| Plan Review Stops For Permit 06060544 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-03 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-04-03 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2007-04-03 11:43:44 | BEAM REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-25 |
|
|
Cont ID |
|
| Sent By |
rnuquist |
Date |
2006-11-25 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rnuquist |
Date |
2006-11-25 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-10-10 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2006-10-10 |
Time |
10:51 |
Sent To |
PC |
|
| Notes |
| 2006-10-10 11:56:36 | | | | | | | DENIED | | | | | | PREVIOUS REVIEW COMMENTS NOT ADDRESSED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG PROVIDE | | | FOR WINDOWS,FRENCH DOORS, AND SIDING | | | | | | ******NO PRODUCT APPROVAL WAS SUBMITTED | | | FOR THE SIDING***** | | | | | | 5) THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | *******THE NEW DESIGNER OF RECORD | | | SHALL REVIEW AND APPROVE THE PRODUCTS | | | THAT WILL BE USED******* | | | | | | 6) PROVIDE 2 COPIES OF ENERGY CALC'S FOR | | | THE NEW ADDITION PER 13-101.2.2 FBC | | | | | | ******ENERGY CALC'S SHALL BE SIGNED AND | | | DATED BY THE OWNER/AGENT******* | | | | | | 7) OK | | | | | | 8) OK | | | | | | **********NEW REVIEW COMMENTS********* | | | | | | 1) EXISTING SLAB MUST MEET THE MINIMUM | | | FOUNDATION REQUIREMENTS, PLEASE | | | CONFIRM AND DETAIL | | | | | | 2) PROVIDE DETAIL ON WALL CONSTRUCTION, | | | MEMBER SIZE, O/C SPACING, ETC. | | | | | | 3) SOUTH ELEVATION DOES NOT MATCH | | | THE PLAN VIEW, PATIO ROOF ON THE PLAN | | | VIEW EXTENDS TO CORNER OF BUILDING | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-04 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2006-07-04 |
Time |
08:10 |
Rev Time |
1.50 |
| Received By |
amorse |
Date |
2006-07-04 |
Time |
08:10 |
Sent To |
PC |
|
| Notes |
| 2006-07-04 00:00:00 | | | | | | | DENIED | | | | | | 1) BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION | | | | | | 2) PROVIDE 2 COMPLETE SETS OF | | | CONSTRUCTION DOCUMENTS SHOW THE EXISTING | | | AND PROPOSED FLOOR PLANS IN EACH SET. | | | PROVIDE DETAILS ON THE FRAMING OF DOOR | | | AND WINDOW OPENINGS, SHOW ALL WOOD | | | CONNECTORS THAT WILL BE USED.PROVIDE A | | | SCHEDULE WITH ALL WOOD CONNECTORS THAT | | | WILL BE USED AND THEIR FL#S (FLORIDA | | | PRODUCT APPROVAL #'S) | | | | | | 3) CONSTRUCTION DOCUMENTS SHALL SHOW AT | | | A MINIMUM THE WIND DESIGN DATA PER | | | 1603.1 THROUGH 1603.1.4 | | | | | | 4) THE PERMIT APPLICATION SHALL INCLUDE | | | TWO COPIES OF EACH PRODUCT APPROVAL THAT | | | | | | IS RELEVANT PER 9B-72. THESE SHOULD | | | INCLUDE THE FLORIDA STATE APPROVAL COVER | | | PAGES, AND THE PRODUCT NOA THAT LISTS | | | THE SYSTEM COMPONENTS/ FASTENER LIST | | | PAGES, THE PAGES WITH THE CHOSEN | | | ASSEMBLY/ SYSTEM TO BE USED AND THE | | | GENERAL LIMITATIONS PAGE. ALL CAN BE | | | FOUND ON WWW.FLORIDABUILDING.ORG PROVIDE | | | FOR WINDOWS,FRENCH DOORS, AND SIDING | | | | | | 5) THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | | | | 6) PROVIDE 2 COPIES OF ENERGY CALC'S FOR | | | THE NEW ADDITION PER 13-101.2.2 FBC | | | | | | 7) CONSTRUCTION DOCUMENTS SHALL SHOW AT | | | A MINIMUM THE WIND DESIGN DATA PER | | | 1603.1 THROUGH 1603.1.4 | | | | | | 8) WILL REQUIRE DRAWINGS AND SEPERATE | | | PERMIT FOR AIR CONDITIONING AS WELL AS | | | PLUMBING AND ELECTRICAL PERMITS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-12 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-12 |
Time |
17:12 |
Sent To |
M |
|
| Notes |
| 2007-09-12 17:51:11 | | | | | | | ** DENIED REVIEW FOR REVISIONS** | | | | | | ** PLEASE SEE SOME ITEMS REDLINED ON PREVIOUS PLANS ARE | | | IN NEED OF CORRECTION. | | | PLEASE SEE ITEM MISSED ON PREVIOUS REVIEW WHICH IS IN | | | NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE PANEL SCHEDULE IS SHOWN AS A MLO | | | (MAIN LUG ONLY ) PANEL YET RISER SHOWS THIS AS MCB(MAIN | | | CIRCUIT BREAKER). | | | A MAIN IS REQUIRED PER 230.70, 230.71, PLEASE ADJUST. | | | | | | 2) NOTE: PLEASE SEE 424.3B AS THE OVER CURRENT | | | PROTECTION FOR THE 10KW AIR HANDLER IS REQUIRED TO BE | | | AT 125%. (60AMP MIN) | | | | | | 3) NOTE: PLEASE CLARIFY THE DINING ROOM CIRCUIT AS | | | SHOWN. IF THIS IS FOR LIGHTING THEN THIS IS OK, HOWEVER | | | OF THIS CIRCUIT IS FOR THE DINING ROOM RECEPTACLES, | | | THEN THIS MUST MEET 210.52B1, 210.11C1 AND 220.16. | | | MUST BE 20AMP, #12 AND 1500 VA FIGURED INTO THE LOAD | | | CALCULATIONS WITH SMALL APPLIANCE CIRCUITS. | | | | | | 4) NOTE: PREVIOUS PLANS CONTAINED THE SMOKE ALARMS AS | | | REQUIRED PER R313 OF THE FLORIDA RESIDENTIAL CODE AND | | | NFPA-72 11.5.1.1.1, 11.8.3 HOWEVER THEY HAVE NOW BEEN | | | REMOVED FROM PLANS. | | | PLEASE KNOW AS REQUIRED PER SECTIONS AS NOTED ABOVE, | | | PLEASE PLACE BACK ON PLANS MEETING THE MINIMUM CODE | | | REQUIREMENTS. | | | ** PLEASE ALSO KNOW THAT THESE WOULD BE SMOKE ALARMS, | | | NOT SMOKE DETECTORS AS LISTED ON PANEL SCHEDULE. PLEASE | | | SEE NFPA-72 DEFINITIONS AS SMOKE DETECTORS ONLY DETECT | | | AND DO NOT SOUND AN ALARM. | | | | | | 5) NOTE: PLEASE SEE KITCHEN COUNTER SPACE WHICH | | | INDICATES A NEW 60AMP SINGLE PHASE GFI. THIS IS UNCLEAR | | | WHAT THIS IS. | | | FBC 106.3.5.4, 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-23 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-23 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2007-04-23 17:13:05 | REDLINED NFPA-72 11.5.1.1, 11.8.3 FOR SMOKE | | | ALARMS/DEVICES. | | | REDLINED MCB | | | REDLINED 210.52B1 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-02-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-02-12 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-02-12 |
Time |
11:26 |
Sent To |
M |
|
| Notes |
| 2007-02-12 12:04:36 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE PLANS SUBMITTED CONTAIN *WHITE-OUT8 | | | AND HAND DRAWN CHANGES MADE TO PLANS. THIS IS NOT | | | PERMITTED IN ANY WAY. | | | FS 481.221. | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEWED PLANS WERE | | | REDLINED FOR MISSING NEW FOOTER STEEL REQUIRED AS PART | | | OF THE GROUNDING ELECTRODE SYSTEM.250.50 PLEASE INCLUDE | | | AS PREVIOUSLY REDLINED. | | | | | | 3) NOTE: PLEASE SEE MISSING SMOKE ALARMS PER NFPA-72 | | | 11.5.1.1, 11.8.3. | | | | | | 4) NOTE: PLEASE SEE THE OCP FOR THE 5KW HEAT STRIP | | | SHOWN TOO HIGH, 50A?S ON 5KW? VERIFY AND ADJUST ON | | | PANEL SCHEDULE. | | | THIS WAS REDLINED ON PREVIOUS PLANS TO REVISE. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-09 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-09 |
Time |
11:05 |
Sent To |
M |
|
| Notes |
| 2006-11-09 12:30:09 | *** REDLINEDTHE FOLLOWING: | | | | | | | | | NEW FOOTER STEEL REQUIRED AS PART OF THE GROUNDING | | | ELECTRODE SYSTEM.250.50, | | | | | | SA'S PER NFPA-72 11.5.1.1, 11.8.3 | | | | | | OCP FOR THE 5KW HEAT STRIP SHOWN TOO HIGH,50A'S ON | | | 5KW? VERIFY AND ADJUST IN FIELD. | | | REVISE WITH ANY OTHER REVISIONS BEFORE ROUGH. NO NEED | | | TO REVISE OR CORRECT AT THIS TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-09-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-26 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-24 |
Time |
17:24 |
Sent To |
M |
|
| Notes |
| 2006-09-26 00:00:00 | ********* UNSAT 2ND REVIEW ********* | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW ARE STILL IN NEED OF ADDRESSING | | | ALONG WIHT NEW NOTES DUE TO CHANGES IN | | | PLANS BEING SUBMITTED. | | | | | | 1) NOTE: OK, HOWEVER SEE NEW NOTES. | | | | | | 2) NOTE:OK, HOWEVER SEE NEW NOTES. | | | | | | 3) NOTE: NO, PLEASE SEE NO "SMOKE | | | DETECTORS" WERE SHOWN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE SD'S REQUIRED IN | | | EXSITING DWELLING, PER R313. IS DWELLING | | | CONTAINS EXISTING SD'S WHICH MEET | | | CURRENT CODE, PLEASE SHOW, OR PLEASE | | | SHOW NEW SD'S AS REQUIRED INSIDE AND OUT | | | SIDE ALL SLEEPING ROOMS. | | | NFPA-72 11.5.1.1,11.8.3 | | | | | | 4) NOTE: NO, PLEASE SEE THE SEC'S ARE | | | NOW BEING SHOWN, HOWEVER PLEASE SEE | | | THERE ARE NOW "TWO" "EQUIPMENT GROUNDING | | | CONDUCTORS" BEING SHOWN?? | | | PLEASE SEE 250.6, 250.24B AS THIS | | | CREATES OBJECTIONABLE CURRENTS. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE INDICATE THE NEW SEC'S | | | FROM METER TO NEW DISC. 215.5 | | | (NO EQUIP GROUNDING CONDUCTOR.) | | | | | | 5) NOTE: OK, NEW ARCHITECT. | | | | | | | | | 6) NOTE: NO,PLEASE SEE NO PANEL SCHEDULE | | | WAS SUBMITTED SHOWING ALL MIN | | | CIRCUITSING AS REQUIREDL. ARC FAULT FOR | | | NEW SD'S, AND ALL OTHER NEW CIRCUITS | | | BEING PROVIDED SHOWING THE OCP DEVICES | | | AND MIN CONDUCTORS SIZES. | | | 240.4,408.4,310.16 ETC. | | | PLEASE ALSO SEE NEW NOTES. | | | | | | ** PREVIOUS REVIEW NOTES | | | | | | PLEASE VERIFY LOAD OF NEW FRIG, | | | AS A NEW DEDICATED CIRCUITS IS NOT SHOWN | | | ON NEW PANEL SCHEDULE FOR THIS.?? | | | 210.23,24, 210.52B, 210.11C1, 220.16 | | | ETC. | | | | | | 7) NOTE: OK., HOWEVER DUE TO NNOTES NEW | | | AND EXISTING THESE LOADS MAY CHANGE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE LOADON | | | EXISTING 200A PANEL. | | | 215.5 | | | | | | ********** NEW NOTES ********* | | | | | | 8) NOTE: PLEASE SEE MISSING RECEPTS | | | ALONG KITCHEN COUNTER SPACE PER | | | 210.52C1, AND PLEASE BE SURE TO INDICATE | | | ALL GFI/GFI PROTECTED PER 210.8A6. | | | | | | 9) NOTE; PLEASE SEE A NEW 220V RECEPT IS | | | BEING SHOWN IN THE MIDDLE OF A ROOM | | | ALONG WITH A DISCONNECT AND GFI, BUT IT | | | IS UNCLEAR WHAT THESE ARE FOR?? | | | PLEASE SEE IS THIS THE MISSIGN DISC FOR | | | THE AHU?. PLEASE ALSO INDICATE WHAT THE | | | OTHER TWO ARE FOR? | | | ARE THESE MISPRINTS ON PLANS. | | | | | | 10) NOTE: PLEASE SHOW THE NEW CU UNIT | | | WHICH IS NOT SHOWN ON PLANS. | | | PLEASE SEE MISSING DISCONNECT PER 440.11 | | | , AND MISSING GFI (NEW OR EXISTING) PER | | | 210.63. | | | | | | 11) NOTE: PLEASE SEE THERE IS AN OVEN | | | NOW SHOWN IN LOAD CALCULATIONS, HOWEVER | | | NOT SHOWN IN KITCHEN LAYOUT. | | | PLEASE SHOW. | | | | | | 12) NOTE: PLEASE SEE "A" SHEET INDICATES | | | A NEW 60A SUB PANEL AND THERE IS A NOTE | | | FOR A NEW PANEL ON ELECTRICAL PLANS | | | HOWEVER THERE IS NO PANEL SCHEDULE | | | SUBMITTED TO INDICATE THE NEW FEED TO | | | THIS PANEL FOR OCP, FEEDERS, ETC . | | | PLEASE PROVIDE A REVISED RISER DIAGRAM | | | SHOWIGN THIS NEW SUB PANEL.215.5 | | | PLEASE SEE310.16,240.4, 408.4 ETC. | | | PLEASE ALSO SEE 100.26 FOR DIRECTION OF | | | THE FACING OF THE NEW SUB PANEL, AS | | | KITCHEN COUNTER SPACE IS ON ONE SIDE. | | | | | | 13) NOTE: PLEASE INDICATE THE LOCATIONS | | | OF ALL APPLIANCES, INCLUDING THE | | | LOCATIONS OF THE NEW DRYER, WASHER ETC. | | | SEEMS TO BE WHERE THE OLD KITCHEN WAS? | | | PLEASE INDICATE ALL AREA AND ROOM | | | DESIGNATIONS ON PLANS. | | | FBC 106.1.2 ADMIN SECT. | | | | | | 14) NOTE: PLEASE VERIFY NEW OR EXSTIGN | | | DEDICATED DINING RM/ BRKFAST RM CIRCUITS | | | PER 210.52B1,210.11C1, 220.16. | | | | | | | | | 15) NOTE: PLEASE CORRELATE MECHANICAL | | | AND ELECTRICAL FOR A/C HEAT LOADS. | | | PLEASE SEE ONE AT 8KW AND ONE BEING | | | SHOWN AT 5KW?? | | | 424.3B, 310.16,240.4 . | | | | | | | | | ** PLEASE KNOW, AS THERE ARE ITEMS NOT | | | SUBMITTED FOR REVIEW AS PERVIOUSLY | | | REQUESTED, AND REQUESTED ON THIS REVIEW, | | | PLEASE KNOW THERE MAY BE A POSSIBILITY | | | OF NEW COMMENTS ON NEXT REVIEW. | | | PLANS ARE NOT COMPLETE ATTHIS TIME. | | | 106.3.5.4 FBC ADMIN SECT. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2006-09-24 00:00:00 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-24 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-24 |
Time |
13:11 |
Sent To |
P |
|
| Notes |
| 2006-06-24 00:00:00 | ********* UNSAT ********* | | | | | | 1) NOTE: PLEASE SEE RISER INDICATES A | | | NEW DISCONNECT,HOWEVER PLEASE SEE THERE | | | IS NO INFORMATION WHERE THIS IS, WHAT | | | SIZE, AIC RATINGS ETC. | | | 110.9,215.5,230.72 | | | PLEASE SHOW EXSITING MCB LOCATION AND | | | LOCATION OF NEW DISC. | | | | | | 2) NOTE: PLEASE INDICATE SIZE OF METER, | | | AS SERVICE IS NOW BEING SHOWN AS 300A'S, | | | AND METER IF EXISTING 200A'S , IS NOT | | | ACCEPTABLE. PLEASE SEE SEC'S ARE NOT | | | SHOWN ON RISER. ARE THESE GOING TO BE | | | UPGRADES FOR NEW 300A SERVICE? OR ARE | | | THESE ALREADY RATED FOR 300A'S? | | | PLEASE SEE 240.4,310.16,310.15B6, ETC | | | | | | 3) NOTE: PLEASE PROVIDE SD'S REQUIRED IN | | | EXSITING DWELLING, PER R313. IS DWELLING | | | CONTAINS EXISTING SD'S WHICH MEET | | | CURRENT CODE, PLEASE SHOW, OR PLEASE | | | SHOW NEW SD'S AS REQUIRED INSIDE AND OUT | | | SIDE ALL SLEEPING ROOMS. | | | NFPA-72 11.5.1.1,11.8.3 | | | | | | 4) NOTE: PLEASE INDICATE THE NEW SEC'S | | | FROM METER TO NEW DISC. 215.5 | | | (NO EQUIP GROUNDING CONDUCTOR.) | | | | | | 5) NOTE: PLEASE SEE THAT THE PERSON | | | RESPONSIBLE FOR PLANS/ DESIGN SHALL | | | CLEARLY INDICATE THEIR PRINTED NAME AND | | | SIGNATURE. | | | FBC 106.1.2, 106.1.3,106.3.4.3 ADMIN | | | SECT AS ADOPTED BY THE CITY OF WEST PALM | | | BEACH. | | | | | | 6) NOTE: PLEASE VERIFY LOAD OF NEW FRIG, | | | AS A NEW DEDICATED CIRCUIT IS NOT SHOWN | | | ON NEW PANEL SCHEDULE FOR THIS.?? | | | 210.23,24, 210.52B, 210.11C1, 220.16 | | | ETC. | | | | | | 7) NOTE: PLEASE PROVIDE LOADON | | | EXISTIGN 200A PANEL. | | | 215.5 | | | | | | ** PLEASE BE SURE TO MAKE TWO COMPLETE | | | SETS FOR REVIEW AND STMAPING. PLEASE | | | KNOW THAT ALL OLD/VOIDED SHEETS SHOULD | | | BE COMPLETELY REMOVED FROM SETS AND ONLY | | | THE NEW REVISED SHEETS SHOULD B INSERTED | | | INTO THE NEW SETS. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | TO HELP TO AVOID ANY POSSIBLE DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-06-08 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2006-06-08 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2006-06-08 |
Time |
12:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-11 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-11 |
Time |
12:15 |
Sent To |
E |
|
| Notes |
| 2007-09-11 12:15:28 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-20 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-20 |
Time |
11:14 |
Sent To |
E |
|
| Notes |
| 2007-04-20 11:15:20 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-03-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-05 |
Time |
09:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-05 |
Time |
09:47 |
Sent To |
P |
|
| Notes |
| 2007-03-05 09:47:28 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-28 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-28 |
Time |
11:42 |
Sent To |
M |
|
| Notes |
| 2007-02-28 11:42:57 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-06 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-06 |
Time |
08:41 |
Sent To |
E |
|
| Notes |
| 2007-02-06 08:42:08 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-30 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-30 |
Time |
16:17 |
