| Plan Review Stops For Permit 06070179 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-07-10 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-25 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | COPY OF APPL. SENT TO LILI | | | NEW ADDRESS 1321 N MANGONIA DR WAS | | | ASSIGNED TO THIS VACANT PARCEL | | | | | | 9-25-06 ENTERED STOP IN ERROR,PES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-13 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-13 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2007-03-13 10:50:44 | REVISION #3 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-02-28 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-02-28 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2007-02-28 17:24:06 | | | | REVISION | | | FEBRUARY 5, 2007 | | | | | | | | | ROOF PITCH CHANGE APPROVED, | | | | | | PGT SINGLE HUNG WINDOW APPROVED, | | | | | | | | | | | | | | | | | | GLASS BLOCK NOT APPROVED ; PLEASE IDENTIFY WHICH SYSTEM | | | AND PROVIDE INSTALLATION DETAILS. | | | | | | PGT FIXED WINDOWS NOT APPROVED; CHOOSE INSTALLATIONS | | | DETAILS FROM ENGINEERING AND PROVIDE INSTALLATION | | | SCHEDULE FOR STORM PANELS. | | | | | | THERMA--TRU DOORS AND ODL GLASS NOT APPROVED; PROVIDE | | | STORM PANEL INSTALLATION SCHEDULE FOR NON--IMPACT | | | GLAZED WINDOWS AND DOORS, CHECK THE MAX. ALLOWABLE | | | SHUTTER SPAN OF 104" AT GLAZED DOORS AND TRANSOMS. | | | | | | | | | | | | | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-25 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-11-25 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-11-25 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-26 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-26 |
Time |
11:10 |
Sent To |
PC |
|
| Notes |
| 2006-09-26 00:00:00 | | | | | | | DENIED | | | | | | 1) THE SUBMITTED TRUSS DRAWINGS SHALL BE | | | SIGNED AND SEALED BY TRUSS MANUFACTURERS | | | ENGINEER. ALSO ONLY ONE COPY OF THE | | | LAYOUT WAS PROVIDED AND 2 WILL BE | | | REQUIRED | | | | | | 2) PLEASE BE AWARE THAT SPECIFIC ANCHORS | | | ARE TO BE LISTED FOR THE TRUSS TIE DOWNS | | | AT ALL LOCATIONS (WALLS, GIRDERS, | | | VALLEYS, ETC.) EITHER BY THE TRUSS | | | MANUFACTURERS DESIGNER OR THE DESIGNER | | | RESPONSIBLE FOR THE PROJECT | | | | | | 3) PRODUCT APPROVALS FOR THE MULLIONS | | | MISSING THE STATE OF FLORIDA COVERS | | | SHEETS (FL# 6868) | | | | | | 4) SOME PRODUCT APPROVALS WERE NOT | | | REVIEWED BY THE DESIGN PROFFESIONAL AS | | | REQUIRED PER 106.3.3 FBC* ( SINGLE HUNG | | | WINDOWS,MULLIONS,STEEL INSULATED DOOR, | | | AND STORM PANELS | | | | | | 5) PRODUCT APPROVALS WERE SUBMITTED FOR | | | CASEMENT/SH EGRESS WINDOWS. PLEASE SEE | | | THAT THE REGULAR SINGLE HUNG SH25 WILL | | | MEET THE EGRESS REQUIREMENTS BECAUSE IT | | | IS 63" TALL AND THAT THE CASEMENT/SH | | | WINDOWS HAVE A MAX HEIGHT OF 50 5/8" | | | ALSO A PRODUCT APPROVAL WAS SUBMITTED | | | FOR AN INSWING DOOR THAT IS NOT A FRENCH | | | DOOR (GLAZED) AS STATED FOR FRONT DOOR | | | ON THE DRAWINGS. PLEASE MAKE CORRECTIONS | | | AND REMOVE PRODUCTS THAT ARE INCORRECT | | | OR NOT USED. SUBMIT REVIEWED AND | | | APPROVED ALTERNATIVES. | | | | | | 6) ALL PERMIT APPLICATION FEES MUST BE | | | PAID BEFORE FURTHER REVIEWS WILL BE MADE | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-17 |
Time |
09:51 |
Rev Time |
3.00 |
| Received By |
amorse |
Date |
2006-07-17 |
Time |
09:51 |
Sent To |
PC |
|
| Notes |
| 2006-07-17 00:00:00 | | | | | | | DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* | | | | | | 3) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE PER 10D-91 FAC | | | | | | 4) IN AREAS OF QUESTIONABLE SOILS AS | | | SHOWN IN THE OFFICIAL ZONING MAP ADOPTED | | | BY THE CITY OF WEST PALM BEACH, A SOIL | | | TEST REPORT SHALL BE SUBMITTED PER | | | R401.4 PLEASE SUBMIT 2 COPIES SIGNED, | | | SEALED AND DATED BY RESPONSIBLE PARTY. | | | PLEASE NOTE THAT DESIGNER OF RECORD | | | SHALL REVIEW AND APPROVE REPORT (COPY OF | | | REPORT SUBMITTED STATES BEARING CAPACITY | | | OF 1500 PSF WHILE DRAWINGS REQUIRE 2000 | | | PSF) | | | | | | 5) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | | APPLICATION OR BEFORE INSTALLATION. 2 | | | COPIES SIGNED, SEALED AND DATED BY | | | RESPONSIBLE PARTY. (PLEASE NOTE DRAWINGS | | | SUBMITTED ARE NOT SEALED BY PERSONS | | | RESPONSIBLE, ALSO DRAWINGS ARE REQUIRED | | | TO BE REVIEWED AND APPROVED BY DESIGNER | | | OF (RECORD) | | | | | | 6) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | ******NOTE THE FOLLOWING PRODUCT | | | APPROVALS ARE REQUIRED********* | | | FRENCH DOORS, GARAGE ENTRY DOOR, LINTELS | | | TRANSOM WINDOWS, MULLIONS, ALSO 3 | | | DIFFERENT NOA'S WERE SUBMITTED FOR GLASS | | | BLOCK AND THE STATE APPROVAL SHEETS WERE | | | NOT (ALL PRODUCT APPROVALS WHERE | | | POSSIBLE SHALL BE SUBMITTED WITH THE | | | STATE COVER SHEETS | | | | | | 7) THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 8) PROVIDE A SITE PLAN THAT SHOWS | | | COMPLIANCE WITH LANDSCAPE REQUIREMENTS | | | AND A DRAINAGE PLAN PER R401.3 FBC | | | | | | 9) PROVIDE LINTEL SCHEDULE WITH SIZES | | | AND LENGTHS TO BE USED | | | | | | 10) SPECIFY SAFETY GLAZING REQUIRED IF | | | GLASS BETWEEN TUB AND SHOWER MEET THE | | | REQUIREMENTS OF R308.1 AND R308.4 FBC | | | | | | 11) VERTICAL REINFORCEMENT MAX 6'-0" O/C | | | A/1 STATES MIN | | | | | | 12) SECTIONS 02/A3 AND 03/A3 SHOW TOP OF | | | BEAM HEIGHT AT 10'-0" ELEVATIONS SHOW | | | 9'-4" PLEASE CLARIFY | | | | | | 13) PROVIDE TRANSOM SIZES AND DESIGN | | | PRESSURES ON THE DOOR AND WINDOW SCEDULE | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-02-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-07 |
Time |
07:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-07 |
Time |
07:24 |
Sent To |
M |
|
| Notes |
| 2007-02-07 07:52:39 | | | | | | | PROVISO | | | | | | SUBMIT A REVISION PRIOR TO FINAL ELECTRICAL INSPECTION, | | | ADDING THE RECIRCULATING PUMP TO THE PANEL SCHEDULE AND | | | LOAD CALCULATIONS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-20 |
Time |
12:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-11-20 |
Time |
11:54 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-13 |
Time |
11:17 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-13 |
Time |
07:57 |
Sent To |
M |
|
| Notes |
| 2006-09-13 00:00:00 | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE A RISER DIAGRAM WITH | | | CONDUCTOR AND CONDUIT SIZE AND TYPE, | | | GROUNDING DETAILS, LOAD CALCULATIONS, | | | PANEL SCHEDULES, SERVICE EQUIPMENT AND | | | PANEL LOCATIONS PER 106.3.5.4 FBC. THIS | | | DOCUMENT MUST BE PRODUCED BY THE | | | DESIGNER OF RECORD FOR THE PROJECT, AND | | | SIGNEDAND SEALED BY SAME. | | | | | | 2} THE RECEPTACLE IN THE MASTER BATH | | | MUST COMPLY WITH 210.52(D), WITHIN 3' OF | | | THE BASIN. PLEASE CORRECT ON PLANS. | | | | | | 3} THE WHITE OUT ON THE PLAN IS NOT | | | ACCEPTABLE FOR RECORD RETENTION PER | | | 106.1.3 FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561) 805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-12 |
Time |
18:19 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-12 |
Time |
18:05 |
Sent To |
M |
|
| Notes |
| 2006-07-12 00:00:00 | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE A RISER DIAGRAM WITH | | | CONDUCTOR AND CONDUIT SIZE AND TYPE, | | | GROUNDING DETAILS, LOAD CALCULATIONS, | | | PANEL SCHEDULES, SERVICE EQUIPMENT AND | | | PANEL LOCATIONS PER 106.3.5.4 FBC. | | | | | | 2} THE RECEPTACLE IN THE MASTER BATH | | | MUST COMPLY WITH 210.52(D), WITHIN 3' OF | | | THE BASIN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561) 805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-10 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-10 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2007-03-10 14:03:45 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-06 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-06 |
Time |
15:08 |
Sent To |
E |
|
| Notes |
| 2007-02-06 15:08:38 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-20 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-20 |
Time |
08:16 |
Sent To |
E |
|
| Notes |
| 2006-11-20 08:17:09 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-05 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-05 |
Time |
09:57 |
Sent To |
E |
|
| Notes |
| 2006-09-05 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-10 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-08 |
Time |
09:39 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-08 |
Time |
09:39 |
Sent To |
P |
|
| Notes |
| 2007-02-08 09:40:29 | REVISION TO MECHANICAL PLANS AND MANUAL J CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-20 |
Time |
14:01 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-20 |
Time |
14:01 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-14 |
Time |
08:57 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-09-14 |
Time |
08:57 |
Sent To |
P |
|
| Notes |
| 2006-09-14 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS SUBMITTED ARE | | | DIFFICULT TO READ, CHANGES MADE BY HAND | | | TO PLANS NEED TO BE INITIALED AND DATED | | | AT EACH CHANGE, RED PEN CAN NOT BE USED | | | FOR CHANGES AS IT FADES IN TIME, | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | | | | 2) PLEASE CORRECT THE ADDRESS ON THE | | | PLANS AND ENERGY CAL'S. 1321 N. MANGONIA | | | DR. WEST PALM BEACH, FL. (NOT PALM | | | BEACH). | | | | | | 3) PLANS NEED THE PRINTED NAME, ADDRESS, | | | AND PHONE NUMBER OF THE DESIGN PERSON OR | | | COMPANY ON THEM. | | | | | | 4) ENERGY CAL'S. NEED THE JURISDICTION | | | NUMBER ON THEM. | | | | | | 5) ENERGY CAL'S. ARE CALLING FOR A/C | | | SYSTEM #1 TO BE 14 SEER, PLANS ARE | | | CALLING FOR A/C SYSTEM #1 TO BE 13 SEER, | | | THE TWO MUST COINCIDE, PLEASE CORRECT. | | | | | | 6) AS NOTED IN LAST REVIEW 7-13-06 NOTE | | | #5, PLEASE SHOW CLOTHES DRYER VENT, AND | | | BATHROOM VENTS ON MECHANICAL PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-13 |
Time |
08:31 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-07-13 |
Time |
08:31 |
Sent To |
B |
|
| Notes |
| 2006-07-13 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS SUBMITTED ARE TO | | | SMALL AND ARE DIFFICULT TO READ, | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | . | | | | | | 2)PLEASE SHOW GRILL SIZES ON MECHANICAL | | | PLANS. | | | | | | 3) CAN NOT READ ALL SUPPLY AIR DUCT | | | SIZES, PLEASE CORRECT. | | | | | | 4) PLEASE SHOW A/C EQUIPMENT LISTING ON | | | MECHANICAL PLANS. | | | | | | 5) PLEASE SHOW CLOTHES DRYER VENT, AND | | | BATHROOM VENTS ON MECHANICAL PLANS. | | | | | | 6) PROVIDE FOR RETURN AIR, SEE NOTE #8. | | | | | | 7) ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 8) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-14 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-14 |
Time |
09:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-20 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-20 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-25 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-09-25 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-25 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2006-09-25 00:00:00 | RE-SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-12 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-12 |
Time |
14:11 |
Sent To |
E |
|
| Notes |
| 2006-07-12 00:00:00 | DENIED; | | | 1.SANITARY RISER DIAGRAM; MASTER | | | BATHROOM LAVS ARE NOT ON THE SAME WALL. | | | A VENT STACK IS NEEDED FOR EACH LAV. | | | 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN | | | IS REQUIRED TO BE 3", FBC-2004 PLUMBING | | | SEC. 406.3. CLEANOUT SHOULD BE LOCATED | | | AT 48" ABOVE FINISHED FLOOR FOR SERVICE. | | | ON SET OF PLANS MARKED IN RED | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-10 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-10 |
Time |
14:41 |
Sent To |
E |
|
| Notes |
| 2006-07-10 00:00:00 | NOTE: | | | THE PROPOSED A/C SHALL NOT BE CLOSER | | | THAN 1FT FROMSIDE PROPERTY LINE. | | | | | | PROVISO: IF ANY CHANGES TO THE SURVEY, | | | PLEASE SHOW THE LOCATION OF THE A/C | | | UNIT. |
|
|