| Plan Review Stops For Permit 06070671 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-24 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-24 |
Time |
16:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-25 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-25 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-16 |
Time |
20:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-16 |
Time |
20:23 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | REDLINED PLANS. | | | BOX, FEEDERS ETC ABOVE CEILING SHALL BE | | | LABLED AND IDENTIFIED FOR FEEDERS/BOX , | | | CIRCUIT AND PANEL LOCATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-18 |
Time |
18:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-18 |
Time |
18:25 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | ********** UNSAT *********** | | | | | | 1) NOTE: PLEASE SEE PLANS SHALL CONTAIN | | | A CLEAR AND VISABLE SEAL WITH ALL | | | INFORMATION AS REQUIRED ON SAID SEAL. | | | PLEASE SEE FAC 61G15-23.001,.002 AND FS | | | 471.025 | | | ** PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | SHEETS AND FOR ALL TRADES WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 2) NOTE: PLEASE SEE PLAN NOTES MENTIONS | | | THE COMPLETE REMOVAL OF PANEL "J", | | | WIRING , CONDUIT ETC AND TERMINATE | | | FEEDERS INTO A J-BOX IN CEILING AREA | | | WITH TAPS, LABELING ETC, HOWEVER PLEASE | | | SEE NEW RECEPTS SHOWN INDICATE THE | | | CIRCUITING TO THIS PANEL WHICH IS BEING | | | REMOVED?? | | | HOW IS THIS POSSIBLE OR IS THERE ANOTHER | | | PANEL "J"?? | | | PLEASE CORRELATE AND REVISE AS NEEDED. | | | | | | 3) NOTE: PLEASE SEE THAT THE FOLLOWING | | | CODES AT A MIN SHALL BE INDICATED ON | | | PLANS. | | | 2004 FBC, NFPA-70 2002 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-08-24 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-08-24 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2006-08-24 00:00:00 | **APPROVED** | | | | | | | | | | | | | | | | | | 1.)STRUCTURES UNDERGOING CONSTRUCTION, | | | ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 2.)ACCUMULATIONS OF COMBUSTIBLE WASTE | | | MATERIAL, DUST AND DEBRIS SHALL BE | | | REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH | | | SHIFT OR MORE FREQUENTLY AS NECESSARY | | | FOR SAFE OPERATIONS. | | | | | | 3.) WHERE THE BUILDING IS PROTECTED BY | | | FIRE PROTECTION SYSTEMS, SUCH SYSTEMS | | | SHALL BE MAINTAINED OPERATIONAL AT ALL | | | TIMES DURING ALTERATION. | | | | | | 4.)PROVIDE SEPARATE PERMIT AND SHOP | | | DRAWINGS/PLANS FOR SPRINKLER REMODEL. | | | | | | | | | | | | | | | | | | LT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-19 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-19 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2006-07-19 00:00:00 | ***DENIED*** | | | | | | PLEASE SEE OTHER REVIEW COMMENTS | | | REGARDING CLARITY AND VISIBILITY | | | REQUIREMENTS FOR ENGINEER'S SEAL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-10 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-10 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | TO "BOB"#11 | | 2006-08-10 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-25 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-13 |
Time |
16:02 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | TO "BOB"#18 | | 2006-07-13 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-17 |
Time |
13:49 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-08-17 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-18 |
Time |
14:14 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-07-18 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | *** DENIED *** | | | 1) ENGINEER'S SEAL IMPRESSION IS NOT | | | VISIBLE NOR LEGIBLE, PLEASE HAVE | | | ENGINEER RE-SEAL PLANS (CHECK ALL PAGES | | | FOR SEAL). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|