Plan Review Details - Permit 06071370
Plan Review Stops For Permit 06071370
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2007-02-20 Cont ID  
Sent By lursu Date 2007-02-20 Time 09:19 Rev Time 0.00
Received By lursu Date 2007-02-20 Time 09:19 Sent To  
Notes
2007-02-20 09:20:36SITE ADDRESS IS CORRECT.SINGLE HOUSE IS NOT PART OF THE
 MERRY PL DEVELOPMENT.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-02-16 Cont ID  
Sent By jgomez Date 2007-02-16 Time 18:55 Rev Time 0.00
Received By jgomez Date 2007-02-16 Time 18:31 Sent To  
Notes
2007-02-16 18:56:17BUILDING REVIEWCHECKLIST:
  
 1- NEED TO PASS ALL THE OTHER TRADES: MECHANICAL AND
 PLUMBING. SEE PLAN REVIEWERS COMMENTS.
  
 2- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS.
 NOTE: THERE IS NOT FL240. NEED TO PROVIDE ANOTHER
 PRODUCT APPROVAL.ALSO, PROVIDE A COMPLETE
 INSTALLATION SCHEDULE. SEE ATTACHED SAMPLE.COMPLETE
 ALL INFORMATIONOR PROVIDE ALL THE REQUIRED
 INFORMATION IN ANOTHER FORMAT THAT WILL PROVIDE ALL
 REQUIRED INFORMATION FOR PLAN REVIEW.
  
 3- MISSINGGARAGE DOOR PRODUCT APPROVAL.AND,
 DESIGNER OF RECORD TO APPROVE IT IN WRITTING AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 4- PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC.
 R401.3 2004 FLORIDA RESIDENTIAL CODE.
  
 5- MISSING NOTICE OF COMMENCEMENT.
  
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-31 Cont ID  
Sent By jgomez Date 2006-10-30 Time 14:11 Rev Time 0.00
Received By alange Date 2006-10-31 Time 11:47 Sent To  
Notes
2006-10-31 11:51:55DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 5.PRODUCT APPROVALS REQUIRED FOR LINTELS.
  
 6.INCORRECT STATE PRODUCT APPROVAL PAGES SUBMITTED
 FOR OWENS CORNING AND THERMA TRU IS MISSING STATE
 PRODUCT APPROVAL.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
 TRUSS DRAWING REQUIRED TO BE APPROVED
 PRIOR TO INSTALLATION.
  
 9.ENTRY SECTION, SHOW METHOD OF
 ATTACHEMENT OF HEADERS TO COLUMN.
  
 10.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A
 STORM SEWER CONVEYANCE OR OTHER APPROVED
 POINT OF COLLECTION SO AS TO NOT CREATE
 A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION
 WALLS. THE GRADE AWAY FROM FOUNDATION
 WALLS SHALL FALL A MINIMUM OF 6 INCHES
 WITHIN THE FIRST 10 FEET.
  
 NEW COMMENT:
 REAR COVERED PORCH IS IN DIFFERENT LOCATIONS ON PLANS.
 PLEASE SHOW ONLY AT ONE LOCATION ON PLANS AND SURVEY.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-08 Cont ID  
Sent By astelly Date 2006-08-08 Time 09:09 Rev Time 2.66
Received By alange Date 2006-08-08 Time 09:09 Sent To  
Notes
2006-08-08 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF
 THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.HAND DRAWN CHANGES NOT PERMITTED ON
 PLANS.
  
 3.SOILS REPORTS SUBMITTED ARE NOT
 ORIGONAL SIGNED AND SEALED DOCUMENTS.
 SUBMIT TWO ORIGONALS.
  
 4.SIGN OWNER/AGENT ON ENERGY CALCS PER
 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR 8FT.
 OVERHEAD DOOR AND LINTELS.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
 TRUSS DRAWING REQUIRED TO BE APPROVED
 PRIOR TO INSTALLATION.
  
 9.ENTRY SECTION, SHOW METHOD OF
 ATTACHEMENT OF HEADERS TO COLUMN.
  
 10.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A
 STORM SEWER CONVEYANCE OR OTHER APPROVED
 POINT OF COLLECTION SO AS TO NOT CREATE
 A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION
 WALLS. THE GRADE AWAY FROM FOUNDATION
 WALLS SHALL FALL A MINIMUM OF 6 INCHES
 WITHIN THE FIRST 10 FEET.
  
