| Plan Review Stops For Permit 06060353 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-08-08 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-08-08 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-31 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-31 |
Time |
07:13 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-08-09 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-08-09 |
Time |
18:22 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2006-07-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-07-29 |
Time |
05:55 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-07-29 |
Time |
05:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-08-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-26 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-26 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2007-08-26 14:33:21 | REVISED PLANS. | | | | | | SPACING FOR KITCHEN COUNTER SPACE DOES NOT APPEAR TO | | | MEET 210.52C1, THIS IS TO BE VIF. | | | NEW ENGINEER OF RECORD. LTRS SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-12 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-12 |
Time |
16:08 |
Sent To |
PC |
|
| Notes |
| 2007-08-12 16:11:15 | | | | * DENIED * | | | | | | 1) NOTE: PLEASE SEE THAT NOW THE REVISED CIRCUTING FOR | | | KITCHEN RECEPTABLE IS SHWON CIRCUITED TO THE KITCHEN | | | LTS, BATH LTS AND GFI WHICH ARE SUPPOSED TO BE | | | EXISTING. | | | PLEASE SEE 210.52B1 AS THE KITCHEN AREA RECEPTACLES ARE | | | NOT PERMITTED ON THIS SAME CIRCUIT. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-02 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-02 |
Time |
07:12 |
Sent To |
PC |
|
| Notes |
| 2007-08-02 07:32:20 | *** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE PLANS ONLY INDICATE ONE SMALL | | | APPLIANCE CIRCUIT WHEN LOAD CALCULATIONS INDICATE TWO. | | | PLEASE ALSO SEE PLANS SHOW THE GFI ON THE COUNTER IN | | | THE KITCHEN AS THE LIVING ROOM CIRCUIT FOR | | | RECEPTACLES? | | | PLEASE SEE THE RECEPTACLE ON KITCHEN WALL WHICH EITHER | | | DOES NOT CONTAIN A CIRCUIT OR IS BEING LABELED AS THE | | | KITCHEN LIGHTS? PLEASE INDICATE THE CORRECT CIRCUITING | | | AS THIS ARE IS REQUIRED TO BE PART OF THE SMALL | | | APPLIANCE CIRCUITS. | | | PLEASE ADJUST LOAD CALCULATIONS. | | | 210.52B1, 210.11C1, 220.16 | | | | | | | | | ** PLEASE BE SURE TO SUBMIT LETTERS BACK WITH REVISED | | | PLANS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-24 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-24 |
Time |
13:00 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-31 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-31 |
Time |
07:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-08 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-08 |
Time |
11:06 |
Sent To |
AD |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-23 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-23 |
Time |
09:38 |
Sent To |
E |
|
| Notes |
| 2007-08-23 09:38:44 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-28 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-28 |
Time |
16:07 |
Sent To |
E |
|
| Notes |
| 2007-07-28 16:08:18 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
16:45 |
Sent To |
E |
|
| Notes |
| 2006-12-17 16:45:10 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-14 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2006-08-22 00:00:00 | APPLICATION WAS TAKEN OUT BY TONY ON | | | 6/14/06 AND RETURNED ON 6/27/06 WITH A | | | REVISED DESCRIPTION OF WORK | | | | | 2006-07-31 00:00:00 | TO BOB #1 | | 2006-07-20 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-08-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-08-05 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2006-08-05 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | | | | PROVISO | | | | | | 1) REPLACE EX FIXTURES ONLY | | | | | | 2) REVISION REQUIRED. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|