Plan Review Details - Permit 06060544
Plan Review Stops For Permit 06060544
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-04-03 Cont ID  
Sent By lmartine Date 2007-04-03 Time 11:43 Rev Time 0.00
Received By lmartine Date 2007-04-03 Time 11:43 Sent To  
Notes
2007-04-03 11:43:44BEAM REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-11-25 Cont ID  
Sent By rnuquist Date 2006-11-25 Time 10:07 Rev Time 0.00
Received By rnuquist Date 2006-11-25 Time 10:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-10 Cont ID  
Sent By amorse Date 2006-10-10 Time 10:51 Rev Time 0.00
Received By amorse Date 2006-10-10 Time 10:51 Sent To PC
Notes
2006-10-10 11:56:36 
  
 DENIED
  
 PREVIOUS REVIEW COMMENTS NOT ADDRESSED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION
  
 2) OK
  
 3) OK
  
 4) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG PROVIDE
 FOR WINDOWS,FRENCH DOORS, AND SIDING
  
 ******NO PRODUCT APPROVAL WAS SUBMITTED
 FOR THE SIDING*****
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 *******THE NEW DESIGNER OF RECORD
 SHALL REVIEW AND APPROVE THE PRODUCTS
 THAT WILL BE USED*******
  
 6) PROVIDE 2 COPIES OF ENERGY CALC'S FOR
 THE NEW ADDITION PER 13-101.2.2 FBC
  
 ******ENERGY CALC'S SHALL BE SIGNED AND
 DATED BY THE OWNER/AGENT*******
  
 7) OK
  
 8) OK
  
 **********NEW REVIEW COMMENTS*********
  
 1) EXISTING SLAB MUST MEET THE MINIMUM
 FOUNDATION REQUIREMENTS, PLEASE
 CONFIRM AND DETAIL
  
 2) PROVIDE DETAIL ON WALL CONSTRUCTION,
 MEMBER SIZE, O/C SPACING, ETC.
  
 3) SOUTH ELEVATION DOES NOT MATCH
 THE PLAN VIEW, PATIO ROOF ON THE PLAN
 VIEW EXTENDS TO CORNER OF BUILDING
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-04 Cont ID  
Sent By amorse Date 2006-07-04 Time 08:10 Rev Time 1.50
Received By amorse Date 2006-07-04 Time 08:10 Sent To PC
Notes
2006-07-04 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION
  
 2) PROVIDE 2 COMPLETE SETS OF
 CONSTRUCTION DOCUMENTS SHOW THE EXISTING
 AND PROPOSED FLOOR PLANS IN EACH SET.
 PROVIDE DETAILS ON THE FRAMING OF DOOR
 AND WINDOW OPENINGS, SHOW ALL WOOD
 CONNECTORS THAT WILL BE USED.PROVIDE A
 SCHEDULE WITH ALL WOOD CONNECTORS THAT
 WILL BE USED AND THEIR FL#S (FLORIDA
 PRODUCT APPROVAL #'S)
  
 3) CONSTRUCTION DOCUMENTS SHALL SHOW AT
 A MINIMUM THE WIND DESIGN DATA PER
 1603.1 THROUGH 1603.1.4
  
 4) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
  
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG PROVIDE
 FOR WINDOWS,FRENCH DOORS, AND SIDING
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
  
 6) PROVIDE 2 COPIES OF ENERGY CALC'S FOR
 THE NEW ADDITION PER 13-101.2.2 FBC
  
 7) CONSTRUCTION DOCUMENTS SHALL SHOW AT
 A MINIMUM THE WIND DESIGN DATA PER
 1603.1 THROUGH 1603.1.4
  
 8) WILL REQUIRE DRAWINGS AND SEPERATE
 PERMIT FOR AIR CONDITIONING AS WELL AS
 PLUMBING AND ELECTRICAL PERMITS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status F Date 2007-09-12 Cont ID  
Sent By dpalmer Date 2007-09-12 Time 17:50 Rev Time 0.00
Received By dpalmer Date 2007-09-12 Time 17:12 Sent To M
Notes
2007-09-12 17:51:11 
  
 ** DENIED REVIEW FOR REVISIONS**
  
 ** PLEASE SEE SOME ITEMS REDLINED ON PREVIOUS PLANS ARE
 IN NEED OF CORRECTION.
 PLEASE SEE ITEM MISSED ON PREVIOUS REVIEW WHICH IS IN
 NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE PANEL SCHEDULE IS SHOWN AS A MLO
 (MAIN LUG ONLY ) PANEL YET RISER SHOWS THIS AS MCB(MAIN
 CIRCUIT BREAKER).
 A MAIN IS REQUIRED PER 230.70, 230.71, PLEASE ADJUST.
  
 2) NOTE: PLEASE SEE 424.3B AS THE OVER CURRENT
 PROTECTION FOR THE 10KW AIR HANDLER IS REQUIRED TO BE
 AT 125%. (60AMP MIN)
  
 3) NOTE: PLEASE CLARIFY THE DINING ROOM CIRCUIT AS
 SHOWN. IF THIS IS FOR LIGHTING THEN THIS IS OK, HOWEVER
 OF THIS CIRCUIT IS FOR THE DINING ROOM RECEPTACLES,
 THEN THIS MUST MEET 210.52B1, 210.11C1 AND 220.16.
 MUST BE 20AMP, #12 AND 1500 VA FIGURED INTO THE LOAD
 CALCULATIONS WITH SMALL APPLIANCE CIRCUITS.
  
 4) NOTE: PREVIOUS PLANS CONTAINED THE SMOKE ALARMS AS
 REQUIRED PER R313 OF THE FLORIDA RESIDENTIAL CODE AND
 NFPA-72 11.5.1.1.1, 11.8.3 HOWEVER THEY HAVE NOW BEEN
 REMOVED FROM PLANS.
 PLEASE KNOW AS REQUIRED PER SECTIONS AS NOTED ABOVE,
 PLEASE PLACE BACK ON PLANS MEETING THE MINIMUM CODE
 REQUIREMENTS.
 ** PLEASE ALSO KNOW THAT THESE WOULD BE SMOKE ALARMS,
 NOT SMOKE DETECTORS AS LISTED ON PANEL SCHEDULE. PLEASE
 SEE NFPA-72 DEFINITIONS AS SMOKE DETECTORS ONLY DETECT
 AND DO NOT SOUND AN ALARM.
  
 5) NOTE: PLEASE SEE KITCHEN COUNTER SPACE WHICH
 INDICATES A NEW 60AMP SINGLE PHASE GFI. THIS IS UNCLEAR
 WHAT THIS IS.
 FBC 106.3.5.4, 106.1.2 FOR ADDITIONAL INFORMATION.
  
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-04-23 Cont ID  
Sent By dpalmer Date 2007-04-23 Time 17:12 Rev Time 0.00
Received By dpalmer Date 2007-04-23 Time 16:04 Sent To PC
Notes
2007-04-23 17:13:05REDLINED NFPA-72 11.5.1.1, 11.8.3 FOR SMOKE
 ALARMS/DEVICES.
 REDLINED MCB
 REDLINED 210.52B1

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-02-12 Cont ID  
Sent By dpalmer Date 2007-02-12 Time 12:02 Rev Time 0.00
Received By dpalmer Date 2007-02-12 Time 11:26 Sent To M
Notes
2007-02-12 12:04:36*** UNSAT ***
  
 1) NOTE: PLEASE SEE PLANS SUBMITTED CONTAIN *WHITE-OUT8
 AND HAND DRAWN CHANGES MADE TO PLANS. THIS IS NOT
 PERMITTED IN ANY WAY.
 FS 481.221.
  
 2) NOTE: PLEASE SEE PREVIOUS REVIEWED PLANS WERE
 REDLINED FOR MISSING NEW FOOTER STEEL REQUIRED AS PART
 OF THE GROUNDING ELECTRODE SYSTEM.250.50 PLEASE INCLUDE
 AS PREVIOUSLY REDLINED.
  
 3) NOTE: PLEASE SEE MISSING SMOKE ALARMS PER NFPA-72
 11.5.1.1, 11.8.3.
  
 4) NOTE: PLEASE SEE THE OCP FOR THE 5KW HEAT STRIP
 SHOWN TOO HIGH, 50A?S ON 5KW? VERIFY AND ADJUST ON
 PANEL SCHEDULE.
 THIS WAS REDLINED ON PREVIOUS PLANS TO REVISE.
  
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-11-09 Cont ID  
Sent By dpalmer Date 2006-11-09 Time 12:30 Rev Time 0.00
Received By dpalmer Date 2006-11-09 Time 11:05 Sent To M
Notes
2006-11-09 12:30:09*** REDLINEDTHE FOLLOWING:
  
  
 NEW FOOTER STEEL REQUIRED AS PART OF THE GROUNDING
 ELECTRODE SYSTEM.250.50,
  
 SA'S PER NFPA-72 11.5.1.1, 11.8.3
  
 OCP FOR THE 5KW HEAT STRIP SHOWN TOO HIGH,50A'S ON
 5KW? VERIFY AND ADJUST IN FIELD.
 REVISE WITH ANY OTHER REVISIONS BEFORE ROUGH. NO NEED
 TO REVISE OR CORRECT AT THIS TIME.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-26 Cont ID  
Sent By dpalmer Date 2006-09-26 Time 07:28 Rev Time 0.00
Received By dpalmer Date 2006-09-24 Time 17:24 Sent To M
Notes
2006-09-26 00:00:00********* UNSAT 2ND REVIEW *********
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW ARE STILL IN NEED OF ADDRESSING
 ALONG WIHT NEW NOTES DUE TO CHANGES IN
 PLANS BEING SUBMITTED.
  
 1) NOTE: OK, HOWEVER SEE NEW NOTES.
  
 2) NOTE:OK, HOWEVER SEE NEW NOTES.
  
 3) NOTE: NO, PLEASE SEE NO "SMOKE
 DETECTORS" WERE SHOWN.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE PROVIDE SD'S REQUIRED IN
 EXSITING DWELLING, PER R313. IS DWELLING
 CONTAINS EXISTING SD'S WHICH MEET
 CURRENT CODE, PLEASE SHOW, OR PLEASE
 SHOW NEW SD'S AS REQUIRED INSIDE AND OUT
 SIDE ALL SLEEPING ROOMS.
 NFPA-72 11.5.1.1,11.8.3
  
 4) NOTE: NO, PLEASE SEE THE SEC'S ARE
 NOW BEING SHOWN, HOWEVER PLEASE SEE
 THERE ARE NOW "TWO" "EQUIPMENT GROUNDING
 CONDUCTORS" BEING SHOWN??
 PLEASE SEE 250.6, 250.24B AS THIS
 CREATES OBJECTIONABLE CURRENTS.
  
 ** PREVIOUS REVIEW NOTE**
 PLEASE INDICATE THE NEW SEC'S
 FROM METER TO NEW DISC. 215.5
 (NO EQUIP GROUNDING CONDUCTOR.)
  
 5) NOTE: OK, NEW ARCHITECT.
  
  
 6) NOTE: NO,PLEASE SEE NO PANEL SCHEDULE
 WAS SUBMITTED SHOWING ALL MIN
 CIRCUITSING AS REQUIREDL. ARC FAULT FOR
 NEW SD'S, AND ALL OTHER NEW CIRCUITS
 BEING PROVIDED SHOWING THE OCP DEVICES
 AND MIN CONDUCTORS SIZES.
 240.4,408.4,310.16 ETC.
 PLEASE ALSO SEE NEW NOTES.
  
 ** PREVIOUS REVIEW NOTES
  
 PLEASE VERIFY LOAD OF NEW FRIG,
 AS A NEW DEDICATED CIRCUITS IS NOT SHOWN
 ON NEW PANEL SCHEDULE FOR THIS.??
 210.23,24, 210.52B, 210.11C1, 220.16
 ETC.
  
 7) NOTE: OK., HOWEVER DUE TO NNOTES NEW
 AND EXISTING THESE LOADS MAY CHANGE.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE PROVIDE LOADON
 EXISTING 200A PANEL.
 215.5
  
 ********** NEW NOTES *********
  
 8) NOTE: PLEASE SEE MISSING RECEPTS
 ALONG KITCHEN COUNTER SPACE PER
 210.52C1, AND PLEASE BE SURE TO INDICATE
 ALL GFI/GFI PROTECTED PER 210.8A6.
  
 9) NOTE; PLEASE SEE A NEW 220V RECEPT IS
 BEING SHOWN IN THE MIDDLE OF A ROOM
 ALONG WITH A DISCONNECT AND GFI, BUT IT
 IS UNCLEAR WHAT THESE ARE FOR??
 PLEASE SEE IS THIS THE MISSIGN DISC FOR
 THE AHU?. PLEASE ALSO INDICATE WHAT THE
 OTHER TWO ARE FOR?
 ARE THESE MISPRINTS ON PLANS.
  
 10) NOTE: PLEASE SHOW THE NEW CU UNIT
 WHICH IS NOT SHOWN ON PLANS.
 PLEASE SEE MISSING DISCONNECT PER 440.11
 , AND MISSING GFI (NEW OR EXISTING) PER
 210.63.
  
 11) NOTE: PLEASE SEE THERE IS AN OVEN
 NOW SHOWN IN LOAD CALCULATIONS, HOWEVER
 NOT SHOWN IN KITCHEN LAYOUT.
 PLEASE SHOW.
  
 12) NOTE: PLEASE SEE "A" SHEET INDICATES
 A NEW 60A SUB PANEL AND THERE IS A NOTE
 FOR A NEW PANEL ON ELECTRICAL PLANS
 HOWEVER THERE IS NO PANEL SCHEDULE
 SUBMITTED TO INDICATE THE NEW FEED TO
 THIS PANEL FOR OCP, FEEDERS, ETC .
 PLEASE PROVIDE A REVISED RISER DIAGRAM
 SHOWIGN THIS NEW SUB PANEL.215.5
 PLEASE SEE310.16,240.4, 408.4 ETC.
 PLEASE ALSO SEE 100.26 FOR DIRECTION OF
 THE FACING OF THE NEW SUB PANEL, AS
 KITCHEN COUNTER SPACE IS ON ONE SIDE.
  
 13) NOTE: PLEASE INDICATE THE LOCATIONS
 OF ALL APPLIANCES, INCLUDING THE
 LOCATIONS OF THE NEW DRYER, WASHER ETC.
 SEEMS TO BE WHERE THE OLD KITCHEN WAS?
 PLEASE INDICATE ALL AREA AND ROOM
 DESIGNATIONS ON PLANS.
 FBC 106.1.2 ADMIN SECT.
  
 14) NOTE: PLEASE VERIFY NEW OR EXSTIGN
 DEDICATED DINING RM/ BRKFAST RM CIRCUITS
 PER 210.52B1,210.11C1, 220.16.
  
  
 15) NOTE: PLEASE CORRELATE MECHANICAL
 AND ELECTRICAL FOR A/C HEAT LOADS.
 PLEASE SEE ONE AT 8KW AND ONE BEING
 SHOWN AT 5KW??
 424.3B, 310.16,240.4 .
  
  
 ** PLEASE KNOW, AS THERE ARE ITEMS NOT
 SUBMITTED FOR REVIEW AS PERVIOUSLY
 REQUESTED, AND REQUESTED ON THIS REVIEW,
 PLEASE KNOW THERE MAY BE A POSSIBILITY
 OF NEW COMMENTS ON NEXT REVIEW.
 PLANS ARE NOT COMPLETE ATTHIS TIME.
 106.3.5.4 FBC ADMIN SECT.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
2006-09-24 00:00:00IN ELEC FOR REVIEW

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-24 Cont ID  
Sent By dpalmer Date 2006-06-24 Time 13:31 Rev Time 0.00
Received By dpalmer Date 2006-06-24 Time 13:11 Sent To P
Notes
2006-06-24 00:00:00********* UNSAT *********
  
 1) NOTE: PLEASE SEE RISER INDICATES A
 NEW DISCONNECT,HOWEVER PLEASE SEE THERE
 IS NO INFORMATION WHERE THIS IS, WHAT
 SIZE, AIC RATINGS ETC.
 110.9,215.5,230.72
 PLEASE SHOW EXSITING MCB LOCATION AND
 LOCATION OF NEW DISC.
  
 2) NOTE: PLEASE INDICATE SIZE OF METER,
 AS SERVICE IS NOW BEING SHOWN AS 300A'S,
 AND METER IF EXISTING 200A'S , IS NOT
 ACCEPTABLE. PLEASE SEE SEC'S ARE NOT
 SHOWN ON RISER. ARE THESE GOING TO BE
 UPGRADES FOR NEW 300A SERVICE? OR ARE
 THESE ALREADY RATED FOR 300A'S?
 PLEASE SEE 240.4,310.16,310.15B6, ETC
  
 3) NOTE: PLEASE PROVIDE SD'S REQUIRED IN
 EXSITING DWELLING, PER R313. IS DWELLING
 CONTAINS EXISTING SD'S WHICH MEET
 CURRENT CODE, PLEASE SHOW, OR PLEASE
 SHOW NEW SD'S AS REQUIRED INSIDE AND OUT
 SIDE ALL SLEEPING ROOMS.
 NFPA-72 11.5.1.1,11.8.3
  
 4) NOTE: PLEASE INDICATE THE NEW SEC'S
 FROM METER TO NEW DISC. 215.5
 (NO EQUIP GROUNDING CONDUCTOR.)
  
 5) NOTE: PLEASE SEE THAT THE PERSON
 RESPONSIBLE FOR PLANS/ DESIGN SHALL
 CLEARLY INDICATE THEIR PRINTED NAME AND
 SIGNATURE.
 FBC 106.1.2, 106.1.3,106.3.4.3 ADMIN
 SECT AS ADOPTED BY THE CITY OF WEST PALM
 BEACH.
  
 6) NOTE: PLEASE VERIFY LOAD OF NEW FRIG,
 AS A NEW DEDICATED CIRCUIT IS NOT SHOWN
 ON NEW PANEL SCHEDULE FOR THIS.??
 210.23,24, 210.52B, 210.11C1, 220.16
 ETC.
  
 7) NOTE: PLEASE PROVIDE LOADON
 EXISTIGN 200A PANEL.
 215.5
  
 ** PLEASE BE SURE TO MAKE TWO COMPLETE
 SETS FOR REVIEW AND STMAPING. PLEASE
 KNOW THAT ALL OLD/VOIDED SHEETS SHOULD
 BE COMPLETELY REMOVED FROM SETS AND ONLY
 THE NEW REVISED SHEETS SHOULD B INSERTED
 INTO THE NEW SETS.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 TO HELP TO AVOID ANY POSSIBLE DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-06-08 Cont ID  
Sent By swurafti Date 2006-06-08 Time 12:18 Rev Time 0.00
Received By swurafti Date 2006-06-08 Time 12:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-09-11 Cont ID  
Sent By adarroug Date 2007-09-11 Time 12:15 Rev Time 0.00
Received By adarroug Date 2007-09-11 Time 12:15 Sent To E
Notes
2007-09-11 12:15:28TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-04-20 Cont ID  
Sent By adarroug Date 2007-04-20 Time 11:14 Rev Time 0.00
Received By adarroug Date 2007-04-20 Time 11:14 Sent To E
Notes
2007-04-20 11:15:20TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-03-05 Cont ID  
Sent By adarroug Date 2007-03-05 Time 09:47 Rev Time 0.00
Received By adarroug Date 2007-03-05 Time 09:47 Sent To P
Notes
2007-03-05 09:47:28TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-02-28 Cont ID  
Sent By adarroug Date 2007-02-28 Time 11:42 Rev Time 0.00
Received By adarroug Date 2007-02-28 Time 11:42 Sent To M
Notes
2007-02-28 11:42:57TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-02-06 Cont ID  
Sent By adarroug Date 2007-02-06 Time 08:41 Rev Time 0.00
Received By adarroug Date 2007-02-06 Time 08:41 Sent To E
Notes
2007-02-06 08:42:08TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-11-30 Cont ID  
Sent By adarroug Date 2006-11-30 Time 16:17 Rev Time 0.00
Received By adarroug Date 2006-11-30 Time 16:17 Sent To Z
Notes
2006-11-30 16:17:56TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-11-07 Cont ID  
Sent By adarroug Date 2006-11-07 Time 11:08 Rev Time 0.00
Received By adarroug Date 2006-11-07 Time 11:08 Sent To E
Notes
2006-11-07 11:09:15TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-10-25 Cont ID  
Sent By adarroug Date 2006-10-25 Time 10:36 Rev Time 0.00
Received By adarroug Date 2006-10-25 Time 10:36 Sent To Z
Notes
2006-10-25 10:36:21TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-20 Cont ID  
Sent By adarroug Date 2006-09-20 Time 14:55 Rev Time 0.00
Received By adarroug Date 2006-09-20 Time 14:55 Sent To E
Notes
2006-09-20 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-14 Cont ID  
Sent By adarroug Date 2006-09-14 Time 10:52 Rev Time 0.00
Received By adarroug Date 2006-09-14 Time 10:52 Sent To Z
Notes
2006-09-14 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-23 Cont ID  
Sent By adarroug Date 2006-06-23 Time 10:11 Rev Time 0.00
Received By adarroug Date 2006-06-23 Time 10:11 Sent To E
Notes
2006-06-23 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-07-04 Time   Rev Time 0.00
Received By adarroug Date 2006-06-12 Time 13:41 Sent To  
Notes
2006-06-12 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 6 Status F Date 2007-09-13 Cont ID  
Sent By tgordon Date 2007-09-13 Time 08:12 Rev Time 0.20
Received By tgordon Date 2007-09-13 Time 08:12 Sent To P
Notes
2007-09-13 08:15:30PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) PLEASE SHOW THE SIZE AND CFM'S OF THE SUPPLY AIR
 GRILL IN THE DINING AREA (SEE YELLOW HIGH LIGHT ON
 PLAN).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-03-01 Cont ID  
Sent By tgordon Date 2007-03-01 Time 09:56 Rev Time 0.30
Received By tgordon Date 2007-03-01 Time 09:56 Sent To  
Notes
2007-03-01 10:02:19** MECHANICAL REVISION **
 *** PROVISO ***
 1)A.H.U. MOUNTING DETAIL SHOWS AREA BETWEEN THE
 SOFFITT AND CEILING TO BE OPEN WHICH WOULD MAKE THAT
 PART OF THE OPEN PLENUM AND WOULD NEED TO COMPLY WITH
 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN PLENUMS,
 ALSO COMPLY WITH2004 FBC/R M1601.10 MECHANICAL
 CLOSETS.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2007-02-13 Cont ID  
Sent By tgordon Date 2007-02-13 Time 10:57 Rev Time 0.30
Received By tgordon Date 2007-02-13 Time 10:57 Sent To P
Notes
2007-02-13 11:18:18MECHANICAL REVISION
 *** DENIED ***
 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT.
  
 2) SEE MECHANICAL REVISION PAGE M2-1, A.H.U. MOUNTING
 DETAIL SHOWS AREA BETWEEN THE SOFFITT AND CEILING TO BE
 OPEN WHICH WOULD MAKE THAT PART OF THE OPEN PLENUM AND
 WOULD NEED TO COMPLY WITH2004 FBC/M 602.2.1 MATERIALS
 EXPOSED WITHIN PLENUMS, ALSO SEE 2004 FBC/R M1601.10
 MECHANICAL CLOSETS. PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-11-09 Cont ID  
Sent By tgordon Date 2006-11-09 Time 13:53 Rev Time 0.30
Received By tgordon Date 2006-11-09 Time 13:53 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-09-27 Cont ID  
Sent By tgordon Date 2006-09-27 Time 09:58 Rev Time 0.30
Received By tgordon Date 2006-09-27 Time 09:58 Sent To P
Notes
2006-09-27 00:00:00 
 *** DENIED ***
 1) PLEASE SHOW THE SIZES OF THE TWO
 SUPPLY AIR MAIN TRUNK LINES.
  
 2) PLEASE SHOW HOW AIR WILL RETURN TO
 AIR HANDLER UNIT (IF GRILL ALSO SHOW
 SIZE).
  
 3) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
2006-09-25 00:00:00NEW HVAC PLANS/CALCS SUBMITTED FOR
 REVIEW.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-06-28 Cont ID  
Sent By tgordon Date 2006-06-28 Time 09:18 Rev Time 0.15
Received By tgordon Date 2006-06-28 Time 09:18 Sent To B
Notes
2006-06-28 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 7 Status F Date 2007-09-26 Cont ID  
Sent By mperson Date 2007-09-26 Time 13:30 Rev Time 0.00
Received By mperson Date 2007-09-26 Time 13:30 Sent To PC
Notes
2007-09-26 14:20:58REVISION DENIED
 REFERENCE:
 ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE (FAC).
 ** FLORIDA STATUTES (FS).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE
 RESUBMITTED REVISION:
  
 1. SHEET M2-1 PLUMBING RISER DIAGRAM DOES NOT REFLECT
 THE FLOOR PLAN PER FBC-2004 CHAPTER 1, SECTION 106.1.1
 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL. PLEASE CORRECT THE FOLLOWING ON THE
 RESUBMITTAL.
  
 A} THE DOUBLE/BOWL KITCHEN SINK WITH DISHWASHER DOES
 NOT REFLECT THE FLOOR PLAN. ONE BOWL IS BEING INDICATED
 OUTSIDE OF THE BUILDING AND THE DISHWASHER DRAIN PER
 FBC-2004 W/05 & 06 REV SECTION 802.2 SHALL DISCHARGE
 INTO A WYE-BRANCH FITTING ON THE TAILPIECE OF THE
 KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD
 WASTE GRINDER. PLEASE CORRECT ON THE RESUBMITTED
 REVISION.
  
 B} WASHER IN LAUNDRY ROOM DOES NOT REFLECT THE FLOOR
 PLAN. WASHER IS BEING INDICATED OUTSIDE OF THE
 BUILDING. PLEASE CORRECT ON THE RESUBMITTED REVISION.
  
 2. SHEET M2-1 PLUMBING RISER DIAGRAM THE AIR
 ADMITTANCE VALVES (STUDOR VENTS) ARE INDICATED WRONG
 PER FBC-2004 W/05 & 06 REV. PLUMBING SECTION 917.4 THE
 AIR ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF 4
 INCHES ABOVE THE HORIZONTAL BRANCH DRAIN OR FIXTURE
 DRAIN BEING VENTED. PLEASE CORRECT ON THE RESUBMITTED
 REVISION.
  
 3. SHEET M2-1 PLUMBING RISER DIAGRAM: PRE FBC-2004
 W/05 & 06 REV. PLUMBING SECTION708.3.5 BUILDING DRAIN
 AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A
 TWO-WAY CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
  
  
 ********IMPORTANT INFORMATION**********
 PLEASE REFERENCE THE RED LINE SANITARY PLUMBING RISER
 DIAGRAM ON SHEET M2-1 THAT REFLECTS THE FLOOR PLAN AND
 IS CODE COMPLIANT FOR THE REVISION RESUBMITTAL. THERE
 IS ONLY ONE CORRECTED DRAWING IN RED INK ON THE
 INDICATED PLAN SHEET BY THIS PLAN EXAMINER FOR
 REFERENCE FOR THE RESUBMITTAL. REVISION WILL NOT PASS
 PLUMBING PLAN REVIEW UNTIL ALL REQUESTED PLUMBING
 CORRECTIONS ARE MET.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]
  

Review Stop P PLUMBING
Rev No 6 Status P Date 2007-03-13 Cont ID  
Sent By mperson Date 2007-03-13 Time 14:58 Rev Time 0.45
Received By mperson Date 2007-03-13 Time 14:58 Sent To PC
Notes
2007-03-13 15:19:48REVISION: OK, SEE PROVISO
  
 ****************PROVISO****************
 A} PER FBC-2004 PLUMBING, SECTION 917.4 LOCATION: THE
 AIR ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF 4
 INCHES ABOVE THE HORIZONTAL BRANCH DRAIN OR FIXTURE
 DRAIN BEING VENTED.
 B} PER FBC-2004 PLUMBING, SECTION 802.1.6 DOMESTIC
 DISHWASHING MACHINES: DOMESTIC DISHWASHING MACHINES
 SHALL DISCHARGE INTO A WYE-BRANCH FITTING ON THE
 TAILPIECE OF THE KITCHEN SINK OR THE DISHWASHER
 CONNECTION OF A FOOD WASTE GRINDER.
 C} PER FBC-2004 PLUMBING, SECTION 708.3.5 BUILDING
 DRAIN AND BUILDING
 SEWER JUNCTION: THERE SHALL BE A
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.

Review Stop P PLUMBING
Rev No 5 Status F Date 2007-02-14 Cont ID  
Sent By mperson Date 2007-02-14 Time 15:46 Rev Time 0.45
Received By mperson Date 2007-02-14 Time 15:46 Sent To B
Notes
2007-02-14 16:26:10REVISION DENIED
 REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY
 OF WEST PALM BEACH AMENDMENTS:
  
 THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING
 PLAN REVIEW TO MEET CODE COMPLIANCE ON THE REVISION:
  
 1. PER FBC-2004 CHAPTER 1, SECTION 106.1.1 INFORMATION
 ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
 ******* PLEASE REVISE THE FOLLOWING ON SHEET M2-1
 PLUMBING RISER DIAGRAM:
 A} CLEARLY INDENTIFY THE AIR ADMITTANCE VALVES FOR THE
 SINKS ON SHEET M2-1 PLUMBING RISER DIAGRAM ON THE
 RESUBMITTED REVISION PER FBC-2004 PLUMBING, SECTION
 917.
 B} PLEASE REVISE THE AIR ADMITTANCE VALVES LOCATION
 FOR THE SINKS ON SHEET M2-1 PLUMBING RISER DIAGRAM PER
 FBC-2004 PLUMBING, SECTION 917.4.
 C} CLEARLY INDICATE THE DOUBLE BOWL SINK W/ DISPOAL
 AND DISHWASHER PLUMBING ON SHEET M2-1 PLUMBING RISER
 DIAGRAM ON THE RESUBMITTED REVISION.
  
 ******IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-12-08 Cont ID  
Sent By mperson Date 2006-12-08 Time 10:43 Rev Time 0.33
Received By mperson Date 2006-12-08 Time 10:42 Sent To B
Notes
2006-12-08 10:51:51NOTE: SENT TO L. MARTINEZ PER HIS REQUEST.
  
 ***************PROVISO***************
 PER FBC-2004 PLUMBING, SECTION 917.4 LOCATION: THE AIR
 ADMITTANCE VALVE SHALL BE LOCATED A MINIMUM OF FOUR
 INCHES (4") ABOVE THE HORIZONTAL BRANCH DRAIN OR
 FIXTURE DRAIN BEING VENTED.

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-11-14 Cont ID  
Sent By mperson Date 2006-11-14 Time 13:48 Rev Time 0.33
Received By mperson Date 2006-11-14 Time 13:48 Sent To B
Notes
2006-11-14 14:35:38UNSAT 3RD TIME
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING CORRECTIONS ARE STILL REQUIRED FOR
 PLUMBING PLAN REVIEW,PLEASE REFERENCE THE CORRECTED
 SANITARY PLUMBING RISER DIAGRAM ON SHEET M2-1 FOR THE
 RESUBMITTAL:
  
 1. THE TWO WAY CLEANOUT IS STILL INDICATED WRONG ON THE
 SANITARY PLUMBING RISER DIAGRAM ON SHEET M2-1. PLEASE
 CORRECT ON THE RESUBMITTAL.
  
 2. THE DOUBLE BOWL KITCHEN SINK WITH A DISHWASHER ON
 SHEET M2-1 IS STILL INDICATED WRONG ON THE SANITARY
 RISER DIAGRAM. PLEASE CORRECT ON THE RESUBMITTAL.
  
 3. THE STUDOR VENT INDICATED ON SHEET M2-1 IS STILL
 INDICATED WRONG. PER FBC-2004 PLUMBING, SECTION 917.4
 THE STUDOR VENT SHALL BE LOCATED A MINIMUM OF 4" ABOVE
 THE HORIZONTAL DRAIN BRANCH. PLEASE CORRECT ON THE
 RESUBMITTAL.
  
 THE FOLLOWING ARE NEW ITEMS FOUND ON THE RESUBMITTAL
 THAT NEED TO BE CORRECTED ON THE RESUBMITTAL TO MEET
 CODE COMPLIANCE:
  
 4. PLEASE INDICATE THE STANDPIPE ON THE WASHING
 MACHINE. PER FBC-2004 PLUMBING, SECTION 802.4
  
 5. PLEASE CORRECT THE LOCATION OF THE CLEANOUT ON THE
 WASHING MACHINE STACK TO BE FOUR FEET ABOVE FINNISH
 FLOOR (4' AFF). PER FBC-2004 PLUMBING, SECTION 708.9
 ACCESS SHALL BE PROVIDED TO ALL CLEANOUTS.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-10-06 Cont ID  
Sent By mperson Date 2006-10-06 Time 14:08 Rev Time 0.45
Received By mperson Date 2006-10-06 Time 14:08 Sent To B
Notes
2006-10-06 00:00:00******UNSAT******
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW:
  
 1. THE TWO-WAY CLEANOUT ON SHEET M2-1 IS
 INDICATED WRONG ON THE SANITARY PLUMBING
 RISER DIAGRAM. PLEASE CORRECT FOR THE
 RESUBMITTAL.
  
 2. THE DOUBLE BOWL KITCHEN SINK WITH
 DISHWASHER ON SHEET M2-1 IS INDICATED
 WRONG ON THE SANITARY PLUMBING RISER
 DIAGRAM. PLEASE CORRECT FOR THE
 RESUBMITTAL.
  
 3. THE STUDOR VENT INDICATED ON THE
 ISLAND SINK ON SHEET M2-1 IS INDICATED
 WRONG. PER FBC-2004 PLUMBING, SECTION
 917.4 THE STUDOR VENT SHALL BE A MINIMUM
 OF 4" ABOVE THE HORIZONTAL BRANCH DRAIN.
  
 4. PER FBC-2004 PLUMBING, SECTION
 106.3.5.4 PLEASE INDICATE THE EXISTING
 KITCHEN RENOVATED INTO A LAUNDRY ROOM
 PLUMBING ON THE SANITARY PLUMBING
 ISOMETRIC RISER DIAGRAM. PLEASE REMEMBER
 THE FOLLOWING WHEN ADDING THE WASHING
 MACHINE PLUMBING TO THE SANITARY
 ISOMETRIC PLUMBING RISER DIAGRAM.
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE
 INDIVIDUALLY TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: PLEASE REFERENCE THE
 CORRECTIONS IN RED INK ON SHEET M2-1 ON
 THE ISOMETRIC SANITARY RISER DIAGRAM,
 ONLY ONE CORRECTED DRAWING IN RED INK
 FOR REFERENCE FOR RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-28 Cont ID  
Sent By jleech Date 2006-06-28 Time 07:16 Rev Time 0.00
Received By jleech Date 2006-06-28 Time 07:16 Sent To M
Notes
2006-06-28 00:00:00DENIED;
 1.PERSON RESPONSIBLE FOR DESIGN OF PLANS
 SHALL CLEARLY PRINT AND SIGN. FBC-2004
 CHAPTER 1 SEC. 106.1.2 AND 106.1.3.4.3.
 2.PLUMBING CANNOT BE INSTALLED PER RISER
 DIAGRAM; PLEASE SHOW MACHANICAL VENTS IN
 PLACE OF VENTS THRU THE ROOF. (ONE SET
 OF PLANS MARKED IN RED)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 4 Status P Date 2006-12-08 Cont ID  
Sent By mmclean Date 2006-12-08 Time 12:23 Rev Time 0.00
Received By mmclean Date 2006-12-08 Time 12:23 Sent To I
Notes
2006-12-08 12:24:00PROVISO: PLEASE MERGE A2-1 SHEETS WITH NEW SHEETS.

Review Stop Z ZONING
Rev No 3 Status F Date 2006-11-03 Cont ID  
Sent By mmclean Date 2006-11-03 Time 17:01 Rev Time 0.00
Received By mmclean Date 2006-11-03 Time 17:01 Sent To I
Notes
2006-11-03 17:23:28DENIED,
 1. THE SURVEY AND MAIN LEVEL PLAN A1-1 & A2-1 DOES NOT
 MATCH.
 2. SURVEY DOES NOT SHOW THE CARPORT AND SHOWS THE REAR
 STRUCTURE AS A 1 STORY GARAGE.
 3. A1-1 & A2-1 SHOWS A PLAY ROOM, PLEASE PROVIDE PLANS
 THAT SHOWS THE INTERIOR OF THE STRUCTURE AND PROVIDE
 PROOF OF PERMIT CONVERTING THE GARAGE INTO A PLAY
 ROOM.
 4. PLEASE CLEARLY INDENTIFY THE DEMOLISHING PLANS AND
 PROPOSE WORK.
 5. THE SURVEY MUST SHOW THE TWO A/C UNITS.
 6. THE SURVEY DOES NOT SHOW THE CARPORT AND SETBACKS
 FROM THE SIDE AND FRONT PROPERTY LINE.
 7. IF THE CARPORT IS NOT APART OF THE PROPOSED WORK,
 PLEASE REMOVE IT FROM PLANS A1-1 & A2-1.
 8. THE CARPORT DOES NOT SHOW IF THERE WILL BE ANY
 INTERIOR ACCESS TOTHE MAINHOUSE LAUNDRY ROOM. 9.
 SMALL SURVEYS DOES NOT PROVIDE THE REAR SETBACK OF THE
 PROPOSED KITCHEN (ENCLOSED PORCH)
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2006-09-19 Cont ID  
Sent By mmclean Date 2006-09-19 Time 18:00 Rev Time 0.00
Received By mmclean Date 2006-09-19 Time 18:00 Sent To I
Notes
2006-09-19 00:00:00DENIED,
 1. THE TWO COPIES OF SURVEYS DOES NOT
 SHOW THE PROPOSED WORK (ENCLOSED
 EXISTING PORCH) WITH SETBACKS FROM
 FRONT/SIDE/REAR PROPERTY LINE (AREA OF
 WORK IS NOT KNOWN)
 2. THE PROPOSED WORK MUST MEET THE
 SETBACKS FOR THE ZONE SF14 (SEC 94-74)
 3. NEED TO PROVIDE TWO SETS OF PLANS
 SHOWING THE DEMOLITION AREA AND THE
 PROPOSED CLEARLY IDENTIFYING THE ROOMS
 AND THEIR INTERIOR ACCESS.
 4. THE MAIN LEVEL PLAN DOES NOT CLEARLY
 SHOW WHAT IS BEING DEMO AND PROPPOSED.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-06-22 Cont ID  
Sent By mmclean Date 2006-06-22 Time 16:31 Rev Time 0.00
Received By mmclean Date 2006-06-22 Time 16:31 Sent To I
Notes
2006-06-22 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE PROPOSED ADDITION (MARKED)
 WITH SIDE & REAR SETBACK (FROM PROPERTY
 LINE)
 NOTE: ONLY 1 COPY OF SURVEY WAS
 SUBMITTED & WORK WAS NOT MARKED WITH
 SETBACKS
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720