Plan Review Details - Permit 06070322
| Plan Review Stops For Permit 06070322 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-23 |
Time |
15:52 |
Rev Time |
0.50 |
| Received By |
jgomez |
Date |
2006-08-23 |
Time |
15:52 |
Sent To |
PC |
|
| Notes |
| 2006-08-23 00:00:00 | PERMIT UNDER 'Y'. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-08-11 |
Time |
16:33 |
Rev Time |
0.40 |
| Received By |
jgomez |
Date |
2006-08-11 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | BUILDING REVIEW 2ND CHECKLIST: | | | | | | 1- CONTRACTOR STATES IN PERMIT | | | APPLICATION THAT CONCRETE TILE IS TO BE | | | PLACED IN WOOD DECK BATTEN SYSTEM. DADE | | | COUNTY NOA #02-1205.07 FOR MONIER | | | SPANISH 'S' CONCRETE TILE DOESN'T ALLOW | | | BATTEN SYSTEM INSTALLATION. SEE PAGE 4 | | | OF 5 OF NOA. NEED TO PROVIDE PRODUCT | | | APPROVAL THAT ALLOWS BATTEN SYSTEM | | | APPLICATION OR PROVIDE SOLID DECK | | | SYSTEM. | | | PROVIDE COMPLETE STRUCTURAL DRAWINGS AND | | | SPECIFICATIONS FOR SOLID DECKING UNDER A | | | SEPARATE PERMIT FOR STRUCTURAL WORK. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004 | | | AND SEC. 1609 FBC 2004. | | | | | | 2- SELF ADHERING UNDERLAYMENT (FLORIDA | | | PRODUCT APPROVAL FL3732-R1) IS NOT | | | ALLOWED. SEE RAS 120 FOR TYPES OF | | | UNDERLAYMENTS ALLOWED. SPECIFY WHICH | | | UNDERLAYMENT IS GOING TO BE USED. | | | ALSO, ACCORDING TO THE ROOF SLOPE THERE | | | ARE ROOF TILE NAILING REQUIREMENTS. SEE | | | RAS 120 AND PROVIDE NAILING | | | SPECIFICATIONS AS REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-07-12 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2006-07-12 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2006-07-12 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- CONTRACTOR TO PROVIDE ALL INFORMATION | | | AS REQUIRED BY CITY POLICY FOR | | | RE-ROOFING PERMITS. SEE ATTACHED COPY. | | | MISSING MEAN ROOF HEIGHT. | | | | | | 2- PROVIDE UPLIFT PRESSURE CALCULATIONS | | | IF BUILDING MEAN ROOF HEIGHT IS HIGHER | | | THAN 30'-0" TO VERIFY COMPLIANCE OF | | | CONCRETE ROOF TILE AS REQUIRED BY SEC. | | | 1609.7 FBC 2004. | | | | | | 3- UNDERLAYMENT PRODUCT APPROVAL. | | | A) NEED TO PROVIDE THE 2004 FLORIDA | | | PRODUCT APPROVAL VERSION, NOT 2001. | | | B) NEED TO PROVIDE TECHNICAL | | | INFORMATION THAT WAS SUBMITTED TO GET | | | FLORIDA PRODUCT APPROVAL. GO TO THE DCA | | | WEBSITE WWW.FLORIDABUILDING.ORG TO | | | DOWMLOAD ALL INFORMATION. | | | | | | 4- PROVIDE COPY OF FLORIDA PRODUCT | | | APPROVAL COVER PAGE AS REQUIRED BY CITY | | | RE-ROOFING PERMITS FOR MONIER SPANISH | | | "S". CONC. ROOF TILE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-21 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-21 |
Time |
13:59 |
Sent To |
B |
|
| Notes |
| 2006-08-21 00:00:00 | TO "JGOMEZ" DESK/RESUB |
|
|
|
Account Summary | Usage Policy | Privacy Policy