| Plan Review Stops For Permit 06071631 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-08-16 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-08-16 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | ADDED EXT #0001 FOR THE UNIT 200 FOR THE | | | TENANT : AIRCRAFT SYSTEMS COMPANY LTD. | | | OWNER OF RECORD ON THE APPLICATION MUST | | | BE THE OWNER OF RECORD FROM THE PAPA AND | | | NOT THE TENANT NAME. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-16 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-16 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-03-16 13:58:07 | STAMP PLANS AND PRINT PERMIT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-02 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2007-03-02 14:32:12 | BUILDING PROVISO | | | 1) SPIRAL STAIRS SHALL COMPLY WITH 1009.9.2. | | | 1.THE CLEAR WIDTH OF THE STAIRS SHALL BE NOT LESS | | | THAN 26 INCHES (660 MM). | | | 2.THE HEIGHT OF THE RISERS SHALL NOT EXCEED 9- 1/2 | | | INCHES (241 MM). | | | 3.HEADROOM SHALL BE NOT LESS THAN 6 FEET 6 INCHES | | | (1981 MM). | | | 4.TREADS SHALL HAVE A DEPTH NOT LESS THAN 7-1/2 | | | INCHES (191 MM) AT A POINT 12 INCHES (305 MM) FROM THE | | | NARROWER EDGE. | | | 5.ALL TREADS SHALL BE IDENTICAL. | | | 6.HANDRAILS COMPLYING WITH SECTION 1009.11 SHALL | | | BE PROVIDED ON BOTH SIDES OF THE SPIRAL STAIRWAY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-11-30 |
Time |
07:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-11-30 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2006-11-30 09:00:05 | DENIED BY BUILDING | | | | | | 1) THE OWNER INFORMATION IS REQUIRED TO BE CORRECTED | | | WITH THE CITY RECORDS BEFORE A PERMIT WILL BE ISSUED. | | | SUBMIT A COPY OF THE WARRANTY DEED OR OTHER PROOF OF | | | OWNERSHIP TO THE FRONT COUNTER SO THAT THE OWNER CAN BE | | | UPDATED ON THE SYSTEM. | | | | | | 2) THE NOC THAT WAS SUBMITTED HAS THE WRONG PROPERTY | | | CONTROL NUMBER AND DOES NOT HAVE THE RECORDING STAMP ON | | | IT. PLEASE SUBMIT A RECORDED COPY OF THE NOC WITH THE | | | CORRECT INFORMATION ON IT. | | | | | | 3) IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY,THE | | | PLANS MUST BE STAMPED BY THEM AND A COPY OF THE PALM | | | BEACH COUNTY PAID RECIEPT FOR THE IMPACT FEES MUST BE | | | SUBMITTED BEFORE A PERMIT CAN BE ISSUED. ACCORDING TO | | | THE BUILDING PLAN EXAMINER, S. HILL, FOR THE ORIGINAL | | | STRUCTURE, IMPACT FEES WERE PAID FOR TWO MEZZANIES AND | | | THEY HAVE ALREADY BEEN CONSTRUCTED. THEREFORE, IMPACT | | | FEES ARE REQUIRED FOR ALL ADDITIONAL MEZZANIES ARE | | | CONSTRUCTED. | | | | | | 4)THE SPIRAL EGRESS STAIRS AT THE MEZZANINE ARE | | | REQUIRED TO COMPLY WITH 2004 FBC 1009.9.2. HANDRAILS | | | ARE REQUIRED ON BOTH SIDES, ETC. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2006-08-15 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2006-08-15 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2006-08-15 00:00:00 | DENIED BY BUILDING | | | | | | 1)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SPECIFY THE OCCUPANCY AND | | | CONSTRUCTION TYPE ON THE PLANS. | | | | | | 4) SPECIFY IF THE BUILDING IS | | | SPRINLERED. IF SPRINKLERED THE SPACE | | | ABOVE AND BELOW THE MEZZANINE IS | | | REQUIRED TO BE SPRINKLERED. | | | | | | 5) SPECIFY ON THE PLANS THAT THE | | | MEZZANINE IS A STORAGE OCCUPANCY WHICH | | | IS LOCATED WITIN A BUSINESS OCCUPANCY. | | | | | | 6) SPIRAL STAIRS IN A MEANS OF EGRESS | | | MUST COMPLY WITH FBC 1009.9.1. SEE FBC | | | 1032.2. PROVIDE DETAILS ON SIGNED AND | | | SEALED PLANS. | | | | | | 7) FBC 110.4.3* (CITY AMENDMENTS) | | | REQUIRES THE OWNER TO POST A SIGN WITH | | | THE SAFE ALLOWABLE FLOOR LOAD STATED IN | | | A CONSPICUOUS PLACE. | | | | | | 8) THE ENGINEER'S AFFIDAVIT FOR THE SAFE | | | FLOOR LOAD REQUIRED BY FBC 110.4.2* HAS | | | BEEN ALTERED. THE COVERSHEET FOR THE | | | LOAD CALCULATIONS REQUIRED BY FBC | | | 110.4.2 HAS BEEN ALTERED. THE FLOOR | | | LOAD, DIMENSIONS AND AREA HAVE BEEN | | | ALTERED ON SHEET A1 OF THE PLANS. | | | SOMEONE HAS DRAWN IN THE CLEAR HEIGHT | | | ABOVE THE MEZZANINE AND INCORRECT | | | OCCUPANCY. SIGNED AND SEALED DOCUMENTS | | | CAN NOT BE ALTERED. ONLY THE PERSON | | | SIGNING AND SEALING THE DOCUMENTS CAN | | | MAKE CHANGES. | | | | | | 9) PROVIDE A FLOOR PLAN OF THE UNIT | | | SHOWING THE DIMENSIONS AND ANY BUILDOUT | | | IN THE UNIT. THE AREA ALLOWED FOR THE | | | MEZZANINE IS BASED ON THE AREA OF THE | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | SEE FBC 505.2. | | | | | | 10) THE CLEAR HEIGHT ABOVE AND BELOW THE | | | MEZZANINE FLOOR CONSTRUCTION SHALL NOT | | | BE LESS THAN 7 FEET PER FBC 505.1. | | | | | | 11) SPECIFY THE WELD TYPE ON SHEET A1 | | | WHERE THE STEEL ANGLE IS WELDED TO THE | | | EMBEDS. | | | | | | 12) ADDITIONAL COMMENTS MAY RESULT WHEN | | | THESE COMMENTS ARE ADDRESSED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-04-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-14 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-14 |
Time |
08:48 |
Sent To |
PC |
|
| Notes |
| 2007-04-14 08:59:20 | REDLINED, CONTROL FOR LIGHTING OF STAIRS STILL REQUIRED | | | AT UPPER LEVEL. IN THE EVEN THE LIGHTING IS OFF, AN | | | OCCUPANT CAN TURN ON LIGHTING ATTHE UPPER FLOOR FOR | | | EGRESS OF STAIRS. | | | LS 101 7.8 AND 7.9 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-14 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-14 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2007-03-14 10:02:13 | REDLINED, | | | STILL MUST SUPPLY CONTROL FOR LIGHTING AT THE MEZZ/2ND | | | LEVEL FOR EGRESS. LS 101 7.8 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-02 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-02 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2007-03-02 18:20:28 | *** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PREVIOUS NOTES. PLEASE PROVIDE | | | MINIMUM LIGHTING LEVELS PER LIFE SAFETY CODE. NFPA-101 | | | 7.8.1.3, 7.9.2.2. | | | LIGHTING FOR CONTROL OF LIGHTS TO BE AT THE UPPER | | | LOCATION OF STAIRS FOR EGRESS AND LOWER PORTION OF | | | STAIRS. | | | | | | 2) NOTE: PLEASE SEE 13-415.1.1, .1.2, AND .1.3 | | | AUTOMATIC LIGHTING CONTROL SHUT OFF FOR NEW UPSTAIRS | | | AREA REQUIRED. | | | THIS IS A NEW NOTE AND CONFIRMED WITH THE STATE. | | | | | | ** NOTE # 2 COULD BE REDLINED ON PLANS WITH REVISION TO | | | FOLLOW, HOWEVER PLEASE SEE NOTE #1 IS MINIMUM NEEDED | | | FOR LIFE SAFETY. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-16 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-16 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2006-11-16 11:51:32 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SUBMIT A PLAN/DETAIL FOR THE REQUIRED | | | LIGHTING UNDER NORMAL AND EMERGENCY FOR NEW STORAGE | | | AREA EGRESS. THE SHEETS AS SUBMITTED DO NOT COMPLY AND | | | DO NOT PROVIDE ENOUGH INFORMATION FOR THE SAGE LIGHTING | | | ILLUMINATION OF THESE NEW STAIRS AS SHOWN. | | | PLEASE ALSO ONLY SUBMIT PLANS, AND INFORMATION FOR NEW | | | AREA AND STAIRS. | | | | | | THIS IS REQUIRED AT THIS TIME. | | | FBC ADMIN SECT(S) 106.1.2, 106.3.5.1.2,AND LIFE | | | SAFETY CODE 101 2003, 7.8.1.3, 7.9.2.2. | | | | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. * | | | *IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE | | | NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO | | | NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-11 |
