Plan Review Details - Permit 06071139
Plan Review Stops For Permit 06071139
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-01 Cont ID  
Sent By mjacobs Date 2006-12-01 Time 14:34 Rev Time 0.00
Received By mjacobs Date 2006-12-01 Time 13:16 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-11-07 Cont ID  
Sent By mjacobs Date 2006-11-07 Time 10:46 Rev Time 0.00
Received By mjacobs Date 2006-11-07 Time 06:03 Sent To PC
Notes
2006-11-07 10:45:51BUILDING PLAN REVIEW
 PERMIT: 06071139
 ADD:641 34TH ST.
 CONT:JAMES SNYDER
 TEL: (561)827-1189
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)SUBMIT PRODUCT APPROVALS FOR THE DOUBLE DOORS OF
 THE STORAGE ROOM.) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-16 Cont ID  
Sent By mjacobs Date 2006-08-16 Time 17:40 Rev Time 0.00
Received By mjacobs Date 2006-08-15 Time 09:25 Sent To PC
Notes
2006-08-15 00:00:00 
 1) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS
 NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 2) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION. NEW LOCATION 2300 N.JOG RD
 (NORTH OF OKEECHOBEE BLVD)SUITE#2W01-
 2W14).
  
 3) ACCORDING TO THE SIMPSON STRONG-TIE
 CATALOG, THE WAY THE LS50 AND LS30
 CONNECTORS ARE SHOWN ON THE DRAWINGS, IS
 NOT HOW THEY WERE INTENDED TO BE USED.
 PLEASE SEE THE SIMPSON STRONG-TIE
 CATALOG FOR MORE INFORMATION AND
 INDICATE THE CORRECT CONNECTOR/STRAP FOR
 THE UPLIFT RESISTANCE.
  
 4) EXPLAIN WHY EIGHT PIECES OF PT 2X8
 ARE STACKED ON EACH OTHER TO BUILD UP
 THE COLUMS INSTEAD OF OTHER METHODS OF CONSTRUCTION.
 THE LIQUID NAILS WILL
 DETERIORATE OVER TIME AND THE STACKED
 PIECES WILL SHRINK AND CAUSE OTHER
 STRUCTURAL PROBLEMS IN DUE TIME. ONCE
 AGAIN THE LS50 SHOULD NOT BE USED AS A
 CONNECTOR FOR THE BEAM TIE-DOWN.
  
 5) FBC TABLE 2304.9.1 THE NAIL SPACING
 OF THE WALL AND FLOOR SHEATING SHALL BE
 6" O.C. EDGES AND INTERMEDIATE. 4" O.C.
 AT COMPONENT AND CLADDING EDGE STRIP #3.{FIG.1609.C}.
  
 6) R319.1 LOCATION REQUIRED.
 IN AREAS SUBJECT TO DECAY DAMAGE AS
 ESTABLISHED BY TABLE R301.2(1) , THE
 FOLLOWING LOCATIONS SHALL REQUIRE THE
 USE OF AN APPROVED SPECIES AND GRADE OF
 LUMBER, PRESSURE TREATED IN ACCORDANCE
 WITH AWPA C1, C2, C3, C4, C9, C15, C18,
 C22, C23, C24, C28, C31, C33, P1, P2 AND
 P3, OR DECAY -RESISTANT HEARTWOOD OF
 REDWOOD, BLACK LOCUST, OR CEDARS.
  
 7) R319.1.1 GROUND CONTACT.
 ALL WOOD IN CONTACT WITH THE GROUND AND
 THAT SUPPORTS PERMANENT STRUCTURES
 INTENDED FOR HUMAN OCCUPANCY SHALL BE
 APPROVED PRESSURE PRESERVATIVE TREATED
 WOOD SUITABLE FOR GROUND CONTACT USE,
 EXCEPT UNTREATED WOOD MAY BE USED WHERE
 ENTIRELY BELOW GROUNDWATER LEVEL OR
 CONTINUOUSLY SUBMERGED IN FRESH WATER.
  
