Plan Review Details - Permit 06071651
Plan Review Stops For Permit 06071651
Review Stop G GAS REVIEW
Rev No 4 Status P Date 2007-08-23 Cont ID  
Sent By lmartine Date 2007-08-23 Time 17:44 Rev Time 0.00
Received By lmartine Date 2007-08-23 Time 17:44 Sent To  
Notes
2007-08-23 17:45:29SEE 06071649 FOR GAS APPROVAL

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2007-05-03 Cont ID  
Sent By mperson Date 2007-05-03 Time 10:36 Rev Time 0.00
Received By mperson Date 2007-05-03 Time 10:36 Sent To  
Notes
2007-05-03 10:37:46REFERENCE: GEN/RES PERMIT #06071649 GAS PLAN REVIEW.

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2006-09-15 Cont ID  
Sent By mperson Date 2006-09-15 Time 10:16 Rev Time 0.33
Received By mperson Date 2006-09-15 Time 10:16 Sent To  
Notes
2006-09-15 00:00:00REFERENCE: GEN/RES PERMIT #06071649

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-08-10 Cont ID  
Sent By mperson Date 2006-08-10 Time 15:45 Rev Time 0.45
Received By mperson Date 2006-08-10 Time 15:45 Sent To  
Notes
2006-08-10 00:00:00******DENIED******
 REFERENCE: FBC-2004 FUEL GAS
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR GAS PLAN REVIEW:
  
 1. MORE INFORMATION IS REQUIRED ON THE
 TYPE OF MATERIAL IS BEING USED ON THE
 ISOMETRIC GAS RISER. WHAT IS "CTS"?
 PLEASE CLARIFY FOR RESUBMITTAL.
 2. PER FBC-2004 FUEL GAS CODE SECS.
 401.8 THRU 402.6.1 AND TABLES 402.4(1)
 THRU 402.4(33): PLEASE INDICATE THE BTU
 LOAD OF THE GENERATOR ON THE ISOMETRIC
 DRAWING FOR RESUBMITTAL.
 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2. PLEASE
 SUBMIT MANUFACTURE CUT SHEETS FOR THE
 1ST AND 2ND STAGE REGULATORS.
 4. PLEASE INDICATE WHICH MODEL GENERATOR
 IS BEING USED SO BTU LOADS CAN BE
 VERIFIED.
 5. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 6. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON