| Plan Review Stops For Permit 06061475 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-07-18 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-06-27 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | EXT #0001 IS ADDED FOR THE UNIT 2114 FOR | | | THE SECOND FLOOR UNDER THE MAIN ADDRESS | | | 901 S FLAGLER DR,PCN = | | | 74434327350000010. | | 2006-06-27 00:00:00 | ADDRESS ON APP READS 901 S FLAGLER | | | DR/2ND FLOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-12-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-13 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-13 |
Time |
09:55 |
Sent To |
PC |
|
| Notes |
| 2006-12-13 15:13:18 | PROVISOR. | | | | | | NEC 2002: ARTICLE 645.2 #5THE WALL AND FLOORS OF THE | | | INFORMATION TECHNOLOGY EQUIPMENT ROOM SHALL HAVE A FIRE | | | RATING NOT LESS THAN 1 HOUR. SEE NFPA 75:5.1.3 FOR MORE | | | INFORMATION.THE EXISTING WALLS SHALL MEETS THIS | | | REQUIREMENT AS WELL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-09-18 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-09-18 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2006-09-18 00:00:00 | | | | 1) THE PRINTED NAME OF THE PERSON | | | SEALING THE DRAWINGS SHALL BE ON EACH | | | SHEET WHICH IS SEALED BY THAT PERSON. | | | SEE SHEETS D-1 - A-2. | | | | | | 2) NFPA 75. 5.1.3. | | | THE INFORMATION TECHNOLOGY EQUIPEMENT | | | ROOM SHALL BE SEPERATED FROM OTHER | | | OCCUPANCIES IN THE INFORMATION | | | TECHNOLOGY EQUIPMENT AREA BY A FIRE | | | RESISTANCE RATING NOT LESS THAN 1 HOUR. | | | | | | 3) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-07-19 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-07-18 |
Time |
09:01 |
Sent To |
M |
|
| Notes |
| 2006-07-18 00:00:00 | 1) ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1,2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 2) 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED | | | BY THE BUILDING OFFICIAL. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE BUILDING OFFICIAL | | | (SEE ALSO SECTION 106.3.5 ). | | | | | | 3) 1509.7 MECHANICAL UNITS. | | | ROOF MOUNTED MECHANICAL UNITS SHALL BE | | | MOUNTED ON CURBS RAISED A MINIMUM OF 8 | | | INCHES (203 MM) ABOVE THE ROOF SURFACE, | | | OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARANCE | | | HEIGHT IN ACCORDANCE WITH ("TABLE | | | 1509.7".) | | | | | | 4) THE ROOF PIPING SUPPORT DETAIL ON | | | SHEE M-3 DOES NOT CORRESPOND WITH THE | | | DETAIL ON SHEET A-2. ALSO ON SHEET M-3, | | | WHERE IS THE GALVANIZED TROUGH DETAIL? | | | NOTE: THE DETAIL SHOWN FOR THE ROOF | | | PIPING PENETRATIONS HAS THE POTENTIAL | | | FOR WATER INTRUSION IN THE FUTURE. | | | | | | 5) INDICATE THE SLOPE OF THE ROOF | | | STRUCTURE WHERE THE MECHINICAL SUPPORTS | | | WILL BE INSTALLED. IF THE ROOD IS | | | SLOPED, SHOW THE ELEVATIONS OF THE | | | MECHNICAL SUPPORTS. | | | | | | 6) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | | | | MYRON JACOBS | | | BUILDING PLANS EXAMINER | | | TEL:(561) 805-6726 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-08 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-08 |
Time |
16:55 |
Sent To |
PC |
|
| Notes |
| 2007-05-08 17:12:34 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE REVIEW NOTES FROM PREVIOUS REVIEW | | | AND NOTES AS REDLINED ON PROVISO AS NOTED ON PLANS | | | ISSUED FOR PERMIT. | | | PLEASE SEE THE TEXT BELOW WHICH WAS SENT TO THE | | | ENGINEER VIA E-MAIL. | | | | | | | | | | | | MR. STEWART, | | | | | | UPON REVIEWING THE LOCATIONS OF THE TWO DISCONNECTS ON | | | PLANS. THE LOCATIONS ARE TOO FAR APART AND CAN NOT BE | | | ACCEPTED. | | | PLEASE SEETHAT A DISCONNECT WOULD BE REQUIRED AT A | | | LOCATION CLOSER AND IN CLOSE PROXIMITY OF THE EXISTING | | | DISCONNECT FOR THIS BUILDING. THIS IS WHAT WAS REDLINED | | | AS A "PROVISO" ON ORIGINAL PLANS. WHEN WE SPOKE ON THE | | | PHONE I DID NOT HAVE THE PLANS, AND CAN NOW SEE HOW FAR | | | THESE DISCONNECTS ACTUALLY ARE. MY DECISIONS IS THE | | | SAME AS ON ORIGINAL REDLINED PLANS AND REVIEW UNDER THE | | | PERMIT THAT THESE ARE TOO FAR APART. | | | I CAN NOT ACCEPT THE SIGNAGE IN LIEU OF GROUPING THE | | | DISCONNECTS FOR THIS BUILDING. | | | MY NOTES AS STATED PREVIOUSLY WITH RESPECT TO MEETING | | | EXCEPTION STILL WOULD STAND IF THAT METHOD/OPTION IT | | | TAKEN. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-04-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-08 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-08 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2007-04-08 10:10:06 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE THAT NOT ALL SHEETS ARE SIGNED, | | | DATED AND SEALED BY THE ENGINEER OF RECORD. | | | FS 471.025, FAC 61G15-23.002 | | | | | | 2) NOTE: PLEASE SEE THE PLANS WERE ISSUED FOR PERMIT | | | WITH *NOTES REDLINED* AND ATTACHED TO PLANS. PLEASE SEE | | | TO DATE THAT NO DOCUMENTATION AHS BEEN VERIFIED FOR | | | COMPLIANCE TO MEET THE EXCEPTIONS OF THE NEC FOR | | | DISCONNECTING MEANS ETC AS PREVIOUSLY GONE OVER FOR THE | | | DETACHED BUILDING. | | | PLEASE SEE 225.31-225.398 | | | PLEASE SEE THE NOTES BELOW ARE TAKEN FROM THE ISSUED | | | PLANS AND PERMITS FOR SCOPE OF WORK. | | | PLEASE PROVIDE COMPLETED DOCUMENTATION FOR EXCEPTION OF | | | *SAFE PROCEDURES*, *QUALIFIED PERSONNEL* ON-SITE 24/7 | | | ETC, PAPERWORK AND DOCUMENTATION MUST BE ORIGINAL, | | | SIGNED, AND NOTARIZED. | | | IF THIS IS NOT MET THEN PLANS AS ORIGINALLY NOTED WILL | | | NEED TO BE REVISED TO MEET NEC CODE COMPLIANCE. | | | | | | 3) NOTE: PLEASE ALSO SEE THAT AS TO DATE OUR RECORDS DO | | | NOT INDICATE ANY LOW VOLTAGE PERMIT WHICH HAS BEEN | | | APPLIED FOR OR ISSUED FOR THIS PROJECT. | | | PLEASE SEE NOTES REDLINED ON PLANS WHICH MENTION THIS | | | IS TO BE UNDER A SEPARATE PERMIT. | | | | | | | | | | | | ************** NOTES REDLINED******* | | | | | | *** LOW VOLTAGE WIRING UNDER A SEPARATE PERMIT. | | | | | | | | | **** 1) NOTE: PLEASE KNOW UPON READING RESPONSE FROM | | | DESIGN TEAM, THIS OFFICE IS WELL AWARE THAT THE | | | STRUCTURE MAY BE FED WITH OTHER SYSTEMS AS LISTED IN | | | 225.30.PLEASE SEE PREVIOUS NOTES WHICH WAS WITH | | | RESPECT TO DISCONNECTING MEANS REQUIRED ETC. PLEASE SEE | | | THE FOLLOWING EXCEPTION WHICH IS TAKEN DIRECTLY FROM | | | THE NEC WILL BE REQUIRED TO BE VERIFIED ON SITE.THIS | | | WAS RED-LINED ON E-5. | | | "EXCEPTION NO. 1: FOR INSTALLATIONS UNDER SINGLE | | | MANAGEMENT, WHERE DOCUMENTED SAFE SWITCHING PROCEDURES | | | ARE ESTABLISHED AND MAINTAINED FOR DISCONNECTION, AND | | | WHERE THE INSTALLATION IS MONITORED BY "QUALIFIED | | | INDIVIDUALS", THE DISCONNECTING MEANS SHALL BE | | | PERMITTED TO BE LOCATED ELSEWHERE ON THE PREMISES " | | | | | | ** PLEASE SEE NEC ART: 100 FOR*QUALIFIED PERSON*. ONE | | | WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE | | | CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT | | | AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING ON | | | THE HAZARDS INVOLVED. | | | EXCERPT FROM HANDBOOK: | | | "NEW IN THE 2002 EDITION, THE DEFINITION OF THE TERM | | | QUALIFIED PERSON NOW INCLUDES SAFETY TRAINING. NO | | | LONGER IS IT ADEQUATE FOR AN ELECTRICAL WORKER TO BE | | | *FAMILIAR WITH THE HAZARDS INVOLVED*; THE ELECTRICAL | | | WORKER OF TODAY MUST ALSO HAVE SAFETY TRAINING ON THE | | | HAZARDS INVOLVED. " | | | | | | ** PLEASE KNOW THESE QUALIFIED PERSON(S) SHALL BE | | | VERIFIED EMPLOYED BY AND ON SITE 24/7, IF THIS CAN NOT | | | BE VERIFIED, ELECTRICAL INSTALLATION AS SHOWN MAY NEED | | | TO BE ADJUSTED TO MEET CODE. | | | THIS PLANS EXAMINER CAN NOT VERIFY AND WILL BE THE | | | RESPONSIBILITY OF THE ENGINEERING / DESIGN TEAM, | | | LICENSED ELECTRICAL CONTRACTOR AND ELECTRICAL | | | INSPECTOR. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-03 |
Time |
20:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-03 |
Time |
20:04 |
Sent To |
|
|
| Notes |
| 2006-11-03 20:47:30 | ************** NOTES REDLINED******* | | | | | | *** LOW VOLTAGE WIRING UNDER A SEPARATE PERMIT. | | | | | | | | | **** 1) NOTE: PLEASE KNOW UPON READING RESPONSE FROM | | | DESIGN TEAM, THIS OFFICE IS WELL AWARE THAT THE | | | STRUCTURE MAY BE FED WITHOTHER SYSTEMS AS LISTED IN | | | 225.30.PLEASE SEE PREVIOUS NOTES WHICH WAS WITH | | | REPSECT TO DISCONNECTING MEANS REQUIRED ETC. PLEASE SEE | | | THE FOLLOWING EXCEPTION WHICH IS TAKEN DIRECTLY FROM | | | THE NEC WILL BE REQUIRED TO BE VERIFIED ON SITE.THIS | | | WAS RED-LINED ON E-5. | | | "EXCEPTION NO. 1: FOR INSTALLATIONS UNDER SINGLE | | | MANAGEMENT, WHERE DOCUMENTED SAFE SWITCHING PROCEDURES | | | ARE ESTABLISHED AND MAINTAINED FOR DISCONNECTION, AND | | | WHERE THE INSTALLATION IS MONITORED BY "QUALIFIED | | | INDIVIDUALS", THE DISCONNECTING MEANS SHALL BE | | | PERMITTED TO BE LOCATED ELSEWHERE ON THE PREMISES " | | | | | | ** PLEASE SEE NECART: 100 FOR "QUALIFIED PERSON". | | | "QUALIFIED PERSON. ONE WHO HAS SKILLS AND KNOWLEDGE | | | RELATED TO THE CONSTRUCTION AND OPERATION OF THE | | | ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED | | | SAFETY TRAINING ON THE HAZARDS INVOLVED. | | | EXCERPT FROM HANDBOOK: | | | "NEW IN THE 2002 EDITION, THE DEFINITION OF THE TERM | | | QUALIFIED PERSON NOW INCLUDES SAFETY TRAINING. NO | | | LONGER IS IT ADEQUATE FOR AN ELECTRICAL WORKER TO BE | | | ?FAMILIAR WITH THE HAZARDS INVOLVED?; THE ELECTRICAL | | | WORKER OF TODAY MUST ALSO HAVE SAFETY TRAINING ON THE | | | HAZARDS INVOLVED. " | | | | | | ** PLEASE KNOW THESE QUALIFIED PERSON(S) SHALL BE | | | VERIFIED EMPLOYED BY AND ON SITE 24/7, IF THIS CAN NOT | | | BE VERIFIED , ELECTRICAL INSTALLATION AS SHOWN MAY NEED | | | TO BE ADJUSTED TO MEET CODE. | | | THIS PLANS EXAMINER CAN NOT VERIFY AND WILL BE THE | | | RESPONSIBILTY OF THE ENGINEERING / DESIGN TEAM, | | | LICENSED ELECTRICAL CONTRACTOR AND ELECTRICAL | | | INSPECTOR. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL., TO DATE, NO | | | ONE FROM THE DESIGN TEAM HAS CONTACTED THIS OFFICE FOR | | | ANY COMMENTS OR QUESTIONS. | | | | | | DEWEY PALMER. | | | ELECTRICAL PLAN REVIEW | | | [email protected] | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-16 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-15 |
