Plan Review Details - Permit 06061320
Plan Review Stops For Permit 06061320
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-01-24 Cont ID  
Sent By rmcdouga Date 2007-01-24 Time 13:45 Rev Time 0.00
Received By rmcdouga Date 2007-01-24 Time 13:45 Sent To  
Notes
2007-01-24 13:50:21REVISED SHEETS 1,2,3,9,10,13A,14R,15R,16R,17R AND 18R
 THE OTHER SHEETS THAT WERE SUBMITTED HAD NO CHANGES AND
 WERE TREATED AS RESTAMPS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-09-26 Cont ID  
Sent By rmcdouga Date 2006-09-26 Time 08:13 Rev Time 0.00
Received By rmcdouga Date 2006-09-26 Time 07:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-09-22 Cont ID  
Sent By rmcdouga Date 2006-09-22 Time 14:42 Rev Time 0.00
Received By rmcdouga Date 2006-09-22 Time 14:42 Sent To  
Notes
2006-09-22 00:00:00DENIED
  
 1) FAC 61G15 REQUIRES THE ENGINEER TO
 LGIBLE INDICATE THEIR NAME AND LICENSE
 NUMBER ON EACH SHEET OF PLANS. THE FIRST
 SHEET IS MISSING THIS INFORMATION.
  
 2) EACH SHEET OF THE PLANS ARE REQUIRED
 TO DATED BY THE ENGINEER SIGNING AND
 SEALING THEM. FAC 61G15-23.002
  
 3) FBC 106.3.3 (CITY AMENDMENTS)
 REQUIRES THE PRODUCT APPROVALS SUBMITTED
 PURSUANT TO RULE 9B-72 TO BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD.
  
 4) SHEET 24 SPECIFIES A CRUSHED CONCRETE
 APPROACH WITH A MAXIMUM SLOPE OF 1:12
 WHICH IS A RAMP ANDMUST COMPLY WITH FBC
 11-4.8 FOR HANDRAILS, LANDINGS, ETC.
 SHEET 23 SPECIFIES A MAXIMUM SLOPE OF
 1:20 AT THIS LOCATION. PLEASE CLARIFY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-10 Cont ID  
Sent By rmcdouga Date 2006-07-10 Time 16:35 Rev Time 0.00
Received By rmcdouga Date 2006-07-10 Time 16:35 Sent To  
Notes
2006-07-11 00:00:00DENIED
  
 1) FAC 61G15 REQUIRES THE ENGINEER TO
 LEGIBLY INDICATE THEIR NAME AND LICENSE
 NUMBER ON EACH SHEET OF PLANS.
  
 2) THE CODE EDITION LISTED ON SHEET 7 IS
 INCORRECT. PLEASE UPDATE TO 2004 FBC.
  
 3) THE DESIGN PARAMETER INFORMATION ON
 SHEET 7 IS INCORRECT.
 - THE IMPORTANCE FACTOR FOR THESE
 STRUCTURES IS .77
 - THE BUILDING CATEGORY IS OPEN.
 - THE INTERNAL PRESSURE COEFFICENT FOR
 OPEN STRUCTURES IS 0.00.
 PLEASE SEE ASCE7-02.
  
 4) ON SHEET THERE ARE GENERAL AND
 STRUCTURAL NOTES THAT DO NOT APPLY TO
 THIS PROJECT. PLEASE REMOVE THOSE THAT
 DO NOT APPLY. PLANS ARE REQUIRED TO BE
 SPECIFIC TO THE WORK PROPOSED. SEE FBC
 106.1.1 (CITY AMENDMENTS).
  
 5)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
 SUBMIT PRODUCT APPROVALS FOR THE SIMPSON
 CONNECTORS.
  
 6) FBC 106.3.3 (CITY AMENDMENTS)REQUIRES
 THE PRODUCTS THAT ARE REGULATED BY DCA
 RULE 9B-72 TO BE REVIEWED AND APPROVED
 IN WRITING BY THE DESIGNER OF RECORD
 PRIOR TO SUBMITTAL.
  
 7) SPECIFY THE UNIFORM LIVE LOAD FOR THE
 WALKWAYS AND ELEVATED PLAT FORMS. FBC
 TABLE 1607.1 REQUIRES A MINIMUM OF
 60 PSF.
  
 8) FBC 11-4.8.4 LANDINGS.
 RAMPS SHALL HAVE LEVEL LANDINGS AT
 BOTTOM AND TOP OF EACH RAMP AND EACH
 RAMP RUN. LANDINGS SHALL HAVE THE
 FOLLOWING FEATURES:
 2)ALL LANDINGS ON RAMPS SHALL BE
 NOT LESS THAN 60 INCHES (1524 MM) CLEAR,
 AND THE BOTTOM OF EACH RAMP SHALL HAVE
 NOT LESS THAN 72 INCHES (1829 MM) OF
 STRAIGHT AND LEVEL CLEARANCE.
  
 9) FBC 11-4.9.2 TREADS AND RISERS.
 ON ANY GIVEN FLIGHT OF STAIRS, ALL STEPS
 SHALL HAVE UNIFORM RISER HEIGHTS AND
 UNIFORM TREAD WIDTHS. STAIR TREADS SHALL
 BE NO LESS THAN 11 INCHES (280 MM) WIDE,
 MEASURED FROM RISER TO RISER. SEE SHEET
 16R.
  
 10) FBC 1009.3 STAIR TREADS AND RISERS.
 STAIR RISER HEIGHTS SHALL BE 7 INCHES
 (178 MM) MAXIMUM AND 4 INCHES (102 MM)
 MINIMUM. STAIR TREAD DEPTHS SHALL BE 11
 INCHES (279 MM) MINIMUM. THE RISER
 HEIGHT SHALL BE MEASURED VERTICALLY
 BETWEEN THE LEADING EDGES OF ADJACENT
 TREADS. THE GREATEST RISER HEIGHT WITHIN
 ANY FLIGHT OF STAIRS SHALL NOT EXCEED
 THE SMALLEST BY MORE THAN 0.375 INCH
 (9.5 MM). SEE SHEET 16R.
  
 11) FBC11-4.9.4 HANDRAILS.
 STAIRWAYS SHALL HAVE HANDRAILS AT BOTH
 SIDES OF ALL STAIRS. HANDRAILS SHALL
 COMPLY WITH SECTION 11-4.26 AND SHALL
 HAVE THE FOLLOWING FEATURES:
  
 (2)IF HANDRAILS ARE NOT
 CONTINUOUS, THEY SHALL EXTEND AT LEAST
 12 INCHES (305 MM) BEYOND THE TOP RISER
 AND AT LEAST 12 INCHES (305 MM) PLUS THE
 WIDTH OF ONE TREAD BEYOND THE BOTTOM
 RISER. AT THE TOP, THE EXTENSION SHALL
 BE PARALLEL WITH THE FLOOR OR GROUND
 SURFACE. AT THE BOTTOM, THE HANDRAIL
 SHALL CONTINUE TO SLOPE FOR A DISTANCE
 OF THE WIDTH OF ONE TREAD FROM THE
 BOTTOM RISER; THE REMAINDER OF THE
 EXTENSION SHALL BE HORIZONTAL [SEE
 FIGURE 11-19 (C) AND FIGURE 11-19 (D)].
 HANDRAIL EXTENSIONS SHALL COMPLY WITH
 SECTION 11-4.4 .
  
 (3)THE CLEAR SPACE BETWEEN
 HANDRAILS AND WALL SHALL BE 1? INCHES
 (38 MM).
  
 (6)ENDS OF HANDRAILS SHALL BE
 EITHER ROUNDED OR RETURNED SMOOTHLY TO
 FLOOR, WALL OR POST.
  
 12) 11-4.1.2 ACCESSIBLE SITE AND
 EXTERIOR FACILITIES: NEW CONSTRUCTION.
 THIS EDITION OF THE CODE DOES NOT APPLY
 TO BUILDINGS, STRUCTURES, OR FACILITIES
 WHICH WERE EITHER UNDER CONSTRUCTION OR
 UNDER CONTRACT FOR CONSTRUCTION ON
 OCTOBER 1, 1997.
 NOTHING IN THIS CODE SHALL BE CONSTRUED
 TO RELIEVE THE OWNER OF ANY BUILDING,
 STRUCTURE OR FACILITY FROM THE DUTY TO
 PROVIDE VERTICAL ACCESSIBILITY TO ALL
 LEVELS ABOVE AND BELOW THE OCCUPIABLE
 GRADE LEVEL, REGARDLESS OF WHETHER THE
 CODE REQUIRES AN ELEVATOR TO BE
 INSTALLED IN SUCH BUILDING, STRUCTURE OR
 FACILITY, EXCEPT: (1) ELEVATOR PITS,
 ELEVATOR PENTHOUSES, MECHANICAL ROOMS,
 PIPING OR EQUIPMENT CATWALKS, AND
 AUTOMOBILE LUBRICATION AND MAINTENANCE
 PITS AND PLATFORMS; (2) UNOCCUPIABLE
 SPACES, SUCH AS ROOMS, ENCLOSED SPACES,
 AND STORAGE SPACES THAT ARE NOT DESIGNED
 FOR HUMAN OCCUPANCY, FOR PUBLIC
 ACCOMMODATIONS, OR FOR WORK AREAS; AND
 (3) OCCUPIABLE SPACES AND ROOMS THAT ARE
 NOT OPEN TO THE PUBLIC AND THAT HOUSE NO
 MORE THAN FIVE PERSONS INCLUDING, BUT
 NOT LIMITED TO, EQUIPMENT CONTROL ROOMS
 AND PROJECTION BOOTHS. HOWEVER AS
 PROVIDED IN SECTION 553.509, FLORIDA
 STATUTES, BUILDINGS, STRUCTURES, AND
 FACILITIES MUST, AT A MINIMUM, COMPLY
 WITH THE REQUIREMENTS OF THE ADAAG.
 THEREFORE, FACILITIES SUBJECT TO THE
 ADAAG MAY BE REQUIRED TO PROVIDE
 VERTICAL ACCESS TO AREAS OTHERWISE
 EXEMPT UNDER SECTION 11-4.1.3 (5) OF
 THIS CODE. VERTICAL ACCESSIBILITY IS
 REQUIRED FROM THE BOARDWALK TO THE CANOE
 LANDING PLATFORM OR DOCK. THIS IS A
 FLORIDA SPECIFIC REQUIREMENT AND THE
 APPLICANT HAS THE OPTION OF APPLYING TO
 THE FLORIDA BUILDING COMMISSION FOR A
 WAIVER.
 553.512 MODIFICATIONS AND WAIVERS;
 ADVISORY COUNCIL. THE FLORIDA BUILDING
 COMMISSION SHALL PROVIDE BY REGULATION
 CRITERIA FOR GRANTING INDIVIDUAL
 MODIFICATIONS OF, OR EXCEPTIONS FROM,
 THE LITERAL REQUIREMENTS OF THIS PART
 UPON A DETERMINATION OF UNNECESSARY,
 UNREASONABLE, OR EXTREME HARDSHIP,
 PROVIDED SUCH WAIVERS SHALL NOT VIOLATE
 FEDERAL ACCESSIBILITY LAWS AND
 REGULATIONS AND SHALL BE REVIEWED BY THE
 ACCESSIBILITY ADVISORY COUNCIL. (SEE
 SECTION 553.512, FLORIDA STATUTES).
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-01-18 Cont ID  
Sent By adarroug Date 2007-01-18 Time 10:52 Rev Time 0.00
Received By adarroug Date 2007-01-18 Time 10:52 Sent To B
Notes
2007-01-18 10:53:21TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-01-12 Cont ID  
Sent By adarroug Date 2007-01-12 Time 09:48 Rev Time 0.00
Received By adarroug Date 2007-01-12 Time 09:48 Sent To Z
Notes
2007-01-12 09:48:37TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-19 Cont ID  
Sent By adarroug Date 2006-09-19 Time 14:26 Rev Time 0.00
Received By adarroug Date 2006-09-19 Time 14:26 Sent To B
Notes
2006-09-19 00:00:00TO "RMCDOUGAL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-15 Cont ID  
Sent By adarroug Date 2006-09-15 Time 12:36 Rev Time 0.00
Received By adarroug Date 2006-09-15 Time 12:36 Sent To Z
Notes
2006-09-15 00:00:00TO "Z" BOX/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-07 Cont ID  
Sent By adarroug Date 2006-07-07 Time 10:14 Rev Time 0.00
Received By adarroug Date 2006-07-07 Time 10:14 Sent To B
Notes
2006-07-07 00:00:00TO "RMCDOUGAL" DESK/PER "LMARTINEZ"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-10 Cont ID  
Sent By rmcdouga Date 2006-07-10 Time 16:35 Rev Time 0.00
Received By rmcdouga Date 2006-06-26 Time 10:22 Sent To  
Notes
2006-06-26 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2007-01-16 Cont ID  
Sent By mmclean Date 2007-01-16 Time 10:28 Rev Time 0.00
Received By mmclean Date 2007-01-16 Time 10:28 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-09-18 Cont ID  
Sent By mmclean Date 2006-09-18 Time 16:59 Rev Time 0.00
Received By mmclean Date 2006-09-18 Time 16:59 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-07-06 Cont ID  
Sent By mmclean Date 2006-07-06 Time 07:36 Rev Time 0.00
Received By mmclean Date 2006-07-06 Time 07:36 Sent To I
Notes
***NONE***