Sent To |
Z |
|
| Notes |
| 2006-11-30 16:17:56 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-07 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-07 |
Time |
11:08 |
Sent To |
E |
|
| Notes |
| 2006-11-07 11:09:15 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-25 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-25 |
Time |
10:36 |
Sent To |
Z |
|
| Notes |
| 2006-10-25 10:36:21 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-20 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-20 |
Time |
14:55 |
Sent To |
E |
|
| Notes |
| 2006-09-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-14 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-14 |
Time |
10:52 |
Sent To |
Z |
|
| Notes |
| 2006-09-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-23 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-23 |
Time |
10:11 |
Sent To |
E |
|
| Notes |
| 2006-06-23 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-07-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-12 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-13 |
Time |
08:12 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-09-13 |
Time |
08:12 |
Sent To |
P |
|
| Notes |
| 2007-09-13 08:15:30 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA | | | ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). | | | | | | *** DENIED *** | | | 1) PLEASE SHOW THE SIZE AND CFM'S OF THE SUPPLY AIR | | | GRILL IN THE DINING AREA (SEE YELLOW HIGH LIGHT ON | | | PLAN). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-01 |
Time |
09:56 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-01 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2007-03-01 10:02:19 | ** MECHANICAL REVISION ** | | | *** PROVISO *** | | | 1)A.H.U. MOUNTING DETAIL SHOWS AREA BETWEEN THE | | | SOFFITT AND CEILING TO BE OPEN WHICH WOULD MAKE THAT | | | PART OF THE OPEN PLENUM AND WOULD NEED TO COMPLY WITH | | | 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN PLENUMS, | | | ALSO COMPLY WITH2004 FBC/R M1601.10 MECHANICAL | | | CLOSETS. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-02-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-13 |
Time |
10:57 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-13 |
Time |
10:57 |
Sent To |
P |
|
| Notes |
| 2007-02-13 11:18:18 | MECHANICAL REVISION | | | *** DENIED *** | | | 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT. | | | | | | 2) SEE MECHANICAL REVISION PAGE M2-1, A.H.U. MOUNTING | | | DETAIL SHOWS AREA BETWEEN THE SOFFITT AND CEILING TO BE | | | OPEN WHICH WOULD MAKE THAT PART OF THE OPEN PLENUM AND | | | WOULD NEED TO COMPLY WITH2004 FBC/M 602.2.1 MATERIALS | | | EXPOSED WITHIN PLENUMS, ALSO SEE 2004 FBC/R M1601.10 | | | MECHANICAL CLOSETS. PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-11-09 |
Time |
13:53 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-11-09 |
Time |
13:53 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-27 |
Time |
09:58 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-27 |
Time |
09:58 |
Sent To |
P |
|
| Notes |
| 2006-09-27 00:00:00 | | | | *** DENIED *** | | | 1) PLEASE SHOW THE SIZES OF THE TWO | | | SUPPLY AIR MAIN TRUNK LINES. | | | | | | 2) PLEASE SHOW HOW AIR WILL RETURN TO | | | AIR HANDLER UNIT (IF GRILL ALSO SHOW | | | SIZE). | | | | | | 3) ENERGY CALCULATIONS NEED TO BE SIGNED | | | BY OWNER/AGENT ALSO, PER 2004 FBC | | | 13-600.3.ABC.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | 2006-09-25 00:00:00 | NEW HVAC PLANS/CALCS SUBMITTED FOR | | | REVIEW. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-28 |
Time |
09:18 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-06-28 |
Time |
09:18 |
Sent To |
B |
|
| Notes |
| 2006-06-28 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-26 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-26 |
Time |
13:30 |
Sent To |
PC |
|
| Notes |
| 2007-09-26 14:20:58 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | | ** FLORIDA STATUTES (FS). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE | | | RESUBMITTED REVISION: | | | | | | 1. SHEET M2-1 PLUMBING RISER DIAGRAM DOES NOT REFLECT | | | THE FLOOR PLAN PER FBC-2004 CHAPTER 1, SECTION 106.1.1 | | | INFORMATION ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. PLEASE CORRECT THE FOLLOWING ON THE | | | RESUBMITTAL. | | | | | | A} THE DOUBLE/BOWL KITCHEN SINK WITH DISHWASHER DOES | | | NOT REFLECT THE FLOOR PLAN. ONE BOWL IS BEING INDICATED | | | OUTSIDE OF THE BUILDING AND THE DISHWASHER DRAIN PER | | | FBC-2004 W/05 & 06 REV SECTION 802.2 SHALL DISCHARGE | | | INTO A WYE-BRANCH FITTING ON THE TAILPIECE OF THE | | | KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD | | | WASTE GRINDER. PLEASE CORRECT ON THE RESUBMITTED | | | REVISION. | | | | | | B} WASHER IN LAUNDRY ROOM DOES NOT REFLECT THE FLOOR | | | PLAN. WASHER IS BEING INDICATED OUTSIDE OF THE | | | BUILDING. PLEASE CORRECT ON THE RESUBMITTED REVISION. | | | | | | 2. SHEET M2-1 PLUMBING RISER DIAGRAM THE AIR | | | ADMITTANCE VALVES (STUDOR VENTS) ARE INDICATED WRONG | | | PER FBC-2004 W/05 & 06 REV. PLUMBING SECTION 917.4 THE | | | AIR ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF 4 | | | INCHES ABOVE THE HORIZONTAL BRANCH DRAIN OR FIXTURE | | | DRAIN BEING VENTED. PLEASE CORRECT ON THE RESUBMITTED | | | REVISION. | | | | | | 3. SHEET M2-1 PLUMBING RISER DIAGRAM: PRE FBC-2004 | | | W/05 & 06 REV. PLUMBING SECTION708.3.5 BUILDING DRAIN | | | AND BUILDING | | | SEWER JUNCTION. THERE SHALL BE A | | | TWO-WAY CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. | | | | | | | | | ********IMPORTANT INFORMATION********** | | | PLEASE REFERENCE THE RED LINE SANITARY PLUMBING RISER | | | DIAGRAM ON SHEET M2-1 THAT REFLECTS THE FLOOR PLAN AND | | | IS CODE COMPLIANT FOR THE REVISION RESUBMITTAL. THERE | | | IS ONLY ONE CORRECTED DRAWING IN RED INK ON THE | | | INDICATED PLAN SHEET BY THIS PLAN EXAMINER FOR | | | REFERENCE FOR THE RESUBMITTAL. REVISION WILL NOT PASS | | | PLUMBING PLAN REVIEW UNTIL ALL REQUESTED PLUMBING | | | CORRECTIONS ARE MET. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-13 |
Time |
14:58 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-03-13 |
Time |
14:58 |
Sent To |
PC |
|
| Notes |
| 2007-03-13 15:19:48 | REVISION: OK, SEE PROVISO | | | | | | ****************PROVISO**************** | | | A} PER FBC-2004 PLUMBING, SECTION 917.4 LOCATION: THE | | | AIR ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF 4 | | | INCHES ABOVE THE HORIZONTAL BRANCH DRAIN OR FIXTURE | | | DRAIN BEING VENTED. | | | B} PER FBC-2004 PLUMBING, SECTION 802.1.6 DOMESTIC | | | DISHWASHING MACHINES: DOMESTIC DISHWASHING MACHINES | | | SHALL DISCHARGE INTO A WYE-BRANCH FITTING ON THE | | | TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER | | | CONNECTION OF A FOOD WASTE GRINDER. | | | C} PER FBC-2004 PLUMBING, SECTION 708.3.5 BUILDING | | | DRAIN AND BUILDING | | | SEWER JUNCTION: THERE SHALL BE A | | | CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-14 |
Time |
15:46 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-02-14 |
Time |
15:46 |
Sent To |
B |
|
| Notes |