Time |
21:29 |
Sent To |
|
|
| Notes |
| 2006-09-16 00:00:00 | *** UNSAT *** | | | | | | ** PLEASE SEE SOME NOTES FORM PREVIOUS | | | REVIEW ARE STILL IN NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE VALUE FOR SCOPE OF | | | WORK WAS INCREASED BY THE $120K ON | | | RESPONSE. THE ADDITIONAL FEE WILL BE | | | OWED BEFORE PERMIT CAN BE ISSUED. | | | FEE OWED $1332.00 | | | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTE WHICH | | | REQUESTED ALL MANUFACTURES SPECS/CUT | | | SHEETS FOR THE UPS SYSTEM(S) EQUIPMENT, | | | ATS EQUIPMENT ETC. | | | RESPONSE MENTIONS THIS WERE TO BE | | | SUBMITTED , HOWEVER THESE WERE NOT | | | SUBMITTED FOR REVIEW. | | | 110.3,90.7 | | | | | | 3) NOTE: PLEASE SEE IT IS STILL UNCLEAR | | | IF THIS IS CONSIDERED AS "ONE BUILDING" | | | FROM THE DEFINITIONS AS SETFORTH IN THE | | | FBC. PLEASESEE DEFINITIONS ,, WALKWAYS, | | | ENCLOSED, OPEN ETC AND THE EXTEND OF THE | | | SIZE(S) NEEDED FOR THE CONSIDERATION OF | | | "ONE BUILDING". PLEASE KNOW, SOME OF | | | THIS LAYOUT OR INFORMATION MAY BE | | | SUPPLIED OR SHOWN ON SEPARATE SHEETS | | | FROM THE ARCHITECT ECT FOR | | | CLARIFICATION. | | | 225.31-225.39 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2006-09-15 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-29 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-29 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE ADDRESSING SHALL | | | CORRELATE, AS THE APPLICATION SHOWS 901 | | | S FLAGLER, THE PCN USED IS FOR 900 S | | | OLIVE, AND PLANS SHOWS 1101 S OLIVE. | | | PLEASE KNOW, ALL THESE SHALL CORRELATE | | | AND ONCE THE "ADDRESS" IS CORRECTED, | | | PLEASE MAKE SURE ALL TITLE BLOCKS ON ALL | | | SHEETS ARE CORRECTED. | | | FAC 61G1-16.004 | | | | | | 2) NOTE: PLEASE SEE COVER SHEETS STATES | | | DESIGN PER 2001 FBC, WHERE WE ARE | | | CURRENTLY UNDER THE 2004 FBC. | | | | | | 3) NOTE: PLEASE SEE PLANS SHALL INCLUDE | | | ALL THE CURRENT CODES ADOPTED AND IN | | | AFFECT IN THE STATE OF FLORIDA. | | | PLEASE SEE THE FOLLOWING CODES SHALL BE | | | STATED ON PLANS AT A MINIMUM. | | | NFPA-70 2002, NFPA-101 2003, NFPA-72 | | | 2002, NFPA-75 2003. | | | | | | 4) NOTE: PLEASE SEE VALUE FOR COMPLETE | | | SCOPE OF WORK SHALL BE ADJUSTED TO | | | INCLUDE ALL LABOR AND MATERIALS. | | | PLEASE KNOW, EVEN IF ANY EQUIPMENT IS | | | SUPPLIED BY THE OWNER. | | | VALUE AT THIS TIME IS LOW. | | | FBC ADMIN SECT 108.3 | | | | | | 5) NOTE: PLEASE SUBMIT MANUFACTURES | | | SPECS/CUT SHEETSFOR ALL NEW UPS | | | EQUIPMENT. | | | 110.3, 106.1.2 | | | | | | 6) NOTE: PLEASE SUBMIT MANUFACTURES | | | SPECS/CUT SHEETS FOR THE NEW ATS BEING | | | PROPOSED. | | | 110.3, FBC106.1.2 | | | | | | 7) NOTE: PLEASE SEE RISER MENTIONS TAPS | | | PER "220.21"? THIS SHOULD BE PER | | | "240.21" | | | PLEASE ALSO KNOW, NOTE MENTIONS NOT TO | | | BE LOCATED MORE THAN 10FT AWAY, HOWEVER | | | PLEASE KNOW AND NOTE ON PLANS, THAT ITS | | | THE CONDUCTOR LENGTH NOT THE DISTANCE. | | | PLEASE ADJUST NOTE. | | | 240.21, 215.5 | | | | | | 8) NOTE: PLEASE CLARIFY PLANS, RISER AS | | | PLANS SEEM TO BE SHOWING THE FEEDERS | | | COMING FROM A SEPARATE, DETACHED | | | BUILDING?? | | | IF THIS IS THE CASE PLEASE SEE | | | 225.31-225.39. | | | PLEASE ADJUST, AND PLEASE VERIFY THE | | | EXISTING AS THIS DOES NOT SEEM TO MEET | | | 225.31-225.39 | | | PLEASE ALSO SEE 250.32 FOR GROUNDING | | | ELECTRODE SYSTEM. | | | | | | 9) NOTE: PLEASE PROVIDE VD CALCULATIONS | | | FOR THE NEW FEEDERS FROM THE EXISTING | | | MAIN ELECTRICAL RM. | | | FBC 2004 13-413.1ABC.1 | | | | | | 10) NOTE: PLEASE PROVIDE A GROUNDING | | | RISER FOR ALL EQUIPMENT,UPS AND | | | ATTACHMENT LOCATION(S). 250.30,250.20, | | | 645.15 | | | | | | ** IMPORTANT** | | | | | | PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF THE OLD/VOIDED | | | SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-12-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-05 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-05 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2006-12-05 14:36:51 | *****APPROVED***** | | | | | | | | | | | | COMMENT #5 FROM PREVIOUS FIRE PLAN REVIEWS HAS BEEN | | | ADDRESSED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-24 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-24 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2006-10-24 13:31:18 | *****UNSAT***** | | | | | | YOUR RESPONSES TO FIRE PLAN REVIEW COMMENTS OF | | | 7/10/2006 RECEIVED AS: | | | | | | | | | 1.)OK | | | | | | 2.)OK | | | | | | 3.)OK | | | | | | 4.)OK | | | | | | 5.)BE ADVISED AS PER NFPA 101, 2003 EDITION, 10.2, | | | INTERIOR FINISH FOR WALLS AND CEILINGS IN EXITS AND | | | EXIT CORRIDORS SHALL BE CLASS "A" OR "B". | | | | | | 6.)SO NOTED. | | | | | | 7.)SO NOTED. | | | | | | 8.)OK | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-10 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-10 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | 1. DEMOLITION, CONSTRUCTION, AND | | | RENOVATION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 3. EXITS SHALL REMAIN CLEAR AND | | | ACCESSIBLE. | | | | | | 4. PLEASE EXPLAIN STAIR SHOWN IN | | | EXISTING COMPUTER ROOM. IS IT AN EXIT OR | | | WHERE DOES IT TERMINATE AT THE TOP AND | | | BOTTOM, PLEASE EXPLAIN. | | | | | | 5. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 6. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR PROPOSED PRE-ACTION FIRE SUPPRESSION | | | SYSTEM PLANNED FOR USE. | | | | | | 7. SEPARATE PLANS AND PERMITS REQUIRED | | | FOR ANY NEW FIRE ALARM EQUIPMENT PLANNED | | | TO BE INSTALLED. | | | | | | 8. PLEASE ILLUSTRATE ALL EXISTING OR NEW | | | EMERGENCY LIGHTS OR EXIT SIGNS IN THE | | | GENERAL OR VICINITY OF THE WORK BEING | | | PROPOSED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
10:03 |
Sent To |
E |
|
| Notes |
| 2007-05-03 10:03:27 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
20:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-29 |
Time |
20:30 |
Sent To |
|
|
| Notes |
| 2007-04-02 17:11:58 | TO COMM BOARD # 5 | | 2007-03-29 20:31:13 | WAITING FOR COMM BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-30 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-30 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2006-11-01 16:53:45 | TO "COMM" BD#28 | | 2006-10-30 16:08:22 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-07 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-07 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2006-09-13 00:00:00 | TO "COMM" BD#45 | | 2006-09-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-24 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-28 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | TO "BOB"#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-05-01 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-11 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-11 |
