| Plan Review Stops For Permit 06070391 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-14 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-07-14 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-07-14 |
Time |
10:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-09-03 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-03 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-03 |
Time |
10:17 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-26 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-07-26 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-02 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-02 |
Time |
13:03 |
Sent To |
PC |
|
| Notes |
| 2007-08-02 13:47:12 | REVISED PLANS FOR FINAL. | | | REVISED ENGINEER OF RECORD. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-16 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-16 |
Time |
16:23 |
Sent To |
PC |
|
| Notes |
| 2007-07-16 16:30:44 | | | | | | | **** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE THE PANEL SCHEDULE INDICATES A | | | SECOND SMALL APPLIANCE CIRCUIT WHICH IS BEING SHARED | | | WITH THE FRIG, HOWEVER THE LOAD IS ONLY SHOWN AT | | | 450VA. | | | PLEASE SEE THE NEW GFI RECEPTACLE ADDED TO KITCHEN | | | CONTAINS A CIRCUIT NUMBER WHICH IS CIRCUITED TO THE | | | LIGHTS. | | | PLEASE SEE 210.52B1 AS THIS IS NOT PERMITTED ON | | | LIGHTING CIRCUIT. | | | PLEASE SEE THIS IS CIRCUIT A-3. | | | PLEASE SEE 210.52B1, 210.11C1, AND 220.16 | | | | | | 2) NOTE: PLEASE SEE AS PLANS ARE COMING BACK FOR | | | CORRECTIONS, PLEASE CORRECT THE DESIGNATION OF THE | | | SMOKE DETECTION DEVICES AS THESE APPEAR TO BE SMOKE | | | ALARMS AND NOT SMOKE DETECTORS PER NFPA-72 | | | DEFINITIONS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-24 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-24 |
Time |
09:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-01 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-01 |
Time |
08:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-27 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-27 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-02 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-02 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-31 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-31 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2007-07-31 15:47:54 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-12 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-12 |
Time |
11:50 |
Sent To |
E |
|
| Notes |
| 2007-07-12 11:50:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-12 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-12 |
Time |
10:54 |
Sent To |
B |
|
| Notes |
| 2007-07-12 10:55:02 | TO "AMORSE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
17:00 |
Sent To |
E |
|
| Notes |
| 2006-12-17 17:00:14 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-15 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-15 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | TO "BOB"#3 | | 2006-08-15 00:00:00 | WAITING FOR "BOB"--NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-02 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-13 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2006-07-17 00:00:00 | TO "BOB"#12 | | 2006-07-13 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-18 |
Time |
10:38 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-07-18 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-26 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-26 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-05 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-05 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | | | | PROVISO | | | | | | 1) REPLACE EX FIXTURES ONLY | | | | | | 2) REVISION REQUIRED. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-26 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-26 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-07-26 00:00:00 | DENIED; | | | SUBMIT DETAIL ON AUTOMATIC CLOTHES | | | WASHER OR DELETE NOTE 3 ON PAGE E-1. | | | PLEASE DISCRIBE PLUMBING WORK TO BE DONE | | | ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH |
|
|