| 2007-02-14 16:26:10 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY | | | OF WEST PALM BEACH AMENDMENTS: | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE ON THE REVISION: | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION | | | ON CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | ******* PLEASE REVISE THE FOLLOWING ON SHEET M2-1 | | | PLUMBING RISER DIAGRAM: | | | A} CLEARLY INDENTIFY THE AIR ADMITTANCE VALVES FOR THE | | | SINKS ON SHEET M2-1 PLUMBING RISER DIAGRAM ON THE | | | RESUBMITTED REVISION PER FBC-2004 PLUMBING, SECTION | | | 917. | | | B} PLEASE REVISE THE AIR ADMITTANCE VALVES LOCATION | | | FOR THE SINKS ON SHEET M2-1 PLUMBING RISER DIAGRAM PER | | | FBC-2004 PLUMBING, SECTION 917.4. | | | C} CLEARLY INDICATE THE DOUBLE BOWL SINK W/ DISPOAL | | | AND DISHWASHER PLUMBING ON SHEET M2-1 PLUMBING RISER | | | DIAGRAM ON THE RESUBMITTED REVISION. | | | | | | ******IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-12-08 |
Time |
10:43 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-12-08 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
| 2006-12-08 10:51:51 | NOTE: SENT TO L. MARTINEZ PER HIS REQUEST. | | | | | | ***************PROVISO*************** | | | PER FBC-2004 PLUMBING, SECTION 917.4 LOCATION: THE AIR | | | ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF FOUR | | | INCHES (4") ABOVE THE HORIZONTAL BRANCH DRAIN OR | | | FIXTURE DRAIN BEING VENTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-11-14 |
Time |
13:48 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-11-14 |
Time |
13:48 |
Sent To |
B |
|
| Notes |
| 2006-11-14 14:35:38 | UNSAT 3RD TIME | | | REFERENCE: FBC-2004 PLUMBING | | | | | | THE FOLLOWING CORRECTIONS ARE STILL REQUIRED FOR | | | PLUMBING PLAN REVIEW,PLEASE REFERENCE THE CORRECTED | | | SANITARY PLUMBING RISER DIAGRAM ON SHEET M2-1 FOR THE | | | RESUBMITTAL: | | | | | | 1. THE TWO WAY CLEANOUT IS STILL INDICATED WRONG ON THE | | | SANITARY PLUMBING RISER DIAGRAM ON SHEET M2-1. PLEASE | | | CORRECT ON THE RESUBMITTAL. | | | | | | 2. THE DOUBLE BOWL KITCHEN SINK WITH A DISHWASHER ON | | | SHEET M2-1 IS STILL INDICATED WRONG ON THE SANITARY | | | RISER DIAGRAM. PLEASE CORRECT ON THE RESUBMITTAL. | | | | | | 3. THE STUDOR VENT INDICATED ON SHEET M2-1 IS STILL | | | INDICATED WRONG. PER FBC-2004 PLUMBING, SECTION 917.4 | | | THE STUDOR VENT SHALL BE LOCATED A MINIMUM OF 4" ABOVE | | | THE HORIZONTAL DRAIN BRANCH. PLEASE CORRECT ON THE | | | RESUBMITTAL. | | | | | | THE FOLLOWING ARE NEW ITEMS FOUND ON THE RESUBMITTAL | | | THAT NEED TO BE CORRECTED ON THE RESUBMITTAL TO MEET | | | CODE COMPLIANCE: | | | | | | 4. PLEASE INDICATE THE STANDPIPE ON THE WASHING | | | MACHINE. PER FBC-2004 PLUMBING, SECTION 802.4 | | | | | | 5. PLEASE CORRECT THE LOCATION OF THE CLEANOUT ON THE | | | WASHING MACHINE STACK TO BE FOUR FEET ABOVE FINNISH | | | FLOOR (4' AFF). PER FBC-2004 PLUMBING, SECTION 708.9 | | | ACCESS SHALL BE PROVIDED TO ALL CLEANOUTS. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-10-06 |
Time |
14:08 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2006-10-06 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
| 2006-10-06 00:00:00 | ******UNSAT****** | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING INFORMATION IS REQUIRED | | | FOR PLUMBING PLAN REVIEW: | | | | | | 1. THE TWO-WAY CLEANOUT ON SHEET M2-1 IS | | | INDICATED WRONG ON THE SANITARY PLUMBING | | | RISER DIAGRAM. PLEASE CORRECT FOR THE | | | RESUBMITTAL. | | | | | | 2. THE DOUBLE BOWL KITCHEN SINK WITH | | | DISHWASHER ON SHEET M2-1 IS INDICATED | | | WRONG ON THE SANITARY PLUMBING RISER | | | DIAGRAM. PLEASE CORRECT FOR THE | | | RESUBMITTAL. | | | | | | 3. THE STUDOR VENT INDICATED ON THE | | | ISLAND SINK ON SHEET M2-1 IS INDICATED | | | WRONG. PER FBC-2004 PLUMBING, SECTION | | | 917.4 THE STUDOR VENT SHALL BE A MINIMUM | | | OF 4" ABOVE THE HORIZONTAL BRANCH DRAIN. | | | | | | 4. PER FBC-2004 PLUMBING, SECTION | | | 106.3.5.4 PLEASE INDICATE THE EXISTING | | | KITCHEN RENOVATED INTO A LAUNDRY ROOM | | | PLUMBING ON THE SANITARY PLUMBING | | | ISOMETRIC RISER DIAGRAM. PLEASE