| Plan Review Stops For Permit 06060787 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-08-17 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-08-17 |
Time |
17:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-06 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-08-06 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-08-06 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-07-11 |
Time |
21:55 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-07-11 |
Time |
21:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-14 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-14 |
Time |
19:47 |
Sent To |
P |
|
| Notes |
| 2006-08-14 00:00:00 | PANEL ON PLANS IS EXISTING PER | | | CONTRACTOR. VIF. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-01 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-01 |
Time |
12:05 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-22 |
Time |
20:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-22 |
Time |
19:49 |
Sent To |
P |
|
| Notes |
| 2006-06-22 00:00:00 | ******** UNSAT ********* | | | | | | | | | 1) NOTE: PLEASE CORRELATE PLANS FOR ALL | | | EQUIPMENT, CONDCUCTORS SIZES ETC. | | | 215.5 | | | PLEASE SEE PLANS INDICATE AN ELECTRIC | | | HEAT PUMP, YET RISER SHOWS ONLY #12'S? | | | PLEASE SEE POOL PUMP INDICATES 3-8'S?? | | | PLEASE KNOW THAT 3-#8'S WILL NOT CONNECT | | | INSIDE A 1 1/2 HP PUMP. | | | | | | 2) NOTE: PLEASE SEE DIAGRAM SHOWS A NEW | | | POOL PANEL YET NO OCP IS SHOWN FROM | | | EXISTING LOCATION ETC. | | | 215.5 | | | | | | 3) NOTE: PLEASE SEE MORE THAN ONE | | | LOCATION WHICH INDICATES 3-#8'S IN A | | | 1/2" CONDUIT? PLEASE SEE MISSING | | | EQUIPMENT GROUNDING CONDUCTORS IN MORE | | | THAN ONE OF THESE CONDUITS. PLEASE SEE | | | 680, 250.110,250.122 ETC FOR GROUNDING. | | | PLEASE SEE TABLES 9 FOR MAX CONDUIT | | | FILL. | | | | | | 4) NOTE: PLEASE SUBMIT COMPLETE LOAD | | | CALCULATIONS FOR ALL NEW EQUIPMENT BEING | | | ADDED TO EXSITIGN SERVICE. PLEASE BE | | | SURE ALL CONTINUOUS LOADS ARE SHOWNAT | | | 125%. 215.3,230.42,680.9 | | | PLEASE ALSO INDICATE SIZE OF EXISTING | | | SERVICE. | | | 215.5,220.31B | | | | | | 5) NOTE: PLEASE SUBMIT MANUFACTURES | | | SPECS/ CUT SHEETS FOR NEW PROPOSED HEAT | | | PUMP. ALL MUST INDICATE THE LISTING FROM | | | A NRTL. | | | 110.3 | | | | | | ** PLEASE KNOW, ALL OVERHEAD POWER LINES | | | SHALL MEET 680.8 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-02 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2006-08-02 |
Time |
11:03 |
Sent To |
B |
|
| Notes |
| 2006-08-02 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
ssherman |
Date |
2006-06-13 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
ssherman |
Date |
2006-06-13 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2006-06-13 00:00:00 | HISTORIC APPROVAL PER T PAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
16:55 |
Sent To |
E |
|
| Notes |
| 2006-08-14 00:00:00 | TO "DPALMER" DESK/RESUB--NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
11:53 |
Sent To |
E |
|
| Notes |
| 2006-07-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-24 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-24 |
Time |
08:54 |
Sent To |
Z |
|
| Notes |
| 2006-07-24 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-20 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
08:48 |
Sent To |
E |
|
| Notes |
| 2006-06-20 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-11 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-15 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-15 |
Time |
08:37 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-08-15 |
Time |
08:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-08-02 |
Time |
10:45 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-08-02 |
Time |
10:45 |
Sent To |
G |
|
| Notes |
| 2006-08-02 00:00:00 | ******DENIED 2ND TIME****** | | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED | | | FOR PLUMBING PLAN REVIEW: (NOTE: THIS IS | | | A NEW COMMENT DUE TO THE NEW SHEETS) | | | | | | 1) PLEASE CORRELATE THE EQUIPMENT LAYOUT | | | WITH THE LEGEND. THE 1 HP AIR BLOWER IS | | | MISSING FROM THE LEGEND CAUSING THE | | | OTHER ITEMS IN THE LEGEND TO BE | | | MISLABELED. PLEASE SEE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR RESUBMIT- | | | TAL. (NOTE: ONLY ONE DRAWING CORRECTED | | | IN RED INK) | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-06-23 |
Time |
13:39 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-06-23 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2006-06-23 00:00:00 | ******DENIED****** | | | REFERENCE: FBC-2004 SEC. 424.2 OR | | | FBC-2004 RESIDENTIAL SEC. R4101 SWIMMING | | | POOLS: | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW: | | | | | | 1) FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | 2) FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-29 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-07-29 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-07-29 |
Time |
09:53 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-18 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-18 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-18 |
Time |
18:22 |
Sent To |
I |
|
| Notes |
| 2006-06-18 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE REAR SETBACK OF THE | | | PROPOSED POOL EQUIPMENT FROM THE | | | PROPERTY LINE. | | | | | | SEC 94-303 MECHANICAL/POOL | | | EQUIPMENT/GENERATOR MAY NOT PROJECT MORE | | | THAN FOUR FEET INTO A SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 | | | | | | |
|
|