Plan Review Details - Permit 06061461
Plan Review Stops For Permit 06061461
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-04-20 Cont ID  
Sent By lmartine Date 2007-04-20 Time 08:15 Rev Time 0.00
Received By lmartine Date 2007-04-20 Time 08:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status N Date 2007-04-19 Cont ID  
Sent By lmartine Date 2007-04-19 Time 18:56 Rev Time 0.00
Received By lmartine Date 2007-04-19 Time 18:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2007-04-19 Cont ID  
Sent By lmartine Date 2007-04-19 Time 18:44 Rev Time 0.00
Received By lmartine Date 2007-04-19 Time 18:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-03-30 Cont ID  
Sent By lmartine Date 2007-03-30 Time 18:11 Rev Time 0.00
Received By lmartine Date 2007-03-30 Time 18:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-27 Cont ID  
Sent By amorse Date 2006-10-27 Time 11:23 Rev Time 0.00
Received By amorse Date 2006-10-27 Time 11:20 Sent To PC
Notes
2006-10-27 11:38:31 
  
 DENIED
  
 NOTES FROM PREVIOUS REVIEW:
  
 1) OK , IMPACT FEES SHALL BE PAID UPON APPLICATION FOR
 PERMITTING
  
 2) OK , RADON FEES SHALL BE PAID UPON APPLICATION FOR
 PERMITTING
  
 3) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS
 ICC (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS
 SERVICES PER 108.3 FBC* THIS HAS BEEN CHANGED ON
 APPLICATION AND IN SYSTEM TO REFLECTNEW ICC BUILDING
 VALUATION DATA. NEW VALUE $649,850.00
  
 4) OK
  
 5) OK
  
 6) OK
  
 7) OK
  
 8) OK
  
 9) OK
  
 10) WILL BE PROVISO ON THE PERMIT SET
  
 11) OK
  
 12) REQUIRED AT TIME OF PERMIT APPLICATION
  
 NEW REVIEW COMMENTS:
  
 1) REVISED PAGES OF ARCHITECTURAL ARE NOT SIGNED AND
 SEALED
  
 2) PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-06 Cont ID  
Sent By amorse Date 2006-07-06 Time 15:01 Rev Time 3.00
Received By amorse Date 2006-07-06 Time 15:01 Sent To PC
Notes
2006-07-06 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 2) THE STATE OF FLORIDA REQUIRES
 COLLECTION OF A RADON SURCHARGE ON ALL
 NEW CONSTRUCTION COMPUTED ON UNDER ROOF
 FLOOR SPACE PER 10D-91 FAC
  
 3) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 4) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
  
 A) PROVIDE MODIFIED BITUMEN ROOF
 COVERING PRODUCT APPROVAL FOR FLAT ROOF
  
 B) PROVIDE CAST-CRETE PRODUCT APPROVAL
  
 C) THERMA TRU FIBERGLASS DOOR IS NOT
 IMPACT RESISTANT AND WILL REQUIRE
 OPENING PROTECTIVES
  
 D) AMARR GARAGE DOOR HAS NO IMPACT
 RATING SHOWN IN THE PRODUCT APPROVALS
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6) PROVIDE AT A MINIMUM ONE BATHROOM ON
 THE MAIN FLOOR LEVEL WITH A ACCESSABLE
 DOOR (MIN 29" CLEAR) PER R322.1.1 FBC
  
 7) PROVIDE LINTEL SCHEDULE FOR
 CAST-CRETE LINTELS WITH LENGTHS USED FOR
 SPECIFIC DOOR OR WINDOW OPENINGS (MIN 4"
 END BEARING PER 2104.1.5 FBC)
  
 8) MAKE CORRECTIONS TO ROOF SHEATHING
 NAIL PATTERN FOR CORNER ZONE 3 PER
 2304.9.1 FBC
  
 9) SPIRAL STAIRS SHALL MEET ALL OF THE
 REQUIREMENTS OF R311.5.8.1 OR 1009.9.3
 FBC
  
 10) SUBMIT ENGINEERED TRUSS DRAWINGS
 THAT COMPLY WITH R802.10.1 FBC WITH
 PERMIT APPLICATION OR BEFORE
 INSTALLATION
  
 11) INDICATE TYPE AND VALUE OF WALL AND
 CEILING INSULATION
  
 12) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
  
 NOTE:
 FBC = FLORIDA BUILDING CODE 2004
 FBC* = WEST PALM BEACH ADMINISTATIVE
 AMMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-12-22 Cont ID  
Sent By dpalmer Date 2007-12-22 Time 13:17 Rev Time 0.00
Received By dpalmer Date 2007-12-22 Time 13:17 Sent To PC
Notes
2007-12-22 13:22:37 
 REDLINED PLANS:
  
 SA IN KITCHEN SHALL BE A PHOTO-ELECTRIC EYE OR
 RE-SETTING TYPE FOR ALL DEVICES LOCATED WITHIN 20FT OF
 COOKING APPLIANCE. NFPA-72 11.8.3
 A LIGTING FIXTURE OF SOME TYPE WILL BE REQUIRED IN
 HALLWAY AND FOYER BEFORE FINAL. 210.70, LS 101 7.8
  

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-12-19 Cont ID  
Sent By dpalmer Date 2007-12-19 Time 16:35 Rev Time 0.00
Received By dpalmer Date 2007-12-19 Time 16:34 Sent To PC
Notes
2007-12-19 16:35:20** DENIED REVISION **
  
  
 1) NOTE: PLEASE KNOW EVEN AS PLANS ARE NOW UNDER THE
 RESPONSIBILITY OF THE LICENSED ELECTRICAL CONTRACTOR AS
 PERMITTED IN FS 471 AND 489, PLEASE BE SURE PLANS
 CONTAIN THE SIGNATURE OF THE QUALIFIER.
 FBC 106.1.2, 106.5 ETC
  
 2) NOTE: PLEASE SEE PLANS NOW HAVE RISER COMPLETELY
 REVISED. PLEASE CLARIFY IF THE NEW SERVICE IS A
 METER/MAIN COMBO. NO METER SHOWN ON RISER.
 PLEASE SEE PLANS ON E-2 STILL ACTUALLY SHOW A SEPARATE
 METER AND SEPARATE MAIN.
 PLEASE SEE THERE IS NO MENTION OF ANY MAINS OR OVER
 CURRENT PROTECTION FOR EITHER OF THE 200AMPS SUB
 PANELS. PLEASE PROVIDE SCHEDULE FOR *ASSUMED*
 METER/MAIN EQUIPMENT.
 230.70, 230.71, 230.72, 240.4 AND 310.16 ETC
 FBC 106.3.5.4
  
 3) NOTE: PLEASE KNOW THE NEW SPEAKERS SHOWN ON PLANS
 WILL BE REQUIRED TO BE UNDER A SEPARATE PERMIT. THESE
 PLANS MAY BE REFERENCED FOR PERMIT ONCE REVISIONS ARE
 CORRECTED.
 ** THIS IS NOTED FOR INFORMATION.
  
 4) NOTE: PLEASE SEE NFPA-72 11.8.3 AS THE SMOKE ALARM
 IN KITCHEN IS BEING SHOWN WITHIN 20FT OF COOKING
 APPLIANCE WHICH IS NOT PERMITTED. PLEASE KEEP IN MIND
 THE EXCEPTION IS THAT THE UNIT INSTALLED MUST BE A
 *PHOTO-ELECTRIC* RE-SETTING TYPE.
 ** THIS IS FOR INFORMATION WHICH WILL BE NEEDED BEFORE
 INSTALLATION OF UNIT AND FINAL.
  
 5) NOTE: PLEASE SEE THE HALLWAY BETWEEN DINING ROOM AND
 LIVING ROOM WILL REQUIRE A MINIMUM OF ONE LIGHT FIXTURE
 FOR EGRESS.
 THIS COULD BE REDLINED AND REVISED BEFORE FINAL OR
 REVISED SHOWING A FIXTURE OF SOME TYPE AT THIS TIME.
 THIS ALSO INCLUDES FOYER AREA.
 210.70, LS101 7.8
  
 6) NOTE: PLEASE SEE MISSING * EQUIPMENT GROUNDING
 CONDUCTORS* AFTER THE FIRST MEANS OF DISCONNECT FOR
 ALL.
 PLEASE SEE 250.122 FOR SIZING.
 250.24, 250.110 ETC
  
 7) NOTE: PLEASE INCLUDE AIC RATING FOR NEW SERVICE
 MAINS/EQUIPMENT.
 110.9
 FBC 106.1.2, 106.3.5.4
  
 ** ITEMS ON SHEETS E-2 & 3 MAY BE ADJUSTED AT THIS
 TIME, OR MAY BE REDLINED AND REVISED BEFORE FINAL.
 ITEMS ON SHEET E-4 NEED TO BE CORRECTED AT THIS TIME.
  
  
 ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY
 COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE
 DO NOT HESITATE IN CONTACTING THIS OFFICE.
 PLEASE SEE BELOW FOR CONTACT INFORMATION.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-04-13 Cont ID  
Sent By lmartine Date 2007-04-19 Time 18:49 Rev Time 0.00
Received By dpalmer Date 2007-04-13 Time 09:04 Sent To B
Notes
2007-04-13 09:51:22** REDLINED NOTES **
  
 * LOADS ON APPLIANCE LOAD SUMMARY STILL DO NOT
 CORRELATE WITH THE LOAD CALCULATIONS, LOADS ON LOAD
 CALCULATIONS APPLY.
  
 * PANEL "B" STILL SHOWN AS 100AMP RATED AND 42CIR, THIS
 IS TO VIF.
  
  
 ** ALL REVISIONS ARE TO BE SUBMITTED BEFORE ROUGH
 ELECRTRICAL INPSECTION.

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-02-25 Cont ID  
Sent By dpalmer Date 2007-02-25 Time 08:19 Rev Time 0.00
Received By dpalmer Date 2007-02-22 Time 08:52 Sent To M
Notes
2007-02-25 08:25:02*** UNSAT 3RD REVIEW ***
  
 ** PLEASE KNOW THIS IS THE FIRST REVIEW UNDER PERMIT
 APPLICATION.
  
 ** PLEASE SEE THAT THE PREVIOUS SUBMITTED SHEET E-2 IS
 THE SAME SHEET
  
  
 **
 1) NOTE: PLEASE SEE THAT PERMIT APPLICATION HAS ONLY
 NOW BEEN MADE AND IT IS AFTER THE NEW CODES HAVE GONE
 INTO EFFECT.
 PLEASE BE SURE ALL PLANS REFLECT THE LATEST ADOPTED
 CODES PER THE STATE OF FLORIDA. PLEASE SEE THE
 FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER
 8TH, 2006.
 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS
 SUBMITTED).
 2005 NFPA-70 (NEC).
 2002 NFPA-72
 2003 NFPA-101
 ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE
 REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR
 REVIEWER(S).
 PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH
 REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD
 BE REVISED ACCORDINGLY.
  
 2) NOTE: PLEASE SEE 2004 FBC W/2006 FOR NOTE REQUIRED
 FOR TYPE OF RECESSED LIGHTING FIXTURES PER
 13-606.1.ABC.1.2.4
  
 3) NOTE: PLEASE SEE DUE TO THE SHEET E-2 BEING THE
 EXACT SAME SHEET SUBMITTED PREVIOUSLY WITH NO REVISIONS
 MADE, PLEASE BE SURE TO SEE ALL COMMENTS FROM PREVIOUS
 REVIEW(S) AND SEE REDLINED PLANS WHICH ARE STILL IN
 SETS FROM PREVIOUS REVIEW.
  
 4) NOTE: PLEASE SEE LOAD CALCULATIONS SHALL BE DONE AND
 CODES STATED PER 2005 NEC/ NFPA-70. PLEASE SEE ALL ARE
 REFLECTED FROM THE 2002 NEC.
  
 5) NOTE:PLEASE SEE DUE TO SOME SHEETS BEING THE SAME
 SHEETS FROM PREVIOUS REVIEW THIS COMMENT STANDS.
 PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN
 SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY
 INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS
 ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN
 THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS
 OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE
 ALARMS.
 THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE
 OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED.
 BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE
 DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL
 NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY
 HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF
 SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS
 SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS
 SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS
 FOR OTHER NEW HOMES.
 ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC
 RESIDENTIAL CODE/ FBC AND IN NFPA-72.
 IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE.
  
 6) NOTE: PLEASE SEE PREVIOUS COMMENT WITH RESPECT TO
 THE NUMBER OF SMALL APPLIANCE CIRCUITS WHICH ARE
 REQUIRED TO BE FIGURED INTO THE LOAD CALCULATIONS PER
 210.52B1, 220.52, 210.11C1. THE ONLY SECTION WHICH WAS
 DIFFERENT ON PREVIOUS NOTES WAS 220.52 WHICH USED TO BE
 220.16. THIS IS THE SAME COMMENT MADE ON PREVIOUS
 REVIEWS. PLEASE BE SURE TO GO OVER ALL OF THESE TYPES
 OF CIRCUITS AND REVISE LOAD CALCULATIONS. (NOT ALL ARE
 INCLUDED AS SHOWN ON PLANS AND PANEL SCHEDULES).
  
 7) NOTE: PLEASE SEE PANEL *B* WHICH IS SHOWN AS 100AMPS
 AND 42 CIRCUIT. PLEASE VERIFY THIS AS 100AMPS PANELS
 ARE NOT MADE WITH 42CIRCUITS.
 PLEASE ALSO SEE PANEL *C* WHICH IS SHOWN AS 20 POLES
 AND 42 POLES?
 PLEASE CORRELATE EQUIPMENT. 110.3, 90.7.
 FBC 106.1.2 ADMIN SECTION.
  
 8) NOTE: PLEASE CLARIFY THE SECTION/DATE STATED ON
 PLANS WHICH LISTS THE LOAD CALCULATIONS PER A DATE OF
 9/25/1997? PLEASE SEE NOTES ABOVE WITH RESPECT TO THE
 CURRENT CODE OF 2005 NFPA-70.
  
 9) NOTE: PLEASE CORRELATE LOADS SHOWN FOR PANEL *C* ON
 PANEL *A* SCHEDULE WITH THAT OF THE LOAD SHOWN ON PANEL
 *C*.
 220.
 FBC 106.1.2
  
 10) NOTE: PLEASE CORRELATE ALL LOADS ON PANEL SCHEDULES
 WITH LOADS ON LOAD SUMMARY AND LOADS ON LOADS
 CALCULATIONS. PLEASE SEE THERE ARE SEVERAL WHICH DO NOT
 CORRELATE. PLEASE ALSO SEE THAT ALL LOADS ARE PERMITTED
 TO ROUND UP, BUT NOT PERMITTED TO ROUND DOWN.
 PLEASE SEE SOME LOADS ARE AS MUCH AS 800VA MORE ON
 PANEL SCHEDULE THAN IN LOAD CALCULATIONS ETC.
 PLEASE SEE 2005 NEC 220.
 FBC 106.1.2, 106.3.5.3.4
  
 11) NOTE: PLEASE SEE FS 489 PART I AS IT APPEARS PERMIT
 IS BEING APPLIED FOR AS OWNER/BUILDER YETHOMESTEAD
 AND RESISIDENCE IS ANOTHER LOCATION. PLEASE KNOW THAT
 DOCUMENTATION MAY BE REQUIREDFOR O/B IS MOVING INOT
 NEW RESIDENCE.
  
  
 ** PLEASE BE SURE TO SEE COMMENT S FROM PREVIOUS REVIEW
 AS SOME MAY STILL APPLY OR CORRELATE WITH THESE PLANS
 FOR SHEET E-2.
  
 ** PLEASE KNOW AS PLANS WERE ONLY SUBMITTED FOR **PLAN
 REVIEW** THE FIRST TWO TIMES, FS 553.80(2)(B) DOES NOT
 APPLY.
  
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2007-02-25 07:53:592007-02-25 07:53:59
 REVIEW CONTINUED

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-10-24 Cont ID  
Sent By dpalmer Date 2006-10-24 Time 12:01 Rev Time 0.00
Received By dpalmer Date 2006-10-24 Time 10:41 Sent To M
Notes
2006-10-24 12:00:01****** UNSAT2ND REVIEW ********
  
 ** PLEASE KNOW PLANS AHVE ONLY BEEN SUBMITTED FOR "PLAN
 REVIEW" ONLY AND EVEN IF PLANS PASS THEY CAN NOT BE
 STAMPED UNTIL SUCH TIME A PERMIT HAS BEEN APPLIED FOR
 .
 PLEASE SEE REVIEWS ARE BASED ON PLANS REVIEW FOR A
 "PROJECT" ONLY.
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE THE
 SAME AND SEE NEW NOTE DUE TO A CHANGE AND INFORMATION
 FOUND IN THE CODE.
 PLEASE SEE NOTE BELOW ARE TAKEN DIRECTLY FROM PREVIOUS
 REVIEW WITH NEW NOTES ADDED.
  
 1) NOTE:OK, HOWEVER PLEASE DO THE SAME WHEN
 RESUBMITTING PLANS FOR REVIEW ONCE AGAIN.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE BE SURE TO COMPLETELY
 REMOVE ANY OF THE OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT THE NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 THIS WILL HELP TO AVOID ANY DELAYS IN
 PROCESSING PROJECT.
 ** ONE COPY OF ANY OLD/VOIDED REMOVED
 SHEETS SHOULD BE SUBMITTED SEPARATELY
 FOR REFERENCE.
  
 2) NOTE:NO, PLEASE SEE LOADS SHALL BE FIGURED FOR ONE
 OR MORE. PLEASE SEE TWO SM APPL CIRCUITS ARE REQUIRED
 FOR MIN, HOWEVER PLEASE SEE CODES GIVEN FOR OTHERS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE CIRCUITING FOR
 BUTLERS PANTRY IS SHOWN ALSO FEEDING
 OUTSIDE GFI(S).
 PLEASE SEE 210.52B1 WHICH SPEAKS OF
 KITCHEN SM APPL AND AREAS OF THE LIKE.
 BUTLERS PANTRY SHALL BE CIRCUITED TO ONE
 OR MORE OF THE SMALL APPLICANCE
 CIRCUITS.
 LOADS SHALL BE FIGURED AT 1.5KW PER CIR.
 PLEASE ALSO OTHER CIRCUITS IN KITCHEN
 WHICH AARE NOT BEING SHOWN WITH LOADS
 ETC AT 1.5, VA OR ON ON ONE OR MORE OF
 THE SM APPL CIRCUITS.
 PLEASE KNOW, ALL CIRCUITS ABOVE THE TWO
 MIN SM APPL, SHALL ALL BE FIGURED AND
 SHOWN AT 1.5KW FOR EACH. IE; 4-CIRCUITS,
 6KW.
 210.11C1,210.52B1,220.16
  
 3) NOTE:OK.
  
 4) NOTE: OK.
  
 5) NOTE: OK.
  
 6) NOTE: OK, HOWEVER SEE NEW NOTE WITH RESPECT TO SD'S
 AND SA'S
  
 7) NOTE: OK, NO ELECTRICAL SHOWN, IF THIS NEEDED, THESE
 ITEMS WILL BE REQUIRED TO BE REVISED AT A LATER DATE.
 PLEAS KNOW, MAY GAS APPLIANCES ARE REQUIRED TO HAVE AN
 ELECTRICAL FEED OF SOME KIND FOR ELECTRONICS ETC. THIS
 IS NOT ANYTHIGN THAT NEEDS TO BE CORRECTED ON PLANS.
  
 8) NOTE: NO, PLEASE SEE LOAD CALCULATIONS STILL DO NOT
 INCLUDE ALL LOADS FOR DEDICATED EQUIPMENT. PLEASE SEE
 LOADS ON PANELS "B" AND "C" STILL DO NOT CORRELATE WITH
 PANEL "A". PLEASE SEE THERE ARE MANY IEMS WHICH ARE
 DEDICATED LAODS NOT FIGURED.
 PLEASE SEE NEC 220.31 AND SHOW ALL LOADS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE LOAD CALCULATIONS
 SHALL INCLUDE ALL LOADS ON PANEL "B" AND
 "C". PLEASE SEE LOADS SHOWN FOR PANEL
 "C" IS ONLY SHOWN AT 5.9KW, YET THE
 LOADS ON PANEL "C" WAY EXCEED THIS.
 PLEASE SHOW LOADS ON EACH PANEL, AND
 INDICATE INDICATE THIS BREAK DOWN FOR
 EACH IN LOAD CALCUALTIONS.
 215.5, 220
  
 9) NOTE: NO, PLEASE SEE THERE ARE STILL SOME MISSING AS
 REQUIRED PER 210.52
  
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE MISSING RECEPTS PER
 210.52 MANY OF THESE ARE REDLINED ON ONE
 OF THE SETS OF PLANS.
 PLEASE SEE 3RD FLR, IF THIS AREA IS
 ENCLOSED, RECEPTS WILL BE REQUIRED.
 PLEASE ALSO SEE BUILDING COMMENTS IF 3
 FLRS OF HABITABLE SPACE.
  
 10) NOTE: OK.
  
 11) NOTE: OK.
  
 12) NOTE: NO, PLEASE SEE GUEST RM, MISSING DESIGNATION
 ON ELECTRICAL PLANS, AND CIRCUITING FOR RECETPS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE 408.4 WHERE THE
 PANEL SCHEDULE SHALL BE SPECIFIC FOR
 ROOMS AND ALL AREAS. MOST ARE DONE.
 IE: BEDRM #3 RECEPTS , LIV RM LTS ETC
 ** IT IS KNOWN, THAT DURING CONSTRUCTION
 THESE CIRCUITS MAY CHANGE AND CAN BE
 REVISED AT A LATER DATE.
 PLEASE SEE SOME ARE ONLY SHOWN AS GFI,
 ETC. WHEREAS THE SM APPL CIRCUITS ETC
 SHALL BE SPECIFIC.
  
 13) NOTE: OK.
  
 14) NOTE: OK.
  
 15) NOTE:NO, PLEASE SEE NOT ALL CIRCUITS WHICH
 REQUIRE AFCI PROTECTION ARE SHOWN THIS WAY. PLEASE SEE
 A-31AND VERIFY ALL OTHERS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE ARC FAULT
 PROTECTION IS REQUIRED FOR ALL CIRCUITS
 IN BEDRMS , NOT ONLY RECEPTS. THIS
 REQUIREMRNT WAS CHANGED FROM THE 1999
 NEC. THE 2002 NEC 210.12B REQUIRES ALL
 "OUTLETS" TO BE PROTECTED ON THAT BRANCH
 CIRCUIT. THIS INCLUDES, LTS, RECEPTS,
 SD'S, FANS ETC.
  
 16)NOTE: OK, HOWEVER WITH THE AIC RATING BEING SHOWN
 AT 10K, PLEASE KNOW IF THE LOCATION CONTAINS AN OLDER
 TRANSFORMER, IT IS KNOWN TO THIS OFFICE THAT MANY OF
 THE OLDER TRANSFORMER ARE BEING CHNAGED OUT AND SOME
 CONSIDERATION FOR FUTURE KVA SIZE SHOULD BE GIVE. THIS
 IS ONLY NOTED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 17) NOTE: OK.
  
 18) NOTE:NO, PLEASE SEE MISSING REQUIRED FOOTER
 STEEL. SHOWS OTHERS, HOWEVER THE FOOTER STEEL IS
 REQUIRED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE 250.50 FOR MIN
 GROUNDING ELECTRODE SYSTEM AT MAIN
 HOUSE. NEW FOOTER STEEL, CWP, GRND ROD
 WILL BE REQUIRED.
  
 19) NOTE:OK.
  
 20) NOTE:NO, AS NOTED ABOVE. PLEASE SEE SOME AREAS
 ARE MISSING SOME CIRCUITING. SEE REDLINED (GUEST RM).
 AND OTHER POSSIBLE LOCATIONS.
 NOT ALL AREAS AS REDLINED
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE SOME ITEMS/RECEPTS
 ARE MISSING CIRCUITING ON PLANS. THESE
 ARE MINOR AND HAVE BEEN REDLINED, ALONG
 WITH SD'S.
 FBC ADMIN SECT 106.1.2
  
 21) NOTE:NO, PLEASE SEE NOTE #2 ABOVE. PLEASE SEE
 LOADS, ECT REQUIRED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE THE DINING RM
 RECEPTS SHALL BE EITHER ON ONE OR MORE
 OF THE REQUIRED DEDICATED SMA PPL
 CIRCUITS OR ON THEIR OWN. 210.11C1,220.16,210.52B1
  
 22) NOTE: OK.
  
 23) NOTE: OK.
  
 24) NOTE: OK, HOWEVER PLEASE SEE BOTH GDO'S (GARAGE
 DOOR OPENERS) ARE BEING SHOWN ON ONE CIRCUIT WITH A
 LOAD OF 900A FOR BOTH. PLEASE VERIFY THIS AS THE
 TYPICAL SIZE OF A GDO IS LARGE ENOUGH WHERE EACH
 REQUIRES A DEDICATED CIRCUIT. PLEASE SEE 430.148 AND
 VERIFY AS THIS WOULD BE THE TIME TO REVISE IF NEEDED.
 PLEASE ALSO REVISED CALCULATIONS IF NEEDED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE CLARIFY GDO AS THESE
 LOCATIONS ARE SHOWING "J" BOXES AND NOT
 RECEPTS. PLEASE KNOW, IF THE GDO'S ARE
 PLUG-IN TYPE, THEN RECEPTS SHOULD BE
 SHOWN.
 106.1.2
  
 *** NEW NOTE ***
  
 25) NOTE: PLEASE SEE NFPA-72 2002 DEFINITIONS OF SMOKE
 DETECTORS AND SMOKE ALARMS. PLEASE ADJUST SYMBOL
 DESIGNATIONS ON PLANS IF THESE ARE INDEED NOT ONLY
 DETECTION DEVICES ARE NOTPART OF A FA SYSTEM/SECURITY
 SYSTEM. IF THESE ARE DEVICES WHICH DETECT AND SOUND
 THESE ARE CONSIDERED SA'S SMOKE ALARMS. PLEASE KNOW THE
 CLARIFICATION FROM NFPA AND THE CODE PANELIST WAS GIVEN
 RECENTLY SINCE THE LAST REVIEW.
 PLEASE ADJUST PLANS.
  
  
 ** PLEASE KNOW,MANY OF THE ABOVE ITEMS
 ARE REDLINED ON ONE OF THE SETS OF
 PLANS, HOWEVER IS IN NO WAY ALL
 LOCATIONS AS NOTED ABOVE.
  
 ** PLEASE SUBMIT THE ABOVE FOR REVIEW
 AND IF THERE ARE ANY QUESTIONS OR
 COMMENTS, PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  
2006-10-24 10:42:39RECEIVED FROM"INCOMING" ON 10/24/06, PLANS WERE NOT
 ROUTED ON 10/6 TO ELECTRICAL.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-30 Cont ID  
Sent By dpalmer Date 2006-06-30 Time 14:53 Rev Time 0.00
Received By dpalmer Date 2006-06-30 Time 09:27 Sent To M
Notes
2006-06-30 00:00:00****** UNSAT ********
  
 1) NOTE: PLEASE BE SURE TO COMPLETELY
 REMOVED ANY OF THE OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT THE NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 THIS WILL HELP TO AVOID ANY DELAYS IN
 PROCESSING PROJECT.
 ** ONE COPY OF ANY OLD/VOIDED REMOVED
 SHEETS SHOULD BE SUBMITTED SEPARATELY
 FOR REFERENCE.
  
 2) NOTE: PLEASE SEE CIRCUITING FOR
 BUTLERS PANTRY IS SHOWN ALSO FEEDING
 OUTSIDE GFI(S).
 PLEASE SEE 210.52B1 WHICH SPEAKS OF
 KITCHEN SM APPL AND AREAS OF THE LIKE.
 BUTLERS PANTRY SHALL BE CIRCUITED TO ONE
 OR MORE OF THE SMALL APPLICANCE
 CIRCUITS.
 LOADS SHALL BE FIGURED AT 1.5KW PER CIR.
 PLEASE ALSO OTHER CIRCUITS IN KITCHEN
 WHICH AARE NOT BEING SHOWN WITH LOADS
 ETC AT 1.5, VA OR ON ON ONE OR MORE OF
 THE SM APPL CIRCUITS.
 PLEASE KNOW, ALL CIRCUITS ABOVE THE TWO
 MIN SM APPL, SHALL ALL BE FIGURED AND
 SHOWN AT 1.5KW FOR EACH. IE; 4-CIRCUITS,
 6KW.
 210.11C1,210.52B1,220.16
  
 3) NOTE: PLEASE SEE PLANS SHALL
 REFERENCE THE CURRENT CODES IN EFFECT.
 PLEASE SEE PLANS NOW INDICATE THE
 "LATEST CODES". WE ARE NOT CURRENTLY
 UNDER THE LATEST CODES AS THEY HAVE NOT
 YET BEEN ADOPTED BY THE STATE OF
 FLORIDA.
 PLEASE SEE THE FOLLOWING AT A MIN SHOULD
 BEON PLANS. 2002 NFPA-70, 2003 NFPA-101,
 2002 NFPA-72.
  
 4) NOTE: PLEASE SEE MORE THAN ONE
 ENGINEERING TITLE BLOCK IS BEING SHOWN
 ON PLANS.???
 PLEASE KNOW, ONE SHALL BE THE
 RESPONSIBLE FIRM. ANY OTHER CONSULTING
 FIRMS ETC SHALL ALL INDICATE THEIR
 REQUIRED INFORMATION ON SAID TITLE
 BLOCKS. FAC 61G15-23.002, FAC
 61G1-16.004, FS 471.023, FS 481.219
  
 5) NOTE: PLEASE SEE MISSING EGRESS
 LIGHTING CONTROLS IN MANY LOCATIONS.
 PLEASE SEE ALL RMS IN HOUSE WHICH
 INDICATE A SW FOR A FAN AND A
 FAN J-BOX ONLY??
 PLEASE KNOW, A LT FIXTURE WILL BE
 REQUIRED OR 1/2 SWITCHED RECEPT.
 PLEASE SEE OTHER LOCATIONS IN MAIN HOUSE
 FOR LOCATIONS OF MEANS OF EGRESS AND
 WHERE A LT FIXTURE OF SOME SORT WILL BE
 REQUIRED. PLEASE SEE RMS( BEDRM #1)
 WHERE ALL THE RECEPTS ARE SHOWN BEING
 SWITCHED? (AS SHOWN) IF THIS IS INDEED
 THE CASE, THEN PLEASE ALSO PROVIDE
 RECEPTS WHICH ARE NOT SWITCHED OR 1/2
 SWITCHED TO MEET 210.52
 (THIS APPEARS TO BE A MISPRINT).
 PLEASE SEE EGRESS TO UPPER TOWER FLR
 DOES NOT INDICATE A "S"3/ LEADING TO THE
 FLR ABOVE AND UPPER TOWER ONLY SHOWS A
 "S" FOR LT.
  
 6) NOTE: PLEASE SEE SD'S ARE NOTALL
 SHOWN WITH CIRCUITING? PLEASE SEE SD'S
 ARE BEING SHOWN CIRCUITED TO MORE THAN
 ONE CIRCUIT ON PANELS.
 PLEASE KNOW, THE SD'S IN DWELLING CAN
 BE CIRCUITED TO ONE OF THE ARC FAULT
 PROTECTED BEDRM LIGHTING/RECEPT
 CIRCUITS. THIS WILL ALLEAVIATE THE
 TURNING OFF OF THIS CIRCUIT AND LEAVING
 THE ENTIRE DWELLING WITH OUT SD
 PROTECTION. ( THIS WOULD ALSO ALLEAVIATE
 THE ADDITIONAL AFCI BRKR)
 215.5 NFPA-72 11.8.3
 ** PLEASE SEE 11.8.3 AS STATED ABOVE,
 MISSING SD WHICH IS REQUIRED INSIDE ALL
 SLEEPING ROOMS. PLEASE KNOW SD IN BEDRM
 #1 SHALL BE "IN" THE BEDRM AREA. PLEASE
 KNOW, SD'S SHALL BE INSTALLED WITH IN 3'
 OF THE PEAK ON A SLOPED CEILING.
 PLEASE SEE IF UPPER TOWER/FLR IS CLOSED
 IN, THEN A SD AT THAT LEVEL WILL BE
 REQUIRED.
 PLEASE SEE NO DOORS ARE SHOWN LEADING TO
 THE FLR BELOW AND IT SEEMS THAT THIS
 SPACE IS ENCLOSED.
  
