Plan Review Details - Permit 06060805
Plan Review Stops For Permit 06060805
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-11-02 Cont ID  
Sent By rmcdouga Date 2006-11-02 Time 12:59 Rev Time 0.00
Received By rmcdouga Date 2006-11-02 Time 12:59 Sent To  
Notes
2006-11-02 13:00:11REVISION TO CHANGE SCOPE OF WORK IS OK. SCOPE HAS BEEN
 CHANGED FROM RECOVERING FLAT DECK AND SLOPED ROOF TO
 REPAIRING EXISTING SLOPE ROOF.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-08-16 Cont ID  
Sent By kconrad Date 2006-08-16 Time 14:51 Rev Time 0.00
Received By kconrad Date 2006-08-16 Time 14:51 Sent To I
Notes
2006-08-16 00:00:00PREINSPECT OK FOR RECOVER OF EXISTING
 ROOF DECK. VERIFIED BY DN.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-14 Cont ID  
Sent By rmcdouga Date 2006-08-14 Time 12:53 Rev Time 0.00
Received By rmcdouga Date 2006-08-14 Time 12:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-14 Cont ID  
Sent By rmcdouga Date 2006-06-14 Time 08:43 Rev Time 0.00
Received By rmcdouga Date 2006-06-14 Time 08:43 Sent To  
Notes
2006-06-14 00:00:00DENIED
  
 1) THE JOHNS MANVILLE EPDH SINGLE PLY
 ROOF SYSTEM OVER RECOVER DECKS PRODUCT
 APPROVAL SPECIFIES A MAXIMUM DESIGN
 PRESSURE OF -75 WITH INCREASE ALLOWED
 PER LIMITATION #9 ON PAGE 12. THIS
 DESIGN PRESSURE IS TOO LOW. SEE 2004 FBC
 TABLE 1609.6B FOR COMPONENT AND CLADDING
 WINDLOAD PRESSURES.
  
 2) WHEN MULTIPLE ROOF ASSEMBLIES AND
 FASTENING OPTIONS ARE SPECIFIED IN THE
 PRODUCT APPROVAL PLEASE INDICATE THE ONE
 THAT WILL BE USED.
  
 3) RECOVER OR ROOFOVERS REQUIRE THE
 EXISTING ROOF TO BE INSPECTED BY A
 BUILDING INSPECTOR BEFORE THE PERMIT CAN
 BE ISSUED. PLEASE INFORM THE PERMIT
 CLERK AT THE FRONT COUNTER WHEN
 SUBMITTING FOR PERMIT SO THAT THE
 APPLICATION CAN BE ROUTED TO THE
 APPROPRIATE PERSONNEL.
  
 4)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
 WWW.FLORIDABUILDING.ORG
 IF THE PRODUCT HAS STATE PRODUCT
 APPROVAL INDICATE THE STATE FL #.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-11-02 Cont ID  
Sent By adarroug Date 2006-11-02 Time 10:39 Rev Time 0.00
Received By adarroug Date 2006-11-02 Time 10:39 Sent To B
Notes
2006-11-02 10:39:40TO "RMCDOUGAL" DESK/REV