| Plan Review Stops For Permit 06060297 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-19 |
Time |
09:52 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-07-19 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2007-07-19 09:46:40 | BUILDING PROVISO; | | | 06060297 2916 S DIXIE HWY. | | | TERRA CON BUILDERS | | | 1) THE ISSUED SET OF PLANS INDICATED A NEW 3'-0" DOOR | | | AND SIDE LITE, TO DATE NO PRODUCT APPROVALS HAVE BEEN | | | SUBMITTED. | | | 2) TEA BAR, THE LETTER DATED 1-26-07 FROM ARCHITECT | | | THEODORE DAVIS STATES THE TEA BAR WILL ONLY BE USED BY | | | EMPLOYEES SEE | | | 11-4.1.1(3)3)AREAS USED ONLY BY EMPLOYEES AS | | | WORK AREAS. AREAS THAT ARE USED ONLY AS WORK AREAS | | | SHALL BE DESIGNED | | | AND CONSTRUCTED SO THAT INDIVIDUALS WITH DISABILITIES | | | CAN APPROACH, ENTER, AND EXIT THE AREAS. THIS CODE DOES | | | NOT REQUIRE THAT | | | ANY AREAS USED ONLY AS WORK AREAS BE CONSTRUCTED TO | | | PERMIT MANEUVERING WITHIN THE WORK AREA OR BE | | | CONSTRUCTED OR EQUIPPED | | | TO BE ACCESSIBLE. | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-15 |
Time |
07:57 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-06-15 |
Time |
07:57 |
Sent To |
|
|
| Notes |
| 2007-06-15 08:02:35 | BUILDING PLAN REVIEW | | | PERMIT: 06060297 | | | ADD: 2916 S DIXIE HWY | | | CONT: TERRA CON CONSTRUCTION | | | TEL: (561)329-7676 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION:REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) PLEASE SEE COMMENT# 7 FROM THE ORIGINAL FIRST REVIEW | | | ABOUT ACCESSIBILITY AND THE FRONT DOOR: | | | 7) EXISTING ENTRY DOORS APPEAR TO BE APPROXIMATELY | | | 2'-0" WIDE.ONE ENTRANCE HAS STAIRS, DOES THE OTHER | | | ENTRANCE HAVE AN ACCESSIBLE ENTRANCE SINGLE DOOR 3'-0" | | | WIDE? | | | 11-4.1.6(2) DUTY TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL TO ALTERED | | | AREAS SHALL BE DEEMED DISPROPORTIONATE | | | TO THE OVERALL ALTERATION WHEN THE COST | | | EXCEEDS 20 % OF THE COST OF THE ALTERA- | | | TION TO THE PRIMARY FUNCTION AREA. | | | (A)(I) AN ACCESSIBLE ENTRANCE | | | (II) AN ACCESSIBLE ROUTE | | | (III) AT LEAST ONE ACCESSIBLE REST- | | | ROOM FOR EACH SEX OR A SINGLE | | | UNISEX RESTROOM | | | (IIII) ACCESSIBLE TELEPHONE | | | (IV) ELEMENTS SUCH AS PARKING, STOR- | | | AGE OR ALARMS. | | | | | | 3) ALSO SEE ISSUED SET OF PLANSFOR ACCESSIBLE COUNTER | | | & BAR SINK . SEE PLUMBING REVIEWER COMMENTS FIRST | | | REVIEW FOR BAR SINK REQUIREMENTS!!!!! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-15 |
Time |
11:04 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-09-15 |
Time |
11:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-24 |
Time |
09:58 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-08-24 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2006-08-24 00:00:00 | PERMIT: 06060297 | | | ADD: 2916 S DIXIE HWY | | | CONT: TERRA CONSTRUCTION | | | TEL: (561)329-7676 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | --- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | FLORIDA BUILDING CODE/ 2004 | | | EXISTING BUILDING CODE/ 2004 | | | CLASSIFICATION OF WORK, | | | LEVEL 1,2 OR 3. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | IS THIS A CHANGE OF OCCUPANCY? | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER | | | SYSTEM IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | | | | OF THE BUILDING PERMIT. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-22 |
Time |