Time |
16:43 |
Sent To |
B1 |
|
| Notes |
| 2006-12-11 16:16:02 | PASS PRIVISO | | | PAGE M-3PLEASE PROVIDE A ENGINEER DRAWING ON TIE DOWN | | | OF CURB TO ROOF FOR ROUGH INSPECTION | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-17 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-17 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2006-10-17 09:29:58 | 1)PAGE M-4 REFRIGERANT PIPING THROUGH ROOF DETAIL | | | DOES NOT MATCH RESPONSE # 5 | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-20 |
Time |
13:58 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-20 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-07-20 00:00:00 | DENIED:2004 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET S2 DETAIL 1 & 3, | | | INDICATES A NEW CAP PLATE & I-BEAM TO BE | | | WELDED ONTO THE EXISTING POST. | | | DEMENSION OF 6" BETWEEN THE ROOF SURFACE | | | AND BOTTOM OF THE OF THE I-BEAM IS 6" | | | WITH THE CONDENSING UNITS LEGS ARE 2' | | | LONG.PER 2004 FBC 1509.7 WHERE ROOFING | | | MATERIALS EXTEND BENEATH THE UNIT ON | | | REAISED EQUIPMENT SUPPORTS, THE MINIMUM | | | CLEARANCE SHALL BE IN ACCORDANCE WITH | | | TABLE 1509.7 FROM THE ROOF SURFACE WO | | | THE BOTTOM OF THE SUPPORT RAIL.THE 6" | | | DOES NOT MEET THIS REQUIREMENT. | | | | | | 2.PLEASE CLARIFY DETAIL ON PLAN SHEET | | | M-3.REFRIGERANT LINES THROUGH THE | | | BUILDING TO THE ROOF SHALL COMPLY WITH | | | 2004 FBC 1514.2.5 THROUGH 1514.2.5.2 | | | | | | 3.PLEASE NOTE, REFRIGERANT LINS SHALL | | | COMPLY WITH ASHRAE 62-2001 | | | | | | 4.PLAN SHEET A-2 INDICATES A DETAIL | | | FOR PATE CURB FOR MULTPLE PIPES | | | PENETRATIONS.ARCHITECTURAL PLANS DO | | | NOT SHOW DETAIL OF THE GALVANIZED TROUGH | | | AS INDICATED ON PLAN SHEET M-3. | | | | | | 5.PLEASE CLARIFY THE REFRIGERANT | | | PIPING DETAIL THRU ROOF SHOWN ON PLAN | | | SHEET M-4.THIS INDICATES INSULATED | | | PIPING THROUGH CONCRETE ROOF SLAB, SHOW | | | COMPLIANCE WITH 2004 FMC 1107.2.1. | | | DETAIL ALSO INDICATES COUNTER FLASHING | | | TO BE SAME MATERIAL AS THE PIPE AND IS | | | TO BE SOLDERED TO REFRIGERANT LINE.IS | | | THIS CORRECT? | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-07 |
Time |
09:29 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2006-07-07 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | *** PROVISO *** | | | 1) PLEASE SEE ELECTRICAL REVIEW NOTES #1 | | | AND #2, AND CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-09-23 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-23 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2006-09-23 00:00:00 | RE-SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-01 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-01 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-01 |
Time |
06:20 |
Sent To |
|
|
| Notes |
| 2006-07-01 00:00:00 | PROVISO: | | | SHT. P-2 1ST FLOOR KEY NOTE #1 | | | 3/4" A/C CONDENSATE TO DRY WELL OR | | | PLANTER. |
|
|