Time |
21:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-11 |
Time |
21:01 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE PROVIDE MINIMUM EGRESS | | | LIGHTING AND CONTROLS FOR STAIR AREAS. | | | PLEASE SEE MIN REQUIRMENTS PER | | | 2003 NFPA-1017.8.1.3, 7.9.2.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-15 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-15 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2007-03-15 18:29:40 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN SATISFIED.PLAN SHEET FP-1 STAMPED, INITIALED, | | | AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-06 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-06 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2007-03-06 12:48:08 | *****INCOMPLETE***** | | | | | | | | | 1.EVEN THOUGH YOU ACKNOWLEDGED THAT J.W. FIRE | | | SPRINKLER HAS OR WILL SUBMIT SEPARATE PLANS FOR THIS | | | JOB, A LAYOUT OF THE PROPOSED FIRE SPRINKLER IS | | | REQUIRED FOR THIS REVIEW. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-12 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-12 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2006-12-12 16:55:00 | *****DENIED***** | | | | | | | | | | | | *THEPREVIOUS FIRE PLAN REVIEW OF 08/24/06HAS NOT | | | BEEN ADDRESSED. | | | | | | *TO EXPEDITE THE FIRE PLAN REVIEW PROCESS, INCLUDE A | | | RESPONSE INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED. | | | | | | *IT IS ASSUMED THAT THE SUBMITTED SPRINKLER PLANS WERE | | | DUE TO A MODIFICATION NEEDED FOR THE SCOPE OF WORK. | | | HOWEVER, THE UNIT NUMBER OF THE STRUCTURE IS NOT | | | INCLUDED IN THE TITLE BLOCK OF THE PLANS. ADDITIONALLY, | | | SEPARATE PERMIT AND PLAN WILL BE REQUIRED FOR THE | | | SPRINKLER REMODEL. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-08-24 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-08-24 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2006-08-24 00:00:00 | DENIED:******************** | | | | | | 1) THE MEANS OF EGRESS SHALL BE | | | ACCORDANCE WITH CHAPTER 7 AND CHAPTER | | | 39. | | | | | | 2) SPIRAL STAIRS SHALL COMPLY WITH | | | CHAPTER 7.2.2.2.3. | | | | | | 3) PLEASE PROVIDE A CLEAR REPRESENTATION | | | OF THE MEZZANINE STRUCTURE IN RELATION | | | TO THE FLOOR PLAN. | | | | | | 4) HOW WILL THIS MEZZANINE IMPACT THE | | | EXISTING FIRE SPRINKLER AND FIRE ALARM | | | SYSTEM. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2007-04-12 14:06:55 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-14 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-14 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2007-03-14 09:17:57 | TO "BOB"#10 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2007-03-01 14:08:01 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-07 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-07 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2006-11-16 11:41:47 | TO "BOB"#3 | | 2006-11-07 16:20:41 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-09-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | TO "BOB"#10 | | 2006-08-02 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-09-05 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-09-05 |
Time |
12:09 |
Sent To |
|
|
| Notes |
|
|