| Plan Review Stops For Permit 06071373 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-02-20 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-02-16 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2007-02-20 09:38:52 | THE SITE ADDRESS AND THE PARCEL CONTROL NUMBER ARE | | | CORRECT. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | 2007-02-16 09:08:11 | NEED TO COORDINATE PARCEL ID NUMBER AND CORRECT LOT AND | | | ADDRESS. | | | ALSO, COORDINATE WITH PALM BEACH COUNTY RECORDS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-02-16 |
Time |
09:08 |
Rev Time |
2.00 |
| Received By |
jgomez |
Date |
2007-02-15 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2007-02-16 08:06:12 | BUILDING REVIEWCHECKLIST: | | | | | | 1- NEED TO PASS ALL THE OTHER TRADES: MECHANICAL AND | | | PLUMBING. SEE PLAN REVIEWERS COMMENTS. | | | | | | 2- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS. | | | NOTE: THERE IS NOT FL240. NEED TO PROVIDE ANOTHER | | | PRODUCT APPROVAL.ALSO, PROVIDE A COMPLETE | | | INSTALLATION SCHEDULE. SEE ATTACHED SAMPLE.COMPLETE | | | ALL INFORMATIONOR PROVIDE ALL THE REQUIRED | | | INFORMATION IN ANOTHER FORMAT THAT WILL PROVIDE ALL | | | REQUIRED INFORMATION FOR PLAN REVIEW. | | | | | | 3- GARAGE DOOR PRODUCT APPROVAL IS MISSINGDESIGNER OF | | | RECORD APPROVAL IN WRITTING AS REQUIRED BY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC 2004.RESUBMIT. | | | | | | 4- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC. | | | R401.3 2004 FLORIDA RESIDENTIAL CODE. | | | | | | 5- MISSING NOTICE OF COMMENCEMENT. | | | | | | 6- CHECK WITH PALM BEACH COUNTY FOR CORRECT PARCEL ID | | | NUMBER AND LOT NUMBER.ACCORDING TO PAPA RECORDS IT | | | LOOKS LIKE THE LOT WAS REPLATTED. PROVIDE REVISED | | | SURVEY WITH CURRENT INFORMATION.CALLLILY URSU. | | | (561)822-1239FROM CITY OF WEST PALM BEACH ADDRESSING | | | SECTION TO GET CORRECT INFORMATION. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-10-26 |
Time |
17:27 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2006-10-25 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2006-10-26 17:38:45 | BUILDING REVIEW 2ND CHECKLIST: | | | | | | 1- ENERGY CALCULATIONS:REVISE INFORMATION ON TOP OF | | | FORM.NEED CORRECT ADDRESS,NAME OF BUILDER AND | | | PERMITTING OFFICE. | | | | | | 2- ENGINEER TO CLARIFY WHY ARE THERE 2 DIFFERENT ZIP | | | CODES ON HIS ADDRESS. SEE ADDRESS ON DRAWING TITLE | | | BLOCK (33314)AND ADDRESS ON RUBBER STAMP (33440) . | | | WHICH ONE IS THE CORRECT ONE. REVISE AS REQUIRED. | | | | | | 3- PROVIDE FLORIDA OR LOCAL PRODUCT APPROVAL AS | | | REQUIRED BY DCA RULE 9B-72 FOR: | | | A) SINGLE HUNG WINDOWS. DADE COUNTY NOA #05-0112.01 | | | SUBMITTED EXPIRED ON 10/08/06. NEED CURRENT ONE. | | | ***NOTE: ENGINEER OF RECORD TO REVIEW AND APPROVE | | | CURRENT NOA. | | | B) PRECAST CONCRETE LINTELS. | | | ***NOTE: ENGINEER TO REVIEW IT AND APPROVE IT AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 4- CLARIFY WHY EDGE DETAIL FOR GARAGE AND SHOWER STEP | | | DOWN SHOW NO REINFORCEMENT.SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 5- SHEET T1: | | | A) SPECIFY CONNECTORS AT THE ENDS OF DOUBLE 2X12 | | | WOOD BEAM WHEN RESTING ON THE MASONRY WALL. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | B) REVISE STRUCTURAL NOTE #3.STAPLEWITH 7/8 LEGS | | | IS NOT ALLOWED. SEE ASTM C926 AND ASTM C1063. NEED MIN. | | | 1 3/4" PENETRATION INTO THE THE TRUSS. REVISE AS | | | REQUIRED. | | | | | | 6- STORM SHUTTERS: | | | A) THERE ARE 2 DIFFERENT PRODUCT APPROVALS | | | SUBMITTED. SUBMIT ONLY ONE TYPE. | | | B) IF USING FLORIDA PRODUCT APPROVAL FL240, THEN | | | PROVIDE FLORIDA COVER PAGE FOR 2004 VERSION. GO TO | | | WWW.FLORIDABUILDING.ORG TO DOWNLOAD ALL INFORMATION. | | | | | | C) IF USING FL5870, THEN MARK ON DRAWINGS SPECIFIC | | | ANCHOR TYPE AND SPACING TO BE USED AS DONE WITH | | | DRAWINGS FOR FL240. TO VERIFY COMPLIANCE WITH PRODUCT | | | APPLICATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | D) PLEASE MAKE SURE ALL DRAWINGS ARE CLEAR AND | | | LEGIBLE. | | | | | | ***NOTE: PLEASE MAKE SURE SELECTED PRODUCT IS REVIEWED | | | AND APPROVED BY THE ENGINEER OF RECORD. | | | | | | 7- CONTRACTOR TO UPDATE WORKERS COMPENSATIONAND | | | LICENSE INFORMATION WITH PERMIT CLERK. | | | | | | 8- TRUSS LAYOUT SUBMITTED. NEED COMPLETE TRUSS PACKAGE | | | INCLUDING THE INDIVIDUAL TRUSSES. THIS INFORMATION NEED | | | NO BE SUBMITTED NOW, BUT IT NEEDS TO BE SUBMITTED FOR | | | REVIEW PRIOR TO INSTALLATION. SEE SEC. R802.10 FOR | | | REQUIRED INFORMATION TO BE SUBMITTED. | | | | | | 9- INDICATE ON SITE PLAN (OR SURVEY) HOW COMPLIANCE | | | WITH SEC. R401.3 2004 FLORIDA RESIDENTIAL CODE IS | | | ACHIEVED. | | | | | | 10- ALL DRAWINGS NEED TO HAVE THE ADDRESS OF PROPOSED | | | PROJECT. | | | | | | 11- NOTICE OF COMMENCEMENT IS EXPIRED AFTER 90 DAYS OF | | | BEING RECORDED IF WORK IS NOT STARTED. NEED RE-RECORDED | | | NOTICE OF COMMENCEMENT. SEC. 713.13(2) FLORIDA | | | STATUTES. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-10-16 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-10-16 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2006-10-16 13:44:31 | RECEIVED ONLY THE SHUTTERS INFORMATION. CALLED | | | CONTRACTOR TO FIND OUT WHY PACKAGE WAS SPLIT. | | | CONTRACTOR SAY DRAWINGS ARE IN ZONING. HOLDING SHUTTERS | | | PAKCAGE TILL GETTING PLANS BACK. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-04 |
Time |
16:46 |
Rev Time |
2.50 |
| Received By |
jgomez |
Date |
