Plan Review Details - Permit 06071716
Plan Review Stops For Permit 06071716
Review Stop ENG ENGINEERING CSD
Rev No 3 Status N Date 2007-08-15 Cont ID  
Sent By rchokshi Date 2007-08-15 Time 16:02 Rev Time 0.00
Received By rchokshi Date 2007-08-15 Time 16:01 Sent To FIRE
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2006-10-16 Cont ID  
Sent By rchokshi Date 2006-10-16 Time 16:18 Rev Time 0.00
Received By rchokshi Date 2006-10-16 Time 16:04 Sent To  
Notes
2006-10-16 16:18:16APPROVED ON CONDITION THAT PLANS MUST BE SEALED,
 SIGNED, & DATED BY PE. AT THIS MOMENT, PLANS ARE
 SEALED & SIGNED BUT NOT DATED. SO, WHEN YOU BRING
 PLANS, MAKE SURE THAT THEY ARE SEALED,SIGNED, & DATED
 BY PE. RASIK CHOKSHI

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By rchokshi Date 2006-08-07 Time 11:46 Rev Time 0.00
Received By rchokshi Date 2006-08-07 Time 11:21 Sent To  
Notes
2006-08-07 00:00:00FAILED FOR FOLLOWING REASONS:
  
 1.NEED TO APPROVE FROM UTILITY (45TH
 STREET, ENG SERVICES)
 2. NEED POLLUTION PREVENTION PLANS &
 DETAILS
 3. ALL CITY DETAILS FOR
 SIDEWALK,DRIVEWAY,ADA, PARKINGS,MUST BE
 IN PLANS
 4. DRAINAGE STRUCTURE TABLE SHEET 11 NOT
 CONSISTENT WITH PLANS
 5. WHAT IS MODIFIED TYPE "E" TYPE "C",
 ON SH.14 ELEVATION NOT CLEAR.
 6 SH. 12 CROSS SECTION NOT FOUND IN
 OTHER SHEETS
 7 GRADING & DRAINGE PLAN SH 8 SAYS SEE
 SH 12 FOR WIDE TRENCH DRAIN, NOT FOUNF
 IN SH.12
 8. MANY PLACES THERE IS NO CROSS
 REFERENCES FOR DETAILS , SO IT IS HARD
 OR IMPOSSIBLE TO REVIEW DRAWINGS
  
 RASIK CHOKSHI 805-6723

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-08-29 Cont ID  
Sent By mawillia Date 2007-08-29 Time 12:55 Rev Time 0.00
Received By mawillia Date 2007-08-29 Time 11:03 Sent To  
Notes
2007-08-29 12:58:37*****APPROVED FIRE-LINE REVISION
  
 PLAN SHEET (21 OF 29) STAMPED, INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-11-16 Cont ID  
Sent By adarroug Date 2007-11-16 Time 17:02 Rev Time 0.00
Received By adarroug Date 2007-11-16 Time 17:02 Sent To Z
Notes
2007-11-16 17:02:37TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-10-15 Cont ID  
Sent By adarroug Date 2007-10-15 Time 08:28 Rev Time 0.00
Received By adarroug Date 2007-10-15 Time 08:28 Sent To ENG
Notes
2007-10-15 08:28:32TO "ENG" BOX

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-10-10 Cont ID  
Sent By adarroug Date 2007-10-10 Time 16:55 Rev Time 0.00
Received By adarroug Date 2007-10-10 Time 16:55 Sent To Z
Notes
2007-10-10 16:56:03TO "Z" BOX/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-08-13 Cont ID  
Sent By adarroug Date 2007-08-13 Time 13:07 Rev Time 0.00
Received By adarroug Date 2007-08-13 Time 13:07 Sent To ENG
Notes
2007-08-13 13:07:47TO "ENG" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-27 Cont ID  
Sent By adarroug Date 2006-11-27 Time 09:44 Rev Time 0.00
Received By adarroug Date 2006-11-27 Time 09:44 Sent To ENG
Notes
2006-11-27 09:45:17TO "ENG" BOX

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-09 Cont ID  
Sent By adarroug Date 2006-11-09 Time 15:06 Rev Time 0.00
Received By adarroug Date 2006-11-09 Time 15:06 Sent To Z
Notes
2006-11-09 15:06:39TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-12 Cont ID  
Sent By adarroug Date 2006-10-12 Time 10:18 Rev Time 0.00
Received By adarroug Date 2006-10-12 Time 10:18 Sent To ENG
Notes
2006-10-12 10:18:49TO "ENG" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 18:34 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 18:34 Sent To Z
Notes
2006-10-10 18:34:50TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-24 Cont ID  
Sent By adarroug Date 2006-08-22 Time 13:56 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 13:42 Sent To  
Notes
2006-07-31 00:00:00TO "ENG" BOX

Review Stop Z ZONING
Rev No 5 Status P Date 2007-11-19 Cont ID  
Sent By eschneid Date 2007-11-19 Time 14:21 Rev Time 0.00
Received By eschneid Date 2007-11-19 Time 14:21 Sent To PC
Notes
2007-11-19 14:24:17REVISION FOR THE RAILROAD TIES ALONG THE WEST PROPERTY
 LINE ONLY.

Review Stop Z ZONING
Rev No 4 Status P Date 2007-10-12 Cont ID  
Sent By eschneid Date 2007-10-12 Time 14:50 Rev Time 0.00
Received By eschneid Date 2007-10-12 Time 14:50 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-11-22 Cont ID  
Sent By eschneid Date 2006-11-22 Time 15:23 Rev Time 0.00
Received By eschneid Date 2006-11-22 Time 15:22 Sent To I
Notes
2006-11-22 15:42:50PASSED W/PROVISO
  
 THE FOLLOWING SHEETS SHALL BE REVISED AND RESUBMITTED
 TO THE CONSTRUCTION SERVICES DEPARTMENT SHOWING THE ADA
 ROUTE FOR THE EASTERNMOST ACCESS AILSE IN THE FEDEX
 FREIGHT PARKING AREA:
  
 SHEET 3 OF 29
 SHEET 5 OF 29
 SHEET 6 OF 29
 SHEET 8 OF 29
 SHEET 19 OF 29
 SHEET 21 OF 29
  
 THESE SHEETS SHALL BE CORRECTED AND RESUBMITTED WITHIN
 20 WORKING DAYS OF THE APPROVAL OF THE PERMIT.
  
 CONTACT ERIC SCHNEIDER (561) 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-10-11 Cont ID  
Sent By eschneid Date 2006-10-11 Time 17:41 Rev Time 0.00
Received By eschneid Date 2006-10-11 Time 17:38 Sent To  
Notes
2006-10-11 17:40:51PLANS DO NOT MATCH PLANS APPROVED BY CITY COMMISSION.
 PLEASE NOTE THAT THE DISABLED SPACES FOR THE FEDERAL
 EXPRESS FREIGHT FACILITY NEED TO BE APPROVED BY THE
 CONSSTRUCTION SERVICES DEPARTMENT - THIS MAY REQUIRE A
 CHANGE IN PLANS.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-10-11 Cont ID  
Sent By eschneid Date 2006-08-22 Time 17:15 Rev Time 0.00
Received By eschneid Date 2006-08-22 Time 17:15 Sent To  
Notes
2006-08-22 00:00:00SITE PLAN HAS NOT BEEN APPROVED BY CITY
 COMMISSION.