| Plan Review Stops For Permit 06061461 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-20 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-20 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-19 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-19 |
Time |
18:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-19 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-19 |
Time |
18:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-30 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-30 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-30 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-10-27 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-10-27 |
Time |
11:20 |
Sent To |
PC |
|
| Notes |
| 2006-10-27 11:38:31 | | | | | | | DENIED | | | | | | NOTES FROM PREVIOUS REVIEW: | | | | | | 1) OK , IMPACT FEES SHALL BE PAID UPON APPLICATION FOR | | | PERMITTING | | | | | | 2) OK , RADON FEES SHALL BE PAID UPON APPLICATION FOR | | | PERMITTING | | | | | | 3) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS | | | ICC (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS | | | SERVICES PER 108.3 FBC* THIS HAS BEEN CHANGED ON | | | APPLICATION AND IN SYSTEM TO REFLECTNEW ICC BUILDING | | | VALUATION DATA. NEW VALUE $649,850.00 | | | | | | 4) OK | | | | | | 5) OK | | | | | | 6) OK | | | | | | 7) OK | | | | | | 8) OK | | | | | | 9) OK | | | | | | 10) WILL BE PROVISO ON THE PERMIT SET | | | | | | 11) OK | | | | | | 12) REQUIRED AT TIME OF PERMIT APPLICATION | | | | | | NEW REVIEW COMMENTS: | | | | | | 1) REVISED PAGES OF ARCHITECTURAL ARE NOT SIGNED AND | | | SEALED | | | | | | 2) PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN | | | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-06 |
Time |
15:01 |
Rev Time |
3.00 |
| Received By |
amorse |
Date |
2006-07-06 |
Time |
15:01 |
Sent To |
PC |
|
| Notes |
| 2006-07-06 00:00:00 | | | | | | | DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION. | | | | | | 2) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE PER 10D-91 FAC | | | | | | 3) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* | | | | | | 4) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG | | | | | | A) PROVIDE MODIFIED BITUMEN ROOF | | | COVERING PRODUCT APPROVAL FOR FLAT ROOF | | | | | | B) PROVIDE CAST-CRETE PRODUCT APPROVAL | | | | | | C) THERMA TRU FIBERGLASS DOOR IS NOT | | | IMPACT RESISTANT AND WILL REQUIRE | | | OPENING PROTECTIVES | | | | | | D) AMARR GARAGE DOOR HAS NO IMPACT | | | RATING SHOWN IN THE PRODUCT APPROVALS | | | | | | 5) THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 6) PROVIDE AT A MINIMUM ONE BATHROOM ON | | | THE MAIN FLOOR LEVEL WITH A ACCESSABLE | | | DOOR (MIN 29" CLEAR) PER R322.1.1 FBC | | | | | | 7) PROVIDE LINTEL SCHEDULE FOR | | | CAST-CRETE LINTELS WITH LENGTHS USED FOR | | | SPECIFIC DOOR OR WINDOW OPENINGS (MIN 4" | | | END BEARING PER 2104.1.5 FBC) | | | | | | 8) MAKE CORRECTIONS TO ROOF SHEATHING | | | NAIL PATTERN FOR CORNER ZONE 3 PER | | | 2304.9.1 FBC | | | | | | 9) SPIRAL STAIRS SHALL MEET ALL OF THE | | | REQUIREMENTS OF R311.5.8.1 OR 1009.9.3 | | | FBC | | | | | | 10) SUBMIT ENGINEERED TRUSS DRAWINGS | | | THAT COMPLY WITH R802.10.1 FBC WITH | | | PERMIT APPLICATION OR BEFORE | | | INSTALLATION | | | | | | 11) INDICATE TYPE AND VALUE OF WALL AND | | | CEILING INSULATION | | | | | | 12) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | | | | NOTE: | | | FBC = FLORIDA BUILDING CODE 2004 | | | FBC* = WEST PALM BEACH ADMINISTATIVE | | | AMMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-22 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-22 |
Time |
13:17 |
Sent To |
PC |
|
| Notes |
| 2007-12-22 13:22:37 | | | | REDLINED PLANS: | | | | | | SA IN KITCHEN SHALL BE A PHOTO-ELECTRIC EYE OR | | | RE-SETTING TYPE FOR ALL DEVICES LOCATED WITHIN 20FT OF | | | COOKING APPLIANCE. NFPA-72 11.8.3 | | | A LIGTING FIXTURE OF SOME TYPE WILL BE REQUIRED IN | | | HALLWAY AND FOYER BEFORE FINAL. 210.70, LS 101 7.8 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-19 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-19 |
Time |
16:34 |
Sent To |
PC |
|
| Notes |
| 2007-12-19 16:35:20 | ** DENIED REVISION ** | | | | | | | | | 1) NOTE: PLEASE KNOW EVEN AS PLANS ARE NOW UNDER THE | | | RESPONSIBILITY OF THE LICENSED ELECTRICAL CONTRACTOR AS | | | PERMITTED IN FS 471 AND 489, PLEASE BE SURE PLANS | | | CONTAIN THE SIGNATURE OF THE QUALIFIER. | | | FBC 106.1.2, 106.5 ETC | | | | | | 2) NOTE: PLEASE SEE PLANS NOW HAVE RISER COMPLETELY | | | REVISED. PLEASE CLARIFY IF THE NEW SERVICE IS A | | | METER/MAIN COMBO. NO METER SHOWN ON RISER. | | | PLEASE SEE PLANS ON E-2 STILL ACTUALLY SHOW A SEPARATE | | | METER AND SEPARATE MAIN. | | | PLEASE SEE THERE IS NO MENTION OF ANY MAINS OR OVER | | | CURRENT PROTECTION FOR EITHER OF THE 200AMPS SUB | | | PANELS. PLEASE PROVIDE SCHEDULE FOR *ASSUMED* | | | METER/MAIN EQUIPMENT. | | | 230.70, 230.71, 230.72, 240.4 AND 310.16 ETC | | | FBC 106.3.5.4 | | | | | | 3) NOTE: PLEASE KNOW THE NEW SPEAKERS SHOWN ON PLANS | | | WILL BE REQUIRED TO BE UNDER A SEPARATE PERMIT. THESE | | | PLANS MAY BE REFERENCED FOR PERMIT ONCE REVISIONS ARE | | | CORRECTED. | | | ** THIS IS NOTED FOR INFORMATION. | | | | | | 4) NOTE: PLEASE SEE NFPA-72 11.8.3 AS THE SMOKE ALARM | | | IN KITCHEN IS BEING SHOWN WITHIN 20FT OF COOKING | | | APPLIANCE WHICH IS NOT PERMITTED. PLEASE KEEP IN MIND | | | THE EXCEPTION IS THAT THE UNIT INSTALLED MUST BE A | | | *PHOTO-ELECTRIC* RE-SETTING TYPE. | | | ** THIS IS FOR INFORMATION WHICH WILL BE NEEDED BEFORE | | | INSTALLATION OF UNIT AND FINAL. | | | | | | 5) NOTE: PLEASE SEE THE HALLWAY BETWEEN DINING ROOM AND | | | LIVING ROOM WILL REQUIRE A MINIMUM OF ONE LIGHT FIXTURE | | | FOR EGRESS. | | | THIS COULD BE REDLINED AND REVISED BEFORE FINAL OR | | | REVISED SHOWING A FIXTURE OF SOME TYPE AT THIS TIME. | | | THIS ALSO INCLUDES FOYER AREA. | | | 210.70, LS101 7.8 | | | | | | 6) NOTE: PLEASE SEE MISSING * EQUIPMENT GROUNDING | | | CONDUCTORS* AFTER THE FIRST MEANS OF DISCONNECT FOR | | | ALL. | | | PLEASE SEE 250.122 FOR SIZING. | | | 250.24, 250.110 ETC | | | | | | 7) NOTE: PLEASE INCLUDE AIC RATING FOR NEW SERVICE | | | MAINS/EQUIPMENT. | | | 110.9 | | | FBC 106.1.2, 106.3.5.4 | | | | | | ** ITEMS ON SHEETS E-2 & 3 MAY BE ADJUSTED AT THIS | | | TIME, OR MAY BE REDLINED AND REVISED BEFORE FINAL. | | | ITEMS ON SHEET E-4 NEED TO BE CORRECTED AT THIS TIME. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-19 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-13 |
Time |
09:04 |
Sent To |
B |
|
| Notes |
| 2007-04-13 09:51:22 | ** REDLINED NOTES ** | | | | | | * LOADS ON APPLIANCE LOAD SUMMARY STILL DO NOT | | | CORRELATE WITH THE LOAD CALCULATIONS, LOADS ON LOAD | | | CALCULATIONS APPLY. | | | | | | * PANEL "B" STILL SHOWN AS 100AMP RATED AND 42CIR, THIS | | | IS TO VIF. | | | | | | | | | ** ALL REVISIONS ARE TO BE SUBMITTED BEFORE ROUGH | | | ELECRTRICAL INPSECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-02-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-25 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-22 |
Time |
08:52 |
Sent To |
M |
|
| Notes |
| 2007-02-25 08:25:02 | *** UNSAT 3RD REVIEW *** | | | | | | ** PLEASE KNOW THIS IS THE FIRST REVIEW UNDER PERMIT | | | APPLICATION. | | | | | | ** PLEASE SEE THAT THE PREVIOUS SUBMITTED SHEET E-2 IS | | | THE SAME SHEET | | | | | | | | | ** | | | 1) NOTE: PLEASE SEE THAT PERMIT APPLICATION HAS ONLY | | | NOW BEEN MADE AND IT IS AFTER THE NEW CODES HAVE GONE | | | INTO EFFECT. | | | PLEASE BE SURE ALL PLANS REFLECT THE LATEST ADOPTED | | | CODES PER THE STATE OF FLORIDA. PLEASE SEE THE | | | FOLLOWING WHICH ARE CURRENTLY ADOPTED AS OF DECEMBER | | | 8TH, 2006. | | | 2004 FBC W/ 2006 REVISION. (THIS WILL AFFECT PLANS | | | SUBMITTED). | | | 2005 NFPA-70 (NEC). | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | ** THESE CODES ARE REQUIRED AT A MINIMUM FOR THIS TRADE | | | REVIEWER; OTHERS MAY BE REQUIRED PER OTHER TRADES OR | | | REVIEWER(S). | | | PLEASE SEE THERE ARE MANY AREAS ON THE PLANS WHICH | | | REFERENCE OLDER CODES FROM PREVIOUS CODES, THESE SHOULD | | | BE REVISED ACCORDINGLY. | | | | | | 2) NOTE: PLEASE SEE 2004 FBC W/2006 FOR NOTE REQUIRED | | | FOR TYPE OF RECESSED LIGHTING FIXTURES PER | | | 13-606.1.ABC.1.2.4 | | | | | | 3) NOTE: PLEASE SEE DUE TO THE SHEET E-2 BEING THE | | | EXACT SAME SHEET SUBMITTED PREVIOUSLY WITH NO REVISIONS | | | MADE, PLEASE BE SURE TO SEE ALL COMMENTS FROM PREVIOUS | | | REVIEW(S) AND SEE REDLINED PLANS WHICH ARE STILL IN | | | SETS FROM PREVIOUS REVIEW. | | | | | | 4) NOTE: PLEASE SEE LOAD CALCULATIONS SHALL BE DONE AND | | | CODES STATED PER 2005 NEC/ NFPA-70. PLEASE SEE ALL ARE | | | REFLECTED FROM THE 2002 NEC. | | | | | | 5) NOTE:PLEASE SEE DUE TO SOME SHEETS BEING THE SAME | | | SHEETS FROM PREVIOUS REVIEW THIS COMMENT STANDS. | | | PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN | | | SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY | | | INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS | | | ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN | | | THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS | | | OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE | | | ALARMS. | | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. | | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | 6) NOTE: PLEASE SEE PREVIOUS COMMENT WITH RESPECT TO | | | THE NUMBER OF SMALL APPLIANCE CIRCUITS WHICH ARE | | | REQUIRED TO BE FIGURED INTO THE LOAD CALCULATIONS PER | | | 210.52B1, 220.52, 210.11C1. THE ONLY SECTION WHICH WAS | | | DIFFERENT ON PREVIOUS NOTES WAS 220.52 WHICH USED TO BE | | | 220.16. THIS IS THE SAME COMMENT MADE ON PREVIOUS | | | REVIEWS. PLEASE BE SURE TO GO OVER ALL OF THESE TYPES | | | OF CIRCUITS AND REVISE LOAD CALCULATIONS. (NOT ALL ARE | | | INCLUDED AS SHOWN ON PLANS AND PANEL SCHEDULES). | | | | | | 7) NOTE: PLEASE SEE PANEL *B* WHICH IS SHOWN AS 100AMPS | | | AND 42 CIRCUIT. PLEASE VERIFY THIS AS 100AMPS PANELS | | | ARE NOT MADE WITH 42CIRCUITS. | | | PLEASE ALSO SEE PANEL *C* WHICH IS SHOWN AS 20 POLES | | | AND 42 POLES? | | | PLEASE CORRELATE EQUIPMENT. 110.3, 90.7. | | | FBC 106.1.2 ADMIN SECTION. | | | | | | 8) NOTE: PLEASE CLARIFY THE SECTION/DATE STATED ON | | | PLANS WHICH LISTS THE LOAD CALCULATIONS PER A DATE OF | | | 9/25/1997? PLEASE SEE NOTES ABOVE WITH RESPECT TO THE | | | CURRENT CODE OF 2005 NFPA-70. | | | | | | 9) NOTE: PLEASE CORRELATE LOADS SHOWN FOR PANEL *C* ON | | | PANEL *A* SCHEDULE WITH THAT OF THE LOAD SHOWN ON PANEL | | | *C*. | | | 220. | | | FBC 106.1.2 | | | | | | 10) NOTE: PLEASE CORRELATE ALL LOADS ON PANEL SCHEDULES | | | WITH LOADS ON LOAD SUMMARY AND LOADS ON LOADS | | | CALCULATIONS. PLEASE SEE THERE ARE SEVERAL WHICH DO NOT | | | CORRELATE. PLEASE ALSO SEE THAT ALL LOADS ARE PERMITTED | | | TO ROUND UP, BUT NOT PERMITTED TO ROUND DOWN. | | | PLEASE SEE SOME LOADS ARE AS MUCH AS 800VA MORE ON | | | PANEL SCHEDULE THAN IN LOAD CALCULATIONS ETC. | | | PLEASE SEE 2005 NEC 220. | | | FBC 106.1.2, 106.3.5.3.4 | | | | | | 11) NOTE: PLEASE SEE FS 489 PART I AS IT APPEARS PERMIT | | | IS BEING APPLIED FOR AS OWNER/BUILDER YETHOMESTEAD | | | AND RESISIDENCE IS ANOTHER LOCATION. PLEASE KNOW THAT | | | DOCUMENTATION MAY BE REQUIREDFOR O/B IS MOVING INOT | | | NEW RESIDENCE. | | | | | | | | | ** PLEASE BE SURE TO SEE COMMENT S FROM PREVIOUS REVIEW | | | AS SOME MAY STILL APPLY OR CORRELATE WITH THESE PLANS | | | FOR SHEET E-2. | | | | | | ** PLEASE KNOW AS PLANS WERE ONLY SUBMITTED FOR **PLAN | | | REVIEW** THE FIRST TWO TIMES, FS 553.80(2)(B) DOES NOT | | | APPLY. | | | | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-02-25 07:53:59 | 2007-02-25 07:53:59 | | | REVIEW CONTINUED |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-24 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-24 |
Time |
10:41 |
Sent To |
M |
|
| Notes |
| 2006-10-24 12:00:01 | ****** UNSAT2ND REVIEW ******** | | | | | | ** PLEASE KNOW PLANS AHVE ONLY BEEN SUBMITTED FOR "PLAN | | | REVIEW" ONLY AND EVEN IF PLANS PASS THEY CAN NOT BE | | | STAMPED UNTIL SUCH TIME A PERMIT HAS BEEN APPLIED FOR | | | . | | | PLEASE SEE REVIEWS ARE BASED ON PLANS REVIEW FOR A | | | "PROJECT" ONLY. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE THE | | | SAME AND SEE NEW NOTE DUE TO A CHANGE AND INFORMATION | | | FOUND IN THE CODE. | | | PLEASE SEE NOTE BELOW ARE TAKEN DIRECTLY FROM PREVIOUS | | | REVIEW WITH NEW NOTES ADDED. | | | | | | 1) NOTE:OK, HOWEVER PLEASE DO THE SAME WHEN | | | RESUBMITTING PLANS FOR REVIEW ONCE AGAIN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE TO COMPLETELY | | | REMOVE ANY OF THE OLD/VOIDED SHEETS | | | FROM SETS AND ONLY INSERT THE NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | THIS WILL HELP TO AVOID ANY DELAYS IN | | | PROCESSING PROJECT. | | | ** ONE COPY OF ANY OLD/VOIDED REMOVED | | | SHEETS SHOULD BE SUBMITTED SEPARATELY | | | FOR REFERENCE. | | | | | | 2) NOTE:NO, PLEASE SEE LOADS SHALL BE FIGURED FOR ONE | | | OR MORE. PLEASE SEE TWO SM APPL CIRCUITS ARE REQUIRED | | | FOR MIN, HOWEVER PLEASE SEE CODES GIVEN FOR OTHERS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE CIRCUITING FOR | | | BUTLERS PANTRY IS SHOWN ALSO FEEDING | | | OUTSIDE GFI(S). | | | PLEASE SEE 210.52B1 WHICH SPEAKS OF | | | KITCHEN SM APPL AND AREAS OF THE LIKE. | | | BUTLERS PANTRY SHALL BE CIRCUITED TO ONE | | | OR MORE OF THE SMALL APPLICANCE | | | CIRCUITS. | | | LOADS SHALL BE FIGURED AT 1.5KW PER CIR. | | | PLEASE ALSO OTHER CIRCUITS IN KITCHEN | | | WHICH AARE NOT BEING SHOWN WITH LOADS | | | ETC AT 1.5, VA OR ON ON ONE OR MORE OF | | | THE SM APPL CIRCUITS. | | | PLEASE KNOW, ALL CIRCUITS ABOVE THE TWO | | | MIN SM APPL, SHALL ALL BE FIGURED AND | | | SHOWN AT 1.5KW FOR EACH. IE; 4-CIRCUITS, | | | 6KW. | | | 210.11C1,210.52B1,220.16 | | | | | | 3) NOTE:OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK, HOWEVER SEE NEW NOTE WITH RESPECT TO SD'S | | | AND SA'S | | | | | | 7) NOTE: OK, NO ELECTRICAL SHOWN, IF THIS NEEDED, THESE | | | ITEMS WILL BE REQUIRED TO BE REVISED AT A LATER DATE. | | | PLEAS KNOW, MAY GAS APPLIANCES ARE REQUIRED TO HAVE AN | | | ELECTRICAL FEED OF SOME KIND FOR ELECTRONICS ETC. THIS | | | IS NOT ANYTHIGN THAT NEEDS TO BE CORRECTED ON PLANS. | | | | | | 8) NOTE: NO, PLEASE SEE LOAD CALCULATIONS STILL DO NOT | | | INCLUDE ALL LOADS FOR DEDICATED EQUIPMENT. PLEASE SEE | | | LOADS ON PANELS "B" AND "C" STILL DO NOT CORRELATE WITH | | | PANEL "A". PLEASE SEE THERE ARE MANY IEMS WHICH ARE | | | DEDICATED LAODS NOT FIGURED. | | | PLEASE SEE NEC 220.31 AND SHOW ALL LOADS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE LOAD CALCULATIONS | | | SHALL INCLUDE ALL LOADS ON PANEL "B" AND | | | "C". PLEASE SEE LOADS SHOWN FOR PANEL | | | "C" IS ONLY SHOWN AT 5.9KW, YET THE | | | LOADS ON PANEL "C" WAY EXCEED THIS. | | | PLEASE SHOW LOADS ON EACH PANEL, AND | | | INDICATE INDICATE THIS BREAK DOWN FOR | | | EACH IN LOAD CALCUALTIONS. | | | 215.5, 220 | | | | | | 9) NOTE: NO, PLEASE SEE THERE ARE STILL SOME MISSING AS | | | REQUIRED PER 210.52 | | | | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING RECEPTS PER | | | 210.52 MANY OF THESE ARE REDLINED ON ONE | | | OF THE SETS OF PLANS. | | | PLEASE SEE 3RD FLR, IF THIS AREA IS | | | ENCLOSED, RECEPTS WILL BE REQUIRED. | | | PLEASE ALSO SEE BUILDING COMMENTS IF 3 | | | FLRS OF HABITABLE SPACE. | | | | | | 10) NOTE: OK. | | | | | | 11) NOTE: OK. | | | | | | 12) NOTE: NO, PLEASE SEE GUEST RM, MISSING DESIGNATION | | | ON ELECTRICAL PLANS, AND CIRCUITING FOR RECETPS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 408.4 WHERE THE | | | PANEL SCHEDULE SHALL BE SPECIFIC FOR | | | ROOMS AND ALL AREAS. MOST ARE DONE. | | | IE: BEDRM #3 RECEPTS , LIV RM LTS ETC | | | ** IT IS KNOWN, THAT DURING CONSTRUCTION | | | THESE CIRCUITS MAY CHANGE AND CAN BE | | | REVISED AT A LATER DATE. | | | PLEASE SEE SOME ARE ONLY SHOWN AS GFI, | | | ETC. WHEREAS THE SM APPL CIRCUITS ETC | | | SHALL BE SPECIFIC. | | | | | | 13) NOTE: OK. | | | | | | 14) NOTE: OK. | | | | | | 15) NOTE:NO, PLEASE SEE NOT ALL CIRCUITS WHICH | | | REQUIRE AFCI PROTECTION ARE SHOWN THIS WAY. PLEASE SEE | | | A-31AND VERIFY ALL OTHERS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE ARC FAULT | | | PROTECTION IS REQUIRED FOR ALL CIRCUITS | | | IN BEDRMS , NOT ONLY RECEPTS. THIS | | | REQUIREMRNT WAS CHANGED FROM THE 1999 | | | NEC. THE 2002 NEC 210.12B REQUIRES ALL | | | "OUTLETS" TO BE PROTECTED ON THAT BRANCH | | | CIRCUIT. THIS INCLUDES, LTS, RECEPTS, | | | SD'S, FANS ETC. | | | | | | 16)NOTE: OK, HOWEVER WITH THE AIC RATING BEING SHOWN | | | AT 10K, PLEASE KNOW IF THE LOCATION CONTAINS AN OLDER | | | TRANSFORMER, IT IS KNOWN TO THIS OFFICE THAT MANY OF | | | THE OLDER TRANSFORMER ARE BEING CHNAGED OUT AND SOME | | | CONSIDERATION FOR FUTURE KVA SIZE SHOULD BE GIVE. THIS | | | IS ONLY NOTED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 17) NOTE: OK. | | | | | | 18) NOTE:NO, PLEASE SEE MISSING REQUIRED FOOTER | | | STEEL. SHOWS OTHERS, HOWEVER THE FOOTER STEEL IS | | | REQUIRED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 250.50 FOR MIN | | | GROUNDING ELECTRODE SYSTEM AT MAIN | | | HOUSE. NEW FOOTER STEEL, CWP, GRND ROD | | | WILL BE REQUIRED. | | | | | | 19) NOTE:OK. | | | | | | 20) NOTE:NO, AS NOTED ABOVE. PLEASE SEE SOME AREAS | | | ARE MISSING SOME CIRCUITING. SEE REDLINED (GUEST RM). | | | AND OTHER POSSIBLE LOCATIONS. | | | NOT ALL AREAS AS REDLINED | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE SOME ITEMS/RECEPTS | | | ARE MISSING CIRCUITING ON PLANS. THESE | | | ARE MINOR AND HAVE BEEN REDLINED, ALONG | | | WITH SD'S. | | | FBC ADMIN SECT 106.1.2 | | | | | | 21) NOTE:NO, PLEASE SEE NOTE #2 ABOVE. PLEASE SEE | | | LOADS, ECT REQUIRED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THE DINING RM | | | RECEPTS SHALL BE EITHER ON ONE OR MORE | | | OF THE REQUIRED DEDICATED SMA PPL | | | CIRCUITS OR ON THEIR OWN. 210.11C1,220.16,210.52B1 | | | | | | 22) NOTE: OK. | | | | | | 23) NOTE: OK. | | | | | | 24) NOTE: OK, HOWEVER PLEASE SEE BOTH GDO'S (GARAGE | | | DOOR OPENERS) ARE BEING SHOWN ON ONE CIRCUIT WITH A | | | LOAD OF 900A FOR BOTH. PLEASE VERIFY THIS AS THE | | | TYPICAL SIZE OF A GDO IS LARGE ENOUGH WHERE EACH | | | REQUIRES A DEDICATED CIRCUIT. PLEASE SEE 430.148 AND | | | VERIFY AS THIS WOULD BE THE TIME TO REVISE IF NEEDED. | | | PLEASE ALSO REVISED CALCULATIONS IF NEEDED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CLARIFY GDO AS THESE | | | LOCATIONS ARE SHOWING "J" BOXES AND NOT | | | RECEPTS. PLEASE KNOW, IF THE GDO'S ARE | | | PLUG-IN TYPE, THEN RECEPTS SHOULD BE | | | SHOWN. | | | 106.1.2 | | | | | | *** NEW NOTE *** | | | | | | 25) NOTE: PLEASE SEE NFPA-72 2002 DEFINITIONS OF SMOKE | | | DETECTORS AND SMOKE ALARMS. PLEASE ADJUST SYMBOL | | | DESIGNATIONS ON PLANS IF THESE ARE INDEED NOT ONLY | | | DETECTION DEVICES ARE NOTPART OF A FA SYSTEM/SECURITY | | | SYSTEM. IF THESE ARE DEVICES WHICH DETECT AND SOUND | | | THESE ARE CONSIDERED SA'S SMOKE ALARMS. PLEASE KNOW THE | | | CLARIFICATION FROM NFPA AND THE CODE PANELIST WAS GIVEN | | | RECENTLY SINCE THE LAST REVIEW. | | | PLEASE ADJUST PLANS. | | | | | | | | | ** PLEASE KNOW,MANY OF THE ABOVE ITEMS | | | ARE REDLINED ON ONE OF THE SETS OF | | | PLANS, HOWEVER IS IN NO WAY ALL | | | LOCATIONS AS NOTED ABOVE. | | | | | | ** PLEASE SUBMIT THE ABOVE FOR REVIEW | | | AND IF THERE ARE ANY QUESTIONS OR | | | COMMENTS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2006-10-24 10:42:39 | RECEIVED FROM"INCOMING" ON 10/24/06, PLANS WERE NOT | | | ROUTED ON 10/6 TO ELECTRICAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-30 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-30 |
Time |
09:27 |
Sent To |
M |
|
| Notes |
| 2006-06-30 00:00:00 | ****** UNSAT ******** | | | | | | 1) NOTE: PLEASE BE SURE TO COMPLETELY | | | REMOVED ANY OF THE OLD/VOIDED SHEETS | | | FROM SETS AND ONLY INSERT THE NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | THIS WILL HELP TO AVOID ANY DELAYS IN | | | PROCESSING PROJECT. | | | ** ONE COPY OF ANY OLD/VOIDED REMOVED | | | SHEETS SHOULD BE SUBMITTED SEPARATELY | | | FOR REFERENCE. | | | | | | 2) NOTE: PLEASE SEE CIRCUITING FOR | | | BUTLERS PANTRY IS SHOWN ALSO FEEDING | | | OUTSIDE GFI(S). | | | PLEASE SEE 210.52B1 WHICH SPEAKS OF | | | KITCHEN SM APPL AND AREAS OF THE LIKE. | | | BUTLERS PANTRY SHALL BE CIRCUITED TO ONE | | | OR MORE OF THE SMALL APPLICANCE | | | CIRCUITS. | | | LOADS SHALL BE FIGURED AT 1.5KW PER CIR. | | | PLEASE ALSO OTHER CIRCUITS IN KITCHEN | | | WHICH AARE NOT BEING SHOWN WITH LOADS | | | ETC AT 1.5, VA OR ON ON ONE OR MORE OF | | | THE SM APPL CIRCUITS. | | | PLEASE KNOW, ALL CIRCUITS ABOVE THE TWO | | | MIN SM APPL, SHALL ALL BE FIGURED AND | | | SHOWN AT 1.5KW FOR EACH. IE; 4-CIRCUITS, | | | 6KW. | | | 210.11C1,210.52B1,220.16 | | | | | | 3) NOTE: PLEASE SEE PLANS SHALL | | | REFERENCE THE CURRENT CODES IN EFFECT. | | | PLEASE SEE PLANS NOW INDICATE THE | | | "LATEST CODES". WE ARE NOT CURRENTLY | | | UNDER THE LATEST CODES AS THEY HAVE NOT | | | YET BEEN ADOPTED BY THE STATE OF | | | FLORIDA. | | | PLEASE SEE THE FOLLOWING AT A MIN SHOULD | | | BEON PLANS. 2002 NFPA-70, 2003 NFPA-101, | | | 2002 NFPA-72. | | | | | | 4) NOTE: PLEASE SEE MORE THAN ONE | | | ENGINEERING TITLE BLOCK IS BEING SHOWN | | | ON PLANS.??? | | | PLEASE KNOW, ONE SHALL BE THE | | | RESPONSIBLE FIRM. ANY OTHER CONSULTING | | | FIRMS ETC SHALL ALL INDICATE THEIR | | | REQUIRED INFORMATION ON SAID TITLE | | | BLOCKS. FAC 61G15-23.002, FAC | | | 61G1-16.004, FS 471.023, FS 481.219 | | | | | | 5) NOTE: PLEASE SEE MISSING EGRESS | | | LIGHTING CONTROLS IN MANY LOCATIONS. | | | PLEASE SEE ALL RMS IN HOUSE WHICH | | | INDICATE A SW FOR A FAN AND A | | | FAN J-BOX ONLY?? | | | PLEASE KNOW, A LT FIXTURE WILL BE | | | REQUIRED OR 1/2 SWITCHED RECEPT. | | | PLEASE SEE OTHER LOCATIONS IN MAIN HOUSE | | | FOR LOCATIONS OF MEANS OF EGRESS AND | | | WHERE A LT FIXTURE OF SOME SORT WILL BE | | | REQUIRED. PLEASE SEE RMS( BEDRM #1) | | | WHERE ALL THE RECEPTS ARE SHOWN BEING | | | SWITCHED? (AS SHOWN) IF THIS IS INDEED | | | THE CASE, THEN PLEASE ALSO PROVIDE | | | RECEPTS WHICH ARE NOT SWITCHED OR 1/2 | | | SWITCHED TO MEET 210.52 | | | (THIS APPEARS TO BE A MISPRINT). | | | PLEASE SEE EGRESS TO UPPER TOWER FLR | | | DOES NOT INDICATE A "S"3/ LEADING TO THE | | | FLR ABOVE AND UPPER TOWER ONLY SHOWS A | | | "S" FOR LT. | | | | | | 6) NOTE: PLEASE SEE SD'S ARE NOTALL | | | SHOWN WITH CIRCUITING? PLEASE SEE SD'S | | | ARE BEING SHOWN CIRCUITED TO MORE THAN | | | ONE CIRCUIT ON PANELS. | | | PLEASE KNOW, THE SD'S IN DWELLING CAN | | | BE CIRCUITED TO ONE OF THE ARC FAULT | | | PROTECTED BEDRM LIGHTING/RECEPT | | | CIRCUITS. THIS WILL ALLEAVIATE THE | | | TURNING OFF OF THIS CIRCUIT AND LEAVING | | | THE ENTIRE DWELLING WITH OUT SD | | | PROTECTION. ( THIS WOULD ALSO ALLEAVIATE | | | THE ADDITIONAL AFCI BRKR) | | | 215.5 NFPA-72 11.8.3 | | | ** PLEASE SEE 11.8.3 AS STATED ABOVE, | | | MISSING SD WHICH IS REQUIRED INSIDE ALL | | | SLEEPING ROOMS. PLEASE KNOW SD IN BEDRM | | | #1 SHALL BE "IN" THE BEDRM AREA. PLEASE | | | KNOW, SD'S SHALL BE INSTALLED WITH IN 3' | | | OF THE PEAK ON A SLOPED CEILING. | | | PLEASE SEE IF UPPER TOWER/FLR IS CLOSED | | | IN, THEN A SD AT THAT LEVEL WILL BE | | | REQUIRED. | | | PLEASE SEE NO DOORS ARE SHOWN LEADING TO | | | THE FLR BELOW AND IT SEEMS THAT THIS | | | SPACE IS ENCLOSED. | | | | | | 7) NOTE: PLEASE SEE IT IS KNOWN THAT THE | | | RANGE, WH ETC MAY BE GAS , HOWEVER NO | | | ELECTRICAL IS BEING SHOWN TO THESE UNITS | | | FOR IGNITER'S, ETC.?? | | | | | | 8) NOTE:PLEASE SEE LOAD CALCULATIONS | | | SHALL INCLUDE ALL LOADS ON PANEL "B" AND | | | "C". PLEASE SEE LOADS SHOWN FOR PANEL | | | "C" IS ONLY SHOWN AT 5.9KW, YET THE | | | LOADS ON PANEL "C" WAY EXCEED THIS. | | | PLEASE SHOW LOADS ON EACH PANEL, AND | | | INDICATE INDICATE THIS BREAK DOWN FOR | | | EACH IN LOAD CALCUALTIONS. | | | 215.5, 220 | | | | | | 9) NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52 MANY OF THESE ARE REDLINED ON ONE | | | OF THE SETS OF PLANS. | | | PLEASE SEE 3RD FLR, IF THIS AREA IS | | | INCLOSED, RECEPTS WILL BE REQUIRED. | | | PLEASE ALSO SEE BUILDING COMMENTS IF 3 | | | FLRS OF HABITABLE SPACE. | | | | | | 10) NOTE: PLEASE SEE SOME CIRCUITS ARE | | | NOTED SHOWING GFI RECEPTS AND ALSO GFI | | | BREAKERS IN PANELS?? | | | THIS IS OK, HOWEVER IF SHOWN THIS WAY, | | | THEN THIS WILL BE REQUIRED. | | | **THIS IS ONLY A NOTE; | | | | | | 11) NOTE: PLEASE CORRELATE FEEDER TO | | | PANEL "C" WITH PANEL "A" SCHEDULE. 310.16,240.4,215.5 | | | | | | 12) NOTE: PLEASE SEE 408.4 WHERE THE | | | PANEL SCHEDULE SHALL BE SPECIFIC FOR | | | ROOMS AND ALL AREAS. MOST ARE DONE. | | | IE: BEDRM #3 RECEPTS , LIV RM LTS ETC | | | ** IT IS KNOWN, THAT DURING CONSTRUCTION | | | THESE CIRCUITS MAY CHANGE AND CAN BE | | | REVISED AT A LATER DATE. | | | PLEASE SEE SOME ARE ONLY SHOWN AS GFI, | | | ETC. WHEREAS THE SM APPL CIRCUITS ETC | | | SHALL BE SPECIFIC. | | | | | | 13) NOTE: PLEASE INDICATE TH GFI | | | PROTECTION FOR THE JACUZZI TUB. | | | 210.8,680.71 | | | | | | 14) NOTE: PLEASE INDICATE TH RM WHERE | | | THE AHU #2 AS MECH/ELEC RM. NO STORAGE | | | PERMITTED. | | | 110.26,408.7,240.24 | | | | | | 15) NOTE: PLEASE SEE ARC FAULT | | | PROTECTION IS REQUIRED FOR ALL CIRCUITS | | | IN BEDRMS , NOT ONLY RECEPTS. THIS | | | REQUIREMRNT WAS CHANGED FROM THE 1999 | | | NEC. THE 2002 NEC 210.12B REQUIRES ALL | | | "OUTLETS" TO BE PROTECTED ON THAT BRANCH | | | CIRCUIT. THIS INCLUDES, LTS, RECEPTS, | | | SD'S, FANS ETC. | | | | | | 16)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 17) NOTE: PLEASE SEE RISER IS SHOWING | | | "EQUIPMENT GROUNDING CONDUCTORS" FROM | | | METER TO MAINS. PLEASE SEE THE EQP GRNDS | | | ARE ONLY INSTALLED AFTER THE FIRST MEANS | | | OF DISCONNECT. | | | 250.6,250.24B | | | | | | 18) NOTE: PLEASE SEE 250.50 FOR MIN | | | GROUNDING ELECTRODE SYSTEM AT MAIN | | | HOUSE. NEW FOOTER STEEL, CWP, GRND ROD | | | WILL BE REQUIRED. | | | | | | 19) NOTE: PLEASE SEE NO HAND DRAWN | | | CHANGES AREPERMITTED ON PLANS WHICH | | | ARE SIGNED, DATED AND SEALED BY THE | | | ARCHITECT OR ENGINEER. | | | FS 481.221, 471.025 | | | PLEASE KNOW, "IF" SOME VERY MINOR ITEMS | | | ARE ADDED, THEN EACH ITEM MAY BE DONE | | | WITH THE DESIGN PROFESSIONAL OF RECORD | | | SIGNING AND DATING EACH ITEM. | | | | | | 20) NOTE: PLEASE SEE SOME ITEMS/RECEPTS | | | ARE MISSING CIRCUITING ON PLANS. THESE | | | ARE MINOR AND HAVE BEEN REDLINED, ALONG | | | WITH SD'S. | | | FBC ADMIN SECT 106.1.2 | | | | | | 21) NOTE: PLEASE SEE THE DINING RM | | | RECEPTS SHALL BE EITHER ON ONE OR MORE | | | OF THE REQUIRED DEDICATED SMA PPL | | | CIRCUITS OR ON THEIR OWN. 210.11C1,220.16,210.52B1 | | | | | | 22) NOTE: PLEASE GO THROUGH ALL SWITCHES | | | ON PLANS AS SOME ARE SHOWN AS SINGLE | | | POLE SWITCHES, YET THEY SHOULD BEBUT | | | NOT GOING TO ANYTHING, OTHERS SHOULD BE | | | 3-WAY, BUT NOT CLEAR? SEE NOTE ABOVE. | | | | | | 23) NOTE: PLEASE CORRLELATE ALL A/C | | | SYSTEMS, OCP AND LOADS, AS THESE SHOWN | | | ON ELECTRICAL PANEL SCHEDULE DO NOT | | | MATCH WITH THOSE AS SHOWN ON MECH | | | SHEETS. | | | | | | 24) NOTE: PLEASE CLARIFY GDO AS THESE | | | LOCATIONS ARE SHOWING "J" BOXES AND NOT | | | RECEPTS. PLEASE KNOW, IF THE GDO'S ARE | | | PLUG-IN TYPE, THEN RECEPTS SHOULD BE | | | SHOWN. | | | 106.1.2 | | | | | | ** PLEASE KNOW,MANY OF THE ABOVE ITEMS | | | ARE REDLINED ON ONE OF THE SETS OF | | | PLANS, HOWEVER IS IN NO WAY ALL | | | LOCATIONS AS NOTED ABOVE. | | | | | | ** PLEASE SUBMIT THE ABOVE FOR REVIEW | | | AND IF THERE ARE ANY QUESTIONS OR | | | COMMENTS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-20 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-19 |
Time |
18:45 |
Sent To |
|
|
| Notes |
| 2007-04-19 18:48:24 | GAS REVIEWS WERE NEVER PASSED , SEPERATE GAS PERMIT IS | | | REQUIRED WITH COMPLETE PLANS TO BE SUBMITTED FOR REVIEW | | | AND APPROVAL BEFORE INSTALLATION. | | | | | | | | | | | | | | | L.MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-27 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-27 |
Time |
08:02 |
Sent To |
P |
|
| Notes |
| 2007-02-27 08:22:56 | DENIED; | | | 1.P.E. PIPE CAN ONLY BE USED OUT SIDE OF THE HOUSE. SEE | | | FBC-2004 FUEL GAS SECTION 404.14.1 | | | 2. LIST THE OTHER PIPE MATERIALS TO BE USED INSIDE THE | | | HOUSE AND LIST TABLES TO BE USED. | | | 3. LIST SIZE OF SLEEVES TO BE USED AND TYPE OF | | | MATERIAL. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-27 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-27 |
Time |
08:30 |
Sent To |
B |
|
| Notes |
| 2006-10-27 08:41:10 | DENIED; | | | 1. INDICATE PIPE MATERIAL USED IN HOUSE. | | | 2. GAS PIPE UNDER SLAB SHALL BE SLEEVED WITH A VENT TO | | | THE OUTSIDE. FBC-2004 FUEL GAS SECTION 404.11. | | | 3.LIST SIZING TABLES USED SEE FBC-2004 FUEL GAS; | | | METALLIC PIPE 402.4 (2) | | | CORRUGATED STAINLESS STEEL TUBING 402.4 | | | (14) | | | POLYETHYLINE PIPE 402.4 (20) | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-06 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-06 |
Time |
08:59 |
Sent To |
B |
|
| Notes |
| 2006-07-06 00:00:00 | DENIED; | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | 3. TYPE OF GAS, (LP OR NATURAL) | | | 4. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | GAS REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-20 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-12-20 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2007-12-20 17:14:02 | ROUTED TO DEWEY PALMER'S DESK MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-14 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-14 |
Time |
13:22 |
Sent To |
E |
|
| Notes |
| 2007-12-14 13:22:27 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
10:25 |
Sent To |
M |
|
| Notes |
| 2007-12-13 10:25:50 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
14:23 |
Sent To |
M |
|
| Notes |
| 2007-11-16 14:23:42 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-26 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-26 |
Time |
11:40 |
Sent To |
B |
|
| Notes |
| 2007-07-26 11:41:03 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-17 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-17 |
Time |
09:05 |
Sent To |
B |
|
| Notes |
| 2007-07-17 09:06:12 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-04 |
Time |
17:46 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-04 |
Time |
17:46 |
Sent To |
Z |
|
| Notes |
| 2007-04-04 17:47:03 | TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-20 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-20 |
Time |
15:05 |
Sent To |
E |
|
| Notes |
| 2007-02-20 15:05:45 | TO "DPALMER" DESK/PROJECT TO PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-05 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-05 |
Time |
16:29 |
Sent To |
Z |
|
| Notes |
| 2007-02-05 16:29:44 | TO "Z" BOX/RESUB--PROJECT TO PERMIT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-24 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-06 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2006-10-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-27 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-13 |
Time |
12:02 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-12-13 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2007-12-13 12:03:01 | REVISION TO MEDCH. PLANS PAGES M1 OF 2 AND M2 OF 2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-29 |
Time |
10:48 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-11-29 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2007-11-29 10:49:39 | REVISION TO MECH. PLANS AND ENERGY CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-26 |
Time |
09:19 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-02-26 |
Time |
09:19 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-10-24 |
Time |
15:54 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-10-24 |
Time |
15:54 |
Sent To |
P |
|
| Notes |
| 2006-10-24 16:01:13 | ** FOR PLAN REVIEW ONLY NOT FOR PERMIT ** | | | | | | 1) MECHANICAL PLANS WILL BE ABLE TO PASS REVIEW AFTER | | | #2 CORRECTION. | | | | | | 2) PLEASE SHOW ON REAL FYRE BOOKLET WHICH GAS BURNER | | | SYSTEM IS TO BE INSTALLED IN FIRE PLACE WHEN SUBMITTING | | | FOR PERMIT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-30 |
Time |
15:46 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-06-30 |
Time |
15:45 |
Sent To |
P |
|
| Notes |
| 2006-06-30 00:00:00 | FOR PLAN REVIEW ONLY NOT FOR PERMIT. | | | *** DENIED *** | | | 1) PLEASE SUBMIT A COMPLETE MANUAL J | | | CALCULATION SHOWING EACH ZONE, PER 2004 | | | FBC 13-607.1.ABC.1 . | | | | | | 2) SHOW A/C SYSTEMS TOTAL, AND SENSIBLE | | | BTU'S ON MECHANICAL PLANS EQUIPMENT | | | LISTING. | | | | | | 3) PLEASE SUBMIT DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR GAS FIREPLACE & HEATER, | | | AND GAS BBQ GRILL & HOOD. | | | | | | 4) GUEST BEDROOM SHOWS A 10X10 SUPPLY | | | AIR DUCT WITCH MAKES THE 10" RETURN AIR | | | TRANSFER DUCT TO SMALL, PLEASE CORRECT. | | | | | | 5) 12" RETURN AIR TRANSFER DUCT IN | | | MASTER BEDROOM SUITE NEEDS TO BE 14", | | | PLEASE SEE 2004 FBC/R M1602.4 . | | | | | | 6) AHU #2 14X12 RETURN AIR DUCT NEEDS TO | | | BE 26X12, AS IT IS ACTING AS A TRANSFER | | | DUCT, SEE 2004 FBC/R M1602.4 . | | | | | | 7) AHU #2 10X10 RETURN AIR DUCT NEEDS TO | | | BE 16X10 FOR SAME REASON AS NOTE #6. | | | | | | 8) PLEASE SEE ELECTRICAL REWIEW NOTES | | | #3, 4, AND 23. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-27 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-27 |
Time |
08:36 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-27 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-27 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2006-10-27 08:29:37 | PLUMBING PLAN IS TO CODE. WHEN WHEN PERMIT APPLICATION | | | IS SUBMITED PLUMBING PLAN WILL BE STAMPED | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-06 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-06 |
Time |
08:50 |
Sent To |
G |
|
| Notes |
| 2006-07-06 00:00:00 | DENIED; | | | 1.WATER DIAGRAM; WATER HAMMER ARRESTORS | | | ARE REQUIRED WHERE QUICK CLOSING VALVES | | | ARE INSTALLED @ W/M, REFIG., AND D/W'S. | | | 2.AUTOMATIC CLOTHES WASHER BRANCH DRAIN | | | REQUIRED TO BE 3" SEC.406.3. CLEANOUT TO | | | BE INSTALLED AT 48" AFF. | | | 3.SHOW TERMAL EXPANTION CONTROL METHOD | | | PER. SEC.607.3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-04-16 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-04-16 |
Time |
13:55 |
Sent To |
B |
|
| Notes |
| 2007-04-16 16:32:26 | PLANNING AND ZONING DEPARTMENT | | | | | | ***PASSED*** | | | | | | PROVISO THE PROPOSED A/C SHALL NOT BE CLOSER THAN ONE | | | (1) FOOT FROM THE WEST SIDE PROPERTY LINE. | | | | | | MUST PULL A SEPARATE PERMIT FOR POOL/SPA/DECK/SCREEN | | | ENCLOSURE AND ALSO A FENCE/WALL/GATE PERMIT WITH | | | EASEMENT APPROVAL FROM THE CITY OF WEST PALM BEACH | | | PUBLIC UTILITIES DEPARTMENT. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-04-06 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-04-06 |
Time |
15:15 |
Sent To |
I |
|
| Notes |
| 2007-04-06 15:19:14 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1.ACCORDING TO THE PLANS, THE TOP OF PARAPET WILL BE | | | 3 FEET FROM TOP OF SLAB.HOWEVER, MEASURED, THE TOP OF | | | PARAPET WILL BE 2 FEET 6 INCHES FROM TOP OF SLAB. | | | PLEASE CORRECT BUILDING HEIGHT DIMENSIONS ON | | | ELEVATIONS. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-02-16 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-02-16 |
Time |
11:23 |
Sent To |
I |
|
| Notes |
| 2007-02-16 11:36:05 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. PER ARTICLE XIX, DEFINITIONS, OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, BUILDING HEIGHT MEANS THE | | | VERTICAL DISTANCE FROM THE MEAN GRADE OF A LOT AT THE | | | FRONTAGE OF THE BUILDING TO THE HIGHEST POINT OF THE | | | TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK | | | LINE OF A MANSARD ROOF, OR TO THE MID-HEIGHT LEVEL | | | BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL | | | ROOFS. | | | A. PROPOSED RESIDENTIAL STRUCTURE EXCEEDS THE PERMITTED | | | BUILDING HEIGHT PER THE SINGLE FAMILY HIGH DENSITY | | | (SF14) RESIDENTIAL ZONING REGULATIONS (30 FEET), AS | | | PLANS SHOW BUILDING HEIGHT MEASURED FROM THE FINISHED | | | FLOOR. | | | | | | 3. PER SECTION 94-306, HEIGHT EXCEPTIONS, OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, HEATING, VENTILATION | | | AND AIR CONDITIONING EQUIPMENT, CHURCH STEEPLES, BELL | | | TOWERS, FLAG POLES, CHIMNEYS, PARAPETS, STAIR | | | ENCLOSURES, TANKS, DECORATIVE FEATURES, ELEVATOR | | | HOISTWAYS OR EQUIPMENT, TELEVISION OR RADIO ANTENNAS, | | | AND RELATED MECHANICAL OR FUNCTIONAL FEATURES, MAY | | | EXCEED DISTRICT HEIGHT BY TEN (10) PERCENT. | | | A. THE PARAPET, DECORATIVE FEATURES, AND CAST STONE | | | URNS ON THE PROPOSED TOWER EXCEED THE BUILDING HEIGHT | | | EXCEPTION OF 3 FEET (10 PERCENT). | | | | | | 4. PLEASE PROVIDE ELEVATION HEIGHT TO THE | | | HIGHEST POINT FOR ALL ROOF STRUCTURES, INCLUDING | | | ARCHITECTURAL FEATURES AND CHIMNEY. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q., OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-28 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-28 |
Time |
11:24 |
Sent To |
E |
|
| Notes |
| 2006-06-28 00:00:00 | NOTE: | | | THE PROPOSED A/C SHALL NOT BE CLOSER | | | THAN 1FT FROMSIDE PROPERTY LINE. | | | | | | NOTE: MUST PULL A SEPERATE PEMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE & ALSO A | | | FENCE/WALL/GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM BEACH UTILITY | | | DEPT. | | | |
|
|