| Plan Review Stops For Permit 06061421 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-14 |
Time |
10:31 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-07-14 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-05 |
Time |
08:34 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-05 |
Time |
07:34 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-07 |
Time |
07:17 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-03-07 |
Time |
06:58 |
Sent To |
PC |
|
| Notes |
| 2007-03-07 07:17:54 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PROVIDE A LOAD CALCULATION FOR THE | | | LOAD INTENDED TO BE SERVED. 215.5. THE CALCULATIONS | | | SUBMITTED EXCEED THE GENERATOR OUTPUT, SEE 702.5 2005 | | | NEC. | | | | | | 2} PROVIDE A PANEL SCHEDULE FOR THE | | | GENERATOR PANEL. 106.3.5.4 FBC AS | | | AMMENDED. 215.5 NEC | | | | | | 3} THE RISER SHOWS A 25 KW GENERATOR, THE SPEC'S FOR A | | | 20 KW WERE SUBMITTED, PLEASE CORRELATE. | | | | | | 4} PLEASE HI-LITE THE TRANSFER SWITCH INTENDED FOR | | | INSTALLATION ON THE SPEC SHEET SUBMITTED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-05 |
Time |
17:28 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-01-05 |
Time |
17:22 |
Sent To |
G |
|
| Notes |
| 2007-01-05 17:27:54 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT | | | ON A SITE PLAN, METER ENCLOSURE, | | | DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | | BE REVIEWED. | | | | | | 2} PROVIDE MANUFACTURERS SPECIFICATIONS/RECOMMENDATION, | | | REGARDING CLEARANCES. | | | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | | THEIR NAME ON THE SHEETS THEY DRAW. | | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561) 805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-07 |
Time |
07:50 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-07 |
Time |
07:26 |
Sent To |
P |
|
| Notes |
| 2006-07-07 00:00:00 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT | | | ON A SITE PLAN, METER ENCLOSURE, | | | DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | | BE REVIEWED. | | | | | | 2} THERE MUST BE A DISCONNECT FROM THE | | | GENERATOR WHERE THE CONDUCTORS ENTER THE | | | BUILDING GROUPED PER 230.72, SEE THAT | | | ALLARTICLES FROM 225.31 THROUGH 225.39, | | | ARE COMPLIED WITH. | | | | | | 3} PROVIDE MANUFACTURERS SPECIFICATIONS/RECOMMENDATION, | | | REGARDING CLEARANCES. | | | | | | 4} HOW IS THE ATS PROTECTED? | | | | | | 5} THE ATS IS POSITIONED AS PART OF THE | | | SERVICE EQUIPMENT PER THE RISER DIAGRAM. | | | PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 6} THE PERSON TAKING RESPONSIBILITY FOR | | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | | THEIR NAME ON THE SHEETS THEY DRAW. | | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561) 805-6718 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-07 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-08-07 |
Time |
13:56 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 14:02:56 | REVISION: CHANGE LOCATION OF GENERATOR STUBOUT AND | | | LONGES RUN CHANGED. REFERENCE GAS PERMIT #06070423. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-07-07 |
Time |
14:34 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-07-07 |
Time |
14:34 |
Sent To |
M |
|
| Notes |
| 2006-07-07 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-29 |
Time |
09:00 |
Sent To |
E |
|
| Notes |
| 2007-03-29 09:01:02 | TO BT'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-27 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-27 |
Time |
11:31 |
Sent To |
E |
|
| Notes |
| 2007-02-27 11:31:49 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-14 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-14 |
Time |
14:52 |
Sent To |
E |
|
| Notes |
| 2006-11-14 14:52:58 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-05 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-05 |
Time |
11:20 |
Sent To |
E |
|
| Notes |
| 2006-07-05 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-14 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-26 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2006-06-26 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-11 |
Time |
11:07 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-07-11 |
Time |
11:07 |
Sent To |
B |
|
| Notes |
| 2006-07-11 00:00:00 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | PROVIDE MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AT THE JOBSITE FOR THE | | | FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-02 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-02 |
Time |
17:47 |
Sent To |
I |
|
| Notes |
| 2006-07-02 00:00:00 | NOTE: | | | THE PROPOSED GENERATOR SHALL NOT BE | | | CLOSER THAN 9FT FROM REAR PROPERTY LINE | | | AND 1FT FROM THE SIDE SETBACK. |
|
|