Plan Review Details - Permit 06060787
Plan Review Stops For Permit 06060787
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-08-17 Cont ID  
Sent By rnuquist Date 2006-08-17 Time 17:41 Rev Time 0.00
Received By rnuquist Date 2006-08-17 Time 17:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-06 Cont ID  
Sent By rnuquist Date 2006-08-06 Time 16:30 Rev Time 0.00
Received By rnuquist Date 2006-08-06 Time 16:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-11 Cont ID  
Sent By rnuquist Date 2006-07-11 Time 21:55 Rev Time 0.00
Received By rnuquist Date 2006-07-11 Time 21:55 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-14 Cont ID  
Sent By dpalmer Date 2006-08-14 Time 19:47 Rev Time 0.00
Received By dpalmer Date 2006-08-14 Time 19:47 Sent To P
Notes
2006-08-14 00:00:00PANEL ON PLANS IS EXISTING PER
 CONTRACTOR. VIF.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-08-01 Cont ID  
Sent By dpalmer Date 2006-08-01 Time 12:05 Rev Time 0.00
Received By dpalmer Date 2006-08-01 Time 12:05 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-22 Cont ID  
Sent By dpalmer Date 2006-06-22 Time 20:01 Rev Time 0.00
Received By dpalmer Date 2006-06-22 Time 19:49 Sent To P
Notes
2006-06-22 00:00:00******** UNSAT *********
  
  
 1) NOTE: PLEASE CORRELATE PLANS FOR ALL
 EQUIPMENT, CONDCUCTORS SIZES ETC.
 215.5
 PLEASE SEE PLANS INDICATE AN ELECTRIC
 HEAT PUMP, YET RISER SHOWS ONLY #12'S?
 PLEASE SEE POOL PUMP INDICATES 3-8'S??
 PLEASE KNOW THAT 3-#8'S WILL NOT CONNECT
 INSIDE A 1 1/2 HP PUMP.
  
 2) NOTE: PLEASE SEE DIAGRAM SHOWS A NEW
 POOL PANEL YET NO OCP IS SHOWN FROM
 EXISTING LOCATION ETC.
 215.5
  
 3) NOTE: PLEASE SEE MORE THAN ONE
 LOCATION WHICH INDICATES 3-#8'S IN A
 1/2" CONDUIT? PLEASE SEE MISSING
 EQUIPMENT GROUNDING CONDUCTORS IN MORE
 THAN ONE OF THESE CONDUITS. PLEASE SEE
 680, 250.110,250.122 ETC FOR GROUNDING.
 PLEASE SEE TABLES 9 FOR MAX CONDUIT
 FILL.
  
 4) NOTE: PLEASE SUBMIT COMPLETE LOAD
 CALCULATIONS FOR ALL NEW EQUIPMENT BEING
 ADDED TO EXSITIGN SERVICE. PLEASE BE
 SURE ALL CONTINUOUS LOADS ARE SHOWNAT
 125%. 215.3,230.42,680.9
 PLEASE ALSO INDICATE SIZE OF EXISTING
 SERVICE.
 215.5,220.31B
  
 5) NOTE: PLEASE SUBMIT MANUFACTURES
 SPECS/ CUT SHEETS FOR NEW PROPOSED HEAT
 PUMP. ALL MUST INDICATE THE LISTING FROM
 A NRTL.
 110.3
  
 ** PLEASE KNOW, ALL OVERHEAD POWER LINES
 SHALL MEET 680.8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-08-02 Cont ID  
Sent By mperson Date 2006-08-02 Time 11:03 Rev Time 0.00
Received By mperson Date 2006-08-02 Time 11:03 Sent To B
Notes
2006-08-02 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-06-13 Cont ID  
Sent By ssherman Date 2006-06-13 Time 13:12 Rev Time 0.00
Received By ssherman Date 2006-06-13 Time 13:12 Sent To  
Notes
2006-06-13 00:00:00HISTORIC APPROVAL PER T PAPA

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-14 Cont ID  
Sent By adarroug Date 2006-08-14 Time 16:55 Rev Time 0.00
Received By adarroug Date 2006-08-14 Time 16:55 Sent To E
Notes
2006-08-14 00:00:00TO "DPALMER" DESK/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-31 Cont ID  
Sent By adarroug Date 2006-07-31 Time 11:53 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 11:53 Sent To E
Notes
2006-07-31 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-24 Cont ID  
Sent By adarroug Date 2006-07-24 Time 08:54 Rev Time 0.00
Received By adarroug Date 2006-07-24 Time 08:54 Sent To Z
Notes
2006-07-24 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-20 Cont ID  
Sent By adarroug Date 2006-06-20 Time 08:48 Rev Time 0.00
Received By adarroug Date 2006-06-20 Time 08:48 Sent To E
Notes
2006-06-20 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-12 Cont ID  
Sent By adarroug Date 2006-07-11 Time 16:17 Rev Time 0.00
Received By adarroug Date 2006-06-15 Time 13:17 Sent To  
Notes
2006-06-15 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-08-15 Cont ID  
Sent By mperson Date 2006-08-15 Time 08:37 Rev Time 0.33
Received By mperson Date 2006-08-15 Time 08:37 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-08-02 Cont ID  
Sent By mperson Date 2006-08-02 Time 10:45 Rev Time 0.33
Received By mperson Date 2006-08-02 Time 10:45 Sent To G
Notes
2006-08-02 00:00:00******DENIED 2ND TIME******
 REFERENCE: FBC-2004 424.2 SWIMMING POOLS
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED
 FOR PLUMBING PLAN REVIEW: (NOTE: THIS IS
 A NEW COMMENT DUE TO THE NEW SHEETS)
  
 1) PLEASE CORRELATE THE EQUIPMENT LAYOUT
 WITH THE LEGEND. THE 1 HP AIR BLOWER IS
 MISSING FROM THE LEGEND CAUSING THE
 OTHER ITEMS IN THE LEGEND TO BE
 MISLABELED. PLEASE SEE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR RESUBMIT-
 TAL. (NOTE: ONLY ONE DRAWING CORRECTED
 IN RED INK)
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-23 Cont ID  
Sent By mperson Date 2006-06-23 Time 13:39 Rev Time 0.33
Received By mperson Date 2006-06-23 Time 13:38 Sent To B
Notes
2006-06-23 00:00:00******DENIED******
 REFERENCE: FBC-2004 SEC. 424.2 OR
 FBC-2004 RESIDENTIAL SEC. R4101 SWIMMING
 POOLS:
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW:
  
 1) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
 2) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-07-29 Cont ID  
Sent By mmclean Date 2006-07-29 Time 09:53 Rev Time 0.00
Received By mmclean Date 2006-07-29 Time 09:53 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-06-18 Cont ID  
Sent By mmclean Date 2006-06-18 Time 18:22 Rev Time 0.00
Received By mmclean Date 2006-06-18 Time 18:22 Sent To I
Notes
2006-06-18 00:00:00DENIED,
 1. MUST PROVIDE THE REAR SETBACK OF THE
 PROPOSED POOL EQUIPMENT FROM THE
 PROPERTY LINE.
  
 SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved