Plan Review Details - Permit 06070395
Plan Review Stops For Permit 06070395
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-07-14 Cont ID  
Sent By amorse Date 2007-07-14 Time 10:17 Rev Time 0.00
Received By amorse Date 2007-07-14 Time 10:17 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-09-03 Cont ID  
Sent By amorse Date 2006-09-03 Time 10:22 Rev Time 0.00
Received By amorse Date 2006-09-03 Time 10:22 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-27 Cont ID  
Sent By amorse Date 2006-07-26 Time 13:11 Rev Time 0.00
Received By amorse Date 2006-07-26 Time 13:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-08-02 Cont ID  
Sent By dpalmer Date 2007-08-02 Time 13:56 Rev Time 0.00
Received By dpalmer Date 2007-08-02 Time 13:48 Sent To PC
Notes
2007-08-02 14:07:33REVISED PLANS FOR FINAL.
 REVISED ENGINEER OF RECORD.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-07-16 Cont ID  
Sent By dpalmer Date 2007-07-16 Time 11:54 Rev Time 0.00
Received By dpalmer Date 2007-07-16 Time 11:49 Sent To PC
Notes
2007-07-16 13:19:04** UNSAT **
  
 1) NOTE: PLEASE SEE THE SMOKE ALARMS ARE REQUIRED
 INSIDE AND OUTSIDE BEDROOM/SLEEPING ROOMS. PLEASE SEE
 LOCATION IS NOT AS SHOWN ON PREVIOUS PLANS. NFPA-72
 11.5.1.1
 THESE ARE SMOKE ALARMS NOT SMOKE DETECTORS AS SHOWN.
 THIS WAS REDLINED ON OTHER UNITS. SEE NFPA-72
 DEFINITIONS.
  
 2) NOTE: PLEASE SEE THE CIRCUIT FOR THE SMOKE ALARMS IS
 SHOWN ON CIRCUIT #8 WHEN PLANS INDICATE #10. PLEASE
 CORRELATE.
  
 3) NOTE: PLEASE SEE THE PANEL SCHEDULE IS SHOWING THE
 LOAD FOR WHAT APPEARS TO BE THE SECOND SMALL APPLIANCE
 CIRCUIT AT 450VA. IS THIS THE FRIG? PLEASE SEE THE
 PLANS ARE MISSING THE CIRCUIT NUNMBER DESIGNATION ON
 THE RECEPT IN KITCHEN NEXT TO PANEL. THIS DEVICE HAS
 TYPICALLY BEEN THE SECOND SMALL APPLIANCE IN OTHER
 UNITS.
 210.52B1, 210.11C1, 220.16
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 561-805-6717

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-24 Cont ID  
Sent By dpalmer Date 2006-12-24 Time 09:12 Rev Time 0.00
Received By dpalmer Date 2006-12-24 Time 09:09 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-09-01 Cont ID  
Sent By dpalmer Date 2006-09-01 Time 09:07 Rev Time 0.00
Received By dpalmer Date 2006-09-01 Time 09:07 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-07-27 Cont ID  
Sent By dpalmer Date 2006-07-27 Time 13:09 Rev Time 0.00
Received By dpalmer Date 2006-07-27 Time 13:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-08-02 Cont ID  
Sent By mwennerg Date 2006-08-02 Time 09:31 Rev Time 0.00
Received By mwennerg Date 2006-08-02 Time 09:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-07-31 Cont ID  
Sent By adarroug Date 2007-07-31 Time 15:48 Rev Time 0.00
Received By adarroug Date 2007-07-31 Time 15:48 Sent To  
Notes
2007-07-31 15:48:39TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-07-12 Cont ID  
Sent By adarroug Date 2007-07-12 Time 11:53 Rev Time 0.00
Received By adarroug Date 2007-07-12 Time 11:53 Sent To E
Notes
2007-07-12 11:53:26TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-12 Cont ID  
Sent By adarroug Date 2007-07-12 Time 10:52 Rev Time 0.00
Received By adarroug Date 2007-07-12 Time 10:52 Sent To B
Notes
2007-07-12 10:52:48TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-17 Cont ID  
Sent By adarroug Date 2006-12-17 Time 17:06 Rev Time 0.00
Received By adarroug Date 2006-12-17 Time 17:06 Sent To E
Notes
2006-12-17 17:06:31TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-15 Cont ID  
Sent By adarroug Date 2006-08-15 Time 16:09 Rev Time 0.00
Received By adarroug Date 2006-08-15 Time 16:09 Sent To  
Notes
2006-08-25 00:00:00TO "BOB"#3
2006-08-15 00:00:00WAITING FOR "BOB"--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-02 Cont ID  
Sent By mwennerg Date 2006-08-02 Time 09:31 Rev Time 0.00
Received By mwennerg Date 2006-07-13 Time 10:52 Sent To  
Notes
2006-07-17 00:00:00WAITING FOR "BOB"
 TO "BOB"#12

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-07-18 Cont ID  
Sent By tgordon Date 2006-07-18 Time 10:43 Rev Time 0.05
Received By tgordon Date 2006-07-18 Time 10:43 Sent To  
Notes
2006-07-18 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-08-05 Cont ID  
Sent By pschmitz Date 2006-08-05 Time 13:16 Rev Time 0.00
Received By pschmitz Date 2006-08-05 Time 13:16 Sent To  
Notes
2006-08-05 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
  
 PROVISO
  
 1) REPLACE EX FIXTURES ONLY
  
 2) REVISION REQUIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-26 Cont ID  
Sent By jleech Date 2006-07-26 Time 10:18 Rev Time 0.00
Received By jleech Date 2006-07-26 Time 10:18 Sent To  
Notes
2006-07-26 00:00:00DENIED;
 SUBMIT DETAIL ON AUTOMATIC CLOTHES
 WASHER OR DELETE NOTE 3 FROM PAGE E-1
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695