2006-08-04 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2006-08-04 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- ENERGY CALCULATIONS: | | | A) OWNER/AGENT TO SIGN AND DATE BOTTOM | | | OF FORM. | | | B) COMPLETE ALL INFORMATION ON TOP OF | | | FORM, INCLUDING ADDRESS OF HOUSE. | | | C) PROVIDE 2 COPIES OF ENERGY | | | CALCULATIONS FOR GUEST HOUSE. ONLY ONE | | | SUBMITTED. | | | | | | 2- THERE ARE 2 DIFFERENT ZIP CODES ON | | | ENGINEER'S ADDRESS. REVISE AS REQUIRED. | | | | | | 3- SPECIFY SAFETY GLASS AT: | | | A) LIVING ROOM WINDOW NEXT TO ENTRY | | | DOOR. | | | B) GARAGE WINDOW NEXT TO SWING DOOR. | | | SECTION R308.4 2004 RESIDENTIAL CODE. | | | | | | 4- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL AS REQUIRED BY DCA RULE 9B-72 | | | FOR: | | | A) SINGLE HUNG WINDOWS. DADE COUNTY NOA | | | #02-0419.13 SUBMITTED EXPIRED ON FEB. | | | 25, 2006. | | | B) ALL TRUSS CONNECTORS AND STRUCTURAL | | | CONNECTORS SPECIFIED ON PLANS & DETAILS. | | | C) PRECAST CONCRETE LINTELS. | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND | | | APPROVE IN WRITTING ALL PRODUCT | | | APPROVALS AS REQ'D BY SEC. 106.3.3 OF | | | CITY AMENDMENTS TO FBC 2004. | | | | | | 6- PROVIDE 2 COPIES OF SOIL TEST REPORT | | | WITH ENGINEER'S ORIGINAL SEAL AND | | | SIGNATURE AS REQ'D BY CHAPTER 471 FL. | | | ST. AND SEC. 61G15-23.002. ONLY ONE | | | SUBMITTED. THE OTHER ONE IS A COPY. | | | | | | 7- SHEET #2: | | | A) CONCRETE BLOCK COLUMN DETAIL: REVISE | | | NUMBER OF NAILS FOR CONNECTOR META16. | | | SEE CURRENT SIMPSON CATALOGUE FOR | | | CORRECT NUMBER AND SIZE OF OF NAILS. | | | B) REVISE SIZE OF CONCRETE PAD SHOWN ON | | | CONCRETE BLOCK COLUMN DETAIL TO MATCH | | | SIZE SPECIFIED ON FOUNDATION PLAN. | | | C) PROVIDE EDGE DETAIL FOR SHOWER AND | | | GARAGE CONCRETE SLAB RECESS. SECTION | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 8- SHEET #3: | | | A) SPECIFY CALCULATED UPLIFT LOADS AND | | | ALL CONNECTORS FOR DOUBLE 2X12 WOOD BEAM | | | AT ENTRY PORCH. (CONNECTIONS AT THE ENDS | | | OF BEAM, CORNER JOINT, ETC). SECTION | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | B) STRUCTURAL NOTE #3: REVISE SIZE OF | | | FASTENER. FASTENER NEEDS TO HAVE 1 3/4" | | | MIN. EMBEDMENT INTO THE TRUSS. SECTION | | | R703.6 2004 RESIDENTIAL CODE AND ASTM | | | C926 AND ASTM C1063. | | | C) TRUSS ANCHOR SCHEDULE: | | | * CONNECTOR "G": REVISE NUMBER OF NAILS. | | | SEE CURRENT SIMPSON CATALOGUE. | | | ** CONNECTOR "M": SPECIFY SPECIFIC SIZE | | | OF CONNECTOR. REVISE NUMBER OF NAILS. | | | REVISE LATERAL LOADS. SEE CURRENT | | | SIMPSON CATALOGUE AND REVISE AS REQ'D. | | | *** CONNECTOR "O": REVISE NUMBER OF | | | NAILS. SEE SIMPSON CATALOGUE. | | | D) DESIGN CRITERIA: ASCE 7-02 IS THE | | | EDITION USED IN FBC 2004. NOT ASCE 7-98. | | | REVISE AS REQUIRED. | | | E) PROVIDE ONLY THE DETAILS THAT APPLY | | | TO THIS JOB TO EXPEDITE THE REVIEW | | | PROCESS & AVOID CONFUSIONS OR CONFLICTS. | | | | | | 9- SHEET D-1: | | | A) UPDATE NOTE #1. SEE SEC. R402.2 2004 | | | RESIDENTIAL CODE FOR REFERENCED | | | STANDARDS TO BE USED. | | | B) UPDATE REFERENCE ON NOTE #18. SEE | | | R806 2004 RESIDENTIAL CODE. | | | C) REVISE SIZE OF SOFFIT VENT ON NOTE | | | #19 TO MATCH SIZE SPECIFIED ON WALL | | | SECTION. | | | D) REVISE NOTE #22: SEE R401.4 OF 2004 | | | RESIDENTIAL CODE FOR CORRECT CODE | | | REFERENCE. | | | E) PROVIDE ONLY THE DETAILS THAT APPLY | | | TO THIS JOB TO EXPEDITE REVIEW PROCESS | | | AND AVOID CONFUSION OR CONFLICTS. | | | | | | 10- COMMENTS FOR MAIN HOUSE ALSO APPLY | | | TO GUEST HOUSE. REVISE SHEET #2 AND | | | SHEET D-1 OF GUEST HOUSE. SEE COMMENTS | | | ABOVE. | | | | | | 11- STORM SHUTTERS: PROVIDE KEY PLAN AND | | | COMPLETE INSTALLATION SCHEDULE. SEE | | | ATTACHED SAMPLE OF INSTALLATION SCHEDULE | | | AND PROVIDE ALL INFORMATION REQUESTED. | | | | | | 12- CONTRACTOR TO UPDATE WORKER | | | INSURANCE INFORMATION WITH PERMIT CLERK | | | SPECIALIST WHEN RESUBMITTING PERMIT | | | APPLICATION. | | | | | | 13- PLEASE RETURN SHEET #1 WITH THE | | | IMPACT FEES STAMP AFTER CORRECTIONS ARE | | | DONE ON ORIGINAL DRAWINGS. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-31 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-31 |
Time |
07:57 |
Sent To |
M |
|
| Notes |
| 2007-01-31 12:57:17 | CATV AND PHONES ARE NOT INCLUDED AND WILL BE REQUIRED | | | TO BE UNDER SEPARATE PERMIT PLANS AND FEES AT A LATER | | | DATE BEFORE INSTALLATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-23 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-23 |
Time |
18:00 |
Sent To |
M |
|
| Notes |
| 2006-10-23 18:18:06 | *** UNSAT 2ND REVIEW ** | | | | | | ** PLEASE SEE MANY NOTES FROM PREVIOUS REVIEW ARE NOT | | | ADDRESSED AND CANE NOT BE REVIEWED AT THIS TIME FOR | | | CODE COMPLIANCE. | | | | | | | | | | | | 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS FOR | | | REWVIEW. PLEASE SEE SOME SHEETS HAVEOTHER SHEETS AND | | | INFORMATION TAPED ONTO PLANS?? | | | PLEASE SEE SOME SETS CONTAIN AND HOUSE PLANS, YET NO | | | GUEST HOUSE PLANS, AND OTHER SETS CONTAIN GUEST HOUSE | | | BUT NO MAIN HOUSE?? | | | | | | 2) NOTE: PLEASE SEENOTES 1,2,3,5,6,7,8,9,10 FROM | | | PREVIOUS REVIEW. | | | FBC 106.3.5.4(8), | | | PLEASE ALSO SEE FS 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS FOR CODE COMPLIANCE. | | | THIS IS ONLY ANOTICE GIVEN AT THIS TIME. | | | | | | ** PLEASE SEE NEC 2002 FOR CODE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-26 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-26 |
Time |
09:42 |
Sent To |
Z |
|
| Notes |
| 2006-07-26 00:00:00 | *******UNSAT ************ | | | | | | 1) NOTE: PLEASE SEE MISSING RECEPT FOR | | | WHAT APPEARS TO BE MORE THAN 2 FT OF | | | WALL IN MAIN HOUSE. | | | | | | 2) NOTE: PLEASE COMPLETE PANEL SCHEDULES | | | TO INDICATE ALL SPECIFYOED AREAS AND | | | RMS. IE; LIV RM TLS, DINING RECEPTS , | | | BEDRM #1 RECEPTS ETC. | | | 408.4,240.4,310.16 | | | | | | 3) NOTE: PLEASE SEE PANEL FOR MAIN HOUSE | | | IS NOT ON PLANS., 110.26,240.24 ETC | | | PLEASE ALSO SHOW SERVICE AND LOCATION OF | | | SERVICE. PLEASE SEE NOTES FOR GUEST | | | HOUSE ALSO AS MAINS DO NOT APPEAR TO BE | | | GROUPED ETC. | | | PLEASE SEE 230.70,230.72,225.31-225.39 | | | PLEASE SEE MISSING DISCONNECTING MEANS | | | AT GUEST HOUSE. RISER SHOWS A DISCONNECT | | | HOWEVER IT IS NOT SHOWN ON PLANS WHERE | | | THIS ITS. | | | | | | 4) NOTE: PLEASE SEE MISSING GROUNDING | | | ELECTRODE SYSTEM AT GUEST HOUSE PER | | | 250.32, 250.50 | | | | | | 5) NOTE: PLEASE CORRELATE PLANS AS GUEST | | | HOUSE SHOWS 60A PANEL, AND RISER SHOWS | | | 100A ALONG WITH PANEL SCHEDULE. | | | PLEASE SEE LOAD SHOWN EXCEEDS THE RATING | | | OF THE 60A PANEL. | | | 2404.310.16 | | | 106.1.2 FBC | | | | | | 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 7) NOTE: PLEASE VERIFY THE 60A OCP SHOWN | | | FO THE 7.5KW HEAT IN GUEST HOUSE. | | | | | | 8) NOTE: PLEASE SEE DINING RM SHALL BE | | | ON ONE OR MORE OF THE SMALL APPLIANCE | | | CIRCUITS. PLEASE SEE IF DINING IS ON | | | THEIR OWN, PLEASE SEE 210.52B1,210.11C1 | | | AND 220.16 AS THE THESE SHALL BE FIGURED | | | AS 1500 VA. | | | | | | 9) NOTE: PLEASE SEE NFPA-72 11.8.3 FOR | | | SD'S LOCATED WITHIN 20' OF COOKING | | | EQUIPMENT. | | | | | | 10) NOTE: PLEASE CLARIFY IF THEIR ARE | | | GONG TO BE LAUNDRY FACILITIES IN GUEST | | | HOUSE.? | | | | | | ** PLEASE SEE ANY POSSIBLE ZONING | | | COMMENTS WHICH MAY AFFECT PLANS. | | | | | | ** BEFORE AND WHEN RESUBMITTING PLANS, | | | PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | SUBMIT ONE COPY OF THE OLD/VOIDED SHEETS | | | FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-23 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-23 |
Time |
09:58 |
Sent To |
M |
|
| Notes |
| 2007-03-23 09:59:11 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-29 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-29 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2007-01-29 14:28:22 | TO "DPALMER" DESK/RESUB--EXPEDITED PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-24 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-24 |
Time |
10:25 |
Sent To |
Z |
|
| Notes |
| 2007-01-24 10:26:20 | TO 5TH FL ZONING BOX/RESUB--NEW SHEETS FOR "Z"EXPEDITED | | | PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-23 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-23 |
Time |
15:32 |
Sent To |
E |
|
| Notes |
| 2006-10-23 15:33:04 | TO "DPALMER"DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-14 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-14 |
Time |
16:58 |
Sent To |
B |
|
| Notes |
| 2006-10-14 16:59:12 | TO "JGOMEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-29 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-29 |
Time |
13:59 |
Sent To |
Z |
|
| Notes |
| 2006-09-29 00:00:00 | TO "Z" BOX/RESUB--EXPEDITED PERMIT-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-04 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-07-25 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2006-07-25 00:00:00 | TO "SFR" "Z"-EXPEDITED PERMIT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