 11.WIND DESIGN CRITERIA SHOULD BE ASCE
 7-02.
  
 12.CODE SECTIONS USED ARE STILL UNDER
 THE 2001 FBC CODE SECTIONS USED SHOULD
 RERFLECT THE 2004 FLORIDA RESIDENTIAL
 CODE.
 SEE FOUNDATION AND CONCRETE NOTES #18
 AND #22 ... ATTIC VENTILATION IS R-806
 AND SOIL BEARING IS R-401.4.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-01-31 Cont ID  
Sent By dpalmer Date 2007-01-31 Time 13:08 Rev Time 0.00
Received By dpalmer Date 2007-01-31 Time 13:08 Sent To M
Notes
2007-01-31 13:08:24CATV AND PHONES ARE NOT INCLUDED AND WILL BE REQUIRED
 TO BE UNDER SEPARATE PERMIT PLANS AND FEES AT A LATER
 DATE BEFORE INSTALLATION.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-10-23 Cont ID  
Sent By dpalmer Date 2006-10-23 Time 19:28 Rev Time 0.00
Received By dpalmer Date 2006-10-23 Time 19:25 Sent To M
Notes
2006-10-23 19:29:14** UNSAT 2ND REVIEW **
  
 ** PLEASE SEE MANY NOTES FROM PREVIOUS REVIEW ARE NOT
 ADDRESSED AND CANE NOT BE REVIEWED AT THIS TIME FOR
 CODE COMPLIANCE.
  
  
  
 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS FOR
 REWVIEW. PLEASE SEE SOME SHEETS HAVEOTHER SHEETS AND
 INFORMATION TAPED ONTO PLANS??
 PLEASE SEE SOME SETS CONTAIN AND HOUSE PLANS, YET NO
 GUEST HOUSE PLANS, AND OTHER SETS CONTAIN GUEST HOUSE
 BUT NO MAIN HOUSE??
  
 2) NOTE: PLEASE SEENOTES 1,2,3,5,6,7,8,9,10 FROM
 PREVIOUS REVIEW.
 FBC 106.3.5.4(8),
 PLEASE ALSO SEE FS 553.80(2)(B) WITH RESPECT TO REPEAT
 COMMENTS FOR CODE COMPLIANCE.
 THIS IS ONLY ANOTICE GIVEN AT THIS TIME.
  
 ** PLEASE SEE NEC 2002 FOR CODE.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-26 Cont ID  
Sent By dpalmer Date 2006-07-26 Time 11:52 Rev Time 0.00
Received By dpalmer Date 2006-07-26 Time 11:51 Sent To Z
Notes
2006-07-26 00:00:00*******UNSAT ************
  
 1) NOTE: PLEASE SEE MISSING RECEPT FOR
 WHAT APPEARS TO BE MORE THAN 2 FT OF
 WALL IN MAIN HOUSE.
  
 2) NOTE: PLEASE COMPLETE PANEL SCHEDULES
 TO INDICATE ALL SPECIFYOED AREAS AND
 RMS. IE; LIV RM TLS, DINING RECEPTS ,
 BEDRM #1 RECEPTS ETC.
 408.4,240.4,310.16
  
 3) NOTE: PLEASE SEE PANEL FOR MAIN HOUSE
 IS NOT ON PLANS., 110.26,240.24 ETC
 PLEASE ALSO SHOW SERVICE AND LOCATION OF
 SERVICE. PLEASE SEE NOTES FOR GUEST
 HOUSE ALSO AS MAINS DO NOT APPEAR TO BE
 GROUPED ETC.
 PLEASE SEE 230.70,230.72,225.31-225.39
 PLEASE SEE MISSING DISCONNECTING MEANS
 AT GUEST HOUSE. RISER SHOWS A DISCONNECT
 HOWEVER IT IS NOT SHOWN ON PLANS WHERE
 THIS ITS.
  
 4) NOTE: PLEASE SEE MISSING GROUNDING
 ELECTRODE SYSTEM AT GUEST HOUSE PER
 250.32, 250.50
  
 5) NOTE: PLEASE CORRELATE PLANS AS GUEST
 HOUSE SHOWS 60A PANEL, AND RISER SHOWS
 100A ALONG WITH PANEL SCHEDULE.
 PLEASE SEE LOAD SHOWN EXCEEDS THE RATING
 OF THE 60A PANEL.
 2404.310.16
 106.1.2 FBC
  
 6)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 7) NOTE: PLEASE VERIFY THE 60A OCP SHOWN
 FO THE 7.5KW HEAT IN GUEST HOUSE.
  
 8) NOTE: PLEASE SEE DINING RM SHALL BE
 ON ONE OR MORE OF THE SMALL APPLIANCE
 CIRCUITS. PLEASE SEE IF DINING IS ON
 THEIR OWN, PLEASE SEE 210.52B1,210.11C1
 AND 220.16 AS THE THESE SHALL BE FIGURED
 AS 1500 VA.
  
 9) NOTE: PLEASE SEE NFPA-72 11.8.3 FOR
 SD'S LOCATED WITHIN 20' OF COOKING
 EQUIPMENT.
  
 10) NOTE: PLEASE CLARIFY IF THEIR ARE
 GONG TO BE LAUNDRY FACILITIES IN GUEST
 HOUSE.?
  
 ** PLEASE SEE ANY POSSIBLE ZONING
 COMMENTS WHICH MAY AFFECT PLANS.
  
 ** BEFORE AND WHEN RESUBMITTING PLANS,
 PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS FROM SETS AND ONLY
 INSERT NEW REVISED SHEETS INTO TWO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 SUBMIT ONE COPY OF THE OLD/VOIDED SHEETS
 FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-03-23 Cont ID  
Sent By adarroug Date 2007-03-23 Time 10:22 Rev Time 0.00
Received By adarroug Date 2007-03-23 Time 10:22 Sent To M
Notes
2007-03-23 10:23:02TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-01-31 Cont ID  
Sent By adarroug Date 2007-01-29 Time 08:46 Rev Time 0.00
Received By adarroug Date 2007-01-29 Time 14:31 Sent To  
Notes
2007-01-29 14:32:23TO "DPALMER" DESK/RESUB--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-01-24 Cont ID  
Sent By adarroug Date 2007-01-24 Time 10:57 Rev Time 0.00
Received By adarroug Date 2007-01-24 Time 10:57 Sent To Z
Notes
2007-01-24 10:58:42TO 5TH FL ZONING IN-BOX--EXPEDITED PERMIT

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-23 Cont ID  
Sent By adarroug Date 2006-10-23 Time 15:32 Rev Time 0.00
Received By adarroug Date 2006-10-23 Time 15:32 Sent To E
Notes
2006-10-23 15:32:30TO "DPALMER"DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-14 Cont ID  
Sent By adarroug Date 2006-10-14 Time 16:48 Rev Time 0.00
Received By adarroug Date 2006-10-14 Time 16:48 Sent To B
Notes
2006-10-14 16:48:22TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-29 Cont ID  
Sent By adarroug Date 2006-09-29 Time 16:56 Rev Time 0.00
Received By adarroug Date 2006-09-29 Time 16:56 Sent To Z
Notes
2006-09-29 00:00:00TO "Z" BOX/RESUB--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-08 Cont ID  
Sent By alange Date 2006-08-08 Time 09:23 Rev Time 0.00
Received By alange Date 2006-07-25 Time 14:48 Sent To  
Notes
2006-07-25 00:00:00TO "SFR" "Z"--EXPEDITED PERMIT

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-03-28 Cont ID  
Sent By tgordon Date 2007-03-28 Time 11:53 Rev Time 0.25
Received By tgordon Date 2007-03-28 Time 11:53 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-01-31 Cont ID  
Sent By tgordon Date 2007-01-31 Time 15:44 Rev Time 0.45
Received By tgordon Date 2007-01-31 Time 15:44 Sent To P
Notes
2007-01-31 16:12:22*** DENIED ***
  
 1) AS NOTED IN LAST REVIEW 10-24-07 NOTE #2, MECHANICAL
 PLANS FOR MAIN HOUSE AND COTTAGE, NEED JOB ADDRESS ON
 THEM.
  
