Plan Review Details - Permit 06071012
Plan Review Stops For Permit 06071012
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-10-27 Cont ID  
Sent By alange Date 2006-10-27 Time 14:25 Rev Time 0.00
Received By alange Date 2006-10-27 Time 14:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-22 Cont ID  
Sent By dpalmer Date 2006-10-06 Time   Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2006-10-22 11:15:19SEE ELECTRICAL REVIEW NOTES

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-09-08 Cont ID  
Sent By alange Date 2006-09-08 Time 11:08 Rev Time 0.00
Received By alange Date 2006-09-08 Time 11:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-26 Cont ID  
Sent By alange Date 2006-07-26 Time 13:55 Rev Time 0.00
Received By alange Date 2006-07-26 Time 13:55 Sent To  
Notes
2006-07-26 00:00:00DENIED
  
 1.COMPLETE A SHUTTER INSTALLATION
 SCHEDULE.SEE ATTACHED SAMPLE.
  
 2.CAULK REQUIRED UNDER FLOOR TILE FBC
 1207.2
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-03 Cont ID  
Sent By dpalmer Date 2006-11-03 Time 13:41 Rev Time 0.00
Received By dpalmer Date 2006-11-03 Time 12:49 Sent To PC
Notes
2006-11-03 13:44:37**** REDLINED PLANS.
  
  
 ELECTRICAL ITEMS LTS/RECEPTS SOWN ON PLANS WITHOUT
 CIRCUITS ARE NOT INCLUDED IN SCOPE OF WORK AND ARE
 EXISTING PER CONTRACTOR.
 ONLY THE ELECTRICAL DEVICESWHICH CONTAIN CIRCUITS #'S
 ARE NEW.
  
 ** IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-10-22 Cont ID  
Sent By dpalmer Date 2006-10-22 Time 12:22 Rev Time 0.00
Received By dpalmer Date 2006-10-22 Time 11:16 Sent To  
Notes
2006-10-22 12:22:24****** PROVISO/ REVISION NEEDED *****
  
 *** PLEASE SEE THE SAME NOTES FROM THE PREVIOUS THREE
 REVIEWS.
 PLEASE KNOW A "HOLD" WILL BE PLACED ON THE ELECTRICAL
 PERMIT NUMBER 06071025 WHICH WILL NOT PERMIT ANY
 INSPECTIONS TO BE SCHEDULED.
 PLEASE ALSO KNOW, REVISED PLANS SHALL BE SUBMITTED
 ADDRESSING COMMENTS BELOW WITHIN 10DAYS FROM ISSUANCE
 OF BUILDING PERMIT ORSAID BUILDING PERMIT WILL BE
 REVOKED.
 THIS IS THE FIRST SET OF PLANS ARE BEING SUBMITTED
 UNDER A NEW LICENSED ARCHITECT AS PREVIOUSLY
 REQUESTED.
  
 1) NOTE:
 A) PLEASE SHOW AND INDICATE ALL CIRCUITING ON PLANS AND
 CORRELATE WITH A PANEL SCHEDULE TO BE SUBMITTED.408.4.
 310.16, 240.4 FBC ADMIN SECT 106..3.5.1.2
 B) PLEASE SEE THE LOAD CALCULATIONS SUBMITTED DO NOT
 INDICATE ALL THE MINIMUM REQUIRED CIRCUITS AS
 REQUIRED.
 C) PLEASE SEE MISSING DEDICATED BATH(S) PER 210.52D,
 210.11C3 (20A, #12).
 D) PLEASE SEE MISSING GFI RECEPT ALONG WHAT APPEARS TO
 BE KITCHEN COUNTER SPACE 210.8A6, 210.52C1
 E) PLEASE PLACE UNIT # ON SAID PLANS AS REQUIRED ON
 TITLE BLOCKS. THIS WAS HANDWRITTEN ON ELECTRICAL PLANS
 SUBMITTED.
 F) PLEASE SEE NEW SA/SD'S WILL BE REQUIRED TO BE ARC
 FAULT POTECTED FOR 120V SYSTEM. 210.12B
 F) PLEASE SEE NO OTHER PLANS WERE SUBMITTED.LAYOUT
 AND LOCATIONS OF CERTAIN APPLIANCES HAVE BEEN
 RELOCATED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. ONCE
 AGAIN IF THERE ARE ANY QUESTIONS, PLEASE DO NOT
 HESITATE IN CONTACTING THIS OFFICE. PLEASE KNOW , TO
 DATE NO CONTACT TO THIS OFFICEHAS BEEN MADE FOR ANY
 CODE COMPLIANCE QUESTIONS OR COMMENTS.
  
 DEWEY PALMER
 ELECTRICAL PLAN EXAMINER
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-09-30 Cont ID  
Sent By dpalmer Date 2006-09-30 Time 13:13 Rev Time 0.00
Received By dpalmer Date 2006-09-30 Time 12:58 Sent To  
Notes
2006-09-30 00:00:00***** UNSAT 3RD REVIEW ******
  
 1) NOTE: PLEASE SEE AT STATED IN TWO
 PREVIOUS REVIEWS AND THIS WAS CONFIRMED
 WITH THE STATE'S LEGAL COUNSEL TO TEH
 BOARD OF ARCHITECT'S. THE PLANS REQUIRED
 TO BE SUBMITTED MUST EB DONE BY AN
 ARCHITECT AT A MINIMUM. A GC MAY NOT
 SIGN AND SEAL PLANS FOR SCOPE OF WORK AS
 SHOWN.
 PLEASE SEE FS 481.203, 481.223, 481.229.
 AS STATED PREVIOUSLY, THIS IS REQUIRED
 WHETHER OR NOT OTHER PLANS WERE STAMPED
 OR PASSED BY OTHER REVIEWER(S).
 PLEASE SEE STAMPED PLANS FROM PREVIOUS
 REVIEW HAVE BEEN "VOIDED".
  
 2) NOTE: PLEASE KNOW, THERE ARE MANY
 CODE COMPLIANT ITEMS WHICH STILL NEED TO
 BE ADDRESSED ALONG WITH NEW COMMENTS
 BASED ON THE PLANS SUBMITTED.
 PLEASE SEE 422.17
 PLEASE SEE 110.26,
 PLEASE SEE 422.31
 PLEASE SEE 424.3B, CORRELATE PLANS
 LOADS, OCP ETC FOR THE AHU.
 PLEASE SEE 210.52D, 210.11C3,
 PLEASE SUBMIT SPECS FOR NEW STEAM GEN
 UNIT. 110.3, 90.7 ETC
 PLEASE SEE FBC 2004 R313, SHOW NEW OR
 EXISTIGNSD'S MEEETING THE CURRENT CODE.
 NFPA-72 11.5.1.1, 11.8.3.
  
  
 PLEASE SEE NEC 2002, NFPA-72 2002.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-10 Cont ID  
Sent By dpalmer Date 2006-09-10 Time 13:13 Rev Time 0.00
Received By dpalmer Date 2006-09-08 Time 12:51 Sent To  
Notes
2006-09-10 00:00:00 
 1) NOTE: PLEASE SEE 210.8A6 AS ALL
 RECEPTS SERVING KITCHEN COUNTER SPACE
 ARE REQUIRED TO BE GFI/GFI PROTECTED.
  
 2) NOTE: PLEASE SEE SCOPE OF WORK ON
 PLANS IS NOT PERMITTED IN PEN , PENCIL.
 PLEASE SEE AS PREVIOUSLY NOTED ON
 PREVIOUS REVIEW, PLANS SUBMITTED MUST BE
 DONE BY AN ARCHITECT AS REQUIRED UDNER
 FS 481.229.
 PLEASE KNOW THIS IS REQUIRED OF ALL
 PLANS EVEN IF ALREADY STAMPED BY OTHER
 TRADES.
 LEVEL OF ALTERATION SHALL BE STATED PER
 FBCEXSITING BUIDLING CODE.
 106.1.2, 106.1, 106.1.3 FBC ADMIN SECT.
  
 3) NOTE: PLEASE SEE NOTHIG SUBMITTED FOR
 NEW WATER HEATER AND NEW A/C. SAME SIZE
 UNITS, NEW OR EXISTING DISCONNECT,
 LOCATIONS? ETC
 440.11,422.31,
 PLEASE SEE THERE ARE NO LOADS INDICATED
 ON PANEL, PLEASE SEE IT IS UNCLEAR IF
 THERE IS AN INCREASE IN THE NEW UNITS.
 PLEASE ALSO COMPELTE THE LAOD
 CACULATION.
 220.31
  
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-27 Cont ID  
Sent By dpalmer Date 2006-07-27 Time 16:44 Rev Time 0.00
Received By dpalmer Date 2006-07-27 Time 16:31 Sent To  
Notes
2006-07-27 00:00:00********** UNSAT ************
  
 1) NOTE: PLEASE PROVIDE AN ELECTRICAL
 LAYOUT FOR COMPLETE SCOPE OF ELECTRICAL
 WORK.
 PLEASE INDICATE ALL NEW OR EXISTING GFI
 RECEPT LOCATIONS ALONG KITCHEN COUNTER
 SPACE. 210.52C1-5, 210.8A6
 BATH(S), 210.11C3,220.16.
 PLEASE LIST AL MIN CIRCUITS REQUIRED PER
 NEC 2002
 PLEASE INCLUDE PANEL SCHEDULE WITH
 CIRCUITING ETC.
 106.1.2
  
 2) NOTE: PLEASE SEE 2004 R313 AND SHOW
 ALL LOCATIONS OF NEW OR EXISTING SD'S
 EITHER MEETING THE CURRENT NFPA-72
 11.5.1.1 OR NEW TO BE INSTALLED.
  
 3) NOTE: PLEASE BE SURE TO SEE 210.12B
 FOR ARC FAULT PROTECTION.
  
 4) NOTE: PLEASE SEE THAT PLANS SHALL BE
 DONE BY AN ARCHITEC AT A MIN. FS 481.229
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2006-10-26 Cont ID  
Sent By mawillia Date 2006-10-26 Time 15:21 Rev Time 0.00
Received By mawillia Date 2006-10-26 Time 15:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2006-10-06 Cont ID  
Sent By jleech Date 2006-10-06 Time 14:37 Rev Time 0.00
Received By jleech Date   Time   Sent To  
Notes
2006-10-06 00:00:00SEE ELECTRICAL PLAN REVIEW NOTES

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-09-13 Cont ID  
Sent By mwennerg Date 2006-09-13 Time 09:28 Rev Time 0.00
Received By mwennerg Date 2006-09-13 Time 09:28 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By mawillia Date 2006-08-07 Time 09:53 Rev Time 0.00
Received By mawillia Date 2006-08-07 Time 09:52 Sent To  
Notes
2006-08-07 00:00:00***UNSAT***
  
 1.) INDICATE ON PLANS THE LOCATION OF
 FIRE PROTECTION SYSTEMS (I.E. SPRINKLER,
 SMOKE DETECTORS, ETC.) AND WHETHER THE
 LISTED ALTERATIONS WILL AFFECT THEIR
 OPERATION.
  
 2.)NFPA 241 TO BE ADHERED TO DURING
 CONSTRUCTION, ALTERATION, AND DEMOLITION
 OPERATIONS.
  
