| Plan Review Stops For Permit 06070748 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-26 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-09-26 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-01 |
Time |
14:15 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-09-01 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | DENIED | | | | | | SUBMIT TWO SETS OF ORIGONAL SIGNED AND | | | SEALED PLANS FROM HILLMAN ENGINEERING. | | | PAGES SUBMITTED ARE PHOTO COPIES. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-07 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-07 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | DENIED | | | | | | SUBMIT TWO SETS OF ORIGONAL SIGNED AND | | | SEALED PLANS FROM HILLMAN ENGINEERING. | | | PAGES SUBMITTED ARE PHOTO COPIES. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-19 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-19 |
Time |
07:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-27 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-27 |
Time |
12:32 |
Sent To |
B |
|
| Notes |
| 2006-08-27 00:00:00 | *** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE GEN REQUIRES 3 FT | | | FROM HOUSE AND REQUIRES A MIN OF 3' FROM | | | ADJOING PROPERTY AS THE NEIGHBORING | | | PROPERTY OWNER MAY INSTALL A WALL WHICH | | | THEN WOULD NOT HAVE THE 3' MIN CLEARENCE | | | REQUIRED. PLEASE SEE SIDE WOULD HAVE TO | | | BE 8FT OR MORE. | | | PLEASE SEE ZONING ONLY PERMITS GEN 4FT | | | INTO THE REQUIRED SET BACK AND IF GEN IS | | | 3FT OFF WALL AND GEN IS 2FT WIDE, THEN | | | THE GEN IS TOO FAR INTO THE ZOING SET | | | BACK ALLOWED. | | | PLEASE SEE IT SEEMSA REVISED LOCATION | | | MAY BE NEEDED. | | | 110.3,90.7 | | | | | | 2) NOTE: PLEASE SEE GROUPING OF | | | DISCONNECTING MEANS CAN NOT YET BE | | | VERIFIED AS THE NEW DISCONNECT BEING | | | NOTED IS NOT SHOWN ON PLANS GROUPED. | | | PLEASE PROVIDE A LAYOUT OF THE MAIN AND | | | THE NEW DISCONNECT. AS SHOWN ON RISER, | | | ALL EQUIPMENT IS OUTSIDE, YET THE SPECS | | | FOR THE ATSPANEL SUBMITTED IS A NEMA 1 | | | LOCATION ONLY. | | | PLEASE INDICATE THE OCP FROM THE | | | EXISTING PANEL TO NEW SUB PANEL AND | | | PELASE INDICATE THE SIZE OF THE NEW | | | DISCONNECT/CONDUCTORS. | | | 240.4,310.16,225.39 225.34, 230.72 ETC | | | | | | 3) NOTE: PLEASE BE SURE ALL | | | PLANS/DESIGNS SUBMITTED CONTAINS THE | | | PRINTED NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR PLANS. | | | FBC 106.1.2 | | | | | | ** PLEASE SEE SURE TO COPY ALL PLANS AS | | | HANDWRITTEN AND WHITE OUT ON PLANS BEING | | | SUBMITTED IS NOT PERMITTED. | | | 106.1.2,106.1.3,106.1 | | | FBC | | | | | | ** IMPORTANT** | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-27 |
Time |
19:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-27 |
Time |
19:41 |
Sent To |
M |
|
| Notes |
| 2006-07-27 00:00:00 | ****** UNSAT ****** | | | | | | 1) NOTE: PLEASE SUBMIT INFORMATION ON | | | THE MINIMUM CLEARENCES FOR GENERATOR. | | | LTRS OBTAINED BY THIS OFFICE FROM | | | MANUFACTURE REQUIRES A MIN OF 3' FROM | | | ALL SURROUNDING WALLS/HOUSE ETC. | | | 110..3/90.7 | | | PLEASE KNOW, DUE TO THE MIN REQUIRED | | | CLEARENCE, AND ZOING SETBACK, GENERATOR | | | LOCATION MAY BE REVISED. | | | | | | 2) NOTE: PLEASE SEE MISSING DISCONNECT | | | REQUIRED FOR FEEDERS FROM GENERATOR AT | | | HOUSE. PLEASE SEE 225.31-225.39. | | | THE BRKR ON THE GENERATOR IS NOT | | | ACCEPTABLE FOR THE MEANS OF DISC. | | | | | | 3) NOTE: PLEASE SEE THAT ALL PLANS ARE | | | REQUIRED TO CONTAIN THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR | | | PLANS/DESIGNS. | | | FBC 106.1.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-01 |
Time |
11:08 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-08-01 |
Time |
11:08 |
Sent To |
B |
|
| Notes |
| 2006-08-01 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
10:00 |
Sent To |
E |
|
| Notes |
| 2006-09-18 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
14:10 |
Sent To |
Z |
|
| Notes |
| 2006-09-09 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-22 |
Time |
18:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-22 |
Time |
18:43 |
Sent To |
E |
|
| Notes |
| 2006-08-22 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
16:44 |
Sent To |
E |
|
| Notes |
| 2006-07-27 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-07 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-14 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2006-07-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-28 |
Time |
15:36 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-07-28 |
Time |
15:36 |
Sent To |
P |
|
| Notes |
| 2006-07-28 00:00:00 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | PROVIDE MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AT THE JOBSITE FOR THE | | | FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-14 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-14 |
Time |
11:39 |
Sent To |
I |
|
| Notes |
| 2006-09-14 00:00:00 | RESUB- CHANGE OF LOCATION OF THE | | | PROPOSED GENERATOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-23 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-23 |
Time |
13:39 |
Sent To |
I |
|
| Notes |
| 2006-07-23 00:00:00 | NOTE: | | | THE PROPOSED GENERATOR SHALL NOT BE | | | CLOSER THAN 1FT FROMSIDE PROPERTY | | | LINE. |
|
|