 2) AS NOTED IN LAST REVIEW 10-24-07 NOTE #3, THE A/C
 SYSTEM FOR THE MAIN HOUSE IS OVER-SIZED, THE MAIN HOUSE
 MANUAL J CALCULATIONS ARE CALLING FOR 19,783 SENSIBLE
 BTU'S, THE MECHANICAL PLANS ARE CALLING FOR 33,322
 SENSIBLE BTU'S, THE PLANS CAN ONLY CALL FOR 20% MORE
 THAN THE MANUAL J CAL'S, PER 2004 FBC 13-607.1.ABC.1.1,
 PLEASE CORRECT.
  
 3) AS NOTED IN LAST REVIEW 10-24-07 NOTE #4. SEE MAIN
 HOUSE MECH. PLAN, 12"RETURN AIR TRANSFER DUCT TO
 MASTER SUITE IS TO SMALL. BALANCED RETURN AIR MAY BE
 ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE
 RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR
 HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO
 ACHIEVE PROPER RETURN AIR BALANCE.
 (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET
 THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR
 EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY
 ROOMS,
 EXECPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE SHALL
 BE INCLUDED. PER 2004 FBC/R M1602.4.
  
 4) PLEASE SHOW ON MECHANICAL PLANS WERE THE CLOTHES
 DRYER VENT WILL TERMINATE (VENT MAY NOT DISCHARGE NEAR
 A/C CONDENSER UNIT).
  
 5) SEE MECHANICAL PLANS TO MAIN HOUSE, WHITE-OUT MAY
 NOT BE USED ON PLANS, AND DO NOT SUBMIT CHANGES IN PEN.
 PLEASE MAKE COPY'S AFTER CHANGES HAVE BEEN MADE AND
 SUBMIT COPY'S.
  
 6) SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR
 TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-10-24 Cont ID  
Sent By tgordon Date 2006-10-24 Time 13:34 Rev Time 0.30
Received By tgordon Date 2006-10-24 Time 13:34 Sent To P
Notes
2006-10-24 13:41:13*** DENIED ***
 1) MECHANICAL PLANS NEED THE NAME AND SIGNATURE OF THE
 DESIGN PERSON ON THEM, FOR MAIN HOUSE AND COTTAGE. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE
 FOR THE DESIGN. PER FBC 104.2.1 .
  
 2) SEE MECHANICAL PLANS FOR MAIN HOUSE AND COTTAGE,
 NEED JOB ADDRESS ON THEM.
  
 3) THE MAIN HOUSE MANUAL J CALCULATIONS ARE CALLING FOR
 14,200 TOTAL SENSIBLE BTU'S, THE MECH. PLANS ARE
 CALLING FOR 33,322 TOTAL SENSIBLE BTU'S, THE PLANS CAN
 ONLY CALL FOR 20% MORE THAN THE MANUAL J CAL'S, PRE
 2004 FBC 13-607.1.ABC.1.1, PLEASE CORRECT.
  
 4) SEE MAIN HOUSE MECH. PLAN, 10"RETURN AIR TRANSFER
 DUCT TO MASTER SUITE IS TO SMALL, PLEASE CORRECT, SEE
 NOTE #5.
  
 5)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By mmclean Date 2006-08-07 Time 11:38 Rev Time 0.45
Received By tgordon Date 2006-08-07 Time 11:38 Sent To B
Notes
2006-08-07 00:00:00*** DENIED ***
 1) MECHANICAL PLANS HAVE TO MUCH FLOOR
 PLAN DETAIL ON THEM AND ARE DIFFICULT TO
 READ. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY. PER 2004 FBC 106.1.1
 .
  
 2) THE MECHANICAL PLANS NEED TO BE
 SEALED BY THE ENGINEER AS HIS NAME AND
 INFORMATION IS IN THE TITLE BLOCK, PER
 FAC 61G15-23.002 (LOOK UP PLAGIARISM).
  
 3) ONE COPY OF THE ENERGY CALCULATIONS
 WERE SIGNED IN PENCIL BY THE PREPARER,
 DOCUMENTS MUST BE SIGNED IN PEN. AND
 SUBMIT TWO COPYS OF THE E-CAL'S FOR THE
 GUEST HOUSE.
  
 4) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2 .
  
 5) SHOW A EQUIPMENT LISTING WITH ALL
 PERTINENT INFORMATION ON THE MECHANICAL
 PLANS.
  
 6) SHOW CFM'S AT EACH SUPPLY AIR GRILL.
  
 7) SHOW LOCATION OF CLOTHES DRYER VENT TERMINATION, ON
 MECHANICAL PLANS.
  
 8) ALL RETURN AIR TRANSFER DUCTS ARE TO
 SMALL, SEE NOTE #9.
  
 9) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-03-29 Cont ID  
Sent By jleech Date 2007-03-29 Time 07:57 Rev Time 0.00
Received By jleech Date 2007-03-29 Time 07:49 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-02-12 Cont ID  
Sent By jleech Date 2007-02-12 Time 08:14 Rev Time 0.00
Received By jleech Date 2007-02-12 Time 08:14 Sent To B
Notes
2007-02-12 08:22:23DENIED;
 1. WATER HEATER REQUIRED TO HAVE THERMAL EXPANSION
 PROTECTION, SECTION 607.3. SHOW ON PLANS.
 2. ADD NOTE TO PLANS THAT A REDUCED PRESSURE PRINCIPAL
 BACKFLOW PREVENTOR IS REQUIRED AT THE WATER METER.
 3. AN AUTOMATIC CLOTHES WASHER HOOKUP IS REQUIRED IN
 THE GUEST HOUSE. SEE TABLE 403.1 (7 R3) UNDER OTHER.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-10-26 Cont ID  
Sent By jleech Date 2006-10-26 Time 11:56 Rev Time 0.00
Received By jleech Date 2006-10-26 Time 11:56 Sent To  
Notes
2006-10-26 12:12:41DENIED;
 COMMENTS FROM FIRST REVIEW;
 1. NO THERE IS NO RISER DIAGRAM ON NEW SET OF PLANS.
 2.SEPORATE WATER SERVICES AND METERS; PLEASE ADD A NOTE
 TO PLANS;
 SEPARATE WATER SERVICES AND METERS.
 3.WATER HEATERS UNKNOWN ONLY GUEST HOUSE FLOOR PLAN
 SHOWN ON PLANS.
 4. OK.
 NEW COMMENTS;
 PLANS ARE NOT COMPLETE. NO SANITARY RISER DIAGRAM. NO
 FLOOR PLAN FOR MAIN HOUSE.
 UNABLE TO DO A PLUMBING PLAN REVIEW.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-26 Cont ID  
Sent By jleech Date 2006-07-26 Time 14:28 Rev Time 0.00
Received By jleech Date 2006-07-26 Time 14:28 Sent To Z
Notes
2006-07-26 00:00:00DENIED;
 1.PLEASE INCLUDE GUEST HOUSE ON THE
 PLUMBING SANITARY RISER DIAGRAM.
 2.IS WATER SERVICE TO BOTH BUILDINGS
 FROM THE SAME METER IF SO A BACKFLOW
 PREVENTER IS REQUIRED TO BE INSTALLED AT
 THE WATER METER BY THE UTILITY
 DEPARTMENT.
 3.IS WATER HEATER IN MAIN HOUSE THE HOT
 WATER SUPPLY FOR THE BACK HOUSE? IF SO
 PLEASE SHOW ON THE PLANS THE DISTANCE
 FROM THE W/H TO THE LAST FIXTURE. IF
 100' A METHOD OF MAINTAINING THE
 TEMPERATURE IN ACCORDANC WITH CHAPTER 13
 OF THE FBC-2004 BUILDING CODE MUST BE
 INSTALLED.
 4.IF A BACKFLOW IS REQUIRED THEN A MEANS
 OF THERMAL EXPANSION SHELL BE REQUIRED.
 SEE SECTION 607.3. SHOW ON DRAWINGS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 4 Status N Date 2007-01-29 Cont ID  
Sent By astelly Date 2007-01-29 Time 13:39 Rev Time 0.00
Received By astelly Date 2007-01-29 Time 13:39 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-10-23 Cont ID  
Sent By astelly Date 2006-10-23 Time 08:59 Rev Time 0.00
Received By astelly Date 2006-10-23 Time 08:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2006-08-04 Cont ID  
Sent By astelly Date 2006-08-04 Time 14:54 Rev Time 0.00
Received By astelly Date 2006-08-04 Time 14:54 Sent To M
Notes
2006-08-04 00:00:00THE FOLLOWING RECOMMENDATIONS ARE
 STRONGLY ADVISED FOR THE IMPROVEMENT OF
 THE ARCHITECTURE AND THE INTERIOR
 ENVIRONMENT.
  
 MAIN HOUSE
 ALL ELEVATIONS:
 1.MAINTAIN THE SAME WINDOW PROPORTIONS
 (3'X5') IN ALL ROOMS EXCEPT KITCHEN AND
 BATHS.
 2.MAINTAIN CONSISTENCY WITH WINDOW
 CASINGS AND SILLS WITH ALL ELEVATIONS.
  
 FRONT ELEVATION:
 1.FLATTEN OR REMOVE ARCHES AT PORCH IN
 ORDER TO FULLY REVEAL WINDOWS.
 2. PROVIDE A BASE AND CAPITAL FOR THE
 COLUMNS.
  
 INTERIOR LIVING ENVIRONMENTS:
 1. ADD WINDOW TO LEFT ELEVATION AT
 BEDROOM #1 TO PROVIDE CROSS VENTILLATION
 AND IMPROVE THE AESTHETICS OF THELEFT
 FACADE. MOVE COVERED PORCH TO THE REAR
 OF THE MASTER BEDROOM AND CHANGE THE
 DOOR IN BEDROOM #1 TO A WINDOW. OR,
 EXTEND THE COVERED PORCH TO THE FULL
 LENGTH OF THE REAR FACADE AND MAINTAIN
 THE DOOR IN BEDROOM #1.
 2. CENTER THE WINDOW IN THE WALL
 FOR BEDROOM #2.
 3. ADD WINDOW IN MASTER BEDROOM AT RIGHT
 ELEVATION TO PROVIDE CROSS VENTILLATION
 ANDIMPROVE THE AESTHETICS OF THE RIGHT
 FACADE.
 4. CONSIDER REDUCING ROOF PITCH TO 3:12
 TO IMPROVE THE MASSING OF THE HOUSE.
  
 GUEST HOUSE
 1. CENTER WINDOW IN BEDROOM #1 TO
 IMPROVE FRONT ELEVATION.
 2. ADD AN ADDITIONAL WINDOW IN THE
 LIVING ROOM AT THE FRONT ELEVATION TO
 IMPROVE FRONT FACADE.
 3. ADD ADDITIONAL WINDOW IN LIVING ROOM
 AT LEFT ELEVATION TO IMPROVE LEFT
 FACADE.
 4. ADD WINDOWS TO REAR ELEVATION. A
 BLANK FACADE IS UNACCEPTABLE.
 5. CHANGE WINDOW IN BEDROOM #1 TO A
 SINGLE UNIT IN FAVOR OF ADDING WINDOWS
 AT FRONT AND LEFT ELEVATIONS.
 6. MAINTAIN WINDOW PROPORTIONS THROUGHT
 THE HOUSE WHENEVER IT'S POSSIBLE.
  
 INTERIOR ENVIRONMENT:
 1. THE DINETTE SPACE IS COMPROMISED BY
 HAVING 3 OPENNINGS AND 3 CIRCULATION
 PATHS CROSS THE AREA.
  
 PLEASE SCHEDULE A MEETING WITH AMY
 STELLY IN THE URBAN DESIGN DIVISION TO
 DISCUSS THE ARCHITECTURE. 822-1440

Review Stop Z ZONING
Rev No 1 Status F Date 2006-07-27 Cont ID  
Sent By mmclean Date 2006-07-27 Time 14:47 Rev Time 0.00
Received By mmclean Date 2006-07-27 Time 14:47 Sent To M
Notes
2006-07-27 00:00:00DENIED,
 1. THE PROPOSED WALKWAY & DRIVEWAY WILL
 EXCEED THE LANDSCAPE REQUIREMENTS.
 PLEASE PROVIDE THE DIMENSION OF THE
 PROPOSED WALKWAY.CAN HAVE A TOTAL OF
 12.5SQ FT OF CONCRETE WITHIN THE FRONT
 SETBACK (THIS WILL INCLUDE DRIVEWAY &
 WALKWAY).
  
 NOTE:MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 2. MUST PROVIDE ADDITIONAL PARKING FOR
 THE PROPOSED GUEST HOUSE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720+