REMEMBER | | | THE FOLLOWING WHEN ADDING THE WASHING | | | MACHINE PLUMBING TO THE SANITARY | | | ISOMETRIC PLUMBING RISER DIAGRAM. | | | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | (B) 802.4 STANDPIPES.STANDPIPES SHALL BE | | | INDIVIDUALLY TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING. | | | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: PLEASE REFERENCE THE | | | CORRECTIONS IN RED INK ON SHEET M2-1 ON | | | THE ISOMETRIC SANITARY RISER DIAGRAM, | | | ONLY ONE CORRECTED DRAWING IN RED INK | | | FOR REFERENCE FOR RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-28 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-28 |
Time |
07:16 |
Sent To |
M |
|
| Notes |
| 2006-06-28 00:00:00 | DENIED; | | | 1.PERSON RESPONSIBLE FOR DESIGN OF PLANS | | | SHALL CLEARLY PRINT AND SIGN. FBC-2004 | | | CHAPTER 1 SEC. 106.1.2 AND 106.1.3.4.3. | | | 2.PLUMBING CANNOT BE INSTALLED PER RISER | | | DIAGRAM; PLEASE SHOW MACHANICAL VENTS IN | | | PLACE OF VENTS THRU THE ROOF. (ONE SET | | | OF PLANS MARKED IN RED) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-12-08 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-12-08 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-12-08 |
Time |
12:23 |
Sent To |
I |
|
| Notes |
| 2006-12-08 12:24:00 | PROVISO: PLEASE MERGE A2-1 SHEETS WITH NEW SHEETS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-03 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-11-03 |
Time |
17:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-11-03 |
Time |
17:01 |
Sent To |
I |
|
| Notes |
| 2006-11-03 17:23:28 | DENIED, | | | 1. THE SURVEY AND MAIN LEVEL PLAN A1-1 & A2-1 DOES NOT | | | MATCH. | | | 2. SURVEY DOES NOT SHOW THE CARPORT AND SHOWS THE REAR | | | STRUCTURE AS A 1 STORY GARAGE. | | | 3. A1-1 & A2-1 SHOWS A PLAY ROOM, PLEASE PROVIDE PLANS | | | THAT SHOWS THE INTERIOR OF THE STRUCTURE AND PROVIDE | | | PROOF OF PERMIT CONVERTING THE GARAGE INTO A PLAY | | | ROOM. | | | 4. PLEASE CLEARLY INDENTIFY THE DEMOLISHING PLANS AND | | | PROPOSE WORK. | | | 5. THE SURVEY MUST SHOW THE TWO A/C UNITS. | | | 6. THE SURVEY DOES NOT SHOW THE CARPORT AND SETBACKS | | | FROM THE SIDE AND FRONT PROPERTY LINE. | | | 7. IF THE CARPORT IS NOT APART OF THE PROPOSED WORK, | | | PLEASE REMOVE IT FROM PLANS A1-1 & A2-1. | | | 8. THE CARPORT DOES NOT SHOW IF THERE WILL BE ANY | | | INTERIOR ACCESS TOTHE MAINHOUSE LAUNDRY ROOM. 9. | | | SMALL SURVEYS DOES NOT PROVIDE THE REAR SETBACK OF THE | | | PROPOSED KITCHEN (ENCLOSED PORCH) | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-09-19 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-09-19 |
Time |
18:00 |
Sent To |
I |
|
| Notes |
| 2006-09-19 00:00:00 | DENIED, | | | 1. THE TWO COPIES OF SURVEYS DOES NOT | | | SHOW THE PROPOSED WORK (ENCLOSED | | | EXISTING PORCH) WITH SETBACKS FROM | | | FRONT/SIDE/REAR PROPERTY LINE (AREA OF | | | WORK IS NOT KNOWN) | | | 2. THE PROPOSED WORK MUST MEET THE | | | SETBACKS FOR THE ZONE SF14 (SEC 94-74) | | | 3. NEED TO PROVIDE TWO SETS OF PLANS | | | SHOWING THE DEMOLITION AREA AND THE | | | PROPOSED CLEARLY IDENTIFYING THE ROOMS | | | AND THEIR INTERIOR ACCESS. | | | 4. THE MAIN LEVEL PLAN DOES NOT CLEARLY | | | SHOW WHAT IS BEING DEMO AND PROPPOSED. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-22 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-22 |
Time |
16:31 |
Sent To |
I |
|
| Notes |
| 2006-06-22 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO COPY OF SURVEY | | | SHOWING THE PROPOSED ADDITION (MARKED) | | | WITH SIDE & REAR SETBACK (FROM PROPERTY | | | LINE) | | | NOTE: ONLY 1 COPY OF SURVEY WAS | | | SUBMITTED & WORK WAS NOT MARKED WITH | | | SETBACKS | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|