| Plan Review Stops For Permit 06060589 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-28 |
Time |
10:47 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-06-28 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-07 |
Time |
19:19 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-07 |
Time |
19:19 |
Sent To |
Z |
|
| Notes |
| 2006-08-07 00:00:00 | A) REVISED LOCATION/SETBACK OF GEN ONLY. | | | GEN IS LOCATED PLENTY DIST FROM HOUSE. | | | | | | B) THE ATS IS THE NEW RTS WHICH CONTAINS | | | MAINS FOR FPL AND FOR EMGEN FEEDERS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-07 |
Time |
15:21 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-07 |
Time |
15:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-07 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-07 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2006-07-07 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE A DISONNECTING MEANS | | | IS REQUIRED FOR THE FEEDERS COMING FROM | | | THE GENERATOR AT THE MAIN HOUSE GROUPED | | | WITH THE NEW MAIN OF THE SE RATED ATS. | | | PLEASE SEE THIS DISCONNECT DOES NOT | | | REQUIRE OCP AND IS ONLY A DISCONNECTING | | | MENAS. THIS MAY BE LOCATED ON THE LOAD | | | SIDE OF THE ATS OUTSIDE WITH ATS OR ON | | | THE LINE SIDE OF THE ATS FROM THE GEN. | | | 225.31-225.39, | | | | | | 2) NOTE: PLEASE INDICATE HOW THE GEN IS | | | BEING BOLTED DOWN AND ATTACHED TO SLAB. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-23 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-23 |
Time |
12:56 |
Sent To |
M |
|
| Notes |
| 2006-06-23 00:00:00 | ******* UNSAT *********** | | | | | | 1) NOTE: PLEASE SEE LOAD CALCULATIONS | | | ARE BEING REFERENCE TO 250.82 WHICH IS | | | NOT IN THE 2002 NEC WHICH IS WHAT WE ARE | | | UNDER. | | | 215.5 | | | | | | 2) NOTE: PLEASE SEE MISSING EUIPMENT | | | GROUNDING CONDUCTORS. | | | 250.24B,250.110,250.122 | | | | | | 3) NOTE: PLEASE SEE THE NEW ATS, SHALL | | | BE "SERVICE ENTRANCE RATED" AND CONTAIN | | | A MCB WHICH MEETS 230.2,230.70,230.76, | | | 230.79. PLEASE SEE OTHER NEW DISCONNECT | | | SHALL BE GROUPED AND LOCATED AT THE SAME | | | LOCATION AND MEETING 225.31-225.39 | | | | | | SPECS AS SUBMITTED AND MARKED AR NOT | | | ACCEPTABLE FOR INSTALLATION AS SHOWN. | | | | | | 4) NOTE: PLEASE SEE THAT MANUFACTURES | | | SPECS/CUT SHEETS SHALL INDICATE ALL MIN | | | CLEARENCES AROUND EQUIPMENT. | | | 110.26, 215.5 | | | FBC 106.2.1 | | | | | | 5) NOTE: PLEASE SEE THAT THIS PROPOSED | | | GEN IS LOCATED IN A FLOOD ZONE AND SHALL | | | BE INSTALLED A MIN OF 6" ABOVE BFE. | | | PLEASE KNOW, THIS IS REQUIRED TO BE | | | INDICATE ON PLANS AND PLEASE KNOW, | | | BEFORE A FINAL ELECTRICAL INSPECTION AN | | | ELEVATION CERTIFICATE SHALL BE GIVEN TO | | | THE INSPECTOR AND FILED ON RECORD. | | | | | | 6) NOTE: PLEASE SEE THAT ALL PLANS AND | | | DESIGN SHALL CONTAIN THE PRINTED NAME | | | AND SIGNATURE OF THE PERSON TAKING | | | RESPONSIBILITY OF PLANS AND DESIGN. | | | FBC 106.2.1, 106.3.2 | | | | | | | | | 7) NOTE: PLEASE SEE BUIDLIGN REVIEW | | | COMMENTS AS A SLAB DETAIL WAS NOT | | | SUBMITTED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
14:44 |
Sent To |
E |
|
| Notes |
| 2006-08-07 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
15:37 |
Sent To |
Z |
|
| Notes |
| 2006-07-31 00:00:00 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-03 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-03 |
Time |
16:22 |
Sent To |
E |
|
| Notes |
| 2006-07-03 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-23 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
08:52 |
Sent To |
E |
|
| Notes |
| 2006-06-20 00:00:00 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-28 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-12 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-26 |
Time |
14:38 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-06-26 |
Time |
14:38 |
Sent To |
B |
|
| Notes |
| 2006-06-26 00:00:00 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | PROVIDE MANUFACTURE'S INSTALLATION | | | INSTRUCTIONS AT THE JOBSITE FOR THE | | | FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-08-05 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-08-05 |
Time |
06:43 |
Sent To |
I |
|
| Notes |
| 2006-08-05 00:00:00 | THE PROPOSED GENERATOR SHALL NOT BE | | | CLOSER THAN 11FT FROM REAR PROPERTY | | | LINE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-18 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-18 |
Time |
18:36 |
Sent To |
I |
|
| Notes |
|
|