  
  
  
  
 LT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 15:19 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 15:16 Sent To E
Notes
2006-11-02 15:16:28TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-14 Cont ID  
Sent By adarroug Date 2006-10-14 Time 17:51 Rev Time 0.00
Received By adarroug Date 2006-10-14 Time 17:51 Sent To  
Notes
2006-10-22 11:16:37TO BOB BOARD #9
2006-10-14 17:52:10WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-28 Cont ID  
Sent By adarroug Date 2006-09-28 Time 15:06 Rev Time 0.00
Received By adarroug Date 2006-09-28 Time 15:06 Sent To  
Notes
2006-09-29 00:00:00TO "BOB"#16
2006-09-28 00:00:00WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-26 Cont ID  
Sent By adarroug Date 2006-08-26 Time 16:27 Rev Time 0.00
Received By adarroug Date 2006-08-26 Time 16:26 Sent To  
Notes
2006-09-08 00:00:00TO "BOB"#1
2006-08-26 00:00:00WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-07 Cont ID  
Sent By mawillia Date 2006-08-07 Time 09:52 Rev Time 0.00
Received By mawillia Date 2006-07-19 Time 16:32 Sent To  
Notes
2006-07-25 00:00:00TO "BOB"#18
2006-07-19 00:00:00WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2006-10-03 Cont ID  
Sent By tgordon Date 2006-10-03 Time 15:33 Rev Time 0.20
Received By tgordon Date 2006-10-03 Time 15:33 Sent To  
Notes
2006-10-03 00:00:00MECHANICAL PERMIT #06071027 HAS BEED
 VOIDED BY MECH. CONTRACTOR.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-09-11 Cont ID  
Sent By tgordon Date 2006-09-11 Time 11:09 Rev Time 0.15
Received By tgordon Date 2006-09-11 Time 11:09 Sent To  
Notes
2006-09-11 00:00:00*** DENIED ***
 1) A LETTER FROM ACTION MECH. WILL BE
 NEEDED TO VOID MECHANICAL PERMIT #
 06071027.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-07-28 Cont ID  
Sent By tgordon Date 2006-07-28 Time 08:04 Rev Time 0.15
Received By tgordon Date 2006-07-28 Time 08:04 Sent To  
Notes
2006-07-28 00:00:00*** DENIED ***
 1) NO MECHANICAL PLANS WERE SUBMITTED
 FOR REVIEW. PLEASE SUBMIT MECHANICAL
 PLANS FOR REVIEW, IF ONLY CHANGING A/C
 UNIT AND NOT DUCT WORK THEN STATE THAT
 ON PLANS, OR YOU MAY WISH TO VOID YOUR
 MECHANICAL PERMIT NUMBER 06071027 SO
 YOUR BUILDING PLANS MAY BY-PASS A
 MECHANICAL REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-10-27 Cont ID  
Sent By jleech Date 2006-10-27 Time 13:37 Rev Time 0.00
Received By jleech Date 2006-10-27 Time 13:36 Sent To  
Notes
2006-10-27 13:37:57FIXTURE CHANGE OUT ONLY NO PIPING.

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-10-06 Cont ID  
Sent By jleech Date 2006-10-06 Time 14:30 Rev Time 0.00
Received By jleech Date 2006-10-06 Time 14:30 Sent To  
Notes
2006-10-06 00:00:00DENIED;
 SEE ELECTRICAL PLAN REVIEW COMMENTS.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-09-09 Cont ID  
Sent By jleech Date 2006-09-09 Time 06:18 Rev Time 0.00
Received By jleech Date 2006-09-09 Time 06:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-26 Cont ID  
Sent By jleech Date 2006-07-26 Time 08:55 Rev Time 0.00
Received By jleech Date 2006-07-26 Time 08:55 Sent To  
Notes
2006-07-26 00:00:00DENIED;
 PLEASE LIST SCOPE OF WORK TO BE DONE BY
 PLUMBER ON PLANS; ( ALL FIXTURES TO BE
 CHANGED, NO PIPES TO BE MOVED, CHANGE
 WATER HEATER WITH SAME SIZE ETC)