| Plan Review Stops For Permit 06060540 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-10 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-10 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | REVIEWED AND STAMPED NEW PAGES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-20 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-06-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-27 |
Time |
20:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-27 |
Time |
20:29 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-05 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-05 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | *** UNSAT *** | | | | | | 1) NOTE: PER CONVERSATION WITH | | | CONTRACTOR SCOPE OF WORK FOR ELECTRICAL | | | STTOD AT ONE WALL AND TWO OR SO LT | | | FIXTURES IN THE REAR OF UNIT SPACE. | | | PLEASE SEE PLANS INDICATE THE ENTIRE | | | REAR AREA AND WHAT APPEARS TO BE | | | "SQUARES" FOR NOTES, HOWWER NOTES COULD | | | NOT BE LOCATED. | | | PLEASE SEE GENERAL NOTE MENTIONS TO | | | REPAIR AND REPLACE ITEMS AS REQUIRED. | | | PLEASE ALSO SEE BUILDING SHEETS INDICATE | | | RECONSTRUCTION OF SOFFITS ETC WHICH | | | WOULD REQUIRE ELECTRICAL WORK IT SEEMS | | | OF SOME SORT. | | | | | | ** PLEASE INDICATE SCOPE OF WORK. CONT | | | ALSO MENTIONED NO ELECTRICAL PANELS, ETC | | | WERE DAMAGED, YET THESE ARE BEING SHOWN | | | ON PLANS.? | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-18 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-18 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2006-06-18 00:00:00 | ****** UNSAT ******** | | | | | | 1) NOTE: PLEASE SEE THE NEW SCOPE PF | | | WORK INCLUDING 277/480V INSTALLATION | | | SHALL BE SIGNED, DATED AND SEALED BY A | | | FL P.E. | | | 471.003(2)(H). | | | | | | 2) NOTE: PLEASE SEE NEW SCOPE OF WORK | | | BEING PROPOSED UNDER THE 2004 FBC. | | | PLEASE SEE CHAPTER 13, | | | 13-415-.1.ABC.1.1, .1.2,1.3. | | | PLEASE PROVIDE THE CORRECT TYPE OF TC AS | | | REQUIRED, PLEASE SUBMIT SCHEDULING, | | | LOCAATION OF ALL REQUIRED OVER -RIDE | | | DEVICES LOCATED A ENTRNACES TO SPACE, AS | | | LIGHTING IS VISABLE TO OCCUPANTS. | | | PLEASE KNOW, DEPENDING ON DEVICE CHOSEN, | | | EITHGER 30 MAX OR 4HRS MAX ALLOWED FOR | | | OVERIDING. | | | PLEASE SEE 13-415.1.ABC.3, | | | 13415.1.AB.1, 13-415.2.ABC.1 | | | PLEASE PROVIDE LIGHTING CALCS/ENERGY | | | CALCS AS REQUIRED ABOVE. | | | | | | ** IMPORTANT** | | | WHEN RESUBMITTING PLANS,PLEASE BE SURE | | | TO COMPLETELY REMOVE ANY OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | ONE COPY OF THE REMOVED OLD/VOIDED | | | SHEETS SHOULD BE SUBMITTED FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-07-11 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-07-11 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-06-19 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-06-19 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED THE SITE | | | DAILY. | | | | | | 3. EXITS ARE TO REMAIN CLEAR AND | | | UNOBSTRUCTED. | | | | | | 4. WRONG LIFE SAFETY CODE NOTED ON PAGE | | | 6 OF 6. SHOULD READ THE FLORIDA FIRE | | | PREVENTION CODE. | | | | | | 5. ENSURE THAT AN EMERGENCY LIGHT | | | FIXTURE IS PRESENT IN THE STORAGE OR | | | EXIT ACCESS TO THE REAR EXIT DOOR. | | | | | | 6. SEPARATE PLANS AND PERMIT REQUIRED | | | FOR FIRE SPRINKLER SYSTEM REMODEL. | | | | | | 7. INTERIOR FINISH ON WALLS AND CEILINGS | | | SHALL MEET APPLICABLE FIRE CODE | | | REQUIREMENTS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-27 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-27 |
Time |
14:50 |
Sent To |
E |
|
| Notes |
| 2006-07-27 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-03 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-03 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2006-07-03 00:00:00 | TO "BOB"#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-21 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-12 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2006-06-16 00:00:00 | TO "BOB"#5 | | 2006-06-12 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-20 |
Time |
15:18 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-06-20 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2006-06-20 00:00:00 | *** PROVISO *** | | | 1) AS PER 2004 FBC(M) 602.2.1, MATERIALS | | | EXPOSED WITHIN PLENUMS SHALL BE NON - | | | COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD | | | INDEX OF NOT MORE THAN 25 AND SMOKE - | | | DEVELOPED INDEX OF NOT MORE THAN 50 WHEN | | | TESTED IN ACCORDANCE WITH ASTM E 84. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-12 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-12 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2006-07-12 00:00:00 | PLANS SHOW NO PLUMBING WORK IS TO BE | | | DONE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-21 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-21 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | DENIED; | | | 1.DRINKING FOUNTAIN REQUIRED BY FBC-2004 | | | PLUMBING TABLE 403.1. DRINKING FOUNTAIN | | | IS SHOWN ON PAGE 1 ONLY. | | | 2.THE D/F SHALL BE 36" TO SPOUT AND A | | | CUP DISPENSOR IS REQUIRED BY FBC-2004 | | | CHAPTER 11 SEC. 11-4.1.3(10) PLEASE NOTE | | | ON PLAN. | | | 3.SHOW ON PLANS THAT RESTROOM IS H/C AND | | | SHOW DETAIL OF HIGHTH OF LAVATORY, W/C, | | | GRAB BARS, ETC PER CHAPTER 11. | | | 4.CORRECT RISER DIAGRAMS TO INCLUDE THE | | | DRINKING FOUNTAIN. | | | 5.PAGE 6 CODE COMPLANCE NOTE SHOULD BE | | | FBC-2004 AND THE 2002 NATIONAL ELECTRIC | | | CODE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|