07:09 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-06-22 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 06060297 | | | ADD: 2916 S DIXIE HWY | | | CONT: TERRA CONSTRUCTION | | | TEL: (561)329-7676 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | --- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | FLORIDA BUILDING CODE/ 2004 | | | EXISTING BUILDING CODE/ 2004 | | | CLASSIFICATION OF WORK, | | | LEVEL 1,2 OR 3. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | IS THIS A CHANGE OF OCCUPANCY? | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER | | | SYSTEM IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | | | | OF THE BUILDING PERMIT. | | | | | | 2) SHEET A-1 OVERHEAD DOOR INFILL, PLANS | | | INDICATE THE USE OF 22 GA. STEEL STUDS. | | | THIS GAUGE STUDS ARE FOR INTERIOR USE | | | ONLY. STRUCTURAL GAUGE FRAMING IS 18 | | | GAUGE AND HEAVIER.ASTM C955 LOAD BEARING | | | STEEL STUDS, TABLE 22506.2. | | | | | | 3) SAME DETAIL INDICATES THE USE OF | | | PLYWOOD SHEATHING, SEE 2304.11.2.5 WOOD | | | SIDING. | | | CLEARANCE BETWEEN WOOD SIDING AND EARTH | | | ON THE EXTERIOR OF A BUILDING SHALL NOT | | | BE LESS THAN 6 INCHES (152 MM) EXCEPT | | | WHERE SIDING, SHEATHING AND WALL FRAMING | | | ARE OF NATURALLY DURABLE OR | | | PRESERVATIVE-TREATED WOOD . | | | 2304.9.5 FASTENERS IN PRESERVATIVE | | | TREATED AND FIRE-RETARDANT-TREATED WOOD | | | . FASTENERS FOR PRESERVATIVE TREATED AND | | | FIRE-RETARDANT-TREATED WOOD SHALL BE OF | | | HOT-DIPPED ZINC-COATED GALVANIZED STEEL, | | | STAINLESS STEEL, SILICON BRONZE OR | | | COPPER. FASTENINGS FOR WOOD FOUNDATIONS | | | SHALL BE AS REQUIRED IN AF&PA TECHNICAL | | | REPORT NO. 7. | | | | | | 4) OFFICE DOOR(A) MISSING 18" CLEARENCE | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | 5) UNISEX RESTROOM DOOR:11-4.22.2 DOORS. | | | | | | (1)ALL DOORS TO ACCESSIBLE TOILET | | | ROOMS SHALL COMPLY WITH SECTION 11-4.13 | | | . DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE REQUIRED FOR ANY | | | FIXTURE.11-4.19.3 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE 30 INCHES BY 48 | | | INCHES (760 MM BY 1219 MM) COMPLYING | | | WITH SECTION 11-4.2.4 SHALL BE PROVIDED | | | IN FRONT OF A LAVATORY TO ALLOW FORWARD | | | APPROACH. SUCH CLEAR FLOOR SPACE SHALL | | | ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE | | | AND SHALL EXTEND A MAXIMUM OF 19 INCHES | | | (485 MM) UNDERNEATH THE LAVATORY (SEE | | | FIGURE 11-32 ). | | | | | | 6) SHOWER:11-4.21.7 CURBS. | | | IF PROVIDED, CURBS IN SHOWER STALLS 36 | | | INCHES BY 36 INCHES (915 MM BY 915 MM) | | | SHALL BE NO HIGHER THAN ? INCH (13 MM). | | | SHOWER STALLS THAT ARE 30 INCHES BY 60 | | | INCHES (760 MM BY 1525 MM) MINIMUM SHALL | | | NOT HAVE CURBS. | | | | | | 7) EXISTING ENTRY DOORS APPEAR TO BE | | | APPROXIMATELY 2'-0" WIDE.ONE ENTRANCE | | | HAS STAIRS, DOES THE OTHER ENTRANCE HAVE | | | AN ACCESSIBLE ENTRANCE SINGLE DOOR 3'-0" | | | WIDE? | | | 11-4.1.6(2) DUTY TO PROVIDE AN | | | ACCESSIBLE PATH OF TRAVEL TO ALTERED | | | AREAS SHALL BE DEEMED DISPROPORTIONATE | | | TO THE OVERALL ALTERATION WHEN THE COST | | | EXCEEDS 20 % OF THE COST OF THE ALTERA- | | | TION TO THE PRIMARY FUNCTION AREA. | | | (A)(I) AN ACCESSIBLE ENTRANCE | | | (II) AN ACCESSIBLE ROUTE | | | (III) AT LEAST ONE ACCESSIBLE REST- | | | ROOM FOR EACH SEX OR A SINGLE | | | UNISEX RESTROOM | | | (IIII) ACCESSIBLE TELEPHONE | | | (IV) ELEMENTS SUCH AS PARKING, STOR- | | | AGE OR ALARMS. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
07:39 |
Sent To |
PC |
|
| Notes |
| 2007-08-28 14:37:23 | 2007-08-28 14:37:23 | | | | | | REVISED PLANS AND ENERGY CALCS, UNDER "T" FOR PU, | | | TRIED TO CALL # AS LISTED ON SHEET FOR CONTACT | | | (329-7171) BUT NUMBER IS NOT A WORKING # PER MESSAGE | | | FROM PHONE COMPANY. NEEDS TO PAY FEE OF $60, RECEIPTS | | | ATTACHED. DV PALMER. | | 2007-08-28 07:42:03 | 2007-08-28 07:42:03 | | | | | | **HOLD ** | | | | | | REVISIONS SUBMITTED ON 8/24 WERE WAITING ON NEW REVISED | | | CORRECTