| Plan Review Stops For Permit 06061582 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-16 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-16 |
Time |
18:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-02-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-02-21 |
Time |
18:28 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-02-21 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2007-02-22 11:30:31 | | | | REVISION #5 | | | | | | SUBMIT REVISED SURVEY FOR NEW CONCRETE DRIVEAND | | | EQUIPMENT SLAB IDENTIFYING THEIR SEPARATION FROM | | | PROPERTY LINES. | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2007-02-20 |
Time |
19:04 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2007-02-20 |
Time |
19:04 |
Sent To |
|
|
| Notes |
| 2007-02-21 18:26:24 | | | | REVSION #5 | | | | | | SUBMIT REVISED SURVEY FORNEW CONCRETE DRIVE AND | | | EQUIPMENT SLAB IDENTIFYING THEIR SEPARATIONS FROM | | | PROPERTY LINES. | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-11-20 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-11-20 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-27 |
Time |
13:19 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-09-27 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-25 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-25 |
Time |
11:43 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-09-25 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2006-09-25 00:00:00 | DENIED | | | | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | | HARDIEPLANK SIDING. | | | | | | 8.PLANS SPECIFY CGI WINDOWS YET PGT | | | PRODUCT APPROVALS WERE SUBMITTED. PLEASE | | | CLARIFY.SEE A/O SCOPE OF WORK. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-27 |
Time |
08:34 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-07-27 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2006-07-27 00:00:00 | DENIED | | | | | | | | | 1.WIND LOADS SHALL BE DESIGNED TO ASCE | | | 7-02. | | | | | | 2. INCORRECT CONSTRUCTION TYPE | | | MENTIONED.SEE CHAPTER 6 2004 FBC | | | | | | 3.COMPLETE TOP SECTION OF ENERGY CALCS | | | PER 2004 FBC. | | | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | | LINTELS, HARDIEPLANK SIDING, OVERHEAD | | | DOOR. | | | | | | 5.SUBMIT TWO SETS OF TRUSS DRAWINGS | | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | TRUSS DRAWING REQUIRED TO BE APPROVED | | | PRIOR TO INSTALLATION. | | | | | | 6.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | 7.R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | | POINT OF COLLECTION SO AS TO NOT CREATE | | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | | WALLS. THE GRADE AWAY FROM FOUNDATION | | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | | WITHIN THE FIRST 10 FEET. | | | | | | 8.PLANS SPECIFY CGI WINDOWS YET PGT | | | PRODUCT APPROVALS WERE SUBMITTED. PLEASE | | | CLARIFY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-12 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-12 |
Time |
15:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-22 |
Time |
11:30 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-06 |
Time |
17:14 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-06 |
Time |
15:46 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-13 |
Time |
17:53 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-07-13 |
Time |
15:45 |
Sent To |
P |
|
| Notes |
| 2006-07-13 00:00:00 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE 2/0 FEEDERS FROM THE METER TO THE | | | GUTTER ARE NOTLARGE ENOUGH FOR THE LOAD | | | SERVED. THE FEED WOULD BE OK IF | | | PARALLELED. | | | | | | 2} THE GENERATOR AND TRANSFER SWITCH | | | MUST BE PERMITTED SEPARATELY. THE | | | CONFIGURATION IS TENETAVELY OK. | | | | | | 3} THE NEUTRAL IS NOT ISOLATED FROM THE | | | GROUND UNTILL THE FIRST MEANS OF | | | DISCONNECT TO PREVENT PARALLELING GROUND | | | AND RETURN PATHS, THEREFORE THE GROUND | | | WIRE SHOULD NOT BE RUN WITH THE SERVICE | | | CONDUCTORS FROM THE METER. 250.4(A)(5). | | | | | | 4} PANEL "A" DOES NOT SHOW THE DEMAND | | | LOADS, CANNOT VERIFY OCP AN DWIRE | | | SIZE.310.16, 240.4. | | | | | | 5} AHU #3 INDICATES #14 WIRE ON A 15 AMP | | | BREAKER. PLEASE CHECK THE DEMAND AND | | | SHOW SAME. ALSO CHECK A/C #3. | | | | | | 6} THE RISER INDICATES THE SERVICE | | | ATTACHED WITH A GUTTER. THE PLANS SHOW | | | THE ATS AND METER OUTSIDE, AND THE | | | PANELS INSIDE, PLEASE CLARIFY. | | | | | | 7} THE WHIRLPOOL IN THE MASTER BATH IS | | | NOT IN THE CALCS. | | | | | | 8} INDICATE THE ROOM DESIGNATIONS ON THE | | | ELECTRICAL PLAN. SHEET E-1 AND A-1 ARE | | | NOT THE SAME FLOOR PLAN. | | | | | | THERE WILL BE NO FURTHER ELECTRICAL | | | REVIEW UNTILL ITEM #8 IS CORRECTED. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561) 805-6718 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-09 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-09 |
Time |
16:20 |
Sent To |
B |
|
| Notes |
| 2007-04-09 16:21:13 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-09 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-09 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
| 2007-03-09 16:41:55 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
13:21 |
Sent To |
B |
|
| Notes |
| 2007-03-01 13:22:29 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-09 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-09 |
Time |
16:07 |
Sent To |
M |
|
| Notes |
| 2007-02-09 16:07:35 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-02 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-02 |
Time |
11:36 |
Sent To |
M |
|
| Notes |
| 2007-02-02 11:37:14 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-10 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-10 |
Time |