 7) NOTE: PLEASE SEE IT IS KNOWN THAT THE
 RANGE, WH ETC MAY BE GAS , HOWEVER NO
 ELECTRICAL IS BEING SHOWN TO THESE UNITS
 FOR IGNITER'S, ETC.??
  
 8) NOTE:PLEASE SEE LOAD CALCULATIONS
 SHALL INCLUDE ALL LOADS ON PANEL "B" AND
 "C". PLEASE SEE LOADS SHOWN FOR PANEL
 "C" IS ONLY SHOWN AT 5.9KW, YET THE
 LOADS ON PANEL "C" WAY EXCEED THIS.
 PLEASE SHOW LOADS ON EACH PANEL, AND
 INDICATE INDICATE THIS BREAK DOWN FOR
 EACH IN LOAD CALCUALTIONS.
 215.5, 220
  
 9) NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52 MANY OF THESE ARE REDLINED ON ONE
 OF THE SETS OF PLANS.
 PLEASE SEE 3RD FLR, IF THIS AREA IS
 INCLOSED, RECEPTS WILL BE REQUIRED.
 PLEASE ALSO SEE BUILDING COMMENTS IF 3
 FLRS OF HABITABLE SPACE.
  
 10) NOTE: PLEASE SEE SOME CIRCUITS ARE
 NOTED SHOWING GFI RECEPTS AND ALSO GFI
 BREAKERS IN PANELS??
 THIS IS OK, HOWEVER IF SHOWN THIS WAY,
 THEN THIS WILL BE REQUIRED.
 **THIS IS ONLY A NOTE;
  
 11) NOTE: PLEASE CORRELATE FEEDER TO
 PANEL "C" WITH PANEL "A" SCHEDULE. 310.16,240.4,215.5
  
 12) NOTE: PLEASE SEE 408.4 WHERE THE
 PANEL SCHEDULE SHALL BE SPECIFIC FOR
 ROOMS AND ALL AREAS. MOST ARE DONE.
 IE: BEDRM #3 RECEPTS , LIV RM LTS ETC
 ** IT IS KNOWN, THAT DURING CONSTRUCTION
 THESE CIRCUITS MAY CHANGE AND CAN BE
 REVISED AT A LATER DATE.
 PLEASE SEE SOME ARE ONLY SHOWN AS GFI,
 ETC. WHEREAS THE SM APPL CIRCUITS ETC
 SHALL BE SPECIFIC.
  
 13) NOTE: PLEASE INDICATE TH GFI
 PROTECTION FOR THE JACUZZI TUB.
 210.8,680.71
  
 14) NOTE: PLEASE INDICATE TH RM WHERE
 THE AHU #2 AS MECH/ELEC RM. NO STORAGE
 PERMITTED.
 110.26,408.7,240.24
  
 15) NOTE: PLEASE SEE ARC FAULT
 PROTECTION IS REQUIRED FOR ALL CIRCUITS
 IN BEDRMS , NOT ONLY RECEPTS. THIS
 REQUIREMRNT WAS CHANGED FROM THE 1999
 NEC. THE 2002 NEC 210.12B REQUIRES ALL
 "OUTLETS" TO BE PROTECTED ON THAT BRANCH
 CIRCUIT. THIS INCLUDES, LTS, RECEPTS,
 SD'S, FANS ETC.
  
 16)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 17) NOTE: PLEASE SEE RISER IS SHOWING
 "EQUIPMENT GROUNDING CONDUCTORS" FROM
 METER TO MAINS. PLEASE SEE THE EQP GRNDS
 ARE ONLY INSTALLED AFTER THE FIRST MEANS
 OF DISCONNECT.
 250.6,250.24B
  
 18) NOTE: PLEASE SEE 250.50 FOR MIN
 GROUNDING ELECTRODE SYSTEM AT MAIN
 HOUSE. NEW FOOTER STEEL, CWP, GRND ROD
 WILL BE REQUIRED.
  
 19) NOTE: PLEASE SEE NO HAND DRAWN
 CHANGES AREPERMITTED ON PLANS WHICH
 ARE SIGNED, DATED AND SEALED BY THE
 ARCHITECT OR ENGINEER.
 FS 481.221, 471.025
 PLEASE KNOW, "IF" SOME VERY MINOR ITEMS
 ARE ADDED, THEN EACH ITEM MAY BE DONE
 WITH THE DESIGN PROFESSIONAL OF RECORD
 SIGNING AND DATING EACH ITEM.
  
 20) NOTE: PLEASE SEE SOME ITEMS/RECEPTS
 ARE MISSING CIRCUITING ON PLANS. THESE
 ARE MINOR AND HAVE BEEN REDLINED, ALONG
 WITH SD'S.
 FBC ADMIN SECT 106.1.2
  
 21) NOTE: PLEASE SEE THE DINING RM
 RECEPTS SHALL BE EITHER ON ONE OR MORE
 OF THE REQUIRED DEDICATED SMA PPL
 CIRCUITS OR ON THEIR OWN. 210.11C1,220.16,210.52B1
  
 22) NOTE: PLEASE GO THROUGH ALL SWITCHES
 ON PLANS AS SOME ARE SHOWN AS SINGLE
 POLE SWITCHES, YET THEY SHOULD BEBUT
 NOT GOING TO ANYTHING, OTHERS SHOULD BE
 3-WAY, BUT NOT CLEAR? SEE NOTE ABOVE.
  
 23) NOTE: PLEASE CORRLELATE ALL A/C
 SYSTEMS, OCP AND LOADS, AS THESE SHOWN
 ON ELECTRICAL PANEL SCHEDULE DO NOT
 MATCH WITH THOSE AS SHOWN ON MECH
 SHEETS.
  
 24) NOTE: PLEASE CLARIFY GDO AS THESE
 LOCATIONS ARE SHOWING "J" BOXES AND NOT
 RECEPTS. PLEASE KNOW, IF THE GDO'S ARE
 PLUG-IN TYPE, THEN RECEPTS SHOULD BE
 SHOWN.
 106.1.2
  
 ** PLEASE KNOW,MANY OF THE ABOVE ITEMS
 ARE REDLINED ON ONE OF THE SETS OF
 PLANS, HOWEVER IS IN NO WAY ALL
 LOCATIONS AS NOTED ABOVE.
  
 ** PLEASE SUBMIT THE ABOVE FOR REVIEW
 AND IF THERE ARE ANY QUESTIONS OR
 COMMENTS, PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  
  

Review Stop G GAS REVIEW
Rev No 4 Status N Date 2007-04-20 Cont ID  
Sent By lmartine Date 2007-04-20 Time 08:17 Rev Time 0.00
Received By lmartine Date 2007-04-19 Time 18:45 Sent To  
Notes
2007-04-19 18:48:24GAS REVIEWS WERE NEVER PASSED , SEPERATE GAS PERMIT IS
 REQUIRED WITH COMPLETE PLANS TO BE SUBMITTED FOR REVIEW
 AND APPROVAL BEFORE INSTALLATION.
  
  
  
  
 L.MARTINEZ
 561-805-6710

Review Stop G GAS REVIEW
Rev No 3 Status F Date 2007-02-27 Cont ID  
Sent By jleech Date 2007-02-27 Time 08:23 Rev Time 0.00
Received By jleech Date 2007-02-27 Time 08:02 Sent To P
Notes
2007-02-27 08:22:56DENIED;
 1.P.E. PIPE CAN ONLY BE USED OUT SIDE OF THE HOUSE. SEE
 FBC-2004 FUEL GAS SECTION 404.14.1
 2. LIST THE OTHER PIPE MATERIALS TO BE USED INSIDE THE
 HOUSE AND LIST TABLES TO BE USED.
 3. LIST SIZE OF SLEEVES TO BE USED AND TYPE OF
 MATERIAL.
 GAS PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2006-10-27 Cont ID  
Sent By jleech Date 2006-10-27 Time 08:30 Rev Time 0.00
Received By jleech Date 2006-10-27 Time 08:30 Sent To B
Notes
2006-10-27 08:41:10DENIED;
 1. INDICATE PIPE MATERIAL USED IN HOUSE.
 2. GAS PIPE UNDER SLAB SHALL BE SLEEVED WITH A VENT TO
 THE OUTSIDE. FBC-2004 FUEL GAS SECTION 404.11.
 3.LIST SIZING TABLES USED SEE FBC-2004 FUEL GAS;
 METALLIC PIPE 402.4 (2)
 CORRUGATED STAINLESS STEEL TUBING 402.4
 (14)
 POLYETHYLINE PIPE 402.4 (20)
 GAS PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2006-07-06 Cont ID  
Sent By jleech Date 2006-07-06 Time 08:59 Rev Time 0.00
Received By jleech Date 2006-07-06 Time 08:59 Sent To B
Notes
2006-07-06 00:00:00DENIED;
 1. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 2. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 3. TYPE OF GAS, (LP OR NATURAL)
 4. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 GAS REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-12-20 Cont ID  
Sent By mmiller Date 2007-12-20 Time 17:13 Rev Time 0.00
Received By mmiller Date 2007-12-20 Time 17:13 Sent To  
Notes
2007-12-20 17:14:02ROUTED TO DEWEY PALMER'S DESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-12-14 Cont ID  
Sent By adarroug Date 2007-12-14 Time 13:22 Rev Time 0.00
Received By adarroug Date 2007-12-14 Time 13:22 Sent To E
Notes
2007-12-14 13:22:27TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-12-13 Cont ID  
Sent By adarroug Date 2007-12-13 Time 10:25 Rev Time 0.00
Received By adarroug Date 2007-12-13 Time 10:25 Sent To M
Notes
2007-12-13 10:25:50TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-11-16 Cont ID  
Sent By adarroug Date 2007-11-16 Time 14:23 Rev Time 0.00
Received By adarroug Date 2007-11-16 Time 14:23 Sent To M
Notes
2007-11-16 14:23:42TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-07-26 Cont ID  
Sent By adarroug Date 2007-07-26 Time 11:40 Rev Time 0.00
Received By adarroug Date 2007-07-26 Time 11:40 Sent To B
Notes
2007-07-26 11:41:03TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-07-17 Cont ID  
Sent By adarroug Date 2007-07-17 Time 09:05 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 09:05 Sent To B
Notes
2007-07-17 09:06:12TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-04-04 Cont ID  
Sent By spalmer Date 2007-04-04 Time 17:46 Rev Time 0.00
Received By spalmer Date 2007-04-04 Time 17:46 Sent To Z
Notes
2007-04-04 17:47:03TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-02-20 Cont ID  
Sent By adarroug Date 2007-02-20 Time 15:05 Rev Time 0.00
Received By adarroug Date 2007-02-20 Time 15:05 Sent To E
Notes
2007-02-20 15:05:45TO "DPALMER" DESK/PROJECT TO PERMIT

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-05 Cont ID  
Sent By adarroug Date 2007-02-05 Time 16:29 Rev Time 0.00
Received By adarroug Date 2007-02-05 Time 16:29 Sent To Z
Notes
2007-02-05 16:29:44TO "Z" BOX/RESUB--PROJECT TO PERMIT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-10-06 Cont ID  
Sent By adarroug Date 2006-10-24 Time 11:16 Rev Time 0.00
Received By adarroug Date 2006-10-06 Time 11:16 Sent To E
Notes
2006-10-06 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-07-06 Time   Rev Time 0.00
Received By adarroug Date 2006-06-27 Time 16:05 Sent To  
Notes
2006-06-27 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-12-13 Cont ID  
Sent By tgordon Date 2007-12-13 Time 12:02 Rev Time 0.25
Received By tgordon Date 2007-12-13 Time 12:02 Sent To  
Notes
2007-12-13 12:03:01REVISION TO MEDCH. PLANS PAGES M1 OF 2 AND M2 OF 2.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-11-29 Cont ID  
Sent By tgordon Date 2007-11-29 Time 10:48 Rev Time 0.40
Received By tgordon Date 2007-11-29 Time 10:48 Sent To  
Notes
2007-11-29 10:49:39REVISION TO MECH. PLANS AND ENERGY CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-02-26 Cont ID  
Sent By tgordon Date 2007-02-26 Time 09:19 Rev Time 0.35
Received By tgordon Date 2007-02-26 Time 09:19 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-10-24 Cont ID  
Sent By tgordon Date 2006-10-24 Time 15:54 Rev Time 0.30
Received By tgordon Date 2006-10-24 Time 15:54 Sent To P
Notes
2006-10-24 16:01:13** FOR PLAN REVIEW ONLY NOT FOR PERMIT **
  
 1) MECHANICAL PLANS WILL BE ABLE TO PASS REVIEW AFTER
 #2 CORRECTION.
  
 2) PLEASE SHOW ON REAL FYRE BOOKLET WHICH GAS BURNER
 SYSTEM IS TO BE INSTALLED IN FIRE PLACE WHEN SUBMITTING
 FOR PERMIT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-06-30 Cont ID  
Sent By tgordon Date 2006-06-30 Time 15:46 Rev Time 1.00
Received By tgordon Date 2006-06-30 Time 15:45 Sent To P
Notes
2006-06-30 00:00:00FOR PLAN REVIEW ONLY NOT FOR PERMIT.
 *** DENIED ***
 1) PLEASE SUBMIT A COMPLETE MANUAL J
 CALCULATION SHOWING EACH ZONE, PER 2004
 FBC 13-607.1.ABC.1 .
  
 2) SHOW A/C SYSTEMS TOTAL, AND SENSIBLE
 BTU'S ON MECHANICAL PLANS EQUIPMENT
 LISTING.
  
 3) PLEASE SUBMIT DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR GAS FIREPLACE & HEATER,
 AND GAS BBQ GRILL & HOOD.
  
 4) GUEST BEDROOM SHOWS A 10X10 SUPPLY
 AIR DUCT WITCH MAKES THE 10" RETURN AIR
 TRANSFER DUCT TO SMALL, PLEASE CORRECT.
  
 5) 12" RETURN AIR TRANSFER DUCT IN
 MASTER BEDROOM SUITE NEEDS TO BE 14",
 PLEASE SEE 2004 FBC/R M1602.4 .
  
 6) AHU #2 14X12 RETURN AIR DUCT NEEDS TO
 BE 26X12, AS IT IS ACTING AS A TRANSFER
 DUCT, SEE 2004 FBC/R M1602.4 .
  
 7) AHU #2 10X10 RETURN AIR DUCT NEEDS TO
 BE 16X10 FOR SAME REASON AS NOTE #6.
  
 8) PLEASE SEE ELECTRICAL REWIEW NOTES
 #3, 4, AND 23.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-02-27 Cont ID  
Sent By jleech Date 2007-02-27 Time 08:36 Rev Time 0.00
Received By jleech Date 2007-02-27 Time 08:36 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-10-27 Cont ID  
Sent By jleech Date 2006-10-27 Time 08:26 Rev Time 0.00
Received By jleech Date 2006-10-27 Time 08:26 Sent To B
Notes
2006-10-27 08:29:37PLUMBING PLAN IS TO CODE. WHEN WHEN PERMIT APPLICATION
 IS SUBMITED PLUMBING PLAN WILL BE STAMPED
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-06 Cont ID  
Sent By jleech Date 2006-07-06 Time 08:57 Rev Time 0.00
Received By jleech Date 2006-07-06 Time 08:50 Sent To G
Notes
2006-07-06 00:00:00DENIED;
 1.WATER DIAGRAM; WATER HAMMER ARRESTORS
 ARE REQUIRED WHERE QUICK CLOSING VALVES
 ARE INSTALLED @ W/M, REFIG., AND D/W'S.
 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN
 REQUIRED TO BE 3" SEC.406.3. CLEANOUT TO
 BE INSTALLED AT 48" AFF.
 3.SHOW TERMAL EXPANTION CONTROL METHOD
 PER. SEC.607.3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695
  
  
  
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 4 Status P Date 2007-04-16 Cont ID  
Sent By adavila Date 2007-04-16 Time 16:32 Rev Time 0.00
Received By adavila Date 2007-04-16 Time 13:55 Sent To B
Notes
2007-04-16 16:32:26PLANNING AND ZONING DEPARTMENT
  
 ***PASSED***
  
 PROVISO THE PROPOSED A/C SHALL NOT BE CLOSER THAN ONE
 (1) FOOT FROM THE WEST SIDE PROPERTY LINE.
  
 MUST PULL A SEPARATE PERMIT FOR POOL/SPA/DECK/SCREEN
 ENCLOSURE AND ALSO A FENCE/WALL/GATE PERMIT WITH
 EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH
 PUBLIC UTILITIES DEPARTMENT.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 3 Status F Date 2007-04-06 Cont ID  
Sent By adavila Date 2007-04-06 Time 15:15 Rev Time 0.00
Received By adavila Date 2007-04-06 Time 15:15 Sent To I
Notes
2007-04-06 15:19:14PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.ACCORDING TO THE PLANS, THE TOP OF PARAPET WILL BE
 3 FEET FROM TOP OF SLAB.HOWEVER, MEASURED, THE TOP OF
 PARAPET WILL BE 2 FEET 6 INCHES FROM TOP OF SLAB.
 PLEASE CORRECT BUILDING HEIGHT DIMENSIONS ON
 ELEVATIONS.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-02-16 Cont ID  
Sent By adavila Date 2007-02-16 Time 11:23 Rev Time 0.00
Received By adavila Date 2007-02-16 Time 11:23 Sent To I
Notes
2007-02-16 11:36:05PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2. PER ARTICLE XIX, DEFINITIONS, OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS, BUILDING HEIGHT MEANS THE
 VERTICAL DISTANCE FROM THE MEAN GRADE OF A LOT AT THE
 FRONTAGE OF THE BUILDING TO THE HIGHEST POINT OF THE
 TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK
 LINE OF A MANSARD ROOF, OR TO THE MID-HEIGHT LEVEL
 BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL
 ROOFS.
 A. PROPOSED RESIDENTIAL STRUCTURE EXCEEDS THE PERMITTED
 BUILDING HEIGHT PER THE SINGLE FAMILY HIGH DENSITY
 (SF14) RESIDENTIAL ZONING REGULATIONS (30 FEET), AS
 PLANS SHOW BUILDING HEIGHT MEASURED FROM THE FINISHED
 FLOOR.
  
 3. PER SECTION 94-306, HEIGHT EXCEPTIONS, OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, HEATING, VENTILATION
 AND AIR CONDITIONING EQUIPMENT, CHURCH STEEPLES, BELL
 TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, STAIR
 ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR
 HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS,
 AND RELATED MECHANICAL OR FUNCTIONAL FEATURES, MAY
 EXCEED DISTRICT HEIGHT BY TEN (10) PERCENT.
 A. THE PARAPET, DECORATIVE FEATURES, AND CAST STONE
 URNS ON THE PROPOSED TOWER EXCEED THE BUILDING HEIGHT
 EXCEPTION OF 3 FEET (10 PERCENT).
  
 4. PLEASE PROVIDE ELEVATION HEIGHT TO THE
 HIGHEST POINT FOR ALL ROOF STRUCTURES, INCLUDING
 ARCHITECTURAL FEATURES AND CHIMNEY.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q., OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 1 Status N Date 2007-04-19 Cont ID  
Sent By mmclean Date 2006-06-28 Time 11:24 Rev Time 0.00
Received By mmclean Date 2006-06-28 Time 11:24 Sent To E
Notes
2006-06-28 00:00:00NOTE:
 THE PROPOSED A/C SHALL NOT BE CLOSER
 THAN 1FT FROMSIDE PROPERTY LINE.
  
 NOTE: MUST PULL A SEPERATE PEMIT FOR
 POOL/SPA/DECK/SCREEN ENCLOSURE & ALSO A
 FENCE/WALL/GATE WITH EASEMENT APPROVAL
 FROM THE CITY OF WEST PALM BEACH UTILITY
 DEPT.
  