Plan Review Details - Permit 06071445
Plan Review Stops For Permit 06071445
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2006-07-28 Cont ID  
Sent By lursu Date 2006-07-28 Time 08:24 Rev Time 0.00
Received By lursu Date 2006-07-26 Time 08:16 Sent To  
Notes
2006-07-28 00:00:00PROJECT UNDER REVIEW!COMMENTS : UNITY OF
 TITLE IS NECESSARY BEFORE ASSIGNING AN
 ADDRESS FOR THE ENTIRE PARKING LOT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2006-08-25 Cont ID  
Sent By rchokshi Date 2006-08-25 Time 09:12 Rev Time 0.00
Received By rchokshi Date 2006-08-25 Time 08:49 Sent To  
Notes
2006-08-25 00:00:00FAILED FOR FOLLOWING REASONS:
  
 1.NEED DRAINAGE CALCULATIONS. HOW YOU
 ARE GOING TO TAKE CARE OF STORM WATER?
 2. NEED AT LEAST 10 FEET GRASS AROUND
 THE SITE BORDER WITH SWAILE IN THE
 MIDDLE 10 FEET TO RETAIN WATER FOR
 ABSORPTION. PERVIOUS, IMPERVIOUS AREAS.
 3. NEED CENTER LINE OF THE THE ROAD
 ELEVATION, SIDE WALK ELEVATION, FLOOR
 ELEVATION ETC.,( SURVEY MAP). PARKING
 LOT FLOOR ELEVATION MUST MEET FL
 BUILDING CODE.
  
 RASIK CHOKSHI 805-6723

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-22 Cont ID  
Sent By adarroug Date 2006-08-22 Time 14:48 Rev Time 0.00
Received By adarroug Date 2006-08-22 Time 14:48 Sent To ENG
Notes
2006-08-22 00:00:00TO "ENG" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-12 Cont ID  
Sent By adarroug Date 2006-08-12 Time 16:19 Rev Time 0.00
Received By adarroug Date 2006-08-12 Time 16:19 Sent To B
Notes
2006-08-12 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2006-07-27 Time 09:56 Sent To  
Notes
2006-07-27 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-09 Cont ID  
Sent By kdfreema Date 2006-08-09 Time 09:48 Rev Time 0.00
Received By kdfreema Date 2006-08-09 Time 09:48 Sent To  
Notes
2006-08-09 00:00:00THE LANDSCAPE BUFFERS PROVIDED ARE
 INSUFFICIENT.
  
 BUFFERS FOR THIS PROPERTY ARE REQUIRED
 AS FOLLOWS:
  
 NORTH SIDE: 10 FEET
 EAST SIDE: 5 FEET
 SOUTH SIDE: 5 FEET
 WEST SIDE: 5 FEET
  
 A LANDSCAPE PLAN, SIGNED AND SEALED BY A
 REGISTERED LANDSCAPE ARCHITECT IS
 REQUIRED. ALL PORTIONS OF THE BUFFER
 SHALL BE COVERED WITH GRASS, GROUND
 COVER, SHRUBBERY, MULCH, OR OTHER
 SUITABLE LIVE PLANT MATERIAL. THE
 LANDSCAPE BUFFER SHALL ALSO INCLUDE AT
 LEAST ONE SHADE OR FLOWERING TREE
 PLANTED FOR EACH 30 LINEAR FEET OR
 PORTION THEREOF. TREES PLANTED ALONG THE
 SOUTH LOT LINE MUST BE VISIBLE FROM THE
 OTHER SIDE OF THE WALL/FENCE BECAUSE
 RESIDENTIAL USES LIE TO THE IMMEDIATE
 SOUTH OF THE PROPERTY. REQUIRED HEDGES
 SHALL BE PLANTED AT TWO TO THREE FOOT
 INTERVALS TO SCREEN PARKING AREAS.
  
 A WALL OR FENCE A MINIMUM OF 5 FEET IN
 HEIGHT MUST BE PROVIDED ALONG THE ENTIRE
 LENGTH OF THE SOUTH PROPERTY LINE.
  
 SEE SEC. 94-443 OF THE CITY OF WEST PALM
 BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS FOR FURTHER INFORMATION ON
 LANDSCAPING REQUIREMENTS.
  
 PLEASE CONTACT KELLY FREEMAN, PLANNER AT
 561-822-1435 WITH QUESTIONS.
  
 PRE AND POST-DEVELOPMENT DRAINAGE
 CALCULATIONS WILL NEED TO BE SUPPLIED.
 THE DRAINAGE MUST ALSO PROVIDE FOR
 ON-SITE TREATMENT OF 1" OF RUNOFF.
  
 STORMWATER QUESTIONS SHOULD BE ADDRESSED
 TO STEVE SARLEY 561-494-1040.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved