Plan Review Details - Permit 06061149
| Plan Review Stops For Permit 06061149 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-04 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-04 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2006-08-04 00:00:00 | REDLINE DMISSING EQUIPMENT GRND. | | | REDLINED MISSING EQUIPMENT GROUNDING | | | CONDUCTOR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-03 |
Time |
20:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-03 |
Time |
20:05 |
Sent To |
PC |
|
| Notes |
| 2006-08-03 00:00:00 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PREVIOUS COMMENTS | | | WHICH REQUESTED THE PLANS/DESIGN TO | | | CONTAIN THE PRINTED NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE. | | | FBC 106.1.2 | | | | | | THE FOLLOWING CA BE REDLINED. | | | MISSING EQUIPMENT GROUNDING CONDUCTOR | | | AND MISSING CWP. | | | 250.122, 250.50 | | | | | | ** CALLED CONTRACTOR AND LEFT MESSAGE, | | | IF THE CONT CAN COME DOWN AND SIGN PLANS | | | ETC, THEN THE PERMIT CAN BE PROCESSED | | | AND ISSUED FOR PERMIT. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-15 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-15 |
Time |
11:33 |
Sent To |
PC |
|
| Notes |
| 2006-07-15 00:00:00 | *** UNSAT 2ND REVIEW ** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS | | | REVIEW. | | | PLEASE SEE RISER DIAGRAM IS NOT COMPLETE | | | AND DOES NOT CONTAIN INFORMATION AS | | | PREVIOUSLY NOTED. | | | 250.50,110.9, 250.110, 250.122, 250.24B | | | ETC | | | | | | 2) NOTE: PLEASE SEE PLANS NOW INCLUDE A | | | NEW SUB PANEL NOT IN SCOPE OF WORK ON | | | PERMIT APPL. | | | PLEASE NOTE THE LOCATION OF THIS PANEL | | | AS IT WILL BE REQUIRED TO MEET 110.26, | | | 240.24, 408.7 | | | | | | 3) NOTE: PLEASE SEE FBC ADMIN SECT | | | 106.1.3, PLANS MAY NOT BE DRAW IN | | | PENCIL. THESE MUST BE PHOTO-COPIED | | | BEFORE SUBMITTING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-25 |
Time |
12:58 |
Sent To |
PC |
|
| Notes |
| 2006-06-25 00:00:00 | *** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SUBMIT AN ELECTRICAL | | | RISER DIAGRAM WITH THE NEW PROPOSED | | | WORK. | | | PLEASE INCLUDE SEC'S, CONDUITS ETC. | | | PLEASE INCLUDE NEW GROUNDING ELECTRODE | | | SYSTEM. | | | PLEASE INCLUDE AIC RATING FOR NEW | | | SERVICE EQUIPMENT. | | | PLEASE INDICATE SIZE OF NEW M/M, AND | | | LOAD ON EXISTING. | | | PLEASE SHOW HOW FEEDS TO EXISTING | | | CIRCUITS WILL TAKE PLACE. | | | 215.5,110.9,240.4,310.16, 250.50, ETC | | | | | | 2) NOTE: PLEASE BE SURE ALL PLANS | | | CONTAIN THE PRINTED ANME AND SIGNATURE | | | OF THE PERSONRESPONSIBLE FOR | | | PLANS/DESIGN. | | | FBC 106.1.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
15:35 |
Sent To |
E |
|
| Notes |
| 2006-07-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-12 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-12 |
Time |
15:36 |
Sent To |
E |
|
| Notes |
| 2006-07-12 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-06-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | TO "E" BOX |
|
|
|