Plan Review Details - Permit 06060973
| Plan Review Stops For Permit 06060973 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-05 |
Time |
16:37 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-07-05 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | DENIED | | | | | | 1.SUBMIT ORIGONAL SIGNED AND SEALED | | | CALCULATIONS FROM HILLMAN ENGINEERING. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-06-30 |
Time |
18:03 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-06-30 |
Time |
17:22 |
Sent To |
G |
|
| Notes |
| 2006-06-30 00:00:00 | NONCOMPLIANT | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE VALUE ON THE APPLICATION MUST | | | INCLUDE THE COST OF LABOR AND MATERIAL | | | FOR THE INSTALLATION OF ALL COMPONENTS | | | UNDER THE COPE OF THIS PERMIT. FBC | | | 108.3. | | | | | | 2} PLEASE LOCATE ALL SERVICE EQUIPMENT | | | ON THE PLAN, METER ENCLOSURE, GENERATOR, | | | TRANSFER SWITCH, DISCONNECTS AND PANELS, | | | SO THAT COMPLIANCE WITH ARTICLES 225 AND | | | 230 CAN BE REVIEWED. | | | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | | THE DESIGN MUST PRINT AND SIGN THEIR | | | NAME TO SAME PER 106.3.4.2. | | | | | | 4} PROVIDE A LOAD CALCULATIION FOR THE | | | LOAD BEING SERVED BY THE GENERATOR. IF | | | USING 220.35, SHOW THE CALCULATION, NOT | | | JUST WATTHOURS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-07-03 |
Time |
10:26 |
Rev Time |
0.15 |
| Received By |
mperson |
Date |
2006-07-03 |
Time |
10:26 |
Sent To |
B |
|
| Notes |
| 2006-07-03 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-27 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-27 |
Time |
09:36 |
Sent To |
E |
|
| Notes |
| 2006-06-27 00:00:00 | TO "GEN-RES" BOX "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-05 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-19 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-25 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-25 |
Time |
14:01 |
Sent To |
I |
|
| Notes |
| 2006-06-25 00:00:00 | | | | DENIED, | | | 1. NEED TO SHOW THE LOCATION OF THE | | | PROPOSED GENERATOR CLEARLY ON TWO COPY | | | OF CURRENT SURVEY WITH THE DIMENSION OF | | | PROPOSED GENERATOR. | | | 2. NEED TO SHOW THE SETBACK OF THE | | | STRUCTURE ON THE TWO COPY OF CURRENT | | | SURVEY. | | | NOTE: SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
|