Plan Review Details - Permit 06070748
Plan Review Stops For Permit 06070748
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-09-26 Cont ID  
Sent By alange Date 2006-09-26 Time 14:54 Rev Time 0.00
Received By alange Date 2006-09-26 Time 14:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-01 Cont ID  
Sent By alange Date 2006-09-01 Time 14:15 Rev Time 0.50
Received By alange Date 2006-09-01 Time 14:15 Sent To  
Notes
2006-09-01 00:00:00DENIED
  
 SUBMIT TWO SETS OF ORIGONAL SIGNED AND
 SEALED PLANS FROM HILLMAN ENGINEERING.
 PAGES SUBMITTED ARE PHOTO COPIES.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By alange Date 2006-08-07 Time 14:43 Rev Time 0.00
Received By alange Date 2006-08-07 Time 14:43 Sent To  
Notes
2006-08-07 00:00:00DENIED
  
 SUBMIT TWO SETS OF ORIGONAL SIGNED AND
 SEALED PLANS FROM HILLMAN ENGINEERING.
 PAGES SUBMITTED ARE PHOTO COPIES.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-19 Cont ID  
Sent By dpalmer Date 2006-09-19 Time 07:25 Rev Time 0.00
Received By dpalmer Date 2006-09-19 Time 07:11 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-08-27 Cont ID  
Sent By dpalmer Date 2006-08-27 Time 12:42 Rev Time 0.00
Received By dpalmer Date 2006-08-27 Time 12:32 Sent To B
Notes
2006-08-27 00:00:00*** UNSAT **
  
 1) NOTE: PLEASE SEE GEN REQUIRES 3 FT
 FROM HOUSE AND REQUIRES A MIN OF 3' FROM
 ADJOING PROPERTY AS THE NEIGHBORING
 PROPERTY OWNER MAY INSTALL A WALL WHICH
 THEN WOULD NOT HAVE THE 3' MIN CLEARENCE
 REQUIRED. PLEASE SEE SIDE WOULD HAVE TO
 BE 8FT OR MORE.
 PLEASE SEE ZONING ONLY PERMITS GEN 4FT
 INTO THE REQUIRED SET BACK AND IF GEN IS
 3FT OFF WALL AND GEN IS 2FT WIDE, THEN
 THE GEN IS TOO FAR INTO THE ZOING SET
 BACK ALLOWED.
 PLEASE SEE IT SEEMSA REVISED LOCATION
 MAY BE NEEDED.
 110.3,90.7
  
 2) NOTE: PLEASE SEE GROUPING OF
 DISCONNECTING MEANS CAN NOT YET BE
 VERIFIED AS THE NEW DISCONNECT BEING
 NOTED IS NOT SHOWN ON PLANS GROUPED.
 PLEASE PROVIDE A LAYOUT OF THE MAIN AND
 THE NEW DISCONNECT. AS SHOWN ON RISER,
 ALL EQUIPMENT IS OUTSIDE, YET THE SPECS
 FOR THE ATSPANEL SUBMITTED IS A NEMA 1
 LOCATION ONLY.
 PLEASE INDICATE THE OCP FROM THE
 EXISTING PANEL TO NEW SUB PANEL AND
 PELASE INDICATE THE SIZE OF THE NEW
 DISCONNECT/CONDUCTORS.
 240.4,310.16,225.39 225.34, 230.72 ETC
  
 3) NOTE: PLEASE BE SURE ALL
 PLANS/DESIGNS SUBMITTED CONTAINS THE
 PRINTED NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR PLANS.
 FBC 106.1.2
  
 ** PLEASE SEE SURE TO COPY ALL PLANS AS
 HANDWRITTEN AND WHITE OUT ON PLANS BEING
 SUBMITTED IS NOT PERMITTED.
 106.1.2,106.1.3,106.1
 FBC
  
 ** IMPORTANT**
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-27 Cont ID  
Sent By dpalmer Date 2006-07-27 Time 19:59 Rev Time 0.00
Received By dpalmer Date 2006-07-27 Time 19:41 Sent To M
Notes
2006-07-27 00:00:00****** UNSAT ******
  
 1) NOTE: PLEASE SUBMIT INFORMATION ON
 THE MINIMUM CLEARENCES FOR GENERATOR.
 LTRS OBTAINED BY THIS OFFICE FROM
 MANUFACTURE REQUIRES A MIN OF 3' FROM
 ALL SURROUNDING WALLS/HOUSE ETC.
 110..3/90.7
 PLEASE KNOW, DUE TO THE MIN REQUIRED
 CLEARENCE, AND ZOING SETBACK, GENERATOR
 LOCATION MAY BE REVISED.
  
 2) NOTE: PLEASE SEE MISSING DISCONNECT
 REQUIRED FOR FEEDERS FROM GENERATOR AT
 HOUSE. PLEASE SEE 225.31-225.39.
 THE BRKR ON THE GENERATOR IS NOT
 ACCEPTABLE FOR THE MEANS OF DISC.
  
 3) NOTE: PLEASE SEE THAT ALL PLANS ARE
 REQUIRED TO CONTAIN THE PRINTED NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 PLANS/DESIGNS.
 FBC 106.1.2
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-08-01 Cont ID  
Sent By mperson Date 2006-08-01 Time 11:08 Rev Time 0.15
Received By mperson Date 2006-08-01 Time 11:08 Sent To B
Notes
2006-08-01 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL GEN/RES INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-09-18 Cont ID  
Sent By adarroug Date 2006-09-18 Time 10:00 Rev Time 0.00
Received By adarroug Date 2006-09-18 Time 10:00 Sent To E
Notes
2006-09-18 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 14:10 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 14:10 Sent To Z
Notes
2006-09-09 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-22 Cont ID  
Sent By adarroug Date 2006-08-22 Time 18:43 Rev Time 0.00
Received By adarroug Date 2006-08-22 Time 18:43 Sent To E
Notes
2006-08-22 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-27 Cont ID  
Sent By adarroug Date 2006-07-27 Time 16:44 Rev Time 0.00
Received By adarroug Date 2006-07-27 Time 16:44 Sent To E
Notes
2006-07-27 00:00:00TO "GEN-RES" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-07 Cont ID  
Sent By alange Date 2006-08-07 Time 14:46 Rev Time 0.00
Received By alange Date 2006-07-14 Time 18:45 Sent To  
Notes
2006-07-14 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-07-28 Cont ID  
Sent By tgordon Date 2006-07-28 Time 15:36 Rev Time 0.15
Received By tgordon Date 2006-07-28 Time 15:36 Sent To P
Notes
2006-07-28 00:00:00*** PROVISO ***
 1) PER 2004 FBC, FUEL GAS - POWERED
 EQUIPMENT - PERMANENTLY INSTALLED
 EQUIPMENT POWERED BY INTERNAL COMBUSTION
 ENGINES SHALL BE INSTALLED IN ACCORDANCE
 WITH MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AND NFPA 37.
  
 NFPA 37 INSTALLATION & USE OF STATIONARY
 COMBUSTION ENGINES & GAS TURBINES:
 4.1.4ENGINES (GENERATORS) LOCATED
 OUTDOORS SHALL BE MINIMUM OF 5 FT FROM
 OPENINGS IN WALLS & AT LEAST 5 FT FROM
 STRUCTURES HAVING COMBUSTIBLE WALLS.A
 MINIMUM CLEARANCE IS NOT REQUIRED WHEN
 (1) THE ADJACENT WALL HAS A MINIMUM FIRE
 RESISTANCE RATING OF 1 HOUR OR (2) THE
 WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF
 NON-COMBUSTIBLE MATERIALS, AND IT HAS
 BEEN DEMONSTRATED THAT A FIRE WITHIN THE
 ENCLOSURE WILL NOT IGNITE COMBUSTIBLE
 MATERIALS OUTSIDE THE ENCLOSURE.
 INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS
 SHOULD NOT TERMINATE UNDER STRUCTURES OR
 WHERE THE EXHAUST MIGHT BE DRAWN INTO
 THE VENTILATION INTAKES.
  
 2004 FMC 804.3.5 #3, WHERE THE
 TERMINATION IS LOCATED BELOW AN ADJACENT
 ROOF STRUCTURE, THE TERMINATION POINT
 SHALL BE LOCATED AT LEAST 3 FT FROM THE
 ROOF STRUCTURE.
  
 PLEASE NOTE, WHILE ZONING ALLOWS
 MECHANICAL EQUIPMENT TO ENCROACH 4 FT
 INTO THE REQUIRED SETBACK, GENERATORS
 SHALL MAINTAIN THE REQUIRED ABOVE
 MENTIONED CLEARANCES TO THE ADJACENT
 PROPERTY STRUCTURES, I.E. FENCE,
 BUILDING, WINDOWS, DOORS, OR OPENINGS.
  
 PROVIDE MANUFACTURE'S INSTALLATION
 INSTRUCTIONS AT THE JOBSITE FOR THE
 FIELD INSPECTOR.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-09-14 Cont ID  
Sent By mmclean Date 2006-09-14 Time 11:39 Rev Time 0.00
Received By mmclean Date 2006-09-14 Time 11:39 Sent To I
Notes
2006-09-14 00:00:00RESUB- CHANGE OF LOCATION OF THE
 PROPOSED GENERATOR.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-07-23 Cont ID  
Sent By mmclean Date 2006-07-23 Time 13:39 Rev Time 0.00
Received By mmclean Date 2006-07-23 Time 13:39 Sent To I
Notes
2006-07-23 00:00:00NOTE:
 THE PROPOSED GENERATOR SHALL NOT BE
 CLOSER THAN 1FT FROMSIDE PROPERTY
 LINE.