08:24 |
Sent To |
B |
|
| Notes |
| 2007-01-10 08:24:55 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-15 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-15 |
Time |
15:20 |
Sent To |
E |
|
| Notes |
| 2006-12-15 15:21:03 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-17 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-17 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2006-11-17 14:14:54 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-31 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-31 |
Time |
16:21 |
Sent To |
E |
|
| Notes |
| 2006-08-31 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-19 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-19 |
Time |
16:00 |
Sent To |
Z |
|
| Notes |
| 2006-08-19 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-08 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-08 |
Time |
15:56 |
Sent To |
E |
|
| Notes |
| 2006-07-08 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-27 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-29 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-12 |
Time |
12:00 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-12 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2007-02-12 12:01:25 | REVISION TO MECH. PLAN AND COOLING LOAD CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-02-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-02 |
Time |
14:23 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-02-02 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2007-02-02 14:33:53 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) COOLING LOAD CALCULATIONS ON FILE ARE CALLING FOR | | | UNIT #1 31,100 SENSIBLE BTU'S, AND UNIT #2 32,200 | | | SENSIBLE BTU'S, REVISED PLANS ARE SHOWING 27,000 | | | SENSIBLE BTU'S. THE PLANS MAY NOT CALL FOR LESS THAN | | | THE COOLING LOAD CALCULATIONS, PER 2004 FBC | | | 13-607.1.ABC.1.1. YOU NEED TO REVISE THE COOLING LOAD | | | CALCULATIONS OR THE EQUIPMENT LISTING ON THE PLANS. | | | | | | 2) REVISED PLANS ARE CALLING FOR 1" THICK INSELATION | | | DUCTS (R-4). ALL A/C DUCT WORK NOT IN CONDITIONED | | | SPACES MUST BE R-6 (1.5" THICK INSULATION, PER 2004 FBC | | | 13-610.1.B.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-15 |
Time |
08:23 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-09-15 |
Time |
08:23 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-07 |
Time |
11:16 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-07 |
Time |
11:16 |
Sent To |
P |
|
| Notes |
| 2006-09-07 00:00:00 | *** DENIED *** | | | 1) LOAD CALCULATIONS ARE FOR COMMERCIAL | | | APPLICATION, PLEASE SUBMIT RESIDENTIAL | | | CALCULATIONS (MANUAL J OR OTHER APPROVED | | | CAL'S.) PER 2004 FBC/R M1401.3 . | | | | | | 2) IF REQUIRED AS A RESULT OF THE | | | RESIDENTIAL CAL'S. PLEASE MAKE | | | CORRECTIONS TO THE MECHANICAL PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-17 |
Time |
11:11 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-07-17 |
Time |
11:11 |
Sent To |
B |
|
| Notes |
| 2006-07-17 00:00:00 | *** DENIED *** | | | 1) RETURN AIR TRANSFER DUCTS TO BEDROOM | | | #1 AND #3 ARE TO SMALL, SEE NOTE #6(A). | | | | | | 2) NEED TO PROVIDE RETURN AIR FOR | | | BEDROOM #2 AND STUDY, SEE NOTE #6. | | | | | | 3) SHOW ON PLANS IF CLOTHES DRYER IS GAS | | | OR ELECTRIC. | | | | | | 4) IF CLOTHES DRYER IS GAS PROVIDE | | | COMBUSTION AIR, PER 2004 FBC/R M1701.1 . | | | | | | 5) CLOTHES DRYER VENT TERMINATION MUST | | | BE A MIN. OF 4 FT. FROM A/C CONDENSER | | | UNIT, PER 2004 FBC/M 501.2 . | | | | | | 6) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-19 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-19 |
Time |
07:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-17 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-17 |
Time |
10:20 |
Sent To |
M |
|
| Notes |
| 2006-07-17 00:00:00 | DENIED; | | | 1.SANITARY RISER DIAGRAM IS REQUIRED FBC | | | CHAPTER 1 SECTION 106.3.5.4(9). | | | 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN | | | IS REQUIRED TO BE 3" PLUMBING SECTION | | | 406.3. | | | 3.BATHROOM #2 MAX. OF 10' FROM THE BREAK | | | OF THE VENT TO THE TOILET. SEC. 906.1. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
REV |
REVISIONS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-01-02 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2007-01-02 10:46:46 | REVISED METAL ROOF PRODUCT APPROVAL AND CHANGED ROOFING | | | SUBCONTRACTOR |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-25 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-25 |
Time |
18:25 |
Sent To |
I |
|
| Notes |
| 2006-08-25 00:00:00 | NOTE:THE PROPOSED A/C EQUIPMENT SHALL | | | NOT BE CLOSER THAN 8.5FT FROM SIDE | | | PROPERTY LINE. THE A/C UNIT MUST BE | | | SCREENED WITH LANDSCAPE. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | THE PROPOSED GENERATOR. | | | | | | NOTE: MUST PULL A SPERATE PERMIT FOR THE | | | NEW SITE WALLS W/WOOD GATES AND NEW | | | ELECTRICAL GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM BEACH | | | UTILITIY DEPT AND SITE WALL DETAIL PLAN. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-07 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-07 |
Time |
07:54 |
Sent To |
I |
|
| Notes |
| 2006-07-07 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | SITE WALL/GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM BEACH UTILITY | | | DEPT. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK. | | | | | | DENIED, | | | 1. PLEASE PROVIDE THE REAR SETBACK OF | | | THE PROPOSED ADDITION ON THE NE CORNER | | | OF PROPERTY. | | | 2. PLEASE SHOW THE LOCATION OF THE | | | GENERATOR AND A/C UNIT ON THE TWO COPY | | | OF SURVEYS AND SITEPLANS | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|