| Plan Review Stops For Permit 06061338 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-11-07 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-11-07 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2006-11-07 08:47:51 | PERMIT ASSIGNE DTO THE CORRECT UNIT : 800 |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-06-29 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-06-29 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | EXT #0010 WAS CREATED FOR UNIT 702 UNDER | | | THE MAIN PCN = 74434317050010042 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-11-26 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-11-26 |
Time |
15:16 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-04 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-04 |
Time |
09:56 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-31 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-31 |
Time |
05:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-19 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-19 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2007-03-19 14:39:23 | BUILDING PLAN REVIEW | | | PERMIT: 06061338 | | | ADD: 1401 FORUM PLACE #800 | | | CONT:AZ BUILDERS INC. | | | TEL: (305)986-7035 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 4TH | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)FBC 106.1SUBMIT TWO COMPLETE SETS OF DRAWINGS FOR | | | PLAN REVIEW.ONLY ONE NEW COMPLETE SET WAS SUBMITTED | | | WITH WITH THE OLD SETS. | | | | | | NOTE: THEISSUES FROM THE PREVIOUS REVIEW WERE | | | ADDRESSED, HOWEVER, WE NEED TWO COMPLETE SETS OF PLANS | | | FOR REVIEW AND BEFORE A PERMIT CAN BE ISSUED. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-02-22 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-02-22 |
Time |
05:59 |
Sent To |
|
|
| Notes |
| 2007-02-22 10:45:22 | BUILDING PLAN REVIEW | | | PERMIT: 06061338 | | | ADD: 1401 FORUM PL.#800 | | | CONT:AZ BUILDERS, INC. | | | TEL: (561)986-7035 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 4TH | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)106.1.1CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISION OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL. THE DEMOLITION PLAN SHEET A-2 | | | DOES NOT SHOW A CORRIDOR BETWEEN STAIR #1 AND #2. | | | HOWEVER, SHEET A-4 SHOWS AN EXISTING CORRIDOR WITH THE | | | WALLS EXISTING. | | | | | | 3)DOOR 'M' ON SHEET A-4 WAS CHANGED TO COMPLY WITH | | | SEC. 11-4.13.6, HOWEVER SEE SHEETS A-5 / E-1/ E-2 / | | | AC-1 / F-1 WHERE THE SWING OF DOOR 'M' SWINGS IN THE | | | OPPOSITE DIRECTION. THE FLOOR LAYOUT ON THESE PAGES | | | SHALL MATCH EACH OTHER. | | | | | | 4)F.S.481.221(2)ALL FINAL CONSTRUCTION DOCUMENTS | | | AND INSTRUMENTS OF SERVICE WHICH INCLUDE DRAWINGS, | | | PLANS, SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY | | | THE REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC | | | RECORD AND SHALL BEAR THE SIGNATURE AND SEAL OF THE | | | REGISTERED ARCHITECT WHO PREPARED OR APPROVED THE | | | DOCUMENT AND THE 'DATE' ON WHICH THEY WERE SEALED. THE | | | SIGNATURE, DATE, AND SEAL SHALL BE EVIDENCE OF THE | | | AUTHENTICITY OF THAT TO WHICH THEY ARE AFFIXED. SEE | | | SHEETS A-3 AND A-4. WHICH ARE NOT DATED. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-12-08 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-12-07 |
Time |
18:09 |
Sent To |
|
|
| Notes |
| 2006-12-08 09:53:01 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 3RD | | | ACTION: DENIED | | | | | | 1)FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) SHEET A-3 FBC. 11-4.13.6.MINIMUM MANEUVERING | | | CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN FIGURE 11-25. THE | | | MINIMUM CLERANCE ON THE PULL SIDE IS 18 INCHES AND 12 | | | INCHES ON THE PUSH SIDE. AGAIN SEE FIG. 25 IN CH. 11. | | | | | | 3)AS REQUESTED PREVIOUSLY, SUBMIT A DETAIL ELEVATION | | | DRAWING OF THE RECEPTION COUNTER SHOWING HOW IT WILL | | | MEET THE REQUIREMENTS OF 11-7 (2) WHICH STATES; "OTHER | | | COUNTERS THAT MAY "NOT" HAVE CASH REGISTER BUT AT WHICH | | | GOODS OR SERVICES ARE SOLD OR DISTRIBUTED, EITHER ETC. | | | THE COUNTER SHALL MEET ONE OF THE REQUIREMENTS OF THIS | | | SECTION. | | | | | | 4)AGAIN, THE ENGINEERING INFORMATIONFOR THE | | | RREMOVAL OF THE STAIRS REQUIRES AN INDEX SHEET | | | REFERENCING ALL TO OTHER PAGES OF THE REPORT OR EACH | | | SHEET SHALL HAVE THE ORIGINAL SEAL,SIGNATURE AND DATE | | | OF THE ENGINEER, PHOTO COPIES ARE NOT ACCEPTABLE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-08-14 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-08-11 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | | | | | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) 61G15-23.002 SEAL, SIGNATURE AND DATE | | | SHALL BE AFFIXED. | | | (1) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME AND AFFIX HIS SEAL TO ALL | | | PLANS, SPECIFICATIONS, REPORTS, FINAL | | | BID DOCUMENTS PROVIDED TO THE OWNER OR | | | THE OWNER'S REPRESENTATIVE, OR OTHER | | | DOCUMENTS PREPARED OR ISSUED BY SAID | | | REGISTRANT AND BEING FILED FOR PUBLIC | | | RECORD. THE DATE THAT THE SIGNATURE AND | | | SEAL IS AFFIXED AS PROVIDED HEREIN SHALL | | | BE ENTERED ON SAID PLANS, | | | SPECIFICATIONS,REPORTS, OR OTHER | | | DOCUMENTS IMMEDIATELY UNDER THE | | | SIGNATURE OF THE PROFESSIONAL ENGINEER. | | | (2) EACH SHEET OF PLANS AND PRINTS | | | WHICH MUST BE SEALED UNDER THE | | | PROVISIONS OF CHAPTER 471, F.S., SHALL | | | BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER IN RESPONSIBLE | | | CHARGE. ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS, AND LICENSE NUMBER | | | ON EACH SHEET. | | | (SEE SHEET A-3) | | | | | | 3) OK. | | | | | | 4) OK. PER SHEET P-4 | | | | | | 5) OK. | | | | | | 6) OK. | | | | | | 7) 11-7.2 SALES AND SERVICE COUNTERS , | | | TELLER WINDOWS, INFORMATION COUNTERS. | | | (2) AT TICKETING COUNTERS , TELLER | | | STATIONS IN A BANK, REGISTRATION | | | COUNTERS IN HOTELS AND MOTELS, BOX | | | OFFICE TICKET COUNTERS , AND OTHER | | | COUNTERS THAT MAY NOT HAVE A CASH | | | REGISTER BUT AT WHICH GOODS OR SERVICES | | | ARE SOLD OR DISTRIBUTED, EITHER: | | | (I) A PORTION OF THE MAIN COUNTER WHICH | | | IS A MINIMUM OF 36 INCHES (915 MM) IN | | | LENGTH SHALL BE PROVIDED WITH A MAXIMUM | | | HEIGHT OF 36 INCHES (915 MM);OR | | | (II) AN AUXILIARY COUNTER WITH A | | | MIXIMUM HEIGHT OF 36" IN CLOSE PROXIMITY | | | TO THE MAIN COUNTER SHALL BE | | | PROVIDED.SUBMIT A DETAIL ELEVATION | | | DRAWING OF THE RECEPTION COUNTER SHOWING | | | HOW THE ACCESSIBILITY REQUIREMENTS WILL | | | BE MET. ALL BUSINESS AND SHALL MEET THE | | | REQUIREMENTS OFSECTION 11-7. | | | SUBMIT A DETAIL ELEVATION DRAWING OF THE | | | RECEPTION COUNTER SHOWING HOW THE | | | COUNTER WILL MEET THE ACCESSIBILITY | | | REQUIREMENTS WITHOUT GOING INTO THE WORK | | | AREA OF THE RECEPTIONIST. | | | | | | 8)2004 EXISTING BUILDING CODE 605.2 THE | | | MEANS OF EGRESS SHALL COMPLY WITH THE | | | REQUIREMENTS OF THIS SECTION. | | | EXCEPTIONS: | | | 1. WHERE THE WORK AREA AND THE MEANS OF | | | EGRESS SERVING IT COMPLIES WITH THE | | | FLORIDA FIRE PREVENTION CODE . | | | 2. MEANS OF EGRESS CONFORMING TO THE | | | REQUIREMENTS OF THE FLORIDA BUILDING | | | CODE, BUILDING AND THE FLORIDA FIRE | | | PREVENTION CODE UNDER WHICH THE BUILDING | | | WAS CONSTRUCTED SHALL BE CONSIDERED | | | COMPLIANT MEANS OF EGRESS IF, IN THE | | | OPINION OF THE CODE OFFICIAL, THEY DO | | | NOT CONSTITUTE A DISTINCT HAZARD TO | | | LIFE. {EXIT | | | STAIRWAYS,CHUTES,JANITORCLOSETS, GUEST | | | ROOMS, SERVICE ROOMS, ETC., SHALL NOT | | | OPEN INTO THE ELEVATOR LOBBY.[1982 | | | STANDARD BUILDING CODE SEC.506.6 (1)} | | | NOTE: THE MECH.ROOM AND BOTH EXIT | | | STAIRWAYS OPEN INTO THE ELEVATOR LOBBY. | | | NOTE: THIS BUILDING WAS CONSTRUCTED | | | DURING THE 1982 BUILDING CODE PERIOD. | | | | | | 9) OK. | | | | | | 10) OK. | | | | | | 11) THE ENGINEERING INFORMATION FOR THE | | | REMOVAL OF THE STAIRS REQUIRES AN INDEX | | | SHEET REFERING TO PAGES INCLUDED IN THE | | | PACKAGE, OR EACH SHEET SHALL HAVE THE | | | ORIGINAL SEAL, SIGNATURE AND DATE OF THE | | | ENGINEER. PHOTO COPIES ARE NOT | | | ACCEPTABLE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-07-11 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-07-10 |
Time |
07:22 |
Sent To |
PC |
|
| Notes |
| 2006-07-10 00:00:00 | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) 61G15-23.002 SEAL, SIGNATURE AND DATE | | | SHALL BE AFFIXED. | | | (1) A PROFESSIONAL ENGINEER SHALL SIGN | | | HIS NAME AND AFFIX HIS SEAL TO ALL | | | PLANS, SPECIFICATIONS, REPORTS, FINAL | | | BID DOCUMENTS PROVIDED TO THE OWNER OR | | | THE OWNER'S REPRESENTATIVE, OR OTHER | | | DOCUMENTS PREPARED OR ISSUED BY SAID | | | REGISTRANT AND BEING FILED FOR | | | PUBLIC RECORD. THE DATE THAT THE | | | SIGNATURE AND SEAL IS AFFIXED AS | | | PROVIDED HEREIN SHALL BE ENTERED ON SAID | | | PLANS, SPECIFICATIONS, | | | REPORTS, OR OTHER DOCUMENTS IMMEDIATELY | | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | | ENGINEER. | | | (2) EACH SHEET OF PLANS AND PRINTS | | | WHICH MUST BE SEALED UNDER THE | | | PROVISIONS OF CHAPTER 471, F.S., SHALL | | | BE SEALED, SIGNED AND DATED BY THE | | | PROFESSIONAL ENGINEER IN RESPONSIBLE | | | CHARGE. ENGINEERS SHALL LEGIBLY INDICATE | | | THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET. | | | | | | 3) NFPA 99C5.1.3.3.2 | | | DESIGN AND CONSTRUCTION. LOCATIONS FOR | | | CENTRAL SUPPLY SYSTEMS AND THE STORAGE | | | OF POSITIVE PRESSURE GASES SHALL MEET | | | THE FOLLOWING REQUIREMENTS: | | | (1)BE CONSTRUCTED WITH ACCESS TO | | | MOVE CYLINDERS, EQUIPMENT, AND SO FORTH, | | | IN AND OUT OF THE LOCATION ON HAND | | | TRUCKS COMPLYING WITH 9.5.3.1.1 | | | (2)BE SECURED WITH LOCKABLE DOORS OR | | | GATES OR OTHERWISE SECURED | | | (3)IF OUTDOORS, BE PROVIDED WITH AN | | | ENCLOSURE (WALL OR FENCING) CONSTRUCTED | | | OF NONCOMBUSTIBLE MATERIALS | | | (4)IF INDOORS, BE CONSTRUCTED AND | | | USE INTERIOR FINISHES OF NONCOMBUSTIBLE | | | OR LIMITED-COMBUSTIBLE MATERIALS SUCH | | | THAT ALL WALLS, FLOORS, CEILINGS AND | | | DOORS ARE OF A MINIMUM 1-HOUR FIRE | | | RESISTANCE RATING | | | | | | 4) CONSTRUCTION. CARTS AND HAND TRUCKS | | | FOR CYLINDERS AND CONTAINERS SHALL BE | | | APPROPRIATE CONSTRUCTED FOR THE INTENDED | | | PURPOSE, BE SELF-SUPPORTING, AND BE | | | PROVIDED WITH 9.5.3.1.1 CHAINS OR STAYS | | | TO RETAIN CYLINDERS OR CONTAINERS | | | | | | 5) A.5.1.3.3.2 ELECTRIC WIRING AND | | | EQUIPMENT IN STORAGE ROOMS FOR OXYGEN | | | AND NITROUS OXIDE ARE NOT REQUIRED TO BE | | | EXPLOSION PROOF. | | | | | | 6) A.5.1.3.4 SEE FIGURE A.5.1.3.4. A | | | FOUR-VALVE BYPASS ARRANGEMENT IS | | | ILLUSTRATED. THREE-WAY VALVES ARE | | | PERMITTED IN LIEU OF THE FOUR VALVES | | | SHOWN. | | | | | | 7) 11-7.2 SALES AND SERVICE COUNTERS , | | | TELLER WINDOWS, INFORMATION COUNTERS. | | | (2) AT TICKETING COUNTERS , TELLER | | | STATIONS IN A BANK, REGISTRATION | | | COUNTERS IN HOTELS AND MOTELS, BOX | | | OFFICE TICKET COUNTERS , AND OTHER | | | COUNTERS THAT MAY NOT HAVE A CASH | | | REGISTER BUT AT WHICH GOODS OR SERVICES | | | ARE SOLD OR DISTRIBUTED, EITHER: | | | (I) A PORTION OF THE MAIN COUNTER WHICH | | | IS A MINIMUM OF 36 INCHES (915 MM) IN | | | LENGTH SHALL BE PROVIDED WITH A MAXIMUM | | | HEIGHT OF 36 INCHES (915 MM); | | | | | | 8)2004 EXISTING BUILDING CODE 605.2 THE | | | MEANS OF EGRESS SHALL COMPLY WITH THE | | | REQUIREMENTS OF THIS SECTION. | | | EXCEPTIONS: | | | 1. WHERE THE WORK AREA AND THE MEANS OF | | | EGRESS SERVING IT COMPLIES WITH THE | | | FLORIDA FIRE PREVENTION CODE . | | | 2. MEANS OF EGRESS CONFORMING TO THE | | | REQUIREMENTS OF THE FLORIDA BUILDING | | | CODE, BUILDING AND THE FLORIDA FIRE | | | PREVENTION CODE UNDER WHICH THE BUILDING | | | WAS CONSTRUCTED SHALL BE CONSIDERED | | | COMPLIANT MEANS OF EGRESS IF, IN THE | | | OPINION OF THE CODE OFFICIAL, THEY DO | | | NOT CONSTITUTE A DISTINCT HAZARD TO | | | LIFE. {EXIT | | | STAIRWAYS,CHUTES,JANITORCLOSETS, GUEST | | | ROOMS, SERVICE ROOMS, ETC., SHALL NOT | | | OPEN INTO THE ELEVATOR LOBBY.1982 | | | STANDARD BUILDING CODE SEC.506.6 (1)} | | | | | | 9)11-4.13.6 MANEUVERING CLEARANCES AT | | | DOORS . MINIMUM MANEUVERING CLEARANCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIGURE 11-25 . THE FLOOR OR GROUND AREA | | | WITHIN THE REQUIRED CLEARANCES SHALL BE | | | LEVEL AND CLEAR. SEE SHEET A-3 WHERE | | | CABINETS ARE INCROUCHING ON THE MINIMUM | | | OF 18" ON THE PULL-SIDE OF THE DOORS. | | | | | | 10) SEE FBC SEC.435.3/435.4 AND 435.5 | | | FOR THE REQUIREMENTS OF RADIATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2007-09-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-26 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-22 |
Time |
14:25 |
Sent To |
PC |
|
| Notes |
| 2007-09-22 14:35:54 | **REVISED SHEET E1,2,3. | | | | | | OTHER WORK FOR BASE BUILDING PREVIOUSLY SUBMITTED WILL | | | BE UNDER SEPARATE PERMITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-13 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-13 |
Time |
12:41 |
Sent To |
PC |
|
| Notes |
| 2007-08-13 12:42:03 | ** REVISION DENIED ** | | | | | | | | | | | | 1) NOTE: PLEASE SEE NEW SHEETS E 1-3 WHICH ARE NOW | | | INDICATING SUBSTANTIAL REVISIONS TO THE BUILDING | | | ELECTRICAL SERVICE RISER. | | | AS THIS SCOPE OF WORK WAS NOT INCLUDED AND IS NOT PART | | | OF THE BASE TENANT BUILD OUT, PLEASE SUBMIT THIS SCOPE | | | OF WORK UNDER SEPARATE ELECTRICAL PERMIT FOR REVIEW. | | | THIS RISER WAS NOT REVIEWED FOR CODE COMPLIANCE. | | | FBC 106.1, 106.1.2 | | | | | | 2) NOTE: PLEASE SEE THE REVISED E-1 FOR TENANT BUILD | | | OUT NEEDS TO INCLUDE ALL CIRCUITING FOR ALL THE NEW | | | RECEPTACLES ETC SHOWN. THERE ARE A SUBSTANTIAL AMOUNT | | | OF RECEPTACLES WHICH HAVE BEEN ADDED TO CIRCUITS. | | | PLEASE SUBMIT REVISED PANEL SCHEDULES ALONG WITH | | | REVISED LOAD CALCULATIONS FOR INCREASED LOADS. | | | 408.4, 220.12, 220.14 ETC. | | | | | | 3) NOTE: PLEASE KNOW AS OF THIS REVIEW THE LOW VOLTAGE | | | PERMIT FOR PHONE/DATA HAS BEEN PLACED ON HOLD AS FEES | | | ARE OWED FOR INCREASED VALUE. THE VALUE AS STATED ON | | | PERMIT APPLICATION DOES NOT ACCURATELY REFLECT THE | | | SCOPE OF WORK OF LV CABLING ON PLANS. | | | SPOKE TO CONTRACTOR/QUALIFIER AND HE WILL PAY THE FEES | | | OWED. | | | FBC 108.3 | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-26 |
Time |
19:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-26 |
Time |
19:38 |
Sent To |
|
|
| Notes |
| 2007-03-26 19:38:40 | TWO NEW SETS SUBMITTED, STAMPED BOTH NEW SETS. OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-10 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-10 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2007-03-10 15:03:24 | ** UNSAT 6TH REVIEW ** | | | | | | 1) NOTE: PLEASE SEE ROOM CL AS THE DOOR WAY/COUNTER FOR | | | ACCESS DOES NOT CORRELATE WITH ARCHITECTURAL SHEETS. | | | | | | 2) NOTE: PLEASE SEE ONLY ONE SET OF NEW PLANS/SHEETS | | | WERE SUBMITTED. PLEASE KNOW THAT A PHONE CALL WAS | | | PLACED TO CONTRACTOR TO INFORM THEM THAT ONLY ONE SET | | | OF NEW PLANS WAS SUBMITTED. | | | PLEASE KNOW AT THIS TIME PLANS CAN NOT BE STAMPED AND | | | PASSED. | | | | | | ** PLEASE KNOW NOTE #1 CAN BE REDLINED TO BE CORRECTED | | | BEFORE ROUGH IF ALL OF THE OTHER COMMENTS FROM OTHER | | | TRADES ARE OK AND WHEN TWO SETS OF PLANS ARE | | | SUBMITTED. | | | PLUMBING REVIEWER CALLED CONTRACTOR AND INFORMED HIM | | | THAT ONLY ONE NEW SET WAS SUBMITTED ALONG WITH THE TWO | | | OLD SETS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE/REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-23 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-23 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2007-02-23 11:37:05 | *** UNSAT *** | | | | | | 1) NOTE: PLANS WHICH WERE PREVIOUSLY PASSED HAVE NOW | | | BEEN "VOIDED". PLEASE CORRELATE ALL FLOOR LAYOUTS AND | | | DOORWAY LAYOUTS. PLEASE SEE THE ELECTRICAL SHEETS DO | | | NOT WITH ARCHITECTURAL, AND EVEN THE SAME ELECTRICAL | | | SHEETS DO NOT MATCH. THIS WAS BROUGHT TO THIS REVIEWERS | | | ATTENTION AND ANY STAMPED ELECTRICAL SHEETS AS | | | ELECTRICAL COMPLIANCE WAS OK, HAVE NOW BEEN "VOIDED". | | | PLEASE SEE SHEET E-3 IS OK, AS IT DOES NOT CONTAIN ANY | | | FLOOR/DOOR LAYOUTS ETC. | | | PLEASE SEE THE F-1 SHEET HAS NOW ALSO BEEN VOIDED AS | | | THEY DOE NOT CORRELATE WITH THE ARCHITECTURAL. | | | | | | | | | PLEASE BE SURE COORDINATION IS DONE FOR ALL TRADES AND | | | FOR ALL SHEETS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICESDEPARTMENT | | | CITY OF WEST PALM BEACH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-02-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-18 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-18 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2007-02-18 16:16:59 | PASSED, AND STAMPED ELECTRICAL SHEETS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-20 |
Time |
19:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-20 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2006-11-20 19:59:13 | ****** UNSAT 3RD REVIEW ******* | | | | | | ** PLEASE SEE SOME NOTE FROM PREVIOUS REVIEWS WHICH | | | STILL NEED TO BE ADDRESSED. | | | | | | ** PLEASE SEE NO RESPONSE LETTERS WERE SUBMITTED IN | | | SETS. | | | | | | | | | 1) NOTE:NO, PLEASE SEE NO COMPLIANCE WITH FBC CHAPTER | | | 13 HAS BEEN ADDRESSED. PLEASE SEE THIS IS A TENANT | | | BUILD OUT IN A BUILDING GREATER THAN 5000 SQ FT. THIS | | | IS NOT FOR THE REST OF THE BUILDING; IT IS FOR THIS | | | TENANT SPACE. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE 13-415.1.AB.1, 13-415.2, 13-415.2.ABC.1, | | | TABLES 415.2.C.1, OR 415.2.B.1. | | | NO ENERGY CALCULATIONS, NO PERFORMANCE CALCULATIONS, | | | LIGHTING CONTROLS ETC. | | | PLEASE SEE THE 2004 FBC. THIS IS NOT UNDER THE 2001 | | | FBC. | | | | | | | | | ** PREVIOUS REVIEW NOTES FROM REVIEW ONE AND TWO. ** | | | PLEASE SEE PLANS ARE NOTED AS MEETING THE NEW FLORIDA | | | ENERGY CODE; HOWEVER NO ITEMS COULD BE LOCATED ON PLANS | | | TO VERIFY THIS. | | | PLEASE SEE 2004 FBC | | | 13-415.1.ABC.1.1,.1.2,.1.3. | | | PLEASE SEE 13-415.1.AB.1, | | | 13-415.2.ABC.1. | | | PLEASE SEE EXCEPTIONS FOR MEDICAL AREAS FOR PROCEDURES | | | ETC. | | | | | | PLEASE PROVIDE THE TIME OF DAY SCHEDULING, DEVICES, | | | DEVICE LOCATIONS, OVER-RIDES AND LOCATIONS. PLEASE | | | SPECIFY THE AMOUNT OF TIME (MAX) ON DEVICE(S) USED FOR | | | OVER RIDES IN SPACES ETC. | | | **PLEASE KNOW THE DEVICE(S) CAN BE LISTED ON THE | | | ELECTRICAL DEVICE LEGEND AND NOTED ACCORDINGLY. | | | | | | 2) NOTE: PLEASE SEE SECTION #2/PANEL "B" IS SHOWN AS | | | 100A'S ON SCHEDULE AND 225A ON RISER. THIS WAS IN | | | PREVIOUS REVIEWS HOWEVER PART OF THE CHANGES WERE DONE | | | WITH WHITE-OUT ON PLANS. PLEASE KNOW, UNDER NO | | | CIRCUMSTANCES MAY WHITE OUT BE PLACED ON PLANS, | | | ESPECIALLY PLANS SIGNED, DATED AND SEALED BY AN | | | ARCHITECT OR ENGINEER. | | | | | | 3) NOTE: PLEASE SEE PLANS APPEAR TO BE SIGNED WITH | | | "INITIALS", IF INDEED THIS IS THE LEGAL SIGNATURE OF | | | THE ENGINEER OF RECORD, PLEASE SUBMIT A SIGNED, DATED, | | | SEALED AND NOTARIZED LETTER FOR SIGNATURE VERIFICATION. | | | THIS WILL BE PLACED IN OUR SIGNATURE FILE FOR ANY | | | FUTURE REFERENCE. PLEASE BE SURE THE LETTER IS PROPERLY | | | NOTARIZED AS REQUIRED PER FLORIDA STATUTES 117.05. | | | | | | 4) NOTE: PLEASE KNOW A 4X FEE HAS NOW BEEN ASSESSED FOR | | | THIS SAID PLAN REVIEW AS REQUIRED UNDER THE FS AS | | | NOTED. )PLEASE SEE PREVIOUS NOTES GAVE A NOTICE TO | | | FLORIDA STATUTES 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONALS AND REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE KNOW AT THIS TIME A FEE OF $7,200.00 WILL BE DUE | | | BEFORE PLANS CAN BE RESUBMITTED FOR REVIEW. MAY NOT | | | SUBMIT UNTIL THIS FEE IS PAID, THIS IS REQUIRED PER THE | | | FLORIDA STATUTES AS NOTED. THIS FEE IS NOT TO THE | | | CONTRACTOR OR OWNER. | | | PLEASE KNOW AT THIS TIME ONE SET OF EACH SUBMITTED | | | ELECTRICAL PLANS ARE BEING RETAINED BY THIS OFFICE. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | **IF THERE ARE ANY QUESTIONS, COMMENTSOR IF ANY OF | | | THE NOTES TYPEDWHICH ARE UNCLEAR IN ANY WAY, PLEASE | | | DO NOT HESITATEIN CONTACTING THIS REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-10 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-10 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2006-08-10 00:00:00 | ****** UNSAT 2ND REVIEW ******* | | | | | | ** PLEASE SEE SOME NOTE FROM PREVIOUS | | | REVIEW WHICH STILL NEED TO BE ADDRESSED. | | | PLEASE SEE NOTE BELOW ARE TAKEN DIRECTLY | | | FROM THE PREVIOUS REVIEW. | | | PLEASE SEE NEW NOTES BELOW ADDED TO THE | | | BOTTOM. | | | | | | 1) NOTE: OK, HOWEVER PLEASE SEE NEW | | | ENGINEER WHICH IS SIGNED AND SEALED ON | | | PLANS IS REQUIRED TO HAVE TITLE BLOCKS | | | ON SAID PLANS WITH ALL INFORMATION AS | | | SET-FORTH UNDER FLORIDA ADMINISTRATIVE | | | CODE 61G15-23.002, FS 471.025. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CLARIFY SERVICE AS SHOWN | | | AS SOME ITEMS ARE SHOWN AS EXISTING AND | | | SOME OTHER ITEMS DO NOT INDICATE BEING | | | EXISTING. IT IS BEING TAKEN THAT THESE | | | ITEMS ARE NEW. | | | PLEASE SEE NEW SYSTEMS INVOLVING | | | 277/480V SYSTEMS SHALL BE SIGNED, DATED | | | AND SEALED BY A PE. | | | 471.003 (2)(H). | | | | | | 2) NOTE: NO, PLEASE SEE AS PLANS SHOWS | | | THESE ARE STILL BEING TAPPED CONDUCTORS | | | EXCEEDING PERMITTED LENGTHS PER 240.21. | | | PLEASE REVISE RISER FOR CODE COMPLIANCE. | | | (SUGG: ONE FEEDER TO PANEL W/FEED THRU | | | LUGS>) THIS IS ONLY NOTED AS THERE ARE | | | MANY SCENERIOS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE RISER SHOWS A GUTTER | | | IN THE LOAD SIDE OF THE TRANSFORMER | | | WHICH VIOLATES THE NEC 240.21. THIS IS | | | SHOWING TAPPED CONDUCTORS BEING FED FROM | | | OTHER TAPPED CONDUCTORS. THIS IS NOT | | | PERMITTED , AND IF THIS IS EXISTING, | | | THIS WILL BE REQUIRED TO BE CORRECTED. | | | PLEASE KNOW, THE TAPPED CONDUCTORS ON | | | THE SEC SIDE OF THE TRANSFORMER SHALL | | | TERMINATE IN A SINGLE MEANS OF OCP WHEN | | | USING THE 10FTRULE ETC. | | | PLEASE ADJUST RISER. | | | | | | 3) NOTE: OK. | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: NO, PLEASE SEE THE TENANT BUILD | | | OUT SPACE IS IN A BUIDLING WHICH IS | | | LARGER THAN 5000 SQFT AND WILL REQUIRE | | | CONTROLS IN THIS BUILD OUT SPACE. THIS | | | COMMENT WAS NOT FOR UPDATING THE REST OF | | | THE BUILDING. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PLANS ARE NOTED AS | | | MEETING THE NEW FLORIDA ENERGY CODE, | | | HOWEVER NO ITEMS COULD BE LOCATED ON | | | PLANS TO VERIFY THIS. | | | PLEASE SEE 2004 FBC | | | 13-415.1.ABC.1.1,.1.2,.1.3. | | | PLEASE SEE 13-415.1.AB.1, | | | 13-415.2.ABC.1. | | | PLEASE SEE EXCEPTIONS FOR MEDICAL AREAS | | | FOR PROCEDURES ETC. | | | | | | PLEASE PROVIDE THE TIME OF DAY | | | SCHEDULING, DEVICES, DEVICE LOCATIONS, | | | OVER-RIDES AND LOCATIONS. PLEASE SPECIFY | | | THE AMOUNT OF TIME(MAX) ON DEVICE(S) | | | USED FOR OVER RIDES IN SPACES ETC. | | | **PLEASE KNOW THE DEVICE(S) CAN BE | | | LISTED ON THE ELECTRICAL DEVICE LEGEND | | | AND NOTED ACCORDINGLY. | | | | | | 8) NOTE: OK, HOWEVER THIS NOTE WILL | | | REMAIN AS NEW EQUIPMENT AND LOCATIONS | | | WILL MOST LIKELY CHANGE DUE TO ONE OF | | | THE ABOVE COMMENTS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CLARIFY LOCATIONS OF ALL | | | ELECTRICAL EQUIPMENT, AS PANELS ARE | | | SHOWN ON PLANS, HOWEVER NOT CLEAR WHERE TRANSFORMER AND | | | TWO OTHER DISCONNECTS | | | ARE ?? | | | 215.5,110.26, ETC | | | | | | 9) NOTE: OK. | | | | | | ***NEW NOTES ** | | | | | | 10) NOTE: PLEASE SEE THE ADDRESSING | | | REVIEWER HAS ADDED AND EXTENSION AND NEW | | | SUITE # OF 702 FOR THIS SPACE. PLEASE | | | ADJUST ADDRESS ON TITLE BLOCKS. | | | | | | 11) NOTE: PLEASE SEE FS 553.80(2)(B) | | | WITH RESPECT TO THE DEISGN PROFESSIONALS | | | AND REPEAT COMMENTS. | | | | | | ** IMPORTANT** | | | WHEN AND BEFORE RESUBMITTING PLANS ONCE | | | ALL REVIEWS ARE DONE. PLEASE COMPLETELY | | | REMOVE ALL OLD/VOIDED SHEETS AND ONLY | | | INSERT ANY OF THE NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | PLEASE SUBMIT ONLY ONE COPY OF THE | | | OLD/REMOVED VOIDED SHEETS FOR REFERENCE | | | ONLY. THESE WILL BE SEPARATE FROM NEW | | | SETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-28 |
Time |
20:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-28 |
Time |
19:06 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | ****** UNSAT ******* | | | | | | 1) NOTE: PLEASE CLARIFY SERVICE AS SHOWN | | | AS SOME ITEMS ARE SHOWN AS EXISTING AND | | | SOME OTHER ITEMS DO NOT INDICATE BEING | | | EXISTING. IT IS BEING TAKEN THAT THESE | | | ITEMS ARE NEW. | | | PLEASE SEE NEW SYSTEMS INVOLVING | | | 277/480V SYSTEMS SHALL BE SIGNED, DATED | | | AND SEALED BY A PE. | | | 471.003 (2)(H). | | | | | | 2) NOTE: PLEASE SEE RISER SHOWS A GUTTER | | | IN THE LOAD SIDE OF THE TRANSFORMER | | | WHICH VIOLATES THE NEC 240.21. THIS IS | | | SHOWING TAPPED CONDUCTORS BEING FED FROM | | | OTHER TAPPED CONDUCTORS. THIS IS NOT | | | PERMITTED , AND IF THIS IS EXISTING, | | | THIS WILL BE REQUIRED TO BE CORRECTED. | | | PLEASE KNOW, THE TAPPED CONDUCTORS ON | | | THE SEC SIDE OF THE TRANSFORMER SHALL | | | TERMINATE IN A SINGLE MEANS OF OCP WHEN | | | USING THE 10FTRULE ETC. | | | PLEASE ADJUST RISER. | | | | | | 3) NOTE: PLEASE INCLUDE ALL EQUIPMENT | | | GROUNDING CONDUCTORS AS REQUIRED. | | | 250.110,250.24B , 250.122 | | | | | | 4) NOTE: PLEASE INDICATE THE GROUNDING | | | ATTACHEMENT FOR THE TRANSFORMER. | | | 250.66,250.30, 250.50 | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 6) NOTE: PLEASE SEE THAT ALL CURRENT | | | CODES AS FOLLOWS SHALL BE STATED ON | | | PLANS/DESIGN. | | | NFPA-70,2002, NFPA-101 2003, NFPA-72 | | | 2002. | | | | | | 7) NOTE: PLEASE SEE PLANS ARE NOTED AS | | | MEETING THE NEW FLORIDA ENERGY CODE, | | | HOWEVER NO ITEMS COULD BE LOCATED ON | | | PLANS TO VERIFY THIS. | | | PLEASE SEE 2004 FBC | | | 13-415.1.ABC.1.1,.1.2,.1.3. | | | PLEASE SEE 13-415.1.AB.1, | | | 13-415.2.ABC.1. | | | PLEASE SEE EXCEPTIONS FOR MEDICAL AREAS | | | FOR PROCEDURES ETC. | | | | | | PLEASE PROVIDE THE TIME OF DAY | | | SCHEDULING, DEVICES, DEVICE LOCATIONS, | | | OVER-RIDES AND LOCATIONS. PLEASE SPECIFY | | | THE AMOUNT OF TIME(MAX) ON DEVICE(S) | | | USED FOR OVER RIDES IN SPACES ETC. | | | **PLEASE KNOW THE DEVICE(S) CAN BE | | | LISTED ON THE ELECTRICAL DEVICE LEGEND | | | AND NOTED ACCORDINGLY. | | | | | | 8) NOTE: PLEASE CLARIFY LOCATIONS OF ALL | | | ELECTRICAL EQUIPMENT, AS PANELS ARE | | | SHOWN ON PLANS, HOWEVER NOT CLEAR WHERE | | | TRANSFORMER AND TWO OTHER DISCONNECTS | | | ARE ?? | | | 215.5,110.26, ETC | | | | | | 9) NOTE: PLEASE CLARIFY TITLE BLOCKS ON | | | PLANS, AS PLANS INDICATE THE FIRM, | | | ARCHITECT ALONG WITH THE SAME FIRM AND | | | ARCHITECTS LICENSE NUMBER AND CA #, | | | HOWEVER PLEASE SEE TITLE BLOCKS ALSO | | | INCLUDE WHAT APPEAR TO BE A NAME OF | | | ANOTHER "ARCHITECTURAL FIRM". THESE ARE | | | STATED AS "ALIEN ARCHITECTURE"?? | | | PLEASE CLARIFY, AS THIS DOES NOT SEEM TO | | | PART OF THE TITLE BLOCK FOR SAID FIRM | | | LISTED?? | | | FAC 61G1-16.004, FS 481.219 | | | | | | ** IMPORTANT** | | | WHEN AND BEFORE RESUBMITTING PLANS ONCE | | | ALL REVIEWS ARE DONE. PLEASE COMPLETELY | | | REMOVE ALL OLD/VOIDED SHEETS AND ONLY | | | INSERT ANY OF THE NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | PLEASE SUBMIT ONLY ONE COPY OF THE | | | OLD/REMOVED VOIDED SHEETS FOR REFERENCE | | | ONLY. THESE WILL BE SEPARATE FROM NEW | | | SETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-03 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-03 |
Time |
14:42 |
Sent To |
B |
|
| Notes |
| 2007-04-03 15:10:05 | *****APPROVED***** | | | | | | | | | SHEET F-1 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
F |
Date |
2007-03-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-03-23 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-03-23 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2007-03-23 13:48:43 | ***DENIED*** | | | | | | 1) PLEASE NOTE THAT ONLY (1) COMPLETE SET OF PLANS WERE | | | SUBMITTED FOR REVIEW. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-12-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-12-06 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-12-06 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2006-12-06 11:56:38 | *****APPROVED***** | | | | | | | | | SHEET F-1 STAMPED AND DATED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-24 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-24 |
Time |
15:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-03 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-03 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2006-07-03 00:00:00 | ***DENIED*** | | | | | | 1) PLEASE NOTE THAT ANY ELEVATION CHANGE | | | IN EXCESS OF 1/4" SHALL COMPLY WITH NFPA | | | 101, 2003 EDITION SEC. 7.1.6.2. | | | | | | 2) PRESSURIZED GAS CYLINDERS SHALL BE | | | SECURED BY APPROVED MEANS. PLEASE SEE | | | LARGER CYLINDERS TO BE SECURED WITH | | | CHAINS. | | | | | | 3) FLORIDA FIRE PREVENTION CODE TO | | | COMPLY WITH 2004 EDITION. | | | | | | 4) PLEASE SEE MECHANICAL PROVISO. IN | | | ADDITION TO FAN SHUTDOWN, DUCT SMOKE | | | DETECTORS SHALL INITIATE A GENERAL FIRE | | | ALARM WHEN TIED INTO A FIRE ALARM | | | SYSTEM. | | | | | | 5) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-19 |
Time |
09:19 |
Sent To |
B |
|
| Notes |
| 2007-11-26 13:27:16 | TO MYRON, ARCHITECTURAL SHEET./WRT. | | 2007-11-19 09:19:47 | TO "BTROBAUGH" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-21 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-21 |
Time |
16:20 |
Sent To |
E |
|
| Notes |
| 2007-09-21 16:20:25 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-06 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-06 |
Time |
18:04 |
Sent To |
E |
|
| Notes |
| 2007-08-06 18:04:30 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-02 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-02 |
Time |
10:05 |
Sent To |
M |
|
| Notes |
| 2007-08-02 10:06:05 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-03-26 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-03-26 |
Time |
18:35 |
Sent To |
|
|
| Notes |
| 2007-03-26 18:36:00 | SENT TO BOB # 16 MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-10 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-10 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2007-03-10 10:56:38 | TO "BOB"#3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-16 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-16 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2007-02-16 11:53:41 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-08 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-08 |
Time |
17:00 |
Sent To |
|
|
| Notes |
| 2006-11-20 16:35:24 | TO "BOB"#15 | | 2006-11-08 17:01:03 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-24 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-24 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2006-08-09 00:00:00 | TO "BOB"#4 | | 2006-07-24 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-26 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | TO "BOB"#3 | | 2006-06-26 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-07 |
Time |
15:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-08-07 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2007-08-07 15:43:49 | REVISION TO MECH. PLANS PAGE AC-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-27 |
Time |
16:01 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-13 |
Time |
11:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2007-03-13 11:41:51 | *** DENIED *** | | | 1) PLANS PAGE A-4 SHOWS THE WALLS FOR THE CORRIDOR, | | | MAIN LAB AND PORCELAIN ROOM TO BE ONE HOUR FIRE RATED | | | (WALL SYMBOL LEGEND), SEE PAGE AC-1 ALL THE A/C DUCTS | | | THAT PENETRATE THE FIRE RATED WALLS NEED TO COMPLY WITH | | | 2004 FBC/M 607, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-02-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-23 |
Time |
08:37 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-23 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2007-02-23 09:00:36 | *** DENIED *** | | | 1) PLANS PAGE A-4 SHOWS THE WALLS FOR THE MAIN LAB AND | | | PORCELAIN ROOM TO BE ONE HOUR FIRE RATED, SEE PAGE AC-1 | | | ALL THE A/C DUCTS THAT PENETRATE THE FIRE RATED WALLS | | | NEED TO COMPLY WITH 2004 FBC/M 607, PLEASE CORRECT. | | | | | | 2) SEE PAGE AC-1 MECHANICAL ROOM THE 62X12 SUPPLY AIR | | | DUCT PENETRATING THE FIRE RATED WALL WILL NEED A FIRE | | | DAMPER, SEE 2004 FBC/M 607.5.1,PLEASE CORRECT. | | | | | | 3) SEE PAGES A-3 AND A-4 (ARCHITECT'S SEAL) THE | | | ARCHITECT NEED TO PUT THE DATE WHEN HE SIGNED AND | | | SEALED THE PLANS, SEE FAC 61G1-16.003. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-22 |
Time |
13:56 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-22 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2006-11-22 13:59:22 | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #3 REGARDING ENGINEER'S | | | SIGNATURE, PLEASE RESPOND. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | 2006-11-20 20:02:44 | NEW SHEETS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-28 |
Time |
16:38 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-06-28 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2006-06-28 00:00:00 | *** PROVISO *** | | | 1) SMOKE DETECTORS SHALL BE INSTALLED | | | SUPPLY SYSTEMS WITH A DESIGN CAPACITY | | | GREATER THAN 2,000 CFM, IN THE SUPPLY | | | AIR DUCT. 2001 FBC(M) 606.2.1OR | | | UPON ACTIVATION, THE SMOKE DETECTORS | | | SHALL SHUTDOWN THE AIR DISTRIBUTION | | | SYSTEM. 2001 FBC(M) 606.4 | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
6 |
Status |
