| Plan Review Stops For Permit 06060672 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-28 |
Time |
16:19 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2007-03-28 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2007-03-28 16:20:49 | REVISION :STORM SHUTTERS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-16 |
Time |
13:33 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-03-16 |
Time |
13:33 |
Sent To |
PC |
|
| Notes |
| 2007-03-16 13:38:47 | BUILDING PLAN REVIEW | | | PERMIT: 06060672 | | | ADD: 2101 OKEECHOBEE BLVD | | | CONT: ROEPNACK | | | TEL: (954)444-2995 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1STREVIEWSTORM SHUTTERS | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 3) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 4)FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | NOTE : SHUTTERS CAN ONLY BE INSTALLED HORIZONTALLY | | | BECAUSE OF THE FRAMING!!!!!!! | | | PROVIDE A KEY PLAN INDICATING THE OPENINGS!!!! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-16 |
Time |
13:01 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2007-03-16 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2007-03-16 13:01:50 | NEW PLANS STATE APPROVAL WITH FOUNDATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-06 |
Time |
11:40 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-02-06 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2007-02-06 12:28:10 | BUILDING PLAN REVIEW | | | PERMIT: 06060672 | | | ADD: 2101 OKEECHOBEE BLVD | | | CONT: ROEPNACK CORP | | | TEL: (954)444-2995 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)STATE APPROVED PLANS DO NOT SHOW UP ON THE STATE | | | WEB SITE, I CALLED THE STATE TO VERIFY THE MDS THIRD | | | PARTY LISTING AGENCYS PLAN NUMBER. | | | IT APPEARS THESE ARE MODIFICATIONS TO THE STATE | | | APPROVED PLANS WHICH WILL NOT SHOW UP ON THE WEB SITE. | | | IN DISCUSSING THE PLANS WITH THE PROGRAM DIRECTOR | | | MICHAEL ASHWORTH (850) 922-6075 ABOUT WHEN THE THIRD | | | PARTY AGENCY MDS PLACES THE DATE OF 1-09-2007 THAT THE | | | | | | UNIT IS TO BE BUILT TO THE 2004 FBC WITH THE 2005 AND | | | 2006 FBC REVISIONS. | | | 2A) THE ISSUE OF THE PLANS INDICATING BEING UNDER THE | | | 2004 AND THE ASCE 7-98 ARE INCORRECT. | | | 2B) VARIOUS SHEETS SHEET 3 OF 4 SHOWA 130 WIND SPEED | | | INSTEED OF THE CORRECT 140 MILE PER HR HIGHWIND | | | DEBRIS REGION. | | | 2C) PLANS INDICATE A TYPE V BUILDING WHICH REFLECTS THE | | | 2001FBC OR OLDER. CURRENTLY A TYPE VBUILDING IS A TYPE | | | VA OR VB. | | | 2D) PLANS ALSO DO NOT PROVIDE THE EXPOSURE CATEGORY. | | | | | | 3) THE ISSUE OF THE MANUFACTURED BUILDINGS CAN DEFER | | | THE STORM SHUTTERS TO BE INSTALLED AT THE JOBSITE | | | (SHEET# 1 NOTE# 16) DOES MEAN THAT IT CAN AND WILL BE | | | REVIEWED BY THE LOCAL JURISDICTION. | | | PLEASE PROVIDE STATE APPROVALS FOR STORM SHUTTERS: | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | THE NEXT ISSUE OF STORM SHUTTERS WILL BETHE WINDOW | | | FRAME DESIGN APPROVED BY THE STATE | | | DOESN'T PROVIDE FOR SECURING TO THE BOTTOM FRAMING | | | MEMBER OR WINDOW SILLWHEN TURNED ON EDGE. | | | PLEASE RESPOND HOW CODE COMPLIANCE WILL BE MET? | | | | | | 4) THIS STRUCTURE IS BEING REVIEWED AS A PERMANENT | | | STTRUCTURE REQUIRING A FULL FOUNDATION. | | | 1805.2 DEPTH OF FOOTINGS. | | | THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED | | | GROUND SURFACE SHALL BE 12 INCHES (305 MM). WHERE | | | APPLICABLE, THE DEPTH OF FOOTINGS SHALL ALSO CONFORM TO | | | SECTIONS 1805.2.1 THROUGH 1805.2.3 . | | | | | | 5) FOUNDATION SHALL BE DESIGNED TO THESE CRITERIA: | | | 2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-22 |
Time |
17:50 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-01-22 |
Time |
17:41 |
Sent To |
PC |
|
| Notes |
| 2007-01-22 17:53:29 | BUILDING PLAN REVIEW | | | PERMIT: 06060672 | | | ADD: 2101 OKEECHOBEE BLVD | | | CONT: ROEPNACK | | | TEL: (954)444-2995 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) PLEASE SEE ELECTRICAL COMMENT FOR GROUNDING | | | ELECTRODE. | | | STRUCTURALLY PLANS ARE OK. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-01-02 |
Time |
13:49 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-01-02 |
Time |
13:49 |
Sent To |
PC |
|
| Notes |
| 2007-01-02 13:50:34 | DUMPSTER WALL IN SECTION INDICATING STEEL LAYOUT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-13 |
Time |
10:11 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2006-11-13 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-03 |
Time |
13:51 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2006-10-03 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | 10-03-06 SHEET 4OF 4 FOUNDATION PLAN AND | | | A-101 ACCESIBLITY RAMP. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-08 |
Time |
08:48 |
Rev Time |
1.77 |
| Received By |
jwitmer |
Date |
2006-08-08 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2006-08-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06060672 | | | ADD: 2101 OKEECHOBEE BLVD | | | CONT: ROEPNACK CORPORATION | | | TEL: (954)691-2400 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | --- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | NOTE!FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 1) MANUFACTURED BLDG PLANS APPROVED BY | | | THE STATE ARE SHEETS 1-3. SHEET 4 IS THE | | | FOUNDATION THAT MUST COMPLY WITH THE | | | CODE IN EFFECT TODAY AS STATED ON SHEET | | | # 4. SHEET # 4THAT THE FOUNDATION WAS | | | DESIGNED UNDER THE 2004 FBC WRONG | | | EDITION OF ASCE 7-(98).2004 FBC USES | | | ASCE 7-02.SEE CHAPTER 35. | | | | | | 2) A-101 THE HANDICAPPED RAMP LOWER | | | LANDING IS MISSING THE 72" REQUIRED | | | LANDING.11-4.8.4.(2) LANDINGS. ALL | | | LANDINGS ON RAMPS SHALL NOT BE LESS THAN | | | 60" CLEAR, & THE BOTTOM OF EACH RAMP | | | SHALL HAVE NOT LESS THAN 72" OF STRAIGHT | | | & LEVEL CLEARENCE. | | | | | | 3) A-101 GUARDRAIL/ HANDRAIL DETAIL | | | INDICATES 2 1/4" CLEAR BETWEEN THE | | | GUARDRAIL AND HANDRAIL.11-4.8.5(3) THE | | | CLEAR SPACE BETWEEN THE HANDRAIL AND THE | | | WALL SHALL BE 1? INCHES (38 MM). | | | | | | 4) A-101 THE HANDRAIL ON BOTH THE FRONT | | | AND REAR STAIR NEED TO BE RECONFIGURED | | | TO THE DESIGN FOUND IN THE @004 FBC | | | FIGURE 11-19A. | | | 11-9.4(2) HANDRAILS:2)IF HANDRAILS | | | ARE NOT CONTINUOUS, THEY SHALL EXTEND AT | | | LEAST 12 INCHES (305 MM) BEYOND THE TOP | | | RISER AND AT LEAST 12 INCHES (305 MM) | | | PLUS THE WIDTH OF ONE TREAD BEYOND THE | | | BOTTOM RISER. AT THE TOP, THE EXTENSION | | | SHALL BE PARALLEL WITH THE FLOOR OR | | | GROUND SURFACE. AT THE BOTTOM, THE | | | HANDRAIL SHALL CONTINUE TO SLOPE FOR A | | | DISTANCE OF THE WIDTH OF ONE TREAD FROM | | | THE BOTTOM RISER; THE REMAINDER OF THE | | | EXTENSION SHALL BE HORIZONTAL [SEE | | | FIGURE 11-19 (C) AND FIGURE 11-19 (D)]. | | | HANDRAIL EXTENSIONS SHALL COMPLY WITH | | | SECTION 11-4.4 . | | | | | | 5) CANOPY IN THE FRONT OF THE OFFICE | | | TO BE UNDER A SEPERATE PERMIT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
P |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-14 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-14 |
Time |
16:03 |
Sent To |
B |
|
| Notes |
| 2007-02-14 16:05:22 | DECREASED SERVICE TO 400AMPS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2007-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-03 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-03 |
Time |
12:41 |
Sent To |
PC |
|
| Notes |
| 2007-02-03 12:45:17 | ** NOTES /UNSAT ** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW WHICH | | | STATES THE SERVICE ENTRANCE CONDUCTORS NEEDS TO BE | | | UPDATED, HOWEVER THE INFORMATION GIVEN TO THE OFFICE | | | WAS THAT THE MDP WAS GOING TO BE DECREASED AND THE | | | LOADS PERMITTED THIS. PLEASE SEE THE REVISED SHEETS | | | WHICH ARE TO DECREASE THE MDP WERE NOT SUBMITTED. | | | PLEASE REVISE AND SUBMIT FOR REVIEW. | | | | | | ** IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE | | | IN CONTACTING THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-01-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-28 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-28 |
Time |
16:52 |
Sent To |
PC |
|
| Notes |
| 2007-01-28 17:20:09 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS | | | WHICH WERE PREVIOUSLY SIZED AT 760AMPS ARE NOW ONLY | | | BEING RATED FOR 510AMPS. PLEASE SEE 240.4, 310.16 AS | | | THESE ARE NOT RATED FOR THE LOAD OR SERVICE ORIGINALLY | | | SUBMITTED. THE MDP IS 800AMPS AND THE PREVIOUS SERVICE | | | ENTRANCE CONDUCTORS WERE RATED FOR 760AMPS. | | | | | | 2) NOTE: PLEASE SEE VOLTAGE DROP CALCULATIONS WERE | | | PREVIOUSLY BASED ON COPPER CONDUCTORS AND OF A | | | DIFFERENT SIZE. PLEASE REVISED CALCULATIONS AS NEEDED. | | | 13-413.1 | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW AS IT APPEARS THESE | | | BUILDINGS/TRAILERS/SALES CENTER WILL CONTAIN NEW | | | FOOTERS BASED ON NOTES AND REVIEWS BY BUILDING PLANS | | | EXAMINERS AND INSPECTION SERVICES MANAGER. PLEASE | | | PROVIDE REVISIONS TO THE GROUNDING ELECTRODE SYSTEM | | | BASED ON THE NEW FOOTER STEEL WHERE APPLICABLE PER | | | 250.50. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-01-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-13 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-13 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2007-01-13 15:18:19 | ** UNSAT ** | | | | | | 1) NOTE: PLANS FOR ELECTRICAL WILL BE REQUIRED TO BE | | | REVISED TO INCLUDE THE NEW FOOTER ATTACHEMENTS AS | | | REQUIRED PER 250.50. | | | PLEASE REVISE THE GROUNDING ELECTRODE RISER AT TRAILERS | | | AND/OR MAIN RISER. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEYPALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-17 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-17 |
Time |
11:34 |
Sent To |
PC |
|
| Notes |
| 2006-12-17 11:35:23 | REV FOR E 6.1, REVISED AS PREVIOUSLY REVIEWED, PLANS | | | SIGNED BY THE ENGINEER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-09 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-09 |
Time |
14:38 |
Sent To |
PC |
|
| Notes |
| 2006-12-09 14:43:50 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE SHEET E6.1 SHALL BE SIGNED AS ON | | | FILE AND RECOGNIZED BY THE CITY OF WEST PALM BEACH. | | | PLEASE SEE SIGNATURE ON E-5.1 WAS OK AS ON FILE. | | | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. IF THERE ARE ANY | | | QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-09 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-09 |
Time |
14:32 |
Sent To |
PC |
|
| Notes |
| 2006-12-09 14:39:31 | SHEET E 5.1, SEC'S TO FPL POLE PART OF OWNER OWNED | | | SERVICE. SHOWS 800A SEC'S TO A 400A MDP. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-03 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-03 |
Time |
18:54 |
Sent To |
|
|
| Notes |
| 2006-11-03 19:18:35 | **** NOTESREDLINED *** | | | | | | 1) WIND LOAD CALCULATIONS FOR LT POLES SUBMITTED AND | | | SHALL BE REVIEWED BY THE BUILDING REVIEWER. | | | | | | 2)STATE APPROVED PLANS, RED-LINED, NOT REVIEWED FOR | | | ELECTRICAL CODE COMPLIANCE BY THIS AHJ. ELECTRICAL | | | SERVICE PROVIDED IS NOT THE SAME AS THE VOLTAGE ON THE | | | TRAILERS. 120/240V | | | SERVICE SHEETS RED-LINED, TRAILER VOLTAGE 120/240 | | | WHERE-AS SERVICE IS 120/208V. | | | STATE APPROVED PLANS ARE EXEMPT FROM REVIEW. SERVICE | | | VOLTAGE NOTED, AND RESPONSE FROM TRAILER MANUFACTURE | | | MENTIONS VOLTAGECONSIDERATION WAS TAKEN INTO ACCOUNT | | | AND A/C UNITS/MOTORS LOADS ARE RATED FOR 208V. | | | ANY OF THIS EQUIPMENT IN STATE TRAILER UNITS AREAT | | | OWNERRISK ONLY. | | | | | | ELECTRICAL PLANS STAMPED, IF THERE ARE NAY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICALPLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-24 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-24 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2006-09-24 00:00:00 | ** UNSAT 2ND REVIEW ** | | | | | | PLEASE SEE NOTES FROM PREVIOUS REVIEW | | | THEY ARE SHOWN BELOW WHICH ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW. | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE:NO, PLEASE PROVIDE WORST CASE | | | ON RECORD SET OF PLANS. IT IS NOTED THAT | | | THIS WAS RESPONDED TO IN LTR. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 2004, | | | 13-413.1ABC.1 FOR MIN WORST CASE VOLTAGE | | | DROP SCENERIO TO BE PROVIDED. | | | | | | 3) NOTE: NO, PLEASE KNOW, THIS COMMENT | | | WAS DOE LIGHT POLES WHICH WAS IN COMMENT | | | ABOVE. IT IS KNOWN, THAT THIS IS A STATE | | | APPROVED TRAILER, AND THE COMMENT WAS | | | NOT INTENDED FOR THE WIND LOADS OF THE | | | TRAILERS FROM ELECTRICAL REVIEW. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE WIND LOAD | | | CALCULATIONS AT THIS TIME. PLANS | | | CURRENTLY MENTION THIS IS TO BE | | | PROVIDEDS, HOWEVER THIS IS REQUIRED AT | | | THIS TIME. | | | | | | 4) NOTE:NO,, NOT CLEAR, IS ALL THE | | | PROPOSED SITE LIGHTING WORK GOING TO BE | | | UNDER THIS PERMIT ALSO, OR IS THIS ONLY | | | FOR THE TEMP SALES CENTER? | | | | | | ** PREVIOUS REVIEW NOTE ** | | | ** THIS IS NOT A KAMM CONSULTING | | | COMMENT* | | | PLEASE SEE THAT THE VALUE SET FORTH ON | | | THE PERMIT APPLICATION AND SCOPE OF WORK | | | APPLIED FOR DOES NOT SEEMTO INCLUDE | | | ALL SITE, SITE LIGHTING, POLES FIXTURES | | | AND NEW SALES FACILITY. | | | IF ALL THE WORK AS SHOWN SUBMITTED ON | | | PLANS IS IN SCOPE (EXCLUDING FUTURE | | | BLDGS) THEN PLEASE ADJUST VALUE. | | | PLEASE KNOW, IF THE SITE POLE | | | CALCULATIONS ARE NOT SUBMITTED AT THIS | | | TIME, THEN THE SITE LIGHTING WILL BE | | | REQUIRED TO BE UNDER A SEPARATE PERMIT | | | WITH PLANS AND FEES ATTHAT TIME. | | | FBC ADMINISTRATIVE SECTION 108.3, AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 5) NOTE: OK. | | | | | | 6) NOTE: OK, EQUIPMENT TO BE VERIFIED | | | FOR VOLTAGES AS NOTED. | | | | | | 7) NOTE: ?? PLEASE SEE PREVIOUS NOTES ON | | | PLANS MENTIONED, NEUTRAL IS NOT TO BE | | | BONDED AT TRAILERS, THEREFORE GRND RODS | | | WOULD BE REQUIRED WHICH IS WHAT THE | | | PREVIOUS COMMENT WAS. PLEASE SEE NOW | | | PLANS STILL DO NOT SHOW ANY GROUNDING AT | | | THE TRAILERS, AND A NOTE HAS BEEN ADDED | | | TO "BOND" NEUTRAL TO THE EQUIPMENT | | | GROUNDIGN CONDUCTOR. PLEASE KNOW, IF | | | THIS IS DONE THIS WOULD PARALLEL THE | | | NEUTRAL WHICH CREATES OBJECTIONABLE | | | CURRENT (250.6). PLEASE PROVIDE THE GRND | | | RODS AND CWP(IF METAL) AND AS NOTED ANY | | | OTHER METAL PIPING AT THE TRAILERS. | | | PLEASE REMOVE NOTE #7 AS ANY METAL | | | CURRENT CARRYING PARTS FROM TO THE | | | TRAILERS MAY BE PRESENT. THIS CAN BE IN | | | SUCH OF TELEPHONE/CATV ETC). | | | 250.32, 250.6 | | | | | | **PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE GROUNDING AT | | | TRAILERS AND HOW THESE WILL BE GROUNDED. | | | IT SEEMS TO BE SHOWN ON RISER ,HOWEVER | | | NO | | | CONDUCTORS OR GRND RODS ARE SHOWN AT | | | TRAILERS?? | | | *IT WAS NOTED THAT THE NEUTRAL SHOULD | | | NTO BE BONDED AT THE TRAILER. | | | 250.50,550.16 | | | | | | 8) NOTE: OK, AS NOTED HOWEVER PLEASE SEE | | | NOTE BAOVE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INDICATE IF ANY (METAL ) | | | CWP TO BE BONDED. PLEASE SEE PLUMB RISER | | | WHICH SEEMS TO INDICATE THIS WHICH WILL | | | BE REQUIRED. | | | PLEASE ALSO KNOW, IF THE TRAILERS BECOME | | | REQUIRED TO CONTAIN FIRE SPRINKLERS, | | | THEN THIS LINE WOULD ALSO BE BONDED. | | | 250.50,250.104 | | | | | | 9) NOTE: OK, PLEASE BE SURE TO DO THE | | | SAME ON THE NEXT REVISED SHEETS. | | | THANK YOU. | | | | | | 10) NOTE:NO, SAME NOTE, YES, THESE ARE | | | STATE APPROVED TRAILERS, HOWEVER ALL | | | STATE APPROVED TRAILERS REVIEWED BY THIS | | | OFFICE CONTAING THE CIRCUITING WHICH | | | CORRELATES TO THE PANEL SCHEDLULES. | | | PLEASE SEE IF THESE PLANS ARE NOT | | | AVAILABLE AS MOST ARE. | | | PLEASE KNOW, IT IS MOST IMPORTANT, THAT | | | THE WIRING FOR THE EM/ EXT LTS IS DONE | | | PER 700.12E. IF THE NORMAL LIGHTING GOES | | | OUT THE EM/ EXT LTS ARE WIRED AHEAD OF | | | THE NORMAL LIGHTING IN ANY ONE AREA. THE | | | TRIPPING OF ANY SINGLE OCP DEVICE, SITCH | | | ETC SHOULD NOT LEAVE IN ONE AREA IN | | | TOTAL DARKNESS. | | | NFPA-101, 7.9.2.2 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THAT THE PLANS FOR | | | THE TRAILER SHALL INCLUDE ALL CIRCUITING | | | AND CORRELATE WITH PANEL SCHEDULES TO BE | | | SUBMITTED. | | | PLEASE SEE 700.12E FOR THE CIRCUITING | | | THE EM/EXT LTS ON A LOCAL LIGHTING | | | BRANCH CIRCUIT. | | | | | | 11) NOTE: OK. | | | | | | ** NEW NOTE ** | | | | | | 12) NOTE: PLEASE BE SURE THAT THE CODES | | | AND EDITIONS ARE REFLECTED ON E0.1. | | | NFPA-70 2002, NFPA-72 2002 , NFPA-101 | | | 2003. | | | | | | 13) NOTE: PLEASE SEE THE ADDRESS OF 2101 | | | OKEECHOBEE BLVD IS ASSIGNED TO THIS | | | PROJECT, PLEASE ADJUST AND PLACE ON ALL | | | TITLE BLOCKS AND PLANS. | | | FAC 61G1-16.004,61G15-23.002 | | | | | | ** IMPORTANT** | | | OLD SHEETS WERE LEFT IN SETS. | | | | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-30 |
Time |
21:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-30 |
Time |
19:05 |
Sent To |
|
|
| Notes |
| 2006-07-06 00:00:00 | **** UNSAT *** | | | | | | 1) NOTE: PLEASE PROVIDE ENERGY CALCS FOR | | | EXTERIOR LIGHTING. PLEASE SEE FBC 2004 | | | CHAPTER 13,13-415.1.ABC.2 AND PROVIDE | | | INFORMATION ACCORDINGLY. | | | | | | 2) NOTE: PLEASE SEE FBC 2004, | | | 13-413.1ABC.1 FOR MIN WORST CASE VOLTAGE | | | DROP SCENERIO TO BE PROVIDED. | | | | | | 3) NOTE: PLEASE PROVIDE WIND LOAD | | | CALCULATIONS AT THIS TIME. PLANS | | | CURRENTLY MENTION THIS IS TO BE | | | PROVIDEDS, HOWEVER THIS IS REQUIRED AT | | | THIS TIME. | | | | | | 4) NOTE: ** THIS IS NOT A KAMM | | | CONSULTING COMMENT* | | | PLEASE SEE THAT THE VALUE SET FORTH ON | | | THE PERMIT APPLICATION AND SCOPE OF WORK | | | APPLIED FOR DOES NOT SEEMTO INCLUDE | | | ALL SITE, SITE LIGHTING, POLES FIXTURES | | | AND NEW SALES FACILITY. | | | IF ALL THE WORK AS SHOWN SUBMITTED ON | | | PLANS IS IN SCOPE (EXCLUDING FUTURE | | | BLDGS) THEN PLEASE ADJUST VALUE. | | | PLEASE KNOW, IF THE SITE POLE | | | CALCULATIONS ARE NOT SUBMITTED AT THIS | | | TIME, THEN THE SITE LIGHTING WILL BE | | | REQUIRED TO BE UNDER A SEPARATE PERMIT | | | WITH PLANS AND FEES ATTHAT TIME. | | | FBC ADMINISTRATIVE SECTION 108.3, AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 5) NOTE: PLEASE SEE RISER AND MDP | | | SCHEDULE MENTIONS 3-PHASE FEEDS TO | | | TRAILER PANELS, YET PANELS IN TRAILERS | | | ARE SET UP AS 1-PHASE??? | | | PLEASE CORRELATE. | | | 215.5,106.1.2ADMIN SECTION. | | | | | | 6) NOTE: PLEASE ALSO SEE THE VOLTAGE | | | INDICATED FOR TRAILERS IS 120/240 AND | | | THE SERVICE BEING PROVIDED IS 120/208V. | | | PLEASE VERIFY IF ALL VOLTAGES FOR A/C'S | | | ETC WILL BE LISTED ETC TO RUN ON 208V. | | | ** PLEASE KNOW, THIS WAS JUST AN ISSUE | | | ON ANOTHER PROJECT AND THEINSTALLATION | | | OF STEP-DOWN TRANSFORMERS FOR ALL | | | EQUIPMENT HAD TO BE USED. | | | PLEASE VERIFY THIS AND CORRELATE. | | | 215.5,110.3, ETC | | | | | | 7) NOTE: PELASE PROVIDE GROUNDING AT | | | TRAILERS AND HOW THESE WILL BE GROUNDED. | | | IT SEEMS TO BE SHOWN ON RISER ,HOWEVR NO | | | CONDUCTORS OR GRND RODS ARE SHOWN AT | | | TRAILERS?? | | | *IT WAS NOTED THAT THE NEUTRAL SHOULD | | | NTO BE BONDED AT THE TRAILER. | | | 250.50,550.16 | | | | | | 8) NOTE: PLEASE INDICATE IF ANY (METAL ) | | | CWP TO BE BONDED. PLEASE SEE PLUMB RISER | | | WHICH SEEMS TO INDICATE THIS WHICH WILL | | | BE REQUIRED. | | | PLEASE ALSO KNOW, IF THE TRAILERS BECOME | | | REQUIRED TO CONTAIN FIRE SPRINKLERS, | | | THEN THIS LINE WOULD ALSO BE BONDED. | | | 250.50,250.104 | | | | | | 9) NOTE: PLEASE SEE THAT PLANS ARE | | | "SIGNED" WITH THE LEGAL SIGNATURE KNOWN | | | TO THIS OFFICE AND AS ON FILE BY THE | | | ENGINEER OF RECORD. | | | THE INITIALS AS SHOWN WILL NOT BE | | | ACCEPTED. | | | FS 471.025, FAC 61G15-23.002 | | | | | | 10) NOTE: PLEASE SEE THAT THE PLANS FOR | | | THE TRAILER SHALL INCLUDE ALL CIRCUITING | | | AND CORRELATE WITH PANEL SCHEDULES TO BE | | | SUBMITTED. | | | PLEASE SEE 700.12E FOR THE CIRCUITING | | | THE EM/EXT LTS ON A LOCAL LIGHTING | | | BRANCH CIRCUIT. | | | | | | 11) NOTE: PLEASE CLARIFY THE MEANS OF | | | DISCONNECT IN THE TRAILER PANELS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-10-05 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-10-05 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-10-05 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2006-10-05 00:00:00 | ALL COMMENTS MADE IN PREVIOUS REVIEW | | | WERE TAKEN CARE OF IN PERMIT # 06070442, | | | SO, PASS! |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-08-01 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-08-01 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | PULLUTION PREVENTION PLAN, DETAILS MUST | | | INCLUDE IN PLANS. | | | | | | ALSO NEED STORM | | | WATER,DRAINAGECALS.,PERVIOUS,IMPERVIOUS | | | CAL.,RUNOFF CAL.,GEOTECHNICAL ENG | | | REPORT, | | | | | | DRAWINGS MUST SAY ALL WORK MUST BE DONE | | | PER CITY OF WPB REQUIREMENTS LIKE | | | SIDEWALK,DRIVEWAY, APPROACHES, PARKINGS, | | | | | | MEET ADA, ETC. | | | | | | NEED UTILITY REVIEW FROM MANNY G.(45TH | | | STREET, ENG. SERVICES) | | | | | | RASIK CHOKSHI 805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
N |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-02-26 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-26 |
Time |
18:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-13 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-13 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2006-11-13 15:22:15 | *****APPROVED***** W/REMINDERS | | | | | | | | | | | | | | | 1.EXISTING FIRE HYDRANT NOT WITHIN 150 FEET OF THE | | | PROPOSED BUILDING. | | | | | | 2.NUMERICAL ADDRESS FOR THE PROPERTY SHOULD BE POSTED | | | BEFORE, DURING, AND AFTER CONSTRUCTION OPERATIONS. | | | | | | 3.SINCE THIS WILL BE AN UNSPRINKLERED BUILDING, ALL | | | INTERIOR FINISHES SHALL BE CLASS "A" OR CLASS "B". | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-10-16 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-10-16 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2006-10-16 16:18:36 | *****UNSAT***** | | | | | | | | | | | | | | | RESPONSES TO THE FIRE PLAN REVIEW COMMENTS OF | | | 07/11/2006: | | | | | | | | | | | | 1.)STILL COULD NOT LOCATE EXISTING FIRE HYDRANT ON | | | THE AMENDED SITE PLANS. | | | | | | 2.)SO NOTED. | | | | | | 3.)BUBBLE/CLOUD THE NUMERICAL ADDRESS. | | | | | | 4.)SO NOTED. | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-11 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-11 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2006-07-11 00:00:00 | 1. PLEASE ILLUSTRATE ALL EXISTING OR NEW | | | FIRE HYDRANTS IN THE VICINITY OF THIS | | | NEW BUILDING. A NOTE WAS LOCATED ON THE | | | SITE PLAN DRAWING INDICATING THAT THE | | | FINAL LOCATION OF FIRE HYDRANTS TO BE | | | DETERMINED AT TIME OF BUILDING PERMIT | | | APPLICATION. | | | | | | 2. PLEASE INDICATE IN WRITING HOW LONG | | | THE MODULAR BUILDING WILL BE ON SITE. IS | | | IT PERMANANT OR TEMPORARY. | | | | | | 3. BUILDING ADDRESS IS REQUIRED. A | | | MINIMUM OF AT LEAST 6" HIGH NUMBERS ARE | | | REQUIRED. | | | | | | 4. LOCKS ON EXIT DOORS SHALL NOT REQUIRE | | | THE USE OF A KEY, TOOL, OR SPECIAL | | | KNOWLEDGE FROM THE INTERIOR OF THE | | | BUILDING. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-24 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-24 |
Time |
15:18 |
Sent To |
B |
|
| Notes |
| 2007-03-24 15:19:22 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
13:34 |
Sent To |
B |
|
| Notes |
| 2007-03-08 13:35:32 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
13:31 |
Sent To |
B |
|
| Notes |
| 2007-03-08 13:31:28 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-12 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-12 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-02-12 13:43:27 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-31 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-31 |
Time |
09:24 |
Sent To |
E |
|
| Notes |
| 2007-01-31 09:24:40 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-01-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-25 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-25 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2007-01-25 09:50:34 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-01-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-24 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-24 |
Time |
11:51 |
Sent To |
E |
|
| Notes |
| 2007-01-24 11:52:19 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-18 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-18 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2007-01-30 10:04:43 | TO "COMM" BD#21 | | 2007-01-18 12:00:29 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-22 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-22 |
Time |
11:32 |
Sent To |
B |
|
| Notes |
| 2007-01-11 11:42:06 | TO "COMM" BD#24 | | 2006-12-22 11:33:14 | WAITING FOR "COMM" BD--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-16 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-16 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2006-12-16 17:52:55 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-12-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-16 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-16 |
Time |
17:50 |
Sent To |
B |
|
| Notes |
| 2006-12-16 17:50:45 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-07 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-07 |
Time |
11:57 |
Sent To |
E |
|
| Notes |
| 2006-12-07 11:57:59 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-30 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-30 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2006-11-01 16:43:50 | TO "COMM" BD#60 | | 2006-10-30 11:35:48 | WAITING FOR "COMM" BD--NEW SHEETS SUBMITTED FOR ALL | | | TRADES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-12 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
10:15 |
Sent To |
|
|
| Notes |
| 2006-09-20 00:00:00 | TO "COMM" BD#12 | | 2006-09-12 00:00:00 | WAITING FOR "COMM" BD-NEW "P" SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-11 |
Time |
06:36 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-15 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2006-06-24 00:00:00 | TO COMM BOARD SPACE #36, NEEDS ALL | | | TRADES, ZONING AND ENG. | | 2006-06-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-10-14 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-10-14 |
Time |
06:45 |
Sent To |
|
|
| Notes |
| 2006-10-14 07:05:43 | NO MECHANICAL PLANS SUBMITED. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-10 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-10 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-08-10 00:00:00 | NO MECHANICAL PLANS SUBMITTED OR | | | MECHANICAL CONTRACTOR INDICATED WITH THE | | | BUILDING PERMIT APPLICATION. | | | | | | PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. | | | | | | ENERGY CALCULATIONS SUBMITTED FOR THE | | | SHELL ONLY.PLEASE PROVIDE REVISED | | | ENERGY CALCULATIONS WITH THE BUILDOUT | | | PERMIT APPLICATION & PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-04 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-11-04 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-11-04 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2006-11-04 08:55:37 | RE STAMP PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-09-26 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-09-26 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2006-09-26 00:00:00 | RE-SUB, WATER & SEWER | | | SEPERATE PERMIT FOR IRRIGATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-08 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-08 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2006-07-08 00:00:00 | MANFACTURED BUILDING. | | | SEPERATE PERMIT FOR IRRIGATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-01-18 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-01-18 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-03 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-03 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2006-11-03 14:24:03 | APPROVED BY ERIC S, PPLANNER 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-09-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-09-26 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-17 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-17 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2006-07-17 00:00:00 | SEE NOTES FROM 7/12 REVIEW |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-12 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-12 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2006-07-12 00:00:00 | 1) PROVIDE SITE PLAN DATED 7-3-06 | | | (APPROVED ON 7-12-06). | | | | | | 2) PROVIDE LANDSCAPE PLAN DATED 6-9-06 | | | (APPROVED ON 7-12-06). | | | | | | 3) PROVIDE PHOTOMETRIC PLAN SIGNED AND | | | SEALED ON 7-7-06 (APPROVED ON 7-12-06). | | | | | | 4) PAVING AND GRADING SHEET C-4 TO SHOW | | | THE PARKING DETAILS MEETING WPB | | | STANDARDS (SEE APPROVED KILDAY SITE PLAN | | | SHEET 2 OF 2 FOR STANDARDS). | | | | | | CONTACT ERIC SCHNEIDER (561)822-1435. |
|
|