Plan Review Details - Permit 06071838
Plan Review Stops For Permit 06071838
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-11-08 Cont ID  
Sent By jwitmer Date 2006-11-08 Time 13:03 Rev Time 0.77
Received By jwitmer Date 2006-11-08 Time 13:03 Sent To PC
Notes
2006-11-08 13:14:24REVISION 10-31-06 RACK REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-09-15 Cont ID  
Sent By jwitmer Date 2006-09-15 Time 11:08 Rev Time 0.77
Received By jwitmer Date 2006-09-15 Time 11:08 Sent To FIRE
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-15 Cont ID  
Sent By jwitmer Date 2006-08-15 Time 15:44 Rev Time 1.55
Received By jwitmer Date 2006-08-15 Time 15:44 Sent To PC
Notes
2006-08-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06071838
 ADD: 1318 MERCER AVE
 CONT: SOUTHERN CONSTRUCTION SYSTEMS
 TEL: (561)718-8876
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1) CITY AMENDMENT 104.2.1.
 ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 SHALL BEAR THE NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN.
  
 2) 104.2.1.3 THE BUILDING OFFICIAL MAY
 SET STANDARDS THROUGH DEPARTMENTAL
 POLICY STANDARDS FOR PLANS AND
 SPECIFICATIONS. PLANS HAVE BEEN COPIED
 TO A POINT THAT WILL NOT BE READABLE FOR
 RECORD RETENTION.
  
 3) PROVIDE A KEY PLAN SHOWING WHAT UNIT
 WILL REQUIRE ANCHORING TO THE FLOOR.
 WHAT TYPE OF ANCHOR TO BE USED. IF MORE
 THAN ONE ANCHOR WILL BE QUIRED AT EACH
 VERTICAL FRAME MEMBER.
  
 4) PROVIDE INFORMATION AS: 903.2.6.1
 HIGH-PILED STORAGE.
 AN AUTOMATIC SPRINKLER SYSTEM SHALL BE
 PROVIDED IN ACCORDANCE WITH THE FLORIDA
 FIRE PREVENTION CODE IN ALL BUILDINGS OF
 GROUP M WHERE STORAGE OF MERCHANDISE IS
 IN HIGH-PILED OR RACK STORAGE ARRAYS.
  
 5) IS THERE TO BE ELEVATED RACK STORAGE
 ACROSS THE AISLES.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-09-19 Cont ID  
Sent By mwennerg Date 2006-09-19 Time 14:41 Rev Time 0.00
Received By mwennerg Date 2006-09-19 Time 14:41 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-08-17 Cont ID  
Sent By mwennerg Date 2006-08-17 Time 15:40 Rev Time 0.00
Received By mwennerg Date 2006-08-17 Time 15:40 Sent To  
Notes
2006-08-17 00:00:00***DENIED***
  
 1) IS THIS AREA PROTECTED BY AN
 AUTOMATIC FIRE SPRINKLER SYSTEM?
  
 2) WHERE APPLICABLE, FIRE SPRINKLER
 REMODEL SHALL COMPLY WITH NFPA 13,
 REGARDING RACK AND HIGH PILE STORAGE.
  
 3) SEPARATE SHOP DRAWINGS AND PERMIT
 REQUIRED FOR FIRE SPRINKLER REMODEL.
  
 4) WILL ANY EXISTING FIRE ALARM
 EQUIPMENT BE IMPACTED IN TERMS OF
 VISIBILITY/AUDIBILTY WITH THE
 INTRODUCTION OF RACKS AND STORAGE?
  
 5) PLEASE SHOW THE LOCATIONS OF FIRE
 EXTINGUISHERS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 10:54 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 10:54 Sent To B
Notes
2006-11-02 10:55:05TO "JWITMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-13 Cont ID  
Sent By adarroug Date 2006-09-13 Time 16:28 Rev Time 0.00
Received By adarroug Date 2006-09-13 Time 16:28 Sent To  
Notes
2006-09-13 00:00:00TO "BOB"#11

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-17 Cont ID  
Sent By mwennerg Date 2006-08-17 Time 15:49 Rev Time 0.00
Received By mwennerg Date 2006-07-31 Time 18:06 Sent To  
Notes
2006-08-09 00:00:00TO "BOB"#12
2006-07-31 00:00:00WAITING FOR "BOB"