Plan Review Details - Permit 06060985
| Plan Review Stops For Permit 06060985 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-04 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-07-04 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-07-04 |
Time |
08:28 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-23 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-23 |
Time |
13:25 |
Sent To |
PC |
|
| Notes |
| 2006-07-23 00:00:00 | **** REDLINED PLANS *** | | | | | | ENGINEER NOTED AND DATED PLANS,PLANS | | | ARE NOTED AS PANEL BEING EXISTING, | | | HOWEVER THIS IS TO BE VERIFIED IN FIELD. | | | IF POOL PANEL IS NEW, THEN PLANS SHALL | | | BE REVISED WITH INFORMATION AS | | | PREVIOUSLY REQUESTED. | | | | | | ENG ALSO CHANGED THE #10 AWG FOR PUMP TO | | | #12 AWG. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO | | | NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-27 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-27 |
Time |
19:40 |
Sent To |
P |
|
| Notes |
| 2006-06-27 00:00:00 | ***** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTOR FROM EXISTING | | | SERVICE TO NEW PANEL. | | | 250.110,250.122, 680.6 | | | | | | 2) NOTE: PLEASE PROVIDE LOAD | | | CALCULATIONS AND PANEL SCHEDULE OF | | | EXISTING SERVICE WHICH INDICATE THE NEW | | | OCP FOR POOL PANEL AND NEW LOAD ADDED TO | | | EXISTING LOAD. | | | 408.4,220.31 | | | ** PLEASE KNOW, THIS MAY BE PROVIDED BY | | | THE ELECTRICAL CONTRACTOR AND IS NOT | | | REQUIRED BY CURTIS- SINCLAIR. | | | | | | | | | 3) NOTE: PLEASE VERIFY 3-#10'S TO 1HP | | | POOL PUMP. *THIS IS OK, HOWEVER VERIFY | | | AS IF PLANS INDICATE #10, THEN THESE | | | WILL BE REQUIRED. | | | 215.5 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-23 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-21 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2006-07-21 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-27 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-27 |
Time |
11:16 |
Sent To |
E |
|
| Notes |
| 2006-06-27 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-19 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-28 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-06-28 |
Time |
13:56 |
Sent To |
B |
|
| Notes |
| 2006-06-28 00:00:00 | NOTE: PLUMBING PERMIT REQUIRED |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-25 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-25 |
Time |
14:06 |
Sent To |
I |
|
| Notes |
| 2006-06-25 00:00:00 | NOTE: | | | THE PROPOSED POOL EQUIPMENT SHALL NOT BE | | | CLOSER THAN 4'3 FROMSIDE PROPERTY | | | LINE. | | | NOTE: THE PROPOSED POOL/DECK IS BEYOND | | | THE 25FT FRONT SETBACK (AS SHOWN ON | | | SURVEY) | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. |
|
|
|