| Plan Review Stops For Permit 06071107 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-26 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-09-26 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | DENIED | | | | | | SUBMIT TWO ORIGONAL SIGNED AND SEALED | | | COPIES FROM HILLMAN ENGINEERING.PHOTO | | | COPIES SUBMITTED. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-08 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | DENIED | | | | | | SUBMIT TWO ORIGONAL SIGNED AND SEALED | | | COPIES FROM HILLMAN ENGINEERING.PHOTO | | | COPIES SUBMITTED. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-17 |
Time |
09:10 |
Sent To |
M |
|
| Notes |
| 2006-09-17 00:00:00 | *** UNSAT *** | | | | | | ** PLEASE SEE SOME NOTE FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES DUE TO REVISED | | | PLANS. | | | | | | | | | 1) NOTE: PLEASE CORRELATE SITE/SURVEYS. | | | PLEASE SEE THE PREVIOUS SURVEY/SITE PLAN | | | INDICATED THE ELECTRICAL SERVICE AT ONE | | | LOCATION AND THE NEW PLAN SHOWS THE | | | SERVICE COMPLETELY ON THE OTHER SIDE OF | | | THE HOUSE?? | | | PLEASE INDICATE HOW AND WHICH ROUTE IS | | | BEING TAKEN TO FEED SERVICE FROM GEN ON | | | THE SITE PLANS,WHICH IS NOW ON THE | | | OTHER SIDE OF THE DWELLING. | | | 106.1.2 FBC | | | | | | 2) NOTE: PLEASE SEE SITE PLANS MENTIONS | | | AN ATS AND INTEGRAL SUB PANEL, YET THE | | | MANUFACTURE'S SPECS CUTSHEETS AND | | | RISER DO NOT CORRELATE WITH THIS?? | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE PROVIDE A DISCONNECTING | | | MEANS FOR THE FEEDERS COMING FROM THE | | | GENERATOR GROUPED IN CLOSE PROXIMITY | | | WITH THE EXISTING/NEW MAIN BEING | | | PROPOSED. PLEASE KNOW ON OTHER PROJECTS | | | BY THE SAME CONTRACTOR, THE ATS BEING | | | USED IS THE RTSE, WHICH CONTAINS TWO | | | MEANS OF DISCONNECT, HOWEVER THIS IS NOT | | | WHAT HAS TO BE USED OR INSTALLED. | | | 225.31-225.39 | | | | | | 4) NOTE: PLEASE CLARIFY THE LOAD ON THE | | | HEAT STILL BEING SHOWN AT 3.8KVA.?? | | | THE HEAT LOAD ON A DWELLING THIS SIZE IS | | | NOT TYPICALLY 3.8KW. THIS IS ONLY NOTED, | | | AS VERIFICATION IN FIELD WILL TAKE | | | PLACE, AND PLANS MAY NEED TO BE REVISED. | | | THIS IS ONLY NOTED TO VERIFY AS THE LOAD | | | INDICATED SEEMS VERY LOW. | | | | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-28 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-28 |
Time |
20:22 |
Sent To |
M |
|
| Notes |
| 2006-07-28 00:00:00 | ********* UNSAT ********* | | | | | | 1)NOTE: PLEASE KNOW, BEFORE PICKING UP | | | THE PERMIT FOR THE GENERATOR, THE | | | NOTICE OF COMMENCEMENT WILL BE REQUIRED | | | TO BE RE-RECORDED AS THE NOC SUBMITTED | | | HAS BECOME "VOID". PLEASE SEE FS | | | 713.13(2), IF WORK HAS NOT COMMENCES | | | WITH IN 90DAYS OF RECORDING THE NOC , | | | THE NOC SHALL BECOME VOID. | | | | | | 2) NOTE: PLEASE VERIFY THE GENBEING | | | USED,A S THE SITE PLANS CALL FOR UNIT TO | | | BE 73DB'S AT 23 FT YET THE SPECS | | | SUBMITTED INDICATE MUCH LOWER RATINGS. | | | PLEASE CORRELATE. IS UNIT DIFFERENT THAN | | | THE ONE SUBMITTED ON SPECS?? | | | | | | 3) NOTE: PLEASE INDICATE ON RISER THE | | | ATS BEING SE RATED. | | | PLEASE ALSO HIGHLIGHT THE CORRECT ATS ON | | | SUBMITTIAL. | | | 110.3,90.7 | | | | | | 4) NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR AFTER THE FIRST | | | MEANS OF DISCONNECT. | | | 250.110,250.24B,250.122 ETC | | | | | | 5) NOTE: PLEASE PROVIDE THE DETAIL ON | | | THE LOAD SHEDDING INTERLOCK RELAY BEING | | | PROPOSED FOR "SHEDDING" OF THE HEAT | | | STRIP. | | | 702.5,220. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 6) NOTE: PLEASE PROVIDE ALL DIMENSIONS | | | ON GENERATOR FROM SURROUNDING | | | WALLS/HOUSE ETC. | | | PLEASE KNOW, INFORMATION OPTAINED BY | | | THIS OFFICE FROM MANUFACTURE FOR THIS | | | TYPE OF UNIT REQUIRES A MIN OF 5' FROM | | | ANY SURROUNDING WALLS ETC FOR | | | VENTILATION ETC. | | | IF DISTANCE OBTAINED IS LESS , PLEASE | | | PROVIDE WRITTENT DOCUMENTATION FROM THE | | | MANUFACTURE FOR THIS. | | | "IF UNIT IS ALREADY 5', PLEASE SHOW. | | | 110.3,90.7 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-18 |
Time |
10:34 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-18 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2006-09-18 00:00:00 | ******DENIED 2ND TIME****** | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS STILL | | | REQUIRED FOR GAS PLAN REVIEW ON THE | | | ISOMETRIC DRAWING. (NOTE: THE FOLLOWING | | | PRIVIOUS COMMENTS WERE NOT ADDRESSED) | | | | | | 1. COMMENT #1 (UNSAT) | | | NOTE: ABOVE GROUND PIPING MATERIAL IS | | | STILL NOT INDICATED ON THE ISOMETRIC GAS | | | RISER DIAGRAM. | | | | | | 2. COMMENT #2 (OK) | | | | | | 3. COMMENT #3 (UNSAT) | | | BTU LOAD OF EACH APPLIANCE AND THE TOTAL | | | BTU LOAD ON THE SYSTEM. REFER TO THE | | | FBC-2004 FUEL GAS CODE SECS. 401.8 THRU | | | 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). (NOTE: THIS INCLUDES THE | | | EXISTING GAS SYSTEM, PLEASE SEE ATTACHED | | | PERMIT INFORMATION SHEET FOR REFERENCE | | | OF EXISTING SYSTEM HAVING GAS FOR | | | RESUBMITTAL. THE TOTAL BTU LOAD OF | | | SYSTEM NEEDS TO BE INDICATED ON THE | | | DRAWING.) | | | | | | 4. COMMENT #4 (UNSAT) | | | SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (NOTE: THIS | | | INCLUDES THE EXISTING GAS SYSTEM AS WELL | | | AS THE PROPOSED GAS TO THE GENERATOR. | | | THE GAS SYSTEM IS SIZED BY THE LONGEST | | | LENGTH METHOD, THE ONLY MEASUREMENT | | | INDICATED ON THE GAS ISOMETRIC IS 15' | | | +/- THIS IS UNACCEPTABLE. THE GAS METER | | | INDICATED ON THE SITE PLANIS INDICATED | | | ON THE OTHER SIDE OF THE HOUSE AND IS | | | DEFINITELY LONGER THAN 15'. PLEASE | | | INDICATE THE LONGET LENGTH FROM METER TO | | | THE MOST REMOTE OUTLET IN THE BUILDING | | | OR SYSTEM. PLEASE CORRECT THIS FOR THE | | | RESUBMITTAL. | | | | | | 5. COMMENT #5 (OK) | | | | | | 6. COMMENT #6 (OK) | | | | | | 7. COMMENT #7 (OK) | | | | | | 8. COMMENT #8 (OK) | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-01 |
Time |
15:04 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-08-01 |
Time |
15:04 |
Sent To |
B |
|
| Notes |
| 2006-08-01 00:00:00 | REFERENCE: GAS PERMIT #06071115 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-08 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-08 |
Time |
16:11 |
Sent To |
E |
|
| Notes |
| 2006-09-08 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-28 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-28 |
Time |
09:15 |
Sent To |
E |
|
| Notes |
| 2006-07-28 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-21 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-18 |
Time |
09:12 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-18 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
| 2006-09-18 00:00:00 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-31 |
Time |
08:44 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-07-31 |
Time |
08:44 |
Sent To |
P |
|
| Notes |
| 2006-07-31 00:00:00 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #6, ALSO | | | SHOW IF BUILDING IS MADE OF COMBUSTIBLE | | | MATERIAL OR NOT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-23 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-23 |
Time |
14:23 |
Sent To |
I |
|
| Notes |
|
|