| Plan Review Stops For Permit 06070422 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-12 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-12 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-16 |
Time |
06:41 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-16 |
Time |
05:44 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-10-14 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-10-14 |
Time |
14:11 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-08-07 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-08-07 |
Time |
09:24 |
Sent To |
PC |
|
| Notes |
| 2006-08-07 00:00:00 | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. THE NEW LOCATION IS2300 | | | N. JOG RD (NORTH OF OKEECHOBEE BLVD) | | | SUITE#2W01-2W14. | | | | | | 2) FBC 13-103.1.2 BEFORE A BUILDING | | | PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | | SIGNED BY THE BUILDING OWNER, THE | | | OWNER'S ARCHETECT OR OTHER AUTHORIZED | | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | TWO COPIES REQUIRED. ONLY ONE WAS | | | SUBMITTED. | | | | | | 3) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 4) IF THE NEW WINDOWS ARE NON-IMPACT, | | | HURRICANE PROTECTION IS REQUIRED. SUBMIT | | | PRODUCT APPROVALS FOR SHUTTERS FOR THE | | | NEW WINDOWS. | | | | | | 5) WHERE IS THE NEW LAUNDRY ROOM | | | LOCATED? | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-26 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-26 |
Time |
10:24 |
Sent To |
PC |
|
| Notes |
| 2007-11-26 10:38:11 | REDLINED WATER HEATER WHICH IS MISSING FROM PANEL | | | SCHEDULE. | | | PLANS AND LOAD CALCULATIONS DO INDICATEA WH. | | | NEED TO REVISE BEFORE FINAL. | | | 240.4, 310.16, 408.4. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-27 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-27 |
Time |
12:19 |
Sent To |
PC |
|
| Notes |
| 2007-10-27 12:19:37 | ** DENIED REVISION ** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS *PROVISO* ARE STILL | | | IN NEED OF ADDRESSING. PLEASE ALSO SEE THERE ARE NEW | | | NOTES AS PLANS HAVE BEEN REVISED WITH SOME ITEMS WHICH | | | ARE NOT CODE COMPLIANT. | | | | | | 1) NOTE: PLEASE SEE THE SMOKE ALARMS WHICH WERE TO BE | | | CORRECTED TO THE EXISTING DWELLING AS WELL WAS NOT | | | SUBMITTED. | | | PLEASE SEE FBC R313, NFPA-72 11.5.1.1 | | | | | | 2) NOTE: PLEASE SEE THE WATER DISCONNECT IS NOW | | | MISSING. | | | 422.31. | | | | | | 3) NOTE: PLEASE SEE THE ELECTRICAL PANEL IS NOW BEING | | | SHOWN IN THE CLOSET ARE WITH THE WASHER AND DRYER AND | | | ALSO DOES NOT MEET 110.26 FOR MINIMUM WORKING | | | CLEARANCES PER 110.26. | | | PLEASE ALSO SEE 240.24D, AND 408.7 | | | PANEL IS TO BE RELOCATED. | | | | | | 4) NOTE: PLEASE SEE THE PANEL SCHEDULE WAS NOT | | | COMPLETELY REVISED INDICATING ALL NEW CIRCUITS. PLEASE | | | SEE SOME BRANCH CIRCUITS FOR LIGHTING AND RECEPTACLES | | | HOWEVER WASHER, DRYER ETC IS THE SAME. | | | PLEASE SEE IN FACT WASHER CIRCUIT IS MISSING FROM THE | | | PANEL SCHEDULE. | | | PLEASE ALSO SEE SMALL APPLIANCE CIRCUIT #32 FOR BRKFST | | | ROOM IS SHOWN ON LIGHTING CIRCUIT FOR COVERED PATIO. IF | | | EXISTING OK, IF NEW THIS DOES NOT MEET 210.52B1, | | | 210.11C1, 220.16 | | | PLEASE ADJUST PANEL SCHEDULE AS NEEDED. 408.4, 310.16, | | | 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 5) NOTE: PLEASE ONLY SUBMIT ELECTRICAL PLANS WHICH ARE | | | BEING REVISED. PLEASE SEE THE TITLE BLOCKS OF PLANS DO | | | NOT INDICATE THE REVISIONS, CLOUDS AND TRIANGLES WITH | | | DATES. | | | PLEASE SEE THE SHEETS CONTAIN ALL OTHER TRADES WHEN | | | ONLY ELECTRICAL IS NEEDED. | | | FBC 106.3.1 | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-12 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-12 |
Time |
08:07 |
Sent To |
B |
|
| Notes |
| 2007-07-12 09:55:57 | *** PROVISO *** | | | | | | 1) NOTE: PLEASE SEE PANEL SCHEDULE SHOWS ALL CIRCUITS | | | AS NEW. PLEASE REVISE TO INDICATE WHICH ARE NEW AND | | | WHICH ARE EXISTING? | | | 408.4 | | | | | | 2) NOTE: PLEASE SEE THE SMOKE DEVICES AS INDICATE FOR | | | NEW AND EXISTING DWELLING SHOULD BE INDICATED AS SA FOR | | | SMOKE ALARMS. | | | PLEASE SEE NFPA-72 DEFINITIONS AND 11.5.1.1.1 | | | | | | 3) NOTE: PLEASE SEE ONE OR MORE OF THE SMALL APPLIANCE | | | CIRCUITS SHALL BE SHOWN AND FIGURED AT 1500 VA FOR | | | EACH. ONLY TWO ARE SHOWN ON LOAD CALCULATIONSYET | | | THREE ARE SHOWN ON PANEL SCHEDULE. | | | 210.52B1, 220.16 | | | | | | ** PLEASE REVISED THE ABOVE INFORMATION ON AN | | | ELECTRICAL PLAN/SHEET AND SUBMIT WITH ANY OTHER | | | POSSIBLE REVISIONS BEFORE ROUGH ELECTRICAL INSPECTION. | | | THE REVISED PLANS MUST BE ON-SITE FOR ROUGH ELECTRICAL | | | INSPECTION. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-30 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-30 |
Time |
07:21 |
Sent To |
M |
|
| Notes |
| 2006-11-30 07:43:58 | *** UNSAT *** | | | | | | *** PLEASE SEE NOTES FROM PREVIOUS REVIEWS WHICH STILL | | | NEED TO BE ADDRESSED. | | | | | | | | | 1) NOTE: PLEASE SEE NO PANEL SCHEDULE WAS SUBMITTED FOR | | | CIRCUITING AS REQUESTED ON BOTH PREVIOUS REVIEWS. THIS | | | WOULD INDICATE THE CIRCUITS (NEW) AND EXISTING, THE | | | BRANCH CIRCUIT , ALONG WITH THE OVER CURRENT PROTECTION | | | AND CONDUCTOR SIZES. | | | 310.16,240.4,408.4 ETC | | | FBC 106.1.2, 106.3.5.4 ADMIN SECTION. | | | | | | | | | 2) NOTE: PLEASE SEE NOW LOAD CALCULATIONS ARE BEING | | | SUBMITTED FOR THE FIRST TIME FOR REVIEW. PLEASE SEE | | | THESE NOTE VERIFY A 200A SERVICE, YET THE RISER SHOWS | | | AN EXISTING 150A SERVICE? WHICH IS IT? | | | PLEASE ALSO SEE THERE ARE 2/0?S BEING SHOWN FROM RISER | | | TO MAIN PANEL.(EXISTING)?? | | | PLEASE KNOW THIS IS THE RESPONSIBILITY OF THE DESIGNER | | | OF RECORD TO OBTAIN THIS INFORMATION AND PLACE THIS | | | INFORMATION ON PLANS ACCURATELY. | | | FBC 106.1.2 ADMIN SECTION. | | | NEC 230.70, 310.16, 240.4 ETC. | | | | | | 4) NOTE: PLEASE KNOW AS NOTED ON PREVIOUS2ND REVIEW | | | WITH RESPECT TO REPEAT CODE COMPLIANT COMMENTS TO THE | | | DESIGN PROFESSIONAL, A FEE OF $312.00 BASED ON 4X THE | | | FEE FOR THE PORTION THE FEE ATTRIBUTED TO PLAN REVIEW | | | HAS BEEN ASSESSED AS REQUIRED UNDER FS 553.80(2)(B). | | | THIS FEE SHALL BE PAID BEFORE NEXT RESUBMISSION OF | | | PLANS. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | ** TO DATE NO CONTACT HAS BEEN MADE TO THIS OFFICE TO | | | GO OVER SAID COMMENTS OR ANY QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-10-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-01 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-01 |
Time |
11:44 |
Sent To |
M |
|
| Notes |
| 2006-10-01 00:00:00 | *****UNSAT 2ND REVIEW ******** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEW | | | WHICH STILL NEED TO BE ADDRESSED AND | | | PLEASE SEE NEW COMMENTS BASED ON PLANS | | | AND SPECS SUBMITTED. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW. | | | | | | 1) NOTE: NO, LOAD CALCULATIONS | | | SUBMITTED, DO NOT CORRELATE WITH ANY | | | CALCULATIONS BASED FROM THE NFPA-70 OR | | | IS PERMITTED IN THE NEC. | | | ** PLEASE SEE 220.312B AND COMPLETE. | | | PLEASE SEE THERE IS A MAJOR LOAD BEING | | | ADDED, HOWEVER THERE HAS BEEN NOT | | | CONSIDERATION FOR THIS. PLEASE SEE SPECS | | | FOR TANKLESS WATER HEATER SUBMITTED | | | WHICH "HIGH-LIGHTS" A 28KW UNIT!!!! THIS | | | UNITS ALONE PULLS 116A'S. | | | PLEASE SEE THE LOAD ON THIS UNIT ALONE | | | AND THE MIN LOADS ON THE EXISTING | | | DWELLING FAR EXCEED THE RATING OF THE | | | EXISTING DWELLING'S SERVICE. | | | PLEASE OBTAIN A QUALIFIED PERSON WHO HAS | | | ELECTRICAL BACKGROUND TO THESE AS THIS | | | IS LIFE SAFETY AND FIREHAZARD AND DUE | | | TO WHAT IS BEING SUBMITTED. | | | PLEASE SEE NO INFORMATION AND LCOATION | | | OF UNIT AT THIS TIME IS "NOT" PERMITTED. | | | ** PLEASE ALSO SEE THERE IS NO NRTL( | | | NATIONALLY RECOGNIZED TESTING | | | LABORATORY) SHOWN ON SPECS. PLEASE ALSO | | | SUBMIT TWO COPIES. | | | PLEASE SEE NO NEW REVISED PANEL SCHEDULE | | | WAS SUBMITTED EITHER TO VERIFY THE NEW | | | CIRCUITS, CONDUCTORS, OCP, LOADS ETC. | | | 110.3,240.24,110.26,90.7,220.31B, 408.4, | | | 240.4, 310.16 ETC. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SUBMIT COMPLETE LOAD | | | CALCULATIONS SHOWING ALL EXISTING AND | | | NEW LOADS. | | | INDICATE THE SIZE OF THE NEW TANKLESS | | | WH. PLEASE SEE MANUFACTURES SPECS / CUT | | | SHEETS FOR MIN CLEARENCES AND LOCATION. | | | PLEASE SEE CLARIFY WHERE THE MEANS OF | | | DISCONNECT IS? | | | PLEASE SEE LOCATION BEING PRIMARILY | | | STORAGE UNDER LAV AND LOCATION DUE TO | | | EASILY IGNITIBLE MATERIALS. | | | PLEASE SUBMIT THE MANUFACTURES SPECS/ | | | CUT SHEETS FOR THE PROPOSED UNIT. | | | PLEASE SEE 110.26,422.31,110.3,240.24, | | | 220.31, 408.4 ETC. | | | | | | 2) NOTE: OK. | | | | | | 3) NOTE:NO, SAME NOTE, NOTHING SHOWN | | | OR SUBMITTED. | | | | | | ** PREVIOUS REVIEW NOTE **PLEASE SEE | | | 2004 R313 AS SD'S | | | ARE REQUIRED INSIDE AND OUTSIDE ALL | | | EXISTING SLEEPING RMS. PLEASE SEE | | | NFPA-72 11.5.1.1,11.8.3. | | | PLEASE SHOW A BASIC LAYOUT OF THE | | | EXISTING DWELLING AND THE LOCATION OF | | | THE SD'S. | | | | | | 4) NOTE: NO, NOT CLEAR A NEW LOCATION | | | SEEMS TO BE SHOWN BASED ON SYMBOL OF | | | WHAT THE WASHER AND DRYER SHOULD BE, | | | HOWEVER NOTHING IDENTIFING NEW | | | EQUIPMENT. PLEASE SEE IF NEW STACKABLE | | | UNIT, PLEASE SHOW, AND PLEASE INDICATE | | | IN NEW LOADS/PANEL SCHEDULE. | | | 220.16, 210.11C2, 220.18 | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE PERMIT APPLICATION | | | MENTIONS CONVERTING EXISTING LAUNDRY RM | | | TO BATHRM, HOWEVER NEW LANUDRY AREA CAN | | | NOT BE LOCATED. PLEASE SEE MIN HOUSING | | | CODE FOR LAUNDRY FACILIES AND PLEASE SEE | | | NEC FOR MIN LAUNDRY CIRCUITS. | | | 210.11C2, 220.16 | | | | | | | | | ** NEW NOTE ** | | | | | | 1) NOTE: PLEASE SEE ONE SET OF PLANS | | | HAVE BEEN RETAINED BY THIS OFFICE AND | | | WILL BE PLACED IN FILE WITH ALL OTHER | | | PROJECTS REPEATLY BEING SUBMITTED, | | | SIGNED , DATED AND SEALED BY THIS DESIGN | | | PROFESSSIONAL.PLEASE SEE NOTICE TO FS | | | 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS FOR PLAN REVIEW IS NOW GIVEN AS | | | NOTICE. | | | PLEASE ALSO SEE FS 471.025(3) QUOTED, | | | "NO LICENSEE SHALL AFFIX OR PERMIT TO | | | BE AFFIXED HIS OR HER SEAL, NAME, OR | | | DIGITAL SIGNATURE TO ANY PLAN, | | | SPECIFICATION, DRAWING, FINAL BID | | | DOCUMENT, OR OTHER DOCUMENT THAT DEPICTS | | | WORK WHICH HE OR SHE IS NOT LICENSED TO | | | PERFORM OR WHICH IS BEYOND HIS OR HER | | | PROFESSION OR SPECIALTY THEREIN." | | | THIS IS TAKEN DIRECTLY FROM THE TEXT OUT | | | OF THE FLORIDA STATUES. | | | | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-20 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-20 |
Time |
07:02 |
Sent To |
M |
|
| Notes |
| 2006-07-20 00:00:00 | ******UNSAT ******** | | | | | | 1) NOTE: PLEASE SUBMIT COMPLETE LOAD | | | CALCULATIONS SHOWING ALL EXISTING AND | | | NEW LOADS. | | | INDICATE THE SIZE OF THE NEW TANKLESS | | | WH. PLEASE SEE MANUFACTURES SPECS / CUT | | | SHEETS FOR MIN CLEARENCES AND LOCATION. | | | PLEASE SEE CLARIFY WHERE THE MEANS OF | | | DISCONNECT IS? | | | PLEASE SEE LOCATION BEING PRIMARILY | | | STORAGE UNDER LAV AND LOCATION DUE TO | | | EASILY IGNITIBLE MATERIALS. | | | PLEASE SUBMIT THE MANUFACTURES SPECS/ | | | CUT SHEETS FOR THE PROPOSED UNIT. | | | PLEASE SEE 11.26,422.31,110.3,240.24, | | | 220.31, 408.4 ETC. | | | | | | 2) NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52 FOR MORE THAN 2' OF WALL SPACE. | | | | | | 3) NOTE: PLEASE SEE 2004 R313 AS SD'S | | | ARE REQUIRED INSIDE AND OUTSIDE ALL | | | EXISTING SLEEPING RMS. PLEASE SEE | | | NFPA-72 11.5.1.1,11.8.3. | | | PLEASE SHOW A BASIC LAYOUT OF THE | | | EXISTING DWELLING AND THE LOCATION OF | | | THE SD'S. | | | | | | 4) NOTE: PLEASE SEE PERMIT APPLICATION | | | MENTIONS CONVERTING EXISTING LAUNDRY RM | | | TO BATHRM, HOWEVER NEW LANUDRY AREA CAN | | | NOT BE LOCATED. PLEASE SEE MIN HOUSING | | | CODE FOR LAUNDRY FACILIES AND PLEASE SEE | | | NEC FOR MIN LAUNDRY CIRCUITS. | | | 210.11C2, 220.16 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
| 2007-11-19 16:41:35 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-26 |
Time |
16:06 |
Sent To |
E |
|
| Notes |
| 2007-10-26 16:07:25 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2006-11-29 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2006-11-29 |
Time |
17:08 |
Sent To |
E |
|
| Notes |
| 2006-11-29 17:09:15 | SENT TO DEWEY PALMER'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-20 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-20 |
Time |
08:55 |
Sent To |
Z |
|
| Notes |
| 2006-11-20 08:56:01 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-26 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-26 |
Time |
14:13 |
Sent To |
E |
|
| Notes |
| 2006-09-26 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-21 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-21 |
Time |
10:16 |
Sent To |
Z |
|
| Notes |
| 2006-09-21 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-18 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-18 |
Time |
11:36 |
Sent To |
E |
|
| Notes |
| 2006-07-18 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-08-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-11 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2006-07-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-30 |
Time |
08:08 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-11-30 |
Time |
08:08 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-02 |
Time |
11:31 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-02 |
Time |
11:31 |
Sent To |
P |
|
| Notes |
| 2006-10-02 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS ARE OK, SEE | | | ELECTRICAL REVIEW NOTES, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-20 |
Time |
09:26 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-07-20 |
Time |
09:26 |
Sent To |
P |
|
| Notes |
| 2006-07-20 00:00:00 | | | | *** DENIED *** | | | 1) NEED TWO COPYS OF THE ENERGY | | | CALCULATIONS, ONLY ONE WAS SUBMITTED. | | | | | | 2) ENERGY CALCULATIONS NEED TO BE SIGNED | | | BY OWNER/AGENT, PER 2004 FBC | | | 13-600.3.ABC.2 | | | | | | 3) SHOW ON PLANS THE NEW LOCATION OF THE | | | CLOTHES WASHER AND DRYER, AND THE | | | CLOTHES DRYER VENT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-12-09 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-12-09 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-14 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-14 |
Time |
09:44 |
Sent To |
B |
|
| Notes |
| 2006-10-14 09:52:23 | DENIED; | | | 1. (NOTE 2 FROM LAST REVIEW WAS NOT ADDRESSED).PLEASE | | | PROVIDE MANUFACTURE'S INSTALLATION INSTRUCTIONS | | | 2.AUTOMATIC CLOTHES WASHER MUST HAVE A 2" TRAP MIN. NOT | | | 1 1/2"CLEANOUT TO BE AT 48" AFF. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-24 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-24 |
Time |
10:16 |
Sent To |
B |
|
| Notes |
| 2006-07-24 00:00:00 | DENIED; | | | 1.PLEASE SHOW NEW LOCATION OF LAUNDRY | | | FIXTURES. AUTOMATIC CLOTHES WASHER IS | | | REQUIRED TO MEET MINIMUM PLUMBING CODE | | | SEE FBC-2004 PLUMBING TABLE 403.1 R-3. | | | ALSO SEE SECTION 406.3 DRAIN FOR NEW W/M | | | IS REQUIRED TO BE 3". | | | 2.PROVIDE MANUFACTURE INSTALLATION | | | INSTRUCTIONS FOR NEW WATER | | | HEATER,CLEARANCES AND ACCESSABLITY COULD | | | BE A PROBLEM. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-26 |
Time |
22:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-26 |
Time |
22:24 |
Sent To |
I |
|
| Notes |
| 2006-11-26 22:24:27 | PROVISO: ENCLOSING THE EXISTING CARPORT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-23 |
Time |
10:22 |
Sent To |
I |
|
| Notes |
| 2006-09-23 00:00:00 | PROVISO: ENCLOSING THE EXISTING CARPORT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-16 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-16 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-16 |
Time |
13:36 |
Sent To |
I |
|
| Notes |
| 2006-07-16 00:00:00 | DENIED, | | | 1. PLEASE SUBMIT A COPY OF EXISTING | | | SURVEY, SHOWING THE EXISTING CARPORT | | | WITH SETBACKS. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|