| Plan Review Stops For Permit 06071793 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-08-15 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-08-15 |
Time |
07:13 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-10-18 |
Time |
11:46 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-10-18 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-23 |
Time |
07:23 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-23 |
Time |
06:42 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-08 |
Time |
15:02 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-08 |
Time |
13:35 |
Sent To |
P |
|
| Notes |
| 2006-08-08 00:00:00 | | | | | | | PLEASE SUBMIT MANUFACTURERS | | | SPECIFICATIONS FOR THE "BADU JET", AND | | | LOCATE IN ELECTRICAL SCHEMATIC. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-14 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-14 |
Time |
14:14 |
Sent To |
P |
|
| Notes |
| 2006-10-14 14:14:40 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-25 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-25 |
Time |
15:42 |
Sent To |
P |
|
| Notes |
| 2006-09-25 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-15 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-15 |
Time |
16:10 |
Sent To |
P |
|
| Notes |
| 2006-09-15 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-08 |
Time |
10:57 |
Sent To |
P |
|
| Notes |
| 2006-09-08 00:00:00 | TO "P" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-22 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-22 |
Time |
18:31 |
Sent To |
E |
|
| Notes |
| 2006-08-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-08 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-08 |
Time |
11:25 |
Sent To |
E |
|
| Notes |
| 2006-08-08 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-08-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2006-07-31 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-07 |
Time |
13:10 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-11-07 |
Time |
13:10 |
Sent To |
PC |
|
| Notes |
| 2006-11-07 13:27:04 | REVISION: CHANGED PIPING SIZE OF BADU-JET MAIN DRAINS | | | FROM FOUR INCH (4") TO TWO INCH (2") |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-10-17 |
Time |
15:44 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-10-17 |
Time |
15:44 |
Sent To |
E |
|
| Notes |
| 2006-10-17 15:49:37 | REVISION: ADDING 4 HP BADU-JET PUMP SYSTEM, CODE | | | COMPLIANT TO MEET THREE (3) SECOND RELEASE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-29 |
Time |
14:18 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-29 |
Time |
14:18 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-21 |
Time |
13:14 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-21 |
Time |
13:14 |
Sent To |
PC |
|
| Notes |
| 2006-09-21 00:00:00 | ******DENIED 4TH TIME****** | | | REFERENCE: FBC-2004 SEC. 402.2 OR | | | FBRC-2004 SEC. 4101 SWIMMING POOLS AND | | | FBC-2004 CHAPTER 1: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW: | | | | | | 1. I KNOW THAT IT IS THE INTENT TO | | | DELETE THE BADU JET PUMP AND ALL | | | COMPONENTS RELATED, BUT PER FBC-2004 | | | CHAPTER 1 SEC. 106.1, FLORIDA STATUTES | | | CHAPTER 471, STATES THAT ANY HAND | | | WRITTEN CHANGES TO SIGNED AND SEALED | | | ENGINEERED DRAWINGS SHALL BE BY THE | | | ENGINEER OF RECORD, STEPHEN M. SINCLAIR, | | | P.E. FLORIDA LICENSE NO. 35631, | | | INITIALED AND DATED. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-14 |
Time |
11:53 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-14 |
Time |
11:53 |
Sent To |
PC |
|
| Notes |
| 2006-09-14 00:00:00 | ******DENIED 3RD TIME****** | | | REFERENCE: FBC-2004 SEC. 402.2 OR | | | FBRC-2004 SEC. R4101 SWIMMING POOLS: | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW: | | | NOTE: THE SUBMITTED MANUFACTURER SHEETS | | | WITH THE MET LABORATORIES, INC. | | | CERTIFICATION RECORD, FILE NUMBER, | | | E212148 APPROVES THE SUCTION FITTING PER | | | ASME/ANSI A112.19.8M. ALL SUCTION AND | | | RETURN PIPING TO THE BADU-JET PUMP SHALL | | | BE INSTALLED CODE COMPLIANT TO THE | | | FOLLOWING COMMENTS. | | | | | | 1) FBC-2004 SEC 424.2.6.6, OR FBCR-2004 | | | SEC R4101.6.6 ENTRAPMENT PROTECTION FOR | | | SUCTION INLETS. (DETAIL REQUIRED) | | | | | | 2) FBC-2004424.2.6.6.3, OR FBCR-2004 | | | SEC R4101.6.6.3 (1,2,3) ENTRAPMENT | | | AVOIDANCE. (DETAIL REQUIRED) | | | | | | 3) FBC-2004 SEC.424.2.6.6.4, OR | | | FBCR-2004 SEC. R4101.6.6.4 MINIMUM OF | | | TWO SUCTION INLETS SHALL BE PROVIDED FOR | | | EA PUMP. SEPARATED BY A MINIMUM OF 3 | | | FEET OR LOCATED ON TWO DIFFERENT PLANES. | | | (DETAIL REQUIRED) | | | | | | 4) FBC-2004 SEC. 424.6.6 OR FBC-2004 | | | RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT | | | PROTECTION FOR SUCTION INLETS. PLEASE | | | SUBMIT AN ENGINEERED TABLE FOR "VENT | | | PIPE MAXIMUM LENGTH" INDICATING PUMP | | | SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH | | | OF THE 1", 1-1/2" PVC VENT PIPE, FROM | | | WHERE IT STARTS TO WHERE IT ENDS UP, | | | COMPLYING WITH THE THREE SECOND RELEASE. | | | (NOTE: THE VENT TABLE ON THE PRINT ONLY | | | GOES TO TWO HORSE POWES (2 HP) THE BADU- | | | JET PUMP PUMP IS FOUR HORSE POWER (4 HP) | | | PLEASE SUBMIT A TABLE FOR THE HORSE | | | POWER (4 HP) BADU-JET PUMP. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-24 |
Time |
11:39 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-08-24 |
Time |
11:38 |
Sent To |
PC |
|
| Notes |
| 2006-08-24 00:00:00 | ******DENIED 2ND TIME****** | | | REFERENCE: FBC-2004 SEC. 402.2 OR | | | FBRC-2004 SEC. 4101 SWIMMING POOLS | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FOR PLUMBING PLAN REVIEW: | | | NOTE: THE SUBMITTED SHEETS DO NOT | | | ADDRESS PREVIOUS PLAN REVIEW COMMENTS. | | | | | | 1) PLEASE SUBMIT MANUFACTURER'S SPECIFI- | | | CATIONS FOR THE "BADU-JET" AND PROVIDE | | | THE FOLLOWING INFORMATION INDICATING THE | | | SYSTEM IS CODE COMPLIANT. | | | 2) FBC-2004 SEC 424.2.6.6, OR FBCR-2004 | | | SEC R4101.6.6 ENTRAPMENT PROTECTION FOR | | | SUCTION INLETS. (DETAIL REQUIRED) | | | 3) FBC-2004 424.2.6.6.2, OR FBCR-2004 | | | SEC R4101.6.6.2 SHOW COMPLIANCE WITH | | | ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUFACTURER INFORMATION FOR | | | VAC LOCK. (GIVE DETAIL, SUBMITTAL OR ADD | | | TO NOTES) | | | 4) FBC-2004424.2.6.6.3, OR FBCR-2004 | | | SEC R4101.6.6.3 (1,2,3) ENTRAPMENT | | | AVOIDANCE. (DETAIL REQUIRED) | | | 5) FBC-2004 SEC.424.2.6.6.4, OR | | | FBCR-2004 SEC. R4101.6.6.4 MINIMUM OF | | | TWO SUCTION INLETS SHALL BE PROVIDED FOR | | | EA PUMP. SEPARATED BY A MINIMUM OF 3 | | | FEET OR LOCATED ON TWO DIFFERENT PLANES. | | | (DETAIL REQUIRED) | | | 6) FBC-2004 SEC. 424.6.6 OR FBC-2004 | | | RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT | | | PROTECTION FOR SUCTION INLETS. PLEASE | | | SUBMIT AN ENGINEERED TABLE FOR "VENT | | | PIPE MAXIMUM LENGTH" INDICATING PUMP | | | SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH | | | OF THE 1", 1-1/2" PVC VENT PIPE, FROM | | | WHERE IT STARTS TO WHERE IT ENDS UP, | | | COMPLYING WITH THE THREE SECOND RELEASE. | | | (NOTE: THE VENT TABLE ON THE PRINT ONLY | | | GOES TO TWO HORSE POWER (2 HP) THE | | | "BADU-JET" PUMP IS FOUR HORSE POWER (4- | | | HP) PLEASE SUBMIT TABLE FOR SAID PUMP. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-10 |
Time |
13:22 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-08-10 |
Time |
13:22 |
Sent To |
B |
|
| Notes |
| 2006-08-10 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 SEC. 402.2 OR | | | FBRC-2004 SEC. 4101 SWIMMING POOLS: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW: | | | | | | 1) PLEASE SUBMIT MANUFACTURER'S SPECIFI- | | | CATIONS FOR THE "BADU-JET" AND PROVIDE | | | THE FOLLOWING INFORMATION INDICATING THE | | | SYSTEM IS CODE COMPLIANT. | | | 2) FBC-2004 SEC 424.2.6.6, OR FBCR-2004 | | | SEC R4101.6.6 ENTRAPMENT PROTECTION FOR | | | SUCTION INLETS. (DETAIL REQUIRED) | | | 3) FBC-2004 424.2.6.6.2, OR FBCR-2004 | | | SEC R4101.6.6.2 SHOW COMPLIANCE WITH | | | ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | | 4) FBC-2004424.2.6.6.3, OR FBCR-2004 | | | SEC R4101.6.6.3 (1,2,3) ENTRAPMENT | | | AVOIDANCE. (DETAIL REQUIRED) | | | 5) FBC-2004 SEC.424.2.6.6.4, OR | | | FBCR-2004 SEC. R4101.6.6.4 MINIMUM OF | | | TWO SUCTION INLETS SHALL BE PROVIDED FOR | | | EACH PUMP. SEPARATED BY A MINIMUM OF 3 | | | FEET OR LOCATED ON TWO DIFFERENT PLANES. | | | (DETAIL REQUIRED) | | | 6) FBC-2004 SEC. 424.6.6 OR FBC-2004 | | | RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT | | | PROTECTION FOR SUCTION INLETS. PLEASE | | | SUBMIT AN ENGINEERED TABLE FOR "VENT | | | PIPE MAXIMUM LENGTH" INDICATING PUMP | | | SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH | | | OF THE 1" OR 1-1/2" PVC VENT PIPE, FROM | | | WHERE IT STARTS TO WHERE IT ENDS UP, | | | COMPLYING WITH THE THREE SECOND RELEASE. | | | (NOTE: THE VENT TABLE ON THE DRAWING | | | ONLY GOES TO 2 HP THE "BADU-JET" PUMP IS | | | 4 HP) | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-07 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-07 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2006-08-07 00:00:00 | THE PROPOSED POOL EQUIPMENT SHALL NOT BE | | | CLOSER THAN 6FT FROM REAR PROPERTY LINE. |
|
|