 8) INDICATE THE CONNECTION OF THE FLOOR
 JOISTS TO THE SLEEPERS. WILL THE 30LB
 FELT BE INSTALLED AT THE TOP OR BOTTON
 OF THE SLEEPERS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status N Date 2006-12-05 Cont ID  
Sent By lmartine Date 2006-12-05 Time 16:43 Rev Time 0.00
Received By lmartine Date 2006-12-05 Time 16:42 Sent To  
Notes
2006-12-05 16:56:03 
  
 COMPLETE ELECTRICAL INFORMATION WILL BE REQUIRED
 UNDER SEPARATE ELECTRICAL PERMIT,
  
 OK TO ISSUE STRUCTURAL , 'AT RISK'.
  
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-11-22 Cont ID  
Sent By dpalmer Date 2006-11-22 Time 09:52 Rev Time 0.00
Received By dpalmer Date 2006-11-22 Time 08:27 Sent To B
Notes
2006-11-22 09:53:19*** UNSAT 3RD REVIEW **
  
 1) NOTE: PLEASE SUBMIT ELECTRICAL FOR MINIMUM CODE
 COMPLIANCE. PLEASE SEE THE MIN SIZE OF THE CONDUCTORS
 SHALL BE BASED ON THE NEW CIRCUITS BEING PROVIDED.
 PLEASE SEE 240.4,310.16, 220.18, 220.11C1, 220.16.
 DRYER CAN NOT BE 14/3, NOR CAN THE WASHER CIRCUIT.
 PLEASE SEE BUNDLING OF THESENMC (ROMEX'S) IN ONE
 METAL CONDUIT ON THE OUTSIDE OF THE BUILDING IS ALSO
 NOT PERMITTED.
 PLEASE SEE TABLES IN 310.16
  
 2) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO
 SMOKE ALARM DEVICES REQUIRED PER FBC R313. PLEASE SHOW
 DEVICES IN EXISTING DWELLING EITHER MEETING THE CURRENT
 REQUIREMENTS OF NFPA-72 11.5.1.1 OR NEW TO BE
 INSTALLED.
 (ALL ARE REQUIRED TO BE WIRED INLINE).
  
 3) NOTE: PLEASE SEE NEW ROOM RECEPTACLE SPACING SHALL
 MEET 210.52.
  
 4) NOTE: PLEASE SEE MISSING EGRESS LIGHTING CONTROL
 FROM ROOM TO OUTSIDE AS REQUIRED PER 210.70 AND LS 101
 7.8
  
 5) NOTE: PLEASE CLARIFY IF THIS IS GOING TO BE A NEW
 LOCATION FOR LAUNDRY ROOM OR ARE THE EXISTING
 FACILITIES BEING RELOCATED?
 PLEASE SHOW SIZE OF PANEL, THE SIZE?S OF THE BREAKERS
 FEEDING THE NEW CIRCUITS.
 240.4,310.16, 408.4.
  
 6) NOTE: PLEASE BE SURE ALL SUBMITTED DRAWING DONE
 CONTAIN A PRINTED NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR PLANS AND DESIGN.
  
 ** ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.
 *IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF THE
 NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE DO
 NOT HESITATEIN CONTACTING THIS REVIEWER.
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-11-02 Cont ID  
Sent By dpalmer Date 2006-11-02 Time 12:42 Rev Time 0.00
Received By dpalmer Date 2006-11-02 Time 12:35 Sent To P
Notes
2006-11-02 12:57:47***UNSAT ***
  
 1) NOTE: PLEASE SUBMIT THE MINIMUM ELECTRICAL AS
 REQUIRED PER THE PREVIOUS REVIEW. PLEASE KNOW THERE ARE
 ELECTRICLA ITEMS WHICH NEED TO BE SHOWN AT THIS TIME
 WHICH ARE REQUIRED ALSO IN IN THE BUILDING CODE. R313,
 CHAPTER 13 ETC.
 FBC ADMIN SECT106.3.5.4, 106.1.2
 PLEASE SUBMIT .
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2006-11-02 12:37:00IN ELEC FROM ZONING ON 11/2