14:46 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
14:46 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-01 |
Time |
08:11 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-02-01 |
Time |
08:11 |
Sent To |
P |
|
| Notes |
| 2007-02-01 08:24:45 | *** DENIED *** | | | | | | 1) AS NOTED IN LAST REVIEW 10-24-07 NOTE #2, MECHANICAL | | | PLANS FOR MAIN GUEST HOUSE, NEED JOB ADDRESS ON THEM. | | | | | | 2) AS NOTED IN LAST REVIEW 10-24-07 NOTE #3, THE A/C | | | SYSTEM FOR THE MAIN HOUSE IS OVER-SIZED, THE MAIN HOUSE | | | MANUAL J CALCULATIONS ARE CALLING FOR 19,578 SENSIBLE | | | BTU'S, THE MECHANICAL PLANS ARE CALLING FOR 33,322 | | | SENSIBLE BTU'S, THE PLANS CAN ONLY CALL FOR 20% MORE | | | THAN THE MANUAL J CAL'S, PER 2004 FBC 13-607.1.ABC.1.1, | | | PLEASE CORRECT. | | | | | | 3) SEE MAIN HOUSE MECH. PLAN, 12"RETURN AIR TRANSFER | | | DUCT TO MASTER SUITE IS TO SMALL. BALANCED RETURN AIR | | | MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, | | | EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL | | | BE INCLUDED. PER 2004 FBC/R M1602.4. | | | | | | 4) PLEASE SHOW ON MECHANICAL PLANS WERE THE CLOTHES | | | DRYER VENT WILL TERMINATE (VENT MAY NOT DISCHARGE NEAR | | | A/C CONDENSER UNIT). | | | | | | 5) SEE MECHANICAL PLANS TO MAIN HOUSE, WHITE-OUT MAY | | | NOT BE USED ON PLANS, AND DO NOT SUBMIT CHANGES IN PEN. | | | PLEASE MAKE COPY'S AFTER CHANGES HAVE BEEN MADE AND | | | SUBMIT COPY'S. | | | | | | 6) ONE SET OF PLANS TO MAIN HOUSE HAS TWO DIFFERENT | | | MECHANICAL PLANS, PLEASE REMOVE ONE. | | | | | | 7) SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-24 |
Time |
11:37 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-24 |
Time |
11:37 |
Sent To |
P |
|
| Notes |
| 2006-10-24 11:55:21 | *** DENIED *** | | | 1) MECHANICAL PLANS NEED THE NAME AND SIGNATURE OF THE | | | DESIGN PERSON ON THEM, FOR MAIN HOUSE AND COTTAGE. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE | | | FOR THE DESIGN. PER FBC 104.2.1 . | | | | | | 2) SEE MECHANICAL PLANS FOR MAIN HOUSE AND COTTAGE, | | | NEED JOB ADDRESS ON THEM. | | | | | | 3) THE MAIN HOUSE MANUAL J CALCULATIONS ARE CALLING FOR | | | 13,909 TOTAL SENSIBLE BTU'S, THE MECH. PLANS ARE | | | CALLING FOR 33,322 TOTAL SENSIBLE BTU'S, THE PLANS CAN | | | ONLY CALL FOR 20% MORE THAN THE MANUAL J CAL'S, PRE | | | 2004 FBC 13-607.1.ABC.1.1, PLEASE CORRECT. | | | | | | 4) SEE MAIN HOUSE MECH. PLAN, PLEASE SHOW SIZE OF THE | | | SUPPLY AIR DUCTS GOING TO THE TWO BATHROOMS. | | | | | | 5) SETS OF PLANS ARE MIXED-UP PAGES FOR THE COTTAGE ARE | | | IN WITHTHE SET FOR THE MAIN HOUSE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-04 |
Time |
14:34 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-08-04 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
| 2006-08-04 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS HAVE TO MUCH FLOOR | | | PLAN DETAIN ON THEM AND ARE DIFFICULT TO | | | READ. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | . | | | | | | 2) SHOW A/C EQUIPMENT LISTING WITH ALL | | | THE PERTINENT INFORMATION ON THE | | | MECHANICAL PLANS. | | | | | | 3) THE MECHINACLE PLANS NEED THE | | | ENGINEER"S SEAL ON THEM DUE TO HIS NAME | | | AND INFORMATION IS IN THE TITLE BLOCK, | | | PER FAC 61G15-23.002 . | | | | | | 4) ENERGY CALCULATIONS NEED TO BE SIGNED | | | BY OWNER/AGENT ALSO, PER 2004 FBC | | | 13-600.3.ABC.2 | | | | | | 5) ENERGY CALCULATIONS NEED THE ADDRESS, | | | AND JURISDICTION NUMBER ON THEM. | | | | | | 6) NEED TWO COPY'S OF ENERGY CAL'S FOR | | | THE GUEST SUITE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-30 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-30 |
Time |
07:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-12 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-12 |
Time |
07:50 |
Sent To |
B |
|
| Notes |
| 2007-02-12 08:00:43 | DENIED; | | | 1. WATER HEATER REQUIRED TO HAVE THERMAL EXPANSION | | | PROTECTION, SECTION 607.3 SHOW ON PLANS. | | | 2. ADD NOTE TO PLANS THAT AREDUCED PRESSURE PRINCIPAL | | | BACKFLOW PREVENTOR IS REQUIRED AT THE WATER METER. | | | 3. AN AUTOMATIC CLOTHES WASHER HOOKUP IS REQUIRED IN | | | THE GUEST HOUSE. TABLE 403.1 (7 R3) UNDER OTHER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-25 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-25 |
Time |
14:40 |
Sent To |
B |
|
| Notes |
| 2006-10-25 14:49:35 | DENIED; | | | COMMENTS NOT ADDRESSED ON LAST REVIEW; | | | 1. QUEST HOUSE NOT ON SANITARY RISER DIAGRAM (2ND | | | REQUEST) | | | 2. WATER SEVICE ONE METER OR TWO SHOW ON PLANS. IF | | | ONE METER A BACKFLOW PREVENTER IS REQUIRED. (2ND | | | REQUEST) | | | 3. OK | | | 4.THERMAL EXPANTION CONTROL REQUIRED ON WATER HEATERS | | | IF BACKFLOW PREVENTOR IS INSTALLED (2ND REQUEST) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-26 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-26 |
Time |
12:59 |
Sent To |
Z |
|
| Notes |
| 2006-07-26 00:00:00 | DENIED; | | | 1.PLEASE INCLUDE GUEST HOUSE ON THE | | | PLUMBING SANITARY RISER DIAGRAM. | | | 2.IS WATER SERVICE OFF ONE METER? IF SO | | | A BACKFLOW PREVENTOR IS REQUIRED TO BE | | | INSTALLED AT WATER METER. | | | 3.IS WATER HEATER IN MAIN HOUSE THE HOT | | | WATER SUPPY FOR THE GUEST HOUSE? IF SO | | | PLEASE SHOW ON PLAN THE DISTANCE FROM | | | WATER HEATER TO LAST FIXTURE IN GUEST | | | HOUSE. IF 100' A METHOD OF MAINTAINING | | | THE TEMPERATURE IN ACCORDANCE WITH | | | CHAPTER 13 OF THE FBC-2004. | | | 4.IF A BACKFLOW IS INSTALLED IN THE | | | WATER SYSTEM SYSTEM THEN A MEANS OF | | | THERMAL EXPANSION SHELL BE REQUIRED | | | PLEASE SHOW ON DRAWINGS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2007-01-29 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2007-01-29 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2006-10-23 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2006-10-23 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2006-08-04 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2006-08-03 |
