Plan Review Details - Permit 06060353
Plan Review Stops For Permit 06060353
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-08-08 Cont ID  
Sent By lursu Date 2006-08-08 Time 15:20 Rev Time 0.00
Received By lursu Date 2006-08-08 Time 15:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-07-31 Cont ID  
Sent By mjacobs Date 2007-07-31 Time 07:18 Rev Time 0.00
Received By mjacobs Date 2007-07-31 Time 07:13 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-09 Cont ID  
Sent By mjacobs Date 2006-08-09 Time 18:30 Rev Time 0.00
Received By mjacobs Date 2006-08-09 Time 18:22 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-29 Cont ID  
Sent By mjacobs Date 2006-07-29 Time 05:55 Rev Time 0.00
Received By mjacobs Date 2006-07-29 Time 05:51 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-08-26 Cont ID  
Sent By dpalmer Date 2007-08-26 Time 14:33 Rev Time 0.00
Received By dpalmer Date 2007-08-26 Time 14:28 Sent To PC
Notes
2007-08-26 14:33:21REVISED PLANS.
  
 SPACING FOR KITCHEN COUNTER SPACE DOES NOT APPEAR TO
 MEET 210.52C1, THIS IS TO BE VIF.
 NEW ENGINEER OF RECORD. LTRS SUBMITTED.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-08-12 Cont ID  
Sent By dpalmer Date 2007-08-12 Time 16:08 Rev Time 0.00
Received By dpalmer Date 2007-08-12 Time 16:08 Sent To PC
Notes
2007-08-12 16:11:15 
 * DENIED *
  
 1) NOTE: PLEASE SEE THAT NOW THE REVISED CIRCUTING FOR
 KITCHEN RECEPTABLE IS SHWON CIRCUITED TO THE KITCHEN
 LTS, BATH LTS AND GFI WHICH ARE SUPPOSED TO BE
 EXISTING.
 PLEASE SEE 210.52B1 AS THE KITCHEN AREA RECEPTACLES ARE
 NOT PERMITTED ON THIS SAME CIRCUIT.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-08-02 Cont ID  
Sent By dpalmer Date 2007-08-02 Time 07:32 Rev Time 0.00
Received By dpalmer Date 2007-08-02 Time 07:12 Sent To PC
Notes
2007-08-02 07:32:20*** UNSAT ***
  
 1) NOTE: PLEASE SEE PLANS ONLY INDICATE ONE SMALL
 APPLIANCE CIRCUIT WHEN LOAD CALCULATIONS INDICATE TWO.
 PLEASE ALSO SEE PLANS SHOW THE GFI ON THE COUNTER IN
 THE KITCHEN AS THE LIVING ROOM CIRCUIT FOR
 RECEPTACLES?
 PLEASE SEE THE RECEPTACLE ON KITCHEN WALL WHICH EITHER
 DOES NOT CONTAIN A CIRCUIT OR IS BEING LABELED AS THE
 KITCHEN LIGHTS? PLEASE INDICATE THE CORRECT CIRCUITING
 AS THIS ARE IS REQUIRED TO BE PART OF THE SMALL
 APPLIANCE CIRCUITS.
 PLEASE ADJUST LOAD CALCULATIONS.
 210.52B1, 210.11C1, 220.16
  
  
 ** PLEASE BE SURE TO SUBMIT LETTERS BACK WITH REVISED
 PLANS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-24 Cont ID  
Sent By dpalmer Date 2006-12-24 Time 13:07 Rev Time 0.00
Received By dpalmer Date 2006-12-24 Time 13:00 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-07-31 Cont ID  
Sent By dpalmer Date 2006-07-31 Time 07:24 Rev Time 0.00
Received By dpalmer Date 2006-07-31 Time 07:24 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-08-08 Cont ID  
Sent By mwennerg Date 2006-08-08 Time 11:06 Rev Time 0.00
Received By mwennerg Date 2006-08-08 Time 11:06 Sent To AD
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 09:38 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 09:38 Sent To E
Notes
2007-08-23 09:38:44TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-28 Cont ID  
Sent By adarroug Date 2007-07-28 Time 16:07 Rev Time 0.00
Received By adarroug Date 2007-07-28 Time 16:07 Sent To E
Notes
2007-07-28 16:08:18TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-17 Cont ID  
Sent By adarroug Date 2006-12-17 Time 16:45 Rev Time 0.00
Received By adarroug Date 2006-12-17 Time 16:45 Sent To E
Notes
2006-12-17 16:45:10TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-14 Cont ID  
Sent By adarroug Date 2006-06-14 Time   Rev Time 0.00
Received By adarroug Date 2006-06-14 Time 09:39 Sent To  
Notes
2006-08-22 00:00:00APPLICATION WAS TAKEN OUT BY TONY ON
 6/14/06 AND RETURNED ON 6/27/06 WITH A
 REVISED DESCRIPTION OF WORK
  
2006-07-31 00:00:00TO BOB #1
2006-07-20 00:00:00WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-08-05 Cont ID  
Sent By pschmitz Date 2006-08-05 Time 13:52 Rev Time 0.00
Received By pschmitz Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-08-05 Cont ID  
Sent By pschmitz Date 2006-08-05 Time 13:52 Rev Time 0.00
Received By pschmitz Date 2006-08-05 Time 13:51 Sent To  
Notes
2006-08-05 00:00:00PAUL SCHMITZ
 [email protected]
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC2004 FUEL GAS CODEPLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 AMENDMENTS TO THE FLORIDA BUILDING CODE
  
 CHAPT.1, ADMINISTRATION, 2004 EDITION
  
  
 PROVISO
  
 1) REPLACE EX FIXTURES ONLY
  
 2) REVISION REQUIRED.
  
 END OF COMMENTS, QUESTIONS 561-805-6692