| 2006-07-15 00:00:00 | |
| | DENIED |
| | |
| | 1) AUTHORIZATION LETTER FROM A ENGINEER |
| | SHALL BE SIGNED, SEALED AND DATED |
| | |
| | 2) SITE DRAWING DOES NOT CONTAIN THE |
| | WIND LOAD DESIGN DATA PER 1603.1.4 FBC |
| | |
| | 3) DUE TO THE BOARD OF ENGINEERS RECENT |
| | CONCERNS WITH THE DESIGN OF SCEEN |
| | ENCLOSURES AND THIS PRESCRIPTIVE GUIDE |
| | PLEASE SUBMIT ENGINEERED, SIGNED, SEALED |
| | AND DATED SHEETS FOR THE CONSTRUCTION OF |
| | SCREEN ENCLOSURES. THIS REQUIREMENT IS |
| | PROVIDED FOR UNDER 2002.1 FBC |
| | |
| | 4) THE REVIEW OF PAGES OF INFORMATION |
| | THAT ARE NOT CLEARLY MARKED AS TO THE |
| | STRUCTURAL COMPONENTS BEING USED EXTENDS |
| | REVIEW TIME. ALSO BE AWARE THAT THE AAF |
| | GUIDE WAS NOT CORRECTLY FOLLOWED AS THE |
| | SPAN IN THE SITE SPECIFIC DRAWING IS |
| | GREATER THAN THE CHOSEN MEMBER IS |
| | ALLOWED TO SPAN IN THEGUIDE PAGES |
| | SUBMITTED.(BOTH BEAMS AND COLUMNS) |
| | |
| | 5) SITE DRAWING DOES NOT SPECIFY TYPE OF |
| | 2X9 BEAM THAT IS TO BE USED ALTHOUGH |
| | NEITHER WILL WORK FOR SPECIFIED SPAN |
| | |
| | 6) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO A |
| | PERMIT BEING ISSUED |
| | |