Time |
10:51 |
Sent To |
M |
|
| Notes |
| 2006-08-04 00:00:00 | THE FOLLOWING RECOMMENDATIONS ARE | | | STRONGLY ADVISED FOR THE IMPROVEMENT OF | | | THE ARCHITECTURE AND THE INTERIOR | | | ENVIRONMENT. | | | | | | MAIN HOUSE | | | ALL ELEVATIONS: | | | 1.MAINTAIN THE SAME WINDOW PROPORTIONS | | | (3'X5') IN ALL ROOMS EXCEPT KITCHEN AND | | | BATHS. | | | | | | FRONT ELEVATION: | | | 1.FLATTEN OR REMOVE ARCHES AT PORCH IN | | | ORDER TO FULLY REVEAL WINDOWS. | | | 2. PROVIDE A BASE AND CAPITAL FOR THE | | | COLUMNS. | | | | | | INTERIOR LIVING ENVIRONMENTS: | | | 1. ADD WINDOW TO LEFT ELEVATION AT | | | BEDROOM #1 TO PROVIDE CROSS VENTILLATION | | | AND IMPROVE THE AESTHETICS OF THELEFT | | | FACADE. | | | 2. EITHER CENTER THE WINDOW IN THE WALL | | | FOR BEDROOM #2 OR ADD AN ADDITIONAL | | | WINDOW FOR IMPROVED LIGHT AND | | | VENTILLATION. | | | 3. ADD WINDOW IN MASTER BEDROOM AT RIGHT | | | ELEVATION TO PROVIDE CROSS VENTILLATION | | | ANDIMPROVE THE AESTHETICS OF THE RIGHT | | | FACADE. | | | 4. CONSIDER REDUCING ROOF PITCH TO 3:12 | | | TO IMPROVE THE MASSING OF THE HOUSE. | | | | | | GUEST HOUSE | | | 1. CENTER WINDOW IN BEDROOM #1 TO | | | IMPROVE FRONT ELEVATION. | | | 2. ADD AN ADDITIONAL WINDOW IN THE | | | LIVING ROOM AT THE FRONT ELEVATION TO | | | IMPROVE FRONT FACADE. | | | 3. ADD ADDITIONAL WINDOW IN LIVING ROOM | | | AT LEFT ELEVATION TO IMPROVE LEFT | | | FACADE. | | | 4. ADD WINDOWS TO REAR ELEVATION. A | | | BLANK FACADE IS UNACCEPTABLE. | | | 5. CHANGE WINDOW IN BEDROOM #1 TO A | | | SINGLE UNIT IN FAVOR OF ADDING WINDOWS | | | AT FRONT AND LEFT ELEVATIONS. | | | 6. MAINTAIN WINDOW PROPORTIONS THROUGHT | | | THE HOUSE WHENEVER IT'S POSSIBLE. | | | | | | PLEASE SCHEDULE A MEETING WITH AMY | | | STELLY IN THE URBAN DESIGN DIVISION TO | | | DISCUSS THE ARCHITECTURE. 822-1440 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-27 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-27 |
Time |
14:30 |
Sent To |
M |
|
| Notes |
| 2006-07-27 00:00:00 | DENIED, | | | 1. THE PROPOSED WALKWAY & DRIVEWAY WILL | | | EXCEED THE LANDSCAPE REQUIREMENTS. | | | PLEASE PROVIDE THE DIMENSION OF THE | | | PROPOSED WALKWAY.CAN HAVE A TOTAL OF | | | 12.5SQ FT OF CONCRETE WITHIN THE FRONT | | | SETBACK (THIS WILL INCLUDE DRIVEWAY & | | | WALKWAY). | | | | | | NOTE:MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE, WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | 2. MUST PROVIDE ADDITIONAL PARKING FOR | | | THE PROPOSED GUEST HOUSE. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|