VENTILATION. |
| | |
| | 7) TWO COMPLETE SETS OF PLANS ARE |
| | REQUIRED. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | |
| | |