| Plan Review Stops For Permit 06060708 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-10-05 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-10-05 |
Time |
14:02 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-09-01 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-09-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | | | | | | | DENIED HOLD AT DESK FOR SUBMITAL OF MORE | | | INFORMATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-08-08 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-08-08 |
Time |
11:49 |
Sent To |
PC |
|
| Notes |
| 2006-08-08 00:00:00 | | | | | | | DENIED | | | | | | 1) PLEASE SEE THAT THERE ARE MANY | | | DISCREPANCIES ON 2/2 OF DRAWINGS BETWEEN | | | THE FRAMING PLAN AND SECTIONS C-C AND | | | D-D | | | SECTION C-C SHOWS PURLINS D-D OUT | | | LOOKERS, BEAM HT ON C-C AND D-D DO NOT | | | MAKE SENSE SEE THAT RAFTERS SIT ON BEAM | | | AT 7'-3" C-C AND TOP OF RAKE BEAM D-D IS | | | ALSO 7'-3" AT THE EAVE. MEANWHILE | | | FRAMING PLAN STATES 6'-5" BEAM ELEV. 2 | | | DIFFERINGSTIRRUP DETAILS ON D-D, C-C | | | SHOWS SPAN OF 18'-3" WHILE D-D HAS THAT | | | FOR HALF THE SPAN. PLEASE BE AWARE BEAM | | | IS 14 INCHES AND RAFTERS ARE 2X12 | | | (11 1/4") | | | BEAM SCHEDULE HAS BEAMS 8X14 C-C AND D-D | | | STATES 12X14 | | | ALSO SEE ON PAGE 1/2 A-A AND S-S HAVE | | | DIFFERENT ELEVATIONS | | | | | | 2) HOW DOES NEW ROOF FRAMING ATTACH TO | | | EXISTING STRUCTURE | | | | | | 3) NORTH ELEVATION SHOWS FRENCH DOORS AS | | | EXISTING BUT EXISTING FLOOR PLAN AND NEW | | | FLOOR PLAN SHOW NEW DOORS AND SIDELITES | | | PLEASE CLARIFY IF THEY ARE NEW PRODUCT | | | APPROVALS WILL BE REQUIRED | | | *****PLEASE CLARIFY ALL OF ABOVE****** | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-04 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-04 |
Time |
09:09 |
Rev Time |
1.00 |
| Received By |
amorse |
Date |
2006-07-04 |
Time |
09:09 |
Sent To |
PC |
|
| Notes |
| 2006-07-04 00:00:00 | | | | | | | DENIED | | | | | | 1) THE CLAIMED VALUATION ON THE PERMIT | | | APPLICATION IS LOW. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND | | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | | AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* THE PERMIT VALUE WILL BE | | | ADJUSTED AND FEES DUE | | | | | | 2) THE STATE OF FLORIDA REQUIRES | | | COLLECTION OF A RADON SURCHARGE ON ALL | | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | | FLOOR SPACE PER 10D-91 FAC | | | | | | 3) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | | APPLICATION OR BEFORE INSTALLATION | | | | | | 4) PRODUCT APPROVALS FOR ROOF TILES AND | | | POLYFOAM ARE EXPIRED PLEASE SUBMIT | | | UPDATED FLORIDA COVERS AND NOA'S | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-05 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-05 |
Time |
14:24 |
Sent To |
B |
|
| Notes |
| 2006-10-05 00:00:00 | RE-STAMP |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-27 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-27 |
Time |
11:23 |
Sent To |
B |
|
| Notes |
| 2006-08-27 00:00:00 | NEW SHEETS WITH ELECTRICAL, VOIDED | | | PERVIOUS ELECTRICAL AND STAMPED NEW | | | SHEETS AS ELECTRICAL PASSED THE PREVIOUS | | | REVIEW AND IS THE SAME ON THIS REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-26 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-26 |
Time |
08:12 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-24 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-24 |
Time |
11:51 |
Sent To |
E |
|
| Notes |
| 2006-08-24 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
14:33 |
Sent To |
B |
|
| Notes |
| 2006-08-07 00:00:00 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-01 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-01 |
Time |
13:41 |
Sent To |
Z |
|
| Notes |
| 2006-08-01 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
16:37 |
Sent To |
E |
|
| Notes |
| 2006-06-25 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-14 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2006-06-14 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-26 |
Time |
08:26 |
Rev Time |
|
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-06-26 00:00:00 | NO MECH IN SCOPE OF WORK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-26 |
Time |
08:26 |
Rev Time |
|
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-06-26 00:00:00 | NO PLUMB IN SCOPE OF WORK |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-05 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-05 |
Time |
09:03 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-23 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-23 |
Time |
07:39 |
Sent To |
I |
|
| Notes |
| 2006-06-23 00:00:00 | DENIED, | | | 1. NEED TO PROVIDE THE REAR SETBACK OF | | | THE PROPOSED REAR PORCH ON TWO COPY OF | | | CURRENT SURVEY. | | | 2. SETBACK IS NOT SHOWN ON THE SURVEY | | | SUBMITTED. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|