Plan Review Details - Permit 06060361
Plan Review Stops For Permit 06060361
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-08-08 Cont ID  
Sent By lursu Date 2006-08-08 Time 15:21 Rev Time 0.00
Received By lursu Date 2006-08-08 Time 15:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-08-29 Cont ID  
Sent By mjacobs Date 2007-08-29 Time 09:57 Rev Time 0.00
Received By mjacobs Date 2007-08-29 Time 08:51 Sent To PC
Notes
2007-08-29 09:55:35AS BUILTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-05-29 Cont ID  
Sent By mjacobs Date 2007-05-29 Time 12:45 Rev Time 0.00
Received By mjacobs Date 2007-05-29 Time 12:23 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-10 Cont ID  
Sent By mjacobs Date 2006-08-10 Time 06:49 Rev Time 0.00
Received By mjacobs Date 2006-08-10 Time 06:40 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-29 Cont ID  
Sent By mjacobs Date 2006-07-29 Time 05:37 Rev Time 0.00
Received By mjacobs Date 2006-07-29 Time 05:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-08-22 Cont ID  
Sent By dpalmer Date 2007-08-22 Time 20:05 Rev Time 0.00
Received By dpalmer Date 2007-08-22 Time 19:54 Sent To PC
Notes
2007-08-22 20:05:43REVISED PLANS.
  
 SPACING FOR KITCHEN COUNTER SPACE DOES NOT APPEAR TO
 MEET 210.52C1, THIS IS TO BE VIF.
 NEW ENGINEER OF RECORD.LTRS SUBMITTED.

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2007-08-02 Cont ID  
Sent By dpalmer Date 2007-08-02 Time 07:41 Rev Time 0.00
Received By dpalmer Date 2007-08-02 Time 07:34 Sent To PC
Notes
2007-08-02 07:41:37** UNSAT **
  
 1) NOTE: PLEASE SEE NO LETTER WAS SUBMITTED FROM THE
 DESIGNER/ENGINEER OF RECORD FOR RELEASE OF PROJECT.
 FAC 61G15, FS 471
  
 2) NOTE: PLEASE VERIFY THE FRIG CIRCUIT AS THIS IS
 BEING SHOWN AS #12 AND A 15AMP BREAKER FOR THIS UNIT?
 210.52B1.
  
 ** PLEASE BE SURE TO SUBMIT LETTERS BACK WITH REVISED
 PLANS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-05-14 Cont ID  
Sent By dpalmer Date 2007-05-14 Time 09:19 Rev Time 0.00
Received By dpalmer Date 2007-05-14 Time 08:38 Sent To  
Notes
2007-05-14 09:20:02** UNSAT **
  
 ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA
 BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED
 BY THE CITY OF WEST PALM BEACH.
  
 1) NOTE: PLEASE SEE 210.4 AS THE DISHWASHER AND
 DISPOSAL SEEM TO BE FEEDING THE SAME YOKE WHICH WOULD
 REQUIRE 2-POLE BREAKER.THE BOTH ARE CURRENTLY BEING
 SHOWN AS SINGLE POLE BREAKERS>
 PLEASE ADJUST BREAKER(S) OR PLANS FOR THE DEVICES.
  
 2) NOTE: PLEASE SEE MISSING GFI RECEPTACLES DEVICES FOR
 NEW COUNTER SPACE AREAS PER 210.52C1.
  
 3) NOTE: PLEASE SEE BATH CIRCUIT IS BEING SHOWN WITH
 THE CORRECT CONDUCTOR SIZE OF #12, HOWEVER THE BREAKER
 SIZE IS SHOWN AS 15AMP?
 PLEASE SEE 210.11C3, 210.52D
  
 4) NOTE: PLEASE SEE THE PLANS ARE MISSING THE OUTLET
 FOR RANGE/OVEN.
 FBC 106.1.2
  
 5) NOTE: PLEASE CORRELATE THE LOAD CALCULATIONS WITH
 THE ITEMS ON THE PANEL SCHEDULES. PLEASE SEE THERE ARE
 MANY ITEMS ON CALCS WHICH ARE NOT ON PANEL SCHEDULE?
 NEC 220, 408.4, 310.16, 240.4.
 FBC 106.3.5.4
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-30 Cont ID  
Sent By dpalmer Date 2006-12-30 Time 13:10 Rev Time 0.00
Received By dpalmer Date 2006-12-30 Time 13:06 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-03 Cont ID  
Sent By dpalmer Date 2006-12-03 Time 17:21 Rev Time 0.00
Received By dpalmer Date 2006-12-03 Time 17:18 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-07-31 Cont ID  
Sent By dpalmer Date 2006-07-31 Time 07:14 Rev Time 0.00
Received By dpalmer Date 2006-07-31 Time 07:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-05-29 Cont ID  
Sent By mawillia Date 2007-05-29 Time 09:57 Rev Time 0.00
Received By mawillia Date 2007-05-29 Time 09:50 Sent To  
Notes
2007-05-29 09:56:06*****REVISION APPROVED*****
  
  
 REVISION #3 DATED 05/05/07 TO PLAN SHEET E1 STAMPED,
 INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-08-08 Cont ID  
Sent By mwennerg Date 2006-08-08 Time 11:14 Rev Time 0.00
Received By mwennerg Date 2006-08-08 Time 11:14 Sent To AD
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-08-24 Cont ID  
Sent By adarroug Date 2007-08-24 Time 11:01 Rev Time 0.00
Received By adarroug Date 2007-08-24 Time 11:01 Sent To B
Notes
2007-08-24 11:01:38TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-08-21 Cont ID  
Sent By adarroug Date 2007-08-21 Time 11:29 Rev Time 0.00
Received By adarroug Date 2007-08-21 Time 11:29 Sent To E
Notes
2007-08-21 11:30:06TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-07-28 Cont ID  
Sent By adarroug Date 2007-07-28 Time 16:09 Rev Time 0.00
Received By adarroug Date 2007-07-28 Time 16:08 Sent To E
Notes
2007-07-28 16:09:12TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status P Date 2007-05-11 Cont ID  
Sent By adarroug Date 2007-05-11 Time 15:51 Rev Time 0.00
Received By adarroug Date 2007-05-11 Time 15:51 Sent To  
Notes
2007-05-11 15:51:58TO"BOB"#16

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 10:27 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 10:27 Sent To E
Notes
2006-12-26 10:27:29TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-17 Cont ID  
Sent By adarroug Date 2006-11-17 Time 15:48 Rev Time 0.00
Received By adarroug Date 2006-11-17 Time 15:48 Sent To E
Notes
2006-11-17 15:49:06TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-14 Cont ID  
Sent By adarroug Date 2006-06-14 Time   Rev Time 0.00
Received By adarroug Date 2006-06-14 Time 09:30 Sent To  
Notes
2006-08-22 00:00:00APPLICATION WAS TAKEN OUT BY TONY ON
 6/14/06 AND RETURNED ON 6/27/06 WITH A
 REVISED DESCRIPTION OF WORK
  
2006-07-31 00:00:00TO BOB #1
2006-07-20 00:00:00WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-08-05 Cont ID  
Sent By pschmitz Date 2006-08-05 Time 14:02 Rev Time 0.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-08-05 Cont ID  
Sent By pschmitz Date 2006-08-05 Time 14:01 Rev Time 0.00
Received By pschmitz Date 2006-08-05 Time 14:01 Sent To  
Notes
2006-08-05 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
  
 PROVISO
  
 1) REPLACE EX FIXTURES ONLY
  
 2) REVISION REQUIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692