| Plan Review Stops For Permit 06061002 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-09-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-09-21 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-09-21 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | NEW STRUCTURAL ENGINEERING SHEETS, | | | SIGNED AND SEALED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-03 |
Time |
15:06 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-06-29 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-19 |
Time |
19:26 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-19 |
Time |
19:08 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | OK, STAMPED, | | | NEW RTSE WHICH CONTAINS BOTH | | | DISCONNECTS. | | | | | | PLANS HAND ROUTED BACK TO LUIS MARTINEZ. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-27 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-27 |
Time |
11:43 |
Sent To |
P |
|
| Notes |
| 2006-08-27 00:00:00 | ******* UNSAT3RD REVIEW ******** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEWS WHICH STILL ARE IN NEED OF | | | ADDRESSING. | | | PLEASE SEE NEW NOTE ADDED. | | | | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE: NO, SAME NOTE>, SPEC SHOW MORE | | | THAN ONE ATS. | | | | | | ** PREVIOUS REVIEW NOTE 2ND REVIEW ** | | | SAME, PLEASE BE SURE TO HIGH- | | | LIGHT UNIT. | | | | | | ** PREVIOUS REVIEW NOTE1ST REVIEW ** | | | PLEASE SEE THAT THE ATS AS | | | SHOWN MUST BE "SERVICE ENTRANCE RATED, | | | CONTAINING A MANUAL MEANS OF DISCONNECT | | | RATED FOR THE LOAD SERVED ETC | | | PLEASE "HIGHLIGHT" THE ATS. | | | 230.70,230.76,230.79 | | | | | | 3) NOTE: NO, PLEASE SEE NO DISCONNECT IS | | | BEING SHOWN AND GROUPED WITH THE NEW | | | MAIN. **PLEASE SEE THAT GENERAC NOW | | | MAKES A SE RATED ATS WHICH MEETS CODE | | | COMPLIANCE FOR THE THE DISCONNECITNG OF | | | THE FPL POWER AND THE FEEDERS FROM THE | | | GEN. (RTSE WHICH CONTAINS TWO-200A | | | BREAKERS) THIS IS ONLY NOTED AS THE RTSE | | | IS NOT THE ONLY WAY TO MEET CODE | | | COMPLIANCE FOR THE DISCONNETING OF | | | FEEDERS.225.34, 230.72 | | | THE BREAKER INSIDE THE GEN CAN NOT BE | | | USED AS IT DOES NOT MEET CODEAND THE | | | ATS SUBMITTED ONLY DISCONNECTS THE POWER | | | FROM FPL. THE TOGGLE SWITCH IN THIS TYPE | | | OF ATS DOE NOT MEET CODE FOR DISCONNECT | | | RATED FOR THE LOAD SERVED. | | | | | | ** PREVIOUS REVIEW NOTES 2ND REVIEW ** | | | SAME, PLEASE SEE NO DISCONNECT | | | SHOWN. | | | ** PLEASE KNOW, GENERAC NOW HAS A NEW SE | | | RATED ATS ON THE MARKET WHICH WOULD MEET | | | THIS AS IT CONTAINS A MANUAL MEANS OF | | | DISCONNECT FOR THE NORMAL (FPL) SIDE AND | | | THE EM/GEN FEEDER SIDE. THIS IS NO WAY | | | SAYING THIS NEW UNIT HAS TO BE USED. | | | THIS ONLY REQUIRES A DISCONNECTING MEANS | | | AND DOES NOT REQUIRED OCP. CAN BE A | | | KNIFE TYPE SWITCH ETC. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #1 ** | | | PLEASE SEE MISSING DISCONNECT | | | FOR FEEDERS FROM GEN GROUPED WITH NEW | | | MAIN. BRKR INSIDE GEN MAY NOT SERVE AS | | | THIS DISCONNECT MEANS | | | 225.31-225.39 | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK. | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: NO. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #2** | | | SAME, PLEASE SEE ABOVE NOTE | | | WITH RESPECT TO THE ATS BEING INSTALLED. | | | | | | ** PREVIOUS REVIEW NOTE REVIEW #1 ** | | | PLEASE INDICATE AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT. | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: OK. | | | | | | ** NEW NOTES ** | | | | | | 11) NOTE: PLEASE SEE A 4X FEE FOR THE | | | PLAN REVIEW PORTION OF THE PERMIT FEE | | | HAS NOW BEEN ASSESSED AS REQUIRED PER FS | | | 553.80(2)(B). PLEASE KNOW THE FEE OF | | | $520.68 IS DUE BEFORE PLANS MAY BE | | | RESUBMITED. | | | | | | 12) NOTE: PLEASE KNOW THE PERMIT | | | APPLICATION WAS NOT IN PACKAGE. PLEASE | | | BE SURE THE APPLICATION IS BROUGHT BACK | | | IN. PLEASE ALSO BE SURE THAT THE | | | ELECTRICLA PERMIT LINE IS SIGNED SO AN | | | ELECTRICAL PERMIT (GEN-ELEC) PERMIT | | | NUMBER CAN BE GENERATED FOR THE | | | ELECTRICALPORTION OF THE GENERATOR | | | INSTALLATION. | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-03 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-03 |
Time |
14:44 |
Sent To |
B |
|
| Notes |
| 2006-08-03 00:00:00 | ******* UNSAT2ND REVIEW ******** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW WHICH STILL ARE IN NEED OF | | | ADDRESSING. | | | | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE:SAME, PLEASE BE SURE TO HIGH- | | | LIGHT UNIT. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THAT THE ATS AS | | | SHOWN MUST BE "SERVICE ENTRANCE RATED, | | | CONTAINING A MANUAL MEANS OF DISCONNECT | | | RATED FOR THE LOAD SERVED ETC | | | PLEASE "HIGHLIGHT" THE ATS. | | | 230.70,230.76,230.79 | | | | | | 3) NOTE: SAME, PLEASE SEE NO DISCONNECT | | | SHOWN. | | | ** PLEASE KNOW, GENERAC NOW HAS A NEW SE | | | RATED ATS ON THE MARKET WHICH WOULD MEET | | | THIS AS IT CONTAINS A MANUAL MEANS OF | | | DISCONNECT FOR THE NORMAL (FPL) SIDE AND | | | THE EM/GEN FEEDER SIDE. THIS IS NO WAY | | | SAYING THIS NEW UNIT HAS TO BE USED. | | | THIS ONLY REQUIRES A DISCONNECTING MEANS | | | AND DOES NOT REQUIRED OCP. CAN BE A | | | KNIFE TYPE SWITCH ETC. | | | | | | ** PREVIOUS REVIEW NOTE ** PLEASE SEE | | | MISSING DISCONNECT | | | FOR FEEDERS FROM GEN GROUPED WITH NEW | | | MAIN. BRKR INSIDE GEN MAY NOT SERVE AS | | | THIS DISCONNECT MEANS | | | 225.31-225.39 | | | | | | 4) NOTE: OK. | | | | | | 5) NOTE: SAME, HOWEVER PLEASE SEE A NEW | | | SURVEY IS NOW SHOWN. IF NOT USING THE | | | ODL ONE, PLEASE REMOVE FROM SETS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE SITE SURVEY SEEMS TO | | | INDICATE "EASTVIEW ELEC" ?? PLEASE | | | CLARIFY AND KNOW THAT ALL PLANS AND | | | PAPERWORK UNDER DARRYL SCHMIDT ELEC | | | SHALL BE SO STATED. | | | PLEASE SEE THAT ALL PLANS/DESIGNS | | | CONTAIN THE PRINTED NAME AND SIGNATURE | | | OF THE ELECTRICAL CONTRACTOR WHO IS | | | RESPONSIBEL FOR SAID | | | DESIGNS.106.1.2,106.3.4.3 | | | | | | 6) NOTE:OK. | | | | | | 7) NOTE: ** OK, VALUE WAS CHANGED ON | | | APPLICATION AND FEES ARE OWED BEFORE | | | PERMIT CAN BE ISSUED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THE VALUE ON PERMIT | | | APPLICATION SHALL INCLUDE ALL LABOUR AND | | | MATERIALS EVEN IF ANY | | | MATERIALS/EQUIPMENT IS OWNER SUPPLIED. | | | PLEASE SEE THIS WOULD ALSO INCLUDE THE | | | VALUE OF THE GAS WORK AS THE GAS | | | CONTRACTOR IS SIGNED ON. | | | ** PLEASE KNOW, IF AN APPROPRIATE VALUE | | | IS NOT STATED, THEN ONE WILL BE ADJUSTED | | | BY THIS OFFICE USING THE "MARSHALL'S& | | | SWIFT " GUIDE AS ADOPTED BY THE FBC | | | ADMINISTRATIVE SECTION 108.3 | | | | | | 8) NOTE: SAME, PLEASE SEE ABOVE NOTE | | | WITH RESPECT TO THE ATS BEING INSTALLED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT. | | | | | | 9) NOTE: OK. | | | | | | 10) NOTE: OK. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-23 |
Time |
18:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-23 |
Time |
18:02 |
Sent To |
M |
|
| Notes |
| 2006-06-23 00:00:00 | ******* UNSAT ******** | | | | | | | | | 1) NOTE: PLEASE SEE THAT AN "EQUIPMENT | | | GROUNDING CONDUCTOR" SHALL NOT BE | | | INSTALLED UNTIL AFTER THE FIRST MEANS OF | | | DISCONNECT. PLEASE SEE | | | 250.6,250.24B,250.122. | | | | | | 2) NOTE: PLEASE SEE THAT THE ATS AS | | | SHOWN MUST BE "SERVICE ENTRANCE RATED, | | | CONTAINING A MANUAL MEANS OF DISCONNECT | | | RATED FOR THE LOAD SERVED ETC | | | PLEASE "HIGHLIGHT" THE ATS. | | | 230.70,230.76,230.79 | | | | | | 3) NOTE: PLEASE SEE MISSING DISCONNECT | | | FOR FEEDERS FROM GEN GROUPED WITH NEW | | | MAIN. BRKR INSIDE GEN MAY NOT SERVE AS | | | THIS DISCONNECT MEANS | | | 225.31-225.39 | | | | | | 4) NOTE: PLEASE INDICATE THE OCP AT GEN | | | ON RISER AND PLEASE SHOW GEN. | | | 215.5. | | | | | | 5) NOTE: PLEASE SEE SITE SURVEY SEEMS TO | | | INDICATE "EASTVIEW ELEC" ?? PLEASE | | | CLARIFY AND KNOW THAT ALL PLANS AND | | | PAPERWORK UNDER DARRYL SCHMIDT ELEC | | | SHALL BE SO STATED. | | | PLEASE SEE THAT ALL PLANS/DESIGNS | | | CONTAIN THE PRINTED NAME AND SIGNATURE | | | OF THE ELECTRICAL CONTRACTOR WHO IS | | | RESPONSIBEL FOR SAID | | | DESIGNS.106.1.2,106.3.4.3 | | | | | | 6) NOTE: PLEASE SEE THAT THE GEN | | | LOCATION STILL NEEDS TO BE VERIFIED. | | | ALL CLEARENCES SHALL BE INDICATED FROM | | | HOUSE, WALL, ETC | | | PLEASE SEE MECH COMMENTS AND PLEASE ALSO | | | BE SURE THE MANUFACTURES SPECS/CUT | | | SHEETS INCLUDE THE MIN CLEARENCES AROUND | | | EQUIPMENT. | | | 215.5 | | | | | | 7) NOTE: PLEASE SEE THE VALUE ON PERMIT | | | APPLICATION SHALL INCLUDE ALL LABOUR AND | | | MATERIALS EVEN IF ANY | | | MATERIALS/EQUIPMENT IS OWNER SUPPLIED. | | | PLEASE SEE THIS WOULD ALSO INCLUDE THE | | | VALUE OF THE GAS WORK AS THE GAS | | | CONTRACTOR IS SIGNED ON. | | | ** PLEASE KNOW, IF AN APPROPRIATE VALUE | | | IS NOT STATED, THEN ONE WILL BE ADJUSTED | | | BY THIS OFFICE USING THE "MARSHALL'S& | | | SWIFT " GUIDE AS ADOPTED BY THE FBC | | | ADMINISTRATIVE SECTION 108.3 | | | | | | 8) NOTE: PLEASE INDICATE AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT. | | | | | | 9) NOTE: PLEASE INCLUDE ALL CONDUCTORS | | | IN RACEWAYS, INCLUDING EQUIPMENT | | | GROUNDING CONDUCTORS. | | | 250.110,250.24B,250.122,240.4,310.16 | | | | | | 10) NOTE: PLEASE PROVIDE A LAYOUT FOR | | | ALL EQUIPMENT AND LOCATIONS AT DWELLING. | | | PLEASE SEE ATS DOES NOT INDICATE FEED TO | | | WHAT IS ASSUMED TO BE AN EXISTING PANEL | | | SOMEWHERE. | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-20 |
Time |
10:05 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-09-20 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-09-01 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-09-01 |
Time |
16:48 |
Sent To |
M |
|
| Notes |
| 2006-09-01 00:00:00 | REFERENCE: GAS PERMIT #06061005 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-03 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-08-03 |
Time |
09:14 |
Sent To |
B |
|
| Notes |
| 2006-08-03 00:00:00 | REFERENCE: GAS PERMIT #06061005 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-06-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-29 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-06-29 |
Time |
08:21 |
Sent To |
B |
|
| Notes |
| 2006-06-29 00:00:00 | NOTE: REFERENCE GAS PERMIT APPLICA- | | | TION #06061005 FOR DENIED COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
13:50 |
Sent To |
Z |
|
| Notes |
| 2006-09-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-24 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-24 |
Time |
14:05 |
Sent To |
E |
|
| Notes |
| 2006-08-24 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-18 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-18 |
Time |
16:03 |
Sent To |
Z |
|
| Notes |
| 2006-08-18 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-01 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
15:44 |
Sent To |
Z |
|
| Notes |
| 2006-08-01 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-23 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-23 |
Time |
10:02 |
Sent To |
E |
|
| Notes |
| 2006-06-23 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-06-29 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-06-20 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-20 |
Time |
10:40 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-20 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2006-09-20 00:00:00 | RETURNED TO LUIS M. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-05 |
Time |
08:16 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-09-05 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | *** DENIED *** | | | 1) PLEASE SEE ELECTRICAL AND GAS REVIEW | | | NOTES AND CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-03 |
Time |
11:09 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-08-03 |
Time |
11:09 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-26 |
Time |
15:34 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-06-26 |
Time |
15:34 |
Sent To |
P |
|
| Notes |
| 2006-06-26 00:00:00 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | PROVIDE MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AT THE JOBSITE FOR THE | | | FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-18 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-18 |
Time |
17:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-23 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-23 |
Time |
18:01 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-08-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2006-08-03 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2006-08-03 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2006-08-03 00:00:00 | SUBMIT PREVIOUSLY APPROVED | | | SURVEYS/SITEPLANS | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-22 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-22 |
Time |
16:06 |
Sent To |
I |
|
| Notes |
| 2006-06-22 00:00:00 | NOTE: GENERATOR WILL BE 3.6FT FROM SIDE | | | PROPERTY LINE AND MUUST BE LANDSCAPE | | | BUFFER AROUND GENERATOR. | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-22 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-22 |
Time |
09:50 |
Sent To |
I |
|
| Notes |
| 2006-06-22 00:00:00 | NOTE: WAITING FOR HOA APPROVAL & SETBACK | | | INFORMATION.WILL BE FAXED TODAY. | | | CALLED TO CLARIFY ON THE SETBACK, LEFT | | | MSG. | | | DENIED, | | | 1. MUST PROVIDE COPY OF THE HOA APPROVAL | | | FOR THE GENERATOR | | | 2. THE PROPOSED GENERATOR WILL BE 4.6FT | | | FROM SIDE PROPERTY LINE. | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | |
|
|