Plan Review Details - Permit 06061582
Plan Review Stops For Permit 06061582
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-03-16 Cont ID  
Sent By lmartine Date 2007-03-16 Time 18:20 Rev Time 0.00
Received By lmartine Date 2007-03-16 Time 18:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2007-02-21 Cont ID  
Sent By lmartine Date 2007-02-21 Time 18:28 Rev Time 0.00
Received By lmartine Date 2007-02-21 Time 18:02 Sent To  
Notes
2007-02-22 11:30:31 
 REVISION #5
  
 SUBMIT REVISED SURVEY FOR NEW CONCRETE DRIVEAND
 EQUIPMENT SLAB IDENTIFYING THEIR SEPARATION FROM
 PROPERTY LINES.
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-02-20 Cont ID  
Sent By rnuquist Date 2007-02-20 Time 19:04 Rev Time 0.00
Received By rnuquist Date 2007-02-20 Time 19:04 Sent To  
Notes
2007-02-21 18:26:24 
 REVSION #5
  
 SUBMIT REVISED SURVEY FORNEW CONCRETE DRIVE AND
 EQUIPMENT SLAB IDENTIFYING THEIR SEPARATIONS FROM
 PROPERTY LINES.
  
  
  
  
 L.MARTINEZ
 805-6710

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-11-20 Cont ID  
Sent By alange Date 2006-11-20 Time 11:08 Rev Time 0.00
Received By alange Date 2006-11-20 Time 11:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-09-27 Cont ID  
Sent By alange Date 2006-09-27 Time 13:19 Rev Time 1.00
Received By alange Date 2006-09-27 Time 13:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-25 Cont ID  
Sent By alange Date 2006-09-25 Time 11:43 Rev Time 1.00
Received By alange Date 2006-09-25 Time 11:43 Sent To  
Notes
2006-09-25 00:00:00DENIED
  
  
 4.PRODUCT APPROVALS REQUIRED FOR
 HARDIEPLANK SIDING.
  
 8.PLANS SPECIFY CGI WINDOWS YET PGT
 PRODUCT APPROVALS WERE SUBMITTED. PLEASE
 CLARIFY.SEE A/O SCOPE OF WORK.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-27 Cont ID  
Sent By alange Date 2006-07-27 Time 08:34 Rev Time 2.00
Received By alange Date 2006-07-27 Time 08:34 Sent To  
Notes
2006-07-27 00:00:00DENIED
  
  
 1.WIND LOADS SHALL BE DESIGNED TO ASCE
 7-02.
  
 2. INCORRECT CONSTRUCTION TYPE
 MENTIONED.SEE CHAPTER 6 2004 FBC
  
 3.COMPLETE TOP SECTION OF ENERGY CALCS
 PER 2004 FBC.
  
 4.PRODUCT APPROVALS REQUIRED FOR
 LINTELS, HARDIEPLANK SIDING, OVERHEAD
 DOOR.
  
 5.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
 TRUSS DRAWING REQUIRED TO BE APPROVED
 PRIOR TO INSTALLATION.
  
 6.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 7.R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A
 STORM SEWER CONVEYANCE OR OTHER APPROVED
 POINT OF COLLECTION SO AS TO NOT CREATE
 A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION
 WALLS. THE GRADE AWAY FROM FOUNDATION
 WALLS SHALL FALL A MINIMUM OF 6 INCHES
 WITHIN THE FIRST 10 FEET.
  
 8.PLANS SPECIFY CGI WINDOWS YET PGT
 PRODUCT APPROVALS WERE SUBMITTED. PLEASE
 CLARIFY.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-03-12 Cont ID  
Sent By btrobaug Date 2007-03-12 Time 16:37 Rev Time 0.50
Received By btrobaug Date 2007-03-12 Time 15:25 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-22 Cont ID  
Sent By btrobaug Date 2006-12-22 Time 11:30 Rev Time 0.50
Received By btrobaug Date   Time   Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-09-06 Cont ID  
Sent By btrobaug Date 2006-09-06 Time 17:14 Rev Time 0.50
Received By btrobaug Date 2006-09-06 Time 15:46 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-13 Cont ID  
Sent By btrobaug Date 2006-07-13 Time 17:53 Rev Time 1.00
Received By btrobaug Date 2006-07-13 Time 15:45 Sent To P
Notes
2006-07-13 00:00:00 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE 2/0 FEEDERS FROM THE METER TO THE
 GUTTER ARE NOTLARGE ENOUGH FOR THE LOAD
 SERVED. THE FEED WOULD BE OK IF
 PARALLELED.
  
 2} THE GENERATOR AND TRANSFER SWITCH
 MUST BE PERMITTED SEPARATELY. THE
 CONFIGURATION IS TENETAVELY OK.
  
 3} THE NEUTRAL IS NOT ISOLATED FROM THE
 GROUND UNTILL THE FIRST MEANS OF
 DISCONNECT TO PREVENT PARALLELING GROUND
 AND RETURN PATHS, THEREFORE THE GROUND
 WIRE SHOULD NOT BE RUN WITH THE SERVICE
 CONDUCTORS FROM THE METER. 250.4(A)(5).
  
 4} PANEL "A" DOES NOT SHOW THE DEMAND
 LOADS, CANNOT VERIFY OCP AN DWIRE
 SIZE.310.16, 240.4.
  
 5} AHU #3 INDICATES #14 WIRE ON A 15 AMP
 BREAKER. PLEASE CHECK THE DEMAND AND
 SHOW SAME. ALSO CHECK A/C #3.
  
 6} THE RISER INDICATES THE SERVICE
 ATTACHED WITH A GUTTER. THE PLANS SHOW
 THE ATS AND METER OUTSIDE, AND THE
 PANELS INSIDE, PLEASE CLARIFY.
  
 7} THE WHIRLPOOL IN THE MASTER BATH IS
 NOT IN THE CALCS.
  
 8} INDICATE THE ROOM DESIGNATIONS ON THE
 ELECTRICAL PLAN. SHEET E-1 AND A-1 ARE
 NOT THE SAME FLOOR PLAN.
  
 THERE WILL BE NO FURTHER ELECTRICAL
 REVIEW UNTILL ITEM #8 IS CORRECTED.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561) 805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-04-09 Cont ID  
Sent By adarroug Date 2007-04-09 Time 16:20 Rev Time 0.00
Received By adarroug Date 2007-04-09 Time 16:20 Sent To B
Notes
2007-04-09 16:21:13TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-03-09 Cont ID  
Sent By adarroug Date 2007-03-09 Time 16:41 Rev Time 0.00
Received By adarroug Date 2007-03-09 Time 16:41 Sent To E
Notes
2007-03-09 16:41:55TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-03-01 Cont ID  
Sent By adarroug Date 2007-03-01 Time 13:21 Rev Time 0.00
Received By adarroug Date 2007-03-01 Time 13:21 Sent To B
Notes
2007-03-01 13:22:29TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-02-09 Cont ID  
Sent By adarroug Date 2007-02-09 Time 16:07 Rev Time 0.00
Received By adarroug Date 2007-02-09 Time 16:07 Sent To M
Notes
2007-02-09 16:07:35TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-02-02 Cont ID  
Sent By adarroug Date 2007-02-02 Time 11:36 Rev Time 0.00
Received By adarroug Date 2007-02-02 Time 11:36 Sent To M
Notes
2007-02-02 11:37:14TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-01-10 Cont ID  
Sent By adarroug Date 2007-01-10 Time 08:24 Rev Time 0.00
Received By adarroug Date 2007-01-10 Time 08:24 Sent To B
Notes
2007-01-10 08:24:55TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-12-15 Cont ID  
Sent By adarroug Date 2006-12-15 Time 15:20 Rev Time 0.00
Received By adarroug Date 2006-12-15 Time 15:20 Sent To E
Notes
2006-12-15 15:21:03TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-17 Cont ID  
Sent By adarroug Date 2006-11-17 Time 14:14 Rev Time 0.00
Received By adarroug Date 2006-11-17 Time 14:14 Sent To B
Notes
2006-11-17 14:14:54TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-31 Cont ID  
Sent By adarroug Date 2006-08-31 Time 16:21 Rev Time 0.00
Received By adarroug Date 2006-08-31 Time 16:21 Sent To E
Notes
2006-08-31 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-19 Cont ID  
Sent By adarroug Date 2006-08-19 Time 16:00 Rev Time 0.00
Received By adarroug Date 2006-08-19 Time 16:00 Sent To Z
Notes
2006-08-19 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-08 Cont ID  
Sent By adarroug Date 2006-07-08 Time 15:56 Rev Time 0.00
Received By adarroug Date 2006-07-08 Time 15:56 Sent To E
Notes
2006-07-08 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-27 Cont ID  
Sent By alange Date 2006-07-27 Time 08:35 Rev Time 0.00
Received By alange Date 2006-06-29 Time 13:41 Sent To  
Notes
2006-06-29 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-02-12 Cont ID  
Sent By tgordon Date 2007-02-12 Time 12:00 Rev Time 0.30
Received By tgordon Date 2007-02-12 Time 12:00 Sent To  
Notes
2007-02-12 12:01:25REVISION TO MECH. PLAN AND COOLING LOAD CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-02-02 Cont ID  
Sent By tgordon Date 2007-02-02 Time 14:23 Rev Time 0.45
Received By tgordon Date 2007-02-02 Time 14:23 Sent To  
Notes
2007-02-02 14:33:53MECHANICAL REVISION
 *** DENIED ***
 1) COOLING LOAD CALCULATIONS ON FILE ARE CALLING FOR
 UNIT #1 31,100 SENSIBLE BTU'S, AND UNIT #2 32,200
 SENSIBLE BTU'S, REVISED PLANS ARE SHOWING 27,000
 SENSIBLE BTU'S. THE PLANS MAY NOT CALL FOR LESS THAN
 THE COOLING LOAD CALCULATIONS, PER 2004 FBC
 13-607.1.ABC.1.1. YOU NEED TO REVISE THE COOLING LOAD
 CALCULATIONS OR THE EQUIPMENT LISTING ON THE PLANS.
  
 2) REVISED PLANS ARE CALLING FOR 1" THICK INSELATION
 DUCTS (R-4). ALL A/C DUCT WORK NOT IN CONDITIONED
 SPACES MUST BE R-6 (1.5" THICK INSULATION, PER 2004 FBC
 13-610.1.B.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-09-15 Cont ID  
Sent By tgordon Date 2006-09-15 Time 08:23 Rev Time 0.20
Received By tgordon Date 2006-09-15 Time 08:23 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-09-07 Cont ID  
Sent By tgordon Date 2006-09-07 Time 11:16 Rev Time 0.30
Received By tgordon Date 2006-09-07 Time 11:16 Sent To P
Notes
2006-09-07 00:00:00*** DENIED ***
 1) LOAD CALCULATIONS ARE FOR COMMERCIAL
 APPLICATION, PLEASE SUBMIT RESIDENTIAL
 CALCULATIONS (MANUAL J OR OTHER APPROVED
 CAL'S.) PER 2004 FBC/R M1401.3 .
  
 2) IF REQUIRED AS A RESULT OF THE
 RESIDENTIAL CAL'S. PLEASE MAKE
 CORRECTIONS TO THE MECHANICAL PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-07-17 Cont ID  
Sent By tgordon Date 2006-07-17 Time 11:11 Rev Time 0.45
Received By tgordon Date 2006-07-17 Time 11:11 Sent To B
Notes
2006-07-17 00:00:00*** DENIED ***
 1) RETURN AIR TRANSFER DUCTS TO BEDROOM
 #1 AND #3 ARE TO SMALL, SEE NOTE #6(A).
  
 2) NEED TO PROVIDE RETURN AIR FOR
 BEDROOM #2 AND STUDY, SEE NOTE #6.
  
 3) SHOW ON PLANS IF CLOTHES DRYER IS GAS
 OR ELECTRIC.
  
 4) IF CLOTHES DRYER IS GAS PROVIDE
 COMBUSTION AIR, PER 2004 FBC/R M1701.1 .
  
 5) CLOTHES DRYER VENT TERMINATION MUST
 BE A MIN. OF 4 FT. FROM A/C CONDENSER
 UNIT, PER 2004 FBC/M 501.2 .
  
 6) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-09-19 Cont ID  
Sent By jleech Date 2006-09-19 Time 07:16 Rev Time 0.00
Received By jleech Date 2006-09-19 Time 07:16 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-17 Cont ID  
Sent By jleech Date 2006-07-17 Time 10:20 Rev Time 0.00
Received By jleech Date 2006-07-17 Time 10:20 Sent To M
Notes
2006-07-17 00:00:00DENIED;
 1.SANITARY RISER DIAGRAM IS REQUIRED FBC
 CHAPTER 1 SECTION 106.3.5.4(9).
 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN
 IS REQUIRED TO BE 3" PLUMBING SECTION
 406.3.
 3.BATHROOM #2 MAX. OF 10' FROM THE BREAK
 OF THE VENT TO THE TOILET. SEC. 906.1.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop REV REVISIONS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By rmcdouga Date 2007-01-02 Time 10:45 Sent To  
Notes
2007-01-02 10:46:46REVISED METAL ROOF PRODUCT APPROVAL AND CHANGED ROOFING
 SUBCONTRACTOR

Review Stop Z ZONING
Rev No 2 Status P Date 2006-08-25 Cont ID  
Sent By mmclean Date 2006-08-25 Time 18:25 Rev Time 0.00
Received By mmclean Date 2006-08-25 Time 18:25 Sent To I
Notes
2006-08-25 00:00:00NOTE:THE PROPOSED A/C EQUIPMENT SHALL
 NOT BE CLOSER THAN 8.5FT FROM SIDE
 PROPERTY LINE. THE A/C UNIT MUST BE
 SCREENED WITH LANDSCAPE.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 THE PROPOSED GENERATOR.
  
 NOTE: MUST PULL A SPERATE PERMIT FOR THE
 NEW SITE WALLS W/WOOD GATES AND NEW
 ELECTRICAL GATE WITH EASEMENT APPROVAL
 FROM THE CITY OF WEST PALM BEACH
 UTILITIY DEPT AND SITE WALL DETAIL PLAN.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-07-07 Cont ID  
Sent By mmclean Date 2006-07-07 Time 07:54 Rev Time 0.00
Received By mmclean Date 2006-07-07 Time 07:54 Sent To I
Notes
2006-07-07 00:00:00NOTE: MUST PULL A SEPERATE PERMIT FOR
 SITE WALL/GATE WITH EASEMENT APPROVAL
 FROM THE CITY OF WEST PALM BEACH UTILITY
 DEPT.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 POOL/DECK.
  
 DENIED,
 1. PLEASE PROVIDE THE REAR SETBACK OF
 THE PROPOSED ADDITION ON THE NE CORNER
 OF PROPERTY.
 2. PLEASE SHOW THE LOCATION OF THE
 GENERATOR AND A/C UNIT ON THE TWO COPY
 OF SURVEYS AND SITEPLANS
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  


Account Summary | Usage Policy | Privacy Policy