| Plan Review Stops For Permit 06071436 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
N |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-01 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-01 |
Time |
14:20 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-09 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-09 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2006-11-09 14:43:23 | SEPERATE PERMIT REQUIRED FOR FENCING |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-10 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-10 |
Time |
10:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-10 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-10 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2007-04-10 11:33:55 | ** NEEDS NEW RE-RECORDED NOC ONCE PERMIT IS READY FOR | | | ISSUANCE. THE NOC HAS EXPIRED PER FS 713.13(2). | | | | | | ** REDLINED PLANS. | | | | | | ATS IS SE RATED AS SUBMITTED ON SPECS AND TAPS SHOULD | | | BE MADE ON THE LOAD SIDE OF THE MAIN FOR AIC RATING | | | PROTECTION OF MAIN. 110.9. | | | STAMP FOR ELEC ONLY. | | | NEEDS GAS AND ZONING REVIEWS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-21 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-21 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2006-11-21 14:49:31 | *** UNSAT2ND REVIEW *** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW AND | | | PLEASE SUBMIT TWO COMPLETED SETS FOR REVIEW. PLEASE | | | REMOVE ALL SHEETS WHICH ARE NOT RELEVANT TO THIS SCOPE | | | OF WORK BEING DONE. | | | PLEASE SEE NO REVISED RISER DIAGRAM COULD BE LOCATED. | | | IT IS NO CLEAR WHICH SETS ARE TO BE REVIEWED AS WHAT | | | APPEARS TO BETHE NEW SETS ARE NOT COMPLETE WITH | | | INFORMATION WHICH IS NEED FROM THE PREVIOUS NOTES OR | | | PREVIOUS PLANS. | | | | | | FBC 106.1.2, 106.1.3, ADMIN SECTION. | | | | | | 2) NOTE: PLEASE BE SURE MAKE PHOTO-COPIES OF ANY PLANS | | | WHICH ARE DRAWN IN PEN OR PENCIL. PLEASE KNOW WE CAN | | | NOT ACCEPT PLANS DONE LIKE THIS AS CHANGES CAN BE | | | READILY DONE. | | | FBC 106.1.3. | | | | | | 3) NOTE: PLEASE SEE BASED ON THE NEW CONTRACT VALUE | | | SUBMITTED, ADDITIONAL FEES WILL BE OWED | | | | | | | | | ** ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | *IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE | | | NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO | | | NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-08-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-09 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-09 |
Time |
17:36 |
Sent To |
|
|
| Notes |
| 2006-08-09 00:00:00 | ***** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE THE 2002 NEC. | | | 225.31-225.39, 230.72, 240.4, 310.16, | | | 408.16, 408, 250.110, 250.122, 250.24B, | | | 240.21 ETC | | | PLEASE SEE THERE ARE MANY ITEMS MISSING | | | AND/OR ARE NOT SHOWN FOR CODE | | | COMPLIANCE. | | | PLEASE VERIFY THE RISER WITH EQUIPMENT | | | WHICH IS BEING SHOWN FOR USE. PLEASE SEE | | | OCP ON GEN, RATINGS OF EQUIPMENT, | | | MISSING DISCONNECTING MEANS FOR FEEDERS | | | FROM GEN (MAY NOT USE BRKR ON UNIT), | | | CONDUCTORS SIZING, EQUIPMENT USED AS | | | RACEWAYS, GTOUNDING/EQUIPMENT GORUNDING | | | CONDUCTORS. ETC. | | | | | | 2) NOTE: PLEASE SEE NEC 220 FOR LOAD | | | CALCULATIONS WHICH ARE TO BE COMPLETED | | | PER NEC. THE RESIDENTIAL USE IS NOT | | | CLEAR AT THIS TIME, HOWEVER IN ANY CSE | | | PLEASE COMPLETE ELECTRICAL CALCULATIONS | | | FOR COMMERICAL LOADS ETC. | | | 220.3,220.10,220.13,220.11 ETC | | | PLEASE SEE 215.3,230.42 ETC | | | | | | 3) NOTE: PLEASE SEE RESIDENTIAL PANEL IS | | | SHOWING AN AHU#9??? WHERE IS 1-8? | | | NONE COULD BE LOCATED ON THESE PANEL | | | SCHEDULE EXCEPT FOR TWO.?? | | | | | | 4) NOTE: PLEASE PROVIDE A LAYOUT OF ALL | | | SERVICE EQUIPMENT. PLEASE PROVIDE AN | | | OVERVIEW AS THE ONLY EQUIPMENT SHOWN WAS | | | THE EXISTING 800A MAIN. | | | | | | 5) NOTE: PLEASE SEE ATS NEEDS TO BE | | | HIGHLIGHTED ON SPECS FOR WHICH ONE IS | | | BEING USED. PLEASE KNOW AS PER NOTES | | | ABOVE, THE ATS THE WAY IT IS SHOWN DOES | | | NOT MEET CODE. | | | | | | 6) NOTE: PLEASE SEE ALL PLANS, DESIGNS | | | AND LOAD CALULATIONS SHALL CONTAIN A | | | STATEMENT" DRAWN BY: PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPSOSIBLE FOR | | | SAID PLANS AND DESIGNS. | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE PROVIDE COPY OF CONTRACT | | | FOR COMPLETE SCOPE OF WORK FOR THIS | | | PERMIT. PLEASE SEE FBC 108.3 WHICH | | | REQUIRES VALUE FOR ALL LABOUR AND | | | MATERIALS EVEN IF ANY EQUIPMENT IS OWNER | | | SUPPLIED. PLEASE KNOW, THE MARSHALL'S | | | /SWIFT GUIDE MAY BE USED IN VALUATIONS | | | BY THIS OFFICE AS ADOPTED BY THE FBC | | | 2004. | | | | | | ** UNABLE TO DO A COMPLETE REVIEW AT | | | THIS TIME. | | | PLEASE BE SURE TO GO OVER PLANS AND | | | RISER BEFORE RESUBMITTING. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-12-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-12-29 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-12-29 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2006-12-29 13:24:37 | ***PROVISO*** | | | | | | 1) IF THE POSSIBILITY OF MECHANICAL DAMAGE EXISTS WITH | | | REGARDS TO THE LOCATION OF THE GENERATOR, PROTECTIVE | | | BARRIERS MAY NEED TO BE INSTALLED. | | | | | | 2) PLEASE CLARIFY WHAT BUILDING EQUIPMENT WILL BE | | | IMPACTED UNDER POWER OF THE GENERATOR. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | (561) 805-6722 OR 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-01 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-01 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | ***PROVISO*** | | | | | | 1) WORK SHALL COMPLY WITH NFPA 110, | | | STANDARD FOR EMERGENCY AND STANDBY POWER | | | SYSTEMS. | | | | | | 2) PLEASE SUBMIT ALL APPLICABLE | | | MANUFACTURER SPEC SHEETS FOR EQUIPMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-05-29 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-05-29 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2007-05-29 08:30:03 | SEPARATE GAS PERMIT REQUIRED | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) - (SITE | | | PLAN INDICATES NATURAL, BUT GAS TYPE IS | | | REQUIRED ON ISOMETRIC). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. MANUF | | | SHEETS SUBMITTED DO NOT SHOW | | | INSTALLATION INSTRUCTIONS NOR DO THEY | | | INDICATE MINIMUM CLEARANCES FROM | | | STRUCTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-21 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-21 |
Time |
18:20 |
Sent To |
|
|
| Notes |
| 2006-08-21 00:00:00 | SEPARATE GAS PERMIT REQUIRED | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR THE GAS PERMIT: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL) - (SITE | | | PLAN INDICATES NATURAL, BUT GAS TYPE IS | | | REQUIRED ON ISOMETRIC). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | | | 7. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. MANUF | | | SHEETS SUBMITTED DO NOT SHOW | | | INSTALLATION INSTRUCTIONS NOR DO THEY | | | INDICATE MINIMUM CLEARANCES FROM | | | STRUCTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-18 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-18 |
Time |
14:18 |
Sent To |
Z |
|
| Notes |
| 2007-06-18 14:18:29 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-02 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-02 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2007-04-04 17:16:34 | TO COMM BOARD # 49 | | 2007-04-02 18:17:38 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-04 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-04 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2006-11-07 14:31:01 | TO "COMM" BD#1 | | 2006-11-04 18:35:23 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-01 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-27 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2006-08-09 00:00:00 | TO "COMM" BD#51 | | 2006-07-27 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-11 |
Time |
06:55 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-11 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | NATURAL GAS GENERATOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-07-17 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-07-17 |
Time |
18:35 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-04-19 |
Time |
19:30 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-04-19 |
Time |
19:30 |
Sent To |
I |
|
| Notes |
| 2007-04-20 15:58:33 | PLANNING AND ZONING DEPARTMENT:*** FAILED*** | | | 4-19-07 COMMENTS WERE NOT ADDRESSED. | | | | | | 1.PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2.PURSUANT TO SECTION 94-444(B) PROVIDE APPROPRIATE | | | SCREENING, WHICH INCLUDES WALLS WITH LANDSCAPING. | | | REVISE ACCORDINGLY. ALSO, SUBMIT ELEVATIONS OF THE | | | GENERATOR SHOWING THE SCREENING | | | REQUIREMENTS. | | | | | | 3.IS THE GENERATOR PROPOSED ON THE SIDE OF THE ROAD? | | | PROVIDE WIDTH OF THE ROADWAY TO MAKE SURE CLEARANCE FOR | | | CARS IS THERE. | | | | | | 4.THE SITE PLAN SHOWS PARKING THAT IS NO LONGER PART | | | OF THE STORAGE FACILITY.PLEASE CONTACT STAFF BELOW TO | | | DISCUSS SURVEY, ORIGINAL APPROVAL FOR THIS COMMERCIAL | | | PLANNED DEVELOPMENT, ETC.THERE ARE DISCREPANCIES IN | | | THE ORIGINAL APPROVAL AND WHAT WAS ACTUALLY BUILT. | | | | | | IF YOU HAVE ANY QUESTIONS,PLEASE CONTACT ME AT THE | | | NUMBER BELOW. | | | | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-11-17 |
Time |
20:06 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-11-17 |
Time |
20:06 |
Sent To |
I |
|
| Notes |
| 2006-11-17 20:16:10 | PLANNING AND ZONING DEPARTMENT:***** FAILED ****** | | | | | | 1.PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2.PURSUANT TO SECTION 94-444(B) PROVIDE APPROPRIATE | | | SCREENING, WHICH INCLUDES WALLS WITH LANDSCAPING. | | | REVISE ACCORDINGLY. ALSO, SUBMIT ELEVATIONS OF THE | | | GENERATOR SHOWING THE SCREENING REQUIREMENTS. | | | | | | 3.IS THE GENERATOR PROPOSED ON THE SIDE OF THE ROAD? | | | PROVIDE WIDTH OF THE ROADWAY TO MAKE SURE CLEARANCE FOR | | | CARS IS THERE. | | | ALTHOUGH SITE PLAN WAS SUBMITTED IN RE-SUBMITTAL | | | PACKET.IT DOES NOT ADDRESS THE LAST CONVERSATION I | | | HAD WITH THE APPLICANT.THE SITE PLAN SHOWS THE AREA | | | WHERE THE PROPOSED GENERATOR IS TO BE PLACED, AS A | | | TWO-WAY ROADWAY.PROVIDE GENERATOR, SCREENING (FENCE | | | AND LANDSCAPE) TO SCALE ON SITE PLAN AND SHOW HOW THE | | | MANEUVERING OF VEHICLES WILL TAKE PLACE IN THE | | | IMMEDIATE AREA.PROPER MANEUVERING FOR VEHICLES TO | | | TURN AROUND NEED TO BE SHOW IN THIS AREA.STAFF | | | SUGGESTED THE GENERATOR TO BE PLACED IN AN AREA THAT | | | WAS NOT ON THE ROADWAY ACCESS, SUCH AS THE NORTHWEST | | | CORNER WHERE BLDG. A AND "L SHAPE" BUILDING MEET. | | | | | | 4.A SEPARATE PERMIT APPLICATION FOR THE FENCE NEEDS | | | TO BE SUBMITTED TO CONSTRUCTION SERVICES FOR THE | | | SCREENING OF THE GENERATOR. | | | | | | | | | IF YOU HAVE ANY QUESTIONS,PLEASE CONTACT ME AT THE | | | NUMBER BELOW. | | | | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-08-28 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-08-28 |
Time |
18:03 |
Sent To |
I |
|
| Notes |
| 2006-08-28 00:00:00 | PLANNING AND ZONING DEPARTMENT:FAILED | | | | | | 1.PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2.PURSUANT TO SECTION 94-444(B) | | | PROVIDE APPROPRIATE SCREENING, WHICH | | | INCLUDES WALLS WITH LANDSCAPING.REVISE ACCORDINGLY. | | | ALSO, SUBMIT ELEVATIONS OF | | | THE GENERATOR SHOWING THE SCREENING | | | REQUIREMENTS. | | | | | | 3.IS THE GENERATOR PROPOSED ON THE | | | SIDE OF THE ROAD?PROVIDE WIDTH OF THE | | | ROADWAY TO MAKE SURE CLEARANCE FOR CARS | | | IS THERE. | | | | | | IF YOU HAVE ANY QUESTIONS,PLEASE | | | CONTACT ME AT THE NUMBER BELOW. | | | | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 | | | |
|
|