Plan Review Details - Permit 06070499
Plan Review Stops For Permit 06070499
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-10-16 Cont ID  
Sent By rmcdouga Date 2006-10-16 Time 08:03 Rev Time 0.00
Received By rmcdouga Date 2006-10-16 Time 07:25 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-03 Cont ID  
Sent By rmcdouga Date 2006-10-03 Time 07:51 Rev Time 0.00
Received By rmcdouga Date 2006-10-03 Time 07:51 Sent To  
Notes
2006-10-03 00:00:00DENIED BY BUILDING
  
 1) THRESHOLD BUILDINGS REQUIRE THREE
 SETS OF SIGNED AND SEALED PLANS. CITY
 AMENDMENTS TO FBC 106.1 AND 109.3.6.
 SOME OF THE PAGES ARE MISSING FROM
 PLANS. THREE COMPLETE SETS ARE REQUIRED.
 SEE PLUMBING REVIEW COMMENTS.
  
 2) PREVIOUS COMMENTS HAVE BEEN ADDRESSED
 BY ENGINEER'S LETTER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-18 Cont ID  
Sent By rmcdouga Date 2006-09-18 Time 16:26 Rev Time 0.00
Received By rmcdouga Date 2006-09-18 Time 16:26 Sent To  
Notes
2006-09-18 00:00:00DENIED BY BUILDING
  
 1) THRESHOLD BUILDINGS REQUIRE THREE
 SETS OF SIGNED AND SEALED PLANS. CITY
 AMENDMENTS TO FBC 106.1 AND 109.3.6.
  
 2) PREVIOUS COMMENTS HAVE BEEN ADDRESSED
 BY ENGINEER'S LETTER.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-10 Cont ID  
Sent By rmcdouga Date 2006-08-10 Time 14:05 Rev Time 0.00
Received By rmcdouga Date 2006-08-10 Time 07:19 Sent To  
Notes
2006-08-10 00:00:00DENIED
  
 1)13-412.1.ABC.2.6 SWIMMING POOL AND
 SPA TEMPERATURE CONTROLS.
  
 13-412.1.ABC.2.6.1 TIME SWITCHES.
 TIME SWITCHES SHALL BE INSTALLED ON
 SWIMMING POOL HEATERS AND PUMPS.
  
 2) POOL COVERS
 13-412.1.ABC.2.6.2 POOL COVERS .
 HEATED POOLS SHALL BE EQUIPPED WITH A
 VAPOR RETARDANT POOL COVER ON OR AT THE
 WATER SURFACE. POOLS HEATED TO MORE THAN
 90?F (32?C) SHALL HAVE A POOL COVER WITH
 A MINIMUM INSULATION VALUE OF R -12.
  
 3) 13-412.1.ABC.2.6.3 POOL HEATERS.
 POOL HEATERS SHALL BE EQUIPPED WITH A
 READILY ACCESSIBLE ON-OFF SWITCH TO
 ALLOW SHUTTING OFF THE HEATER WITHOUT
 ADJUSTING THE THERMOSTAT SETTING. POOL
 HEATERS FIRED BY NATURAL GAS SHALL NOT
 HAVE CONTINUOUSLY BURNING PILOT LIGHTS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-10-12 Cont ID  
Sent By dpalmer Date 2006-10-12 Time 14:25 Rev Time 0.00
Received By dpalmer Date 2006-10-12 Time 14:25 Sent To P
Notes
2006-10-12 14:47:39STAMPED ON PREVIOUS REVIEW, SAME SHEETS WITH NEW PLUMB
 ADDED ON 8 1/2 X 11.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-10-01 Cont ID  
Sent By dpalmer Date 2006-10-01 Time 10:19 Rev Time 0.00
Received By dpalmer Date 2006-10-01 Time 09:57 Sent To P
Notes
2006-10-01 00:00:00OK, ELECTRICAL PAGES STAMPED.
  
 ** SHEETS FOR BUILDING IS NOT PART OF
 THIS PERMIT AND THOSE SHEETS ARE FOR
 REFERENCE ONLY AND ANY REVSIONS WHICH
 ARE NEEDED, NEED TO BE SUBMITTED UNDER
 THE MAIN BUIDLING PERMIT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-17 Cont ID  
Sent By dpalmer Date 2006-09-17 Time 13:33 Rev Time 0.00
Received By dpalmer Date 2006-09-17 Time 13:24 Sent To P
Notes
2006-09-17 00:00:00*** UNSAT ***
  
 1) NOTE: PLEASE SEE THAT THE ELECTRICAL
 PLANS OK, HOWEVER BEING THAT THIS IS A
 THRESHOLD PROJECT, A MINIMUM OF THREE
 SETS ARE REQUIRED FOR REVIEW AND
 STAMPING.
  
 106.1, 109.3.6
  
 THERE IS NO NEED TO SUPPLY THE
 ELECTRICLA PLANS REFERENCE UNDER THE
 BASE BUILDING PERMIT/PLANS.
 ONLY THE PLANS FROM THE POOL ENGINEER.
  
 IF THERE ARE ANY QUESTIONS, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-28 Cont ID  
Sent By dpalmer Date 2006-07-28 Time 07:04 Rev Time 0.00
Received By dpalmer Date 2006-07-27 Time 21:08 Sent To P
Notes
2006-07-28 00:00:00******** USNAT ********
  
 1) NOTE: PLEASE ADJUST VALUE FOR SCOPE
 OF WORK. PLEASE KNOW VALUE SHALL INCLUDE
 ALL LABOR AND MATERIALS, EVEN IF ANY
 MATERIALS ARE OWNER SUPPLIED.
 FBC 108.3
 PLEASE KNOW THAT THIS OFFICE MAY ASSESS
 A VALUE BASED ON THE GUIDES ADOPTED
 UNDER THE FBC.
 VALUE IS CURRENTLY VERY LOW.
  
 2) NOTE: PLEASE PROVIDE AN ELECTRICLA
 WIRING DIAGRAM SHOWING ALL BRANCH
 CIRCUITS TO EQUIPMENT ALONG WITH OCP,
 AND CONDUCTOR SIZES.
 PLEASE SUBMIT A PANEL SCHEDULE FOR
 EQUIPMENT INDICATING ALL EQUIPMENT.
 PLEASE NOTE WHERE PANEL LOCATION IS.
 PLEASE SEE MINIMUM WORKIGN CLEARENCES
 SHALL BE MET FOR DISCONNECTING MEANS
 ETC, THE ROOM SEEMS TO CONTAIN EQUIPMENT
 IN MANY AREAS AND AS NO ELECTRICAL IS
 SHOWN, MINCLEARENCES ETC CAN NOT BE
 VERIFIED.
 PLEASE COMPLETE .
 240.4,310.16,110.26, 408.4 ETC
 FBC 106.1.2 ADMIN SECT.
  
 3) NOTE: PLEASE BE SURE THE RAISED SEAL
 ON PLANS ARE CLEAR AND VISABLE WITH ALL
 INFORMATION ON ENGINEER'S SAID SEAL.
 FS 471.025 FAC 61G15-23.002, .001
 THIS IS REQUIRED FOR ALL SHEETS AND FOR
 ALL TRADES WHETHER OR NOT COMMENT IS
 MADE BY OTHER REVIEWER(S).
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-10-13 Cont ID  
Sent By mperson Date 2006-10-13 Time 11:14 Rev Time 0.00
Received By mperson Date 2006-10-13 Time 11:14 Sent To B
Notes
2006-10-13 11:17:26CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED.
 ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINALINSPECTION.
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-08-01 Cont ID  
Sent By mperson Date 2006-08-01 Time 10:35 Rev Time 0.00
Received By mperson Date 2006-08-01 Time 10:35 Sent To B
Notes
2006-08-01 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-11 Cont ID  
Sent By adarroug Date 2006-10-11 Time 09:03 Rev Time 0.00
Received By adarroug Date 2006-10-11 Time 09:03 Sent To E
Notes
2006-10-11 09:04:15TO "DPALMER" DESK/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-28 Cont ID  
Sent By adarroug Date 2006-09-28 Time 10:05 Rev Time 0.00
Received By adarroug Date 2006-09-28 Time 10:05 Sent To E
Notes
2006-09-28 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 18:02 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 18:02 Sent To E
Notes
2006-09-09 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-27 Cont ID  
Sent By adarroug Date 2006-07-27 Time 17:38 Rev Time 0.00
Received By adarroug Date 2006-07-27 Time 17:38 Sent To E
Notes
2006-07-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-10 Cont ID  
Sent By rmcdouga Date 2006-08-10 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2006-07-12 Time 16:49 Sent To  
Notes
2006-07-12 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-10-13 Cont ID  
Sent By mperson Date 2006-10-13 Time 11:00 Rev Time 0.33
Received By mperson Date 2006-10-13 Time 10:59 Sent To G
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-10-02 Cont ID  
Sent By mperson Date 2006-10-02 Time 08:53 Rev Time 0.33
Received By mperson Date 2006-10-02 Time 08:52 Sent To B
Notes
2006-10-02 00:00:00DENIED 3RD TIME
  
 THE FOLLOWING INFORMATION IS STILL
 REQUIRED FOR PLUMBING PLAN REVIEW:
  
 1. PER FBC-2004 PLUMBING, SECTION
 802.2.1 AIR GAP:THE AIR GAP BETWEEN
 THE INDIRECT WASTE AND THE FLOOD RIM OF
 THE WATSTE RECEPTOR SHALL BE A MINIMUM
 OF TWICE THE EFFECTIVE OPENING OF THE
 INDIRECT WASTE PIPE.
 NOTE: PLEASE CORRECT SHEET SP-1.07 POOL
 WASTE LINE DETAIL FROM A THREE INCH AIR
 GAP TO A SIX INCH AIR GAP FOR THE
 RESUBMITTAL.
 2. THE RESUBMITTED PRINTS ON SHEETS
 SP-1.07 AND SP-2.03 NEED TO HAVE A NEW
 REVISION DATE FOR THE NEW RESUBMITTED
 DETAILS INDICATING THE NEW REVISED POOL
 AND SPA WASTE LINE DETAILS.
 3. THE RESUBMITTED PRINTS NEED TO BE
 CORRELATED SO THAT THE NEW POOL AND SPA
 WASTE LINE DETAILS ARE IN ALL THREE
 RESUBMITTED SETS OF PRINTS.
 NOTE: A) REVISED SHEET SP-1.07 IS
 MISSING ON ONE OF THE THREE RESUBMITTED
 SETS.
 B) REVISED SHEET SP-2.03 IS
 MISSING ON TWO OF THE THREE RESUBMITTED
 SETS.
 4. PLEASE DELETE THE POOL AND SPA WASTE
 DETAILS THAT HAVE BEEN CROSSED OUT IN
 RED INK AND ARE NOT CODE COMPLIANT ON
 SHEETS SP-2.03 AND SP-2.04 AND ONLY
 RESUBMIT THE NEW POOL AND SPA WASTE
 DETAILS.
 5. SEE ATTACHED NOTICE FLORIDA STATUTE
 553.80(2)(B) REGUARDING FOUR (4) TIMES
 THE FEE.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-09-18 Cont ID  
Sent By mperson Date 2006-09-18 Time 09:03 Rev Time 0.45
Received By mperson Date 2006-09-18 Time 09:03 Sent To B
Notes
2006-09-18 00:00:00******DENIED 2ND TIME******
 REFERENCE: FBC-2004 SEC. 424.1 PUBLIC
 SWIMMING POOLS.
 FBC-2004 CHAPTER 1
 FBC-2004 PLUMBING
  
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW:
  
 1. THE POOL WASTE LINE AIR GAP DETAIL
 INDICATED ON SHEETS SP-1.07 AND SP-2.04
 ARE UNACCEPTABLE. A MINIMUM AIR GAP OF
 6" IS REQUIRED FOR A 3" WASTE PIPE PER
 FBC-2004 PLUMBING SECTION 802.2.1.
 PLEASE NOTE THE DEFINITION OF AIR GAP.
 AIR GAP (DRAINAGE SYSTEM)- THE
 UNOBSTRUCTED VERTICAL DISTANCE THROUGH
 THE FREE ATMOSPHERE BETWEEN THE OUTLET
 OF THE WASTE PIPE AND THE FLOOD LEVEL
 RIM OF THE RECEPTACLE INTO WHICH THE
 WASTE PIPE IS DISCHARGING.
 NOTE: PLEASE SEE THE CORRECTED DRAWING
 IN RED ON SHEET SP-1.07 FOR REFERENCE
 FOR RESUBMITTAL.
 2. NOTE: THIS IS A THRESHOLD PROJECT, A
 MINIMUM OF THREE COPIES REQUIRED FOR
 REVIEW AND STAMPING PER FBC-2004 CHAPTER
 1 SECTION 106.1 AND SECTION 109.3.6.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-08-01 Cont ID  
Sent By mperson Date 2006-08-01 Time 09:29 Rev Time 2.00
Received By mperson Date 2006-08-01 Time 09:29 Sent To G
Notes
2006-08-01 00:00:00******DENIED******
 REFERENCE: FBC-2004, SECTION 424.1.
 SWIMMING POOLS:
  
 THE FOLLOWING CORRECTIONS AND INFORMA-
 TION IS REQUIRED FOR PLUMBING PLAN
 REVIEW:
  
 1) PLEASE CORRELATE SHEET SP-1.04, SWIM-
 MING POOL PIPING PLAN AND SHEET SP-1.06,
 SWIMMING POOL SCHEDULE OF EQUIPMENT IN
 RELATION TO ITEM #4 EQUALIZER FITTING
 AND ITEM #5 GUTTER DRAINS. THESE ITEMS
 ARE NUMBERED INCORRECTLY ON SHEET
 SP-1.04. ALSO ON SHEET SP-1.06 PIPING
 SUPPORT DETAIL THE GUTTER DRAIAN IS
 INCORRECTLY INDICATED AS AN EQUALIZER
 FITTING. PLEASE CORRECT ANDSEE
 CORRECTED DRAWING IN RED INK FOR
 REFERENCE FOR RESUBMITTAL.
 2) PLEASE NOTE THAT ON SHEETS SP-1.07,
 SP-2.03 AND SP-2.04 THE POOL AND SPA
 WASTE LINE AIR GAP DETAILS INDICATE THE
 POOL EQUIPMENT BEING DRAINED INTO THE
 STORM SEWER SYSTEM, THIS IS INCORRECT,
 THEY SHALL DRAIN INTO TRAPPED HUB DRAINS
 INTO THE SANITARY SYSTEM. PLEASE CORRECT
 AND SEE CORRECTED DRAWING IN RED INK FOR
 REFERENCE FOR RESUBMITTAL.
 3) ON SHEETS SP-1.07 AND SP-2.01 GAS
 POOL HEATERS ARE INDICATED PLEASE
 PROVIDE MANUFACTURER CUT SHEETS WITH THE
 FOLLOWING INFORMATION.
 (A) FBC-2004 SEC. 424.1.6.5.14 SWIMMING
 POOL WATER HEATERS SHALL BEAR THE LABEL
 OF A RECOGNIZED TESTING AGENCY.
 (MANUFACTURE SHEETS REQUIRED, PLEASE
 SUBMIT)
 (B) WATER RETENTION, PROVIDE A POSITIVE
 MEANS OF RETAINING WATER IN THE HEATER
 WHEN PUMP IS SHUT OFF.(MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
 4) PLEASE SEE ELECTRICAL COMMENT #3
 REGUARDING ENGINEER'S SEAL.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-10-18 Cont ID  
Sent By aaponte Date 2006-10-18 Time 11:59 Rev Time 0.00
Received By aaponte Date 2006-10-18 Time 11:58 Sent To  
Notes
2006-10-18 12:00:55LANDSCAPE AND ROOF TERRACE INCLUDED IN MAIN PERMIT

Review Stop Z ZONING
Rev No 1 Status P Date 2006-07-25 Cont ID  
Sent By mflis Date 2006-07-25 Time 15:33 Rev Time 0.00
Received By mflis Date 2006-07-25 Time 15:33 Sent To  
Notes
2006-07-25 00:00:00POOL REVIEW; LANDSCAPE REQS TO BE
 REVIEWED WITH LANDSCAPE SUBMITTAL.
 MJF