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-27 Cont ID  
Sent By dpalmer Date 2006-07-27 Time 21:02 Rev Time 0.00
Received By dpalmer Date 2006-07-27 Time 21:00 Sent To M
Notes
2006-07-27 00:00:00***** UNSAT ******
  
 1) NOTE: PLEASE SUBMIT ELECTRICAL PLANS
 SHOWING ALL NEW FOR LAUNDRY, HABITABLE
 ROOMS ETC.
 PLEASE SEE 2002 NEC, NFPA-72 FOR
 POSSIBLE SD'S ETC.
 PLEASE PROVIDE PANEL SCHEDULE SHOWING
 NEW/EXISTING LOADS.
 220.3,220.31, 240.4,310.16, ETC
 FBC 106.1.2
  
 2) NOTE: PLEASE SEE BUILDING REVIEW
 COMMENTS AS VALUE FOR SCOPE PF WORK
 APPLIED FOR IS LOW.
 PLEASE SEE FBC 108.3
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-11-01 Cont ID  
Sent By adarroug Date 2006-11-01 Time 18:05 Rev Time 0.00
Received By adarroug Date 2006-11-01 Time 18:05 Sent To E
Notes
2006-11-01 18:06:12TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-24 Cont ID  
Sent By adarroug Date 2006-10-24 Time 09:51 Rev Time 0.00
Received By adarroug Date 2006-10-24 Time 09:51 Sent To Z
Notes
2006-10-24 09:52:05TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-27 Cont ID  
Sent By adarroug Date 2006-07-27 Time 17:34 Rev Time 0.00
Received By adarroug Date 2006-07-27 Time 17:34 Sent To E
Notes
2006-07-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-08-16 Time   Rev Time 0.00
Received By adarroug Date 2006-07-21 Time 14:57 Sent To PC
Notes
2006-07-21 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-07-28 Cont ID  
Sent By tgordon Date 2006-07-28 Time 08:24 Rev Time 0.20
Received By tgordon Date 2006-07-28 Time 08:24 Sent To P
Notes
2006-07-28 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status N Date 2006-11-06 Cont ID  
Sent By mperson Date 2006-11-06 Time 09:43 Rev Time 0.20
Received By mperson Date 2006-11-06 Time 09:43 Sent To B
Notes
2006-11-06 09:52:03NOTE: NO PLUMBING PLANS SUBMITTED AND NO PLUMBING
 PERMIT NUMBER APPLIED FOR AT THIS TIME. PLUMBING
 CONTRACTOR AND PLANS AT A LATER DATE.

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-31 Cont ID  
Sent By mperson Date 2006-07-31 Time 08:07 Rev Time 0.33
Received By mperson Date 2006-07-31 Time 08:07 Sent To B
Notes
2006-07-31 00:00:00******DENIED******
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 A PLUMBING PERMIT IS REQUIRED FOR THIS
 PROJECT:
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW OF THE PROPOSED
 LAUNDRY ROOM:
  
 1. PER FBC-2004, CHAPTER 1, SECTION
 106.1.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE
 BUILDING OFFICIAL.
 2. PER FBC-2004, CHAPTER 1, SECTION
 106.3.5.4 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-10-30 Cont ID  
Sent By mmclean Date 2006-10-30 Time 18:41 Rev Time 0.00
Received By mmclean Date 2006-10-30 Time 18:41 Sent To I
Notes
2006-10-30 18:41:38PROVISO: THE CARPORT IS EXISTING.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-07-23 Cont ID  
Sent By mmclean Date 2006-07-23 Time 16:02 Rev Time 0.00
Received By mmclean Date 2006-07-23 Time 16:02 Sent To I
Notes
2006-07-23 00:00:00DENIED,
 1. MUST SHOW THE THE PROPOSED WORK ON
 TWO COPY OF CURRENT SURVEY WITH
 SETBACKS.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720