P |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-31 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-31 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2007-03-31 08:58:36 | COPY OFINSTALLERS LICENSE REQUIRED WITH APPLICATION |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
5 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
14:06 |
Sent To |
|
|
| Notes |
| 2007-03-10 14:07:17 | ONLY ONE SET OF PLANS. PLUMBING OK WILL PASS WHEN | | | SECOND SET SUBMITED. |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
4 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-28 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-28 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2007-02-28 07:15:42 | DENIED; | | | 1. SHEET A-2 DEMO PAGE IS MISSING FROM ONE SET OF | | | PLANS. | | | 2. ALL PAGES ARE TO BE SIGNED AND DATED. | | | MED-GAS OK BUT CANNOT BE STAMPED AND SIGNED | | | AT THIS TIME. | | | MED-GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
3 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-21 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-21 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2006-11-21 14:02:02 | DENIED; | | | | | | THE MED-GAS PAGES ARE REQUIRED TO BE SEALED BY A | | | REGISTERED ENGINEER SEE FBC-2004 CHAPTER 1 | | | ADMINISTRATION WEST PALM BEACH | | | AMENDMENTS. | | | MED-GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
2 |
Status |
F |
Date |
2006-08-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-26 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-26 |
Time |
06:54 |
Sent To |
|
|
| Notes |
| 2006-08-26 00:00:00 | DENIED; | | | 1. PAGE P-4 NOT SEALED OR SIGNED. | | | 2. PAGE A-3 (OXYGEN CLOSET) REMOVE THE | | | NOTATION FOR NITROUS OXIDE. (N2O) | | | MED-GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-30 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-30 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2006-06-30 00:00:00 | DENIED; | | | 1.ADD TO NOTES; OXYGEN, COMPRESSED AIR , | | | AND VACUUM PIPING TO BE INSTALLED BY A | | | CERTIFIED MED-GAS CONTRACTOR. SEPARATE | | | PERMIT REQUIRED. | | | 2.PAGE P-3 OXYGEN PIPING DIAGRAM; SHOW | | | PIPE SIZE, MATERIAL, AND HOW JOINTS ARE | | | TO BE DONE. ALSO SHOW ALL SHUTOFF VALVES | | | AND ALARMS REQUIRED. | | | 3.SHOW DETAIL OR LIST EQUIPMENT TO BE | | | USED TO SECURE OXYGENT TANKS. | | | 4.LEVEL 3 VACUUM; SHOW CHECK VALVE | | | REQUIRED SEC. 5.3.3.6.3.2(1) AND A NOTE | | | REQUIRING A DEEP SEAL TRAP SEC. | | | 5.3.3.6.3.2(2). | | | 5 ADD TO PLANS, EXHAUST FROM VACUUM | | | SYSTEM TO BE SCREENED SEC. 5.3.3.6.4.6. | | | MED-GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-31 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-31 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-03-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-10 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-10 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2007-03-10 14:05:38 | ONLY ONE SET OF PLANS SUBMITED. MED-GAS OK NEED 2ND SET | | | BEFORE APPROVAL. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-28 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-28 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2007-02-28 07:22:18 | DENIED; | | | 1.DEMO PAGE MISSING FROM ONE SET OF PLANS. | | | 2.ALL PAGES TO BE SIGNED AND DATED. | | | PLUMBING PLAN REVIEW OK BUT CAN NOT BE STAMPED AND | | | SIGNED AT THIS TIME. | | | ONE SET OF PLANS HAS BEEN RETAINED BY THIS | | | OFFICE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-11-21 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-11-21 |
Time |
13:10 |
Sent To |
|
|
| Notes |
| 2006-11-21 13:55:22 | DENIED; | | | FBC-2004 , CHAPTER 1, ADMINISTRATION; SECTION | | | 105.3.1.2(5). THE PLUMBING AND MED-GAS PLANS ARE | | | REQUIRED TO BE SEALED BY A REGISERED | | | ENGINEER. | | | PAGE P-1 SANITARY DESIGN NOTE,SECTION 7.14.4.2,THE | | | REGISTERED DESIGN PROFESSIONAL SHALL INDICATE ON THE | | | PERMIT APPLICATION | | | THAT THE PLUMBING SYSTEM IS AN ALTERNATIVE ENGINEER | | | DESIGN. NOT LISTED ON PERMIT APP. 714.4.3NO TECHNICAL | | | DATA SUBMITED TO SUBSTANTIATE THE PROPOSED ALTERATIVE | | | ENGINEER DESIGN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-26 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-26 |
Time |
06:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-30 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-30 |
Time |
08:22 |
Sent To |
PC |
|
| Notes |
| 2006-06-30 00:00:00 | DENIED; | | | 1. PAGE P-4 WATER HEATER DETAIL; HEATER | | | PAN WITH DRAIN REQUIRED FBC-2004 | | | PLUMBING SEC. 504.7, AND 504.7.1 AND 2. | | | THERMAL EXPANTION CONTROL REQUIRED SEC. | | | 607.3 | | | 2.PAGE P-5 NOTE 33; "CAST IRON IS | | | REQUIRED IN THIS STRUCTURE" SHOULD | | | VACUUM SYSTEM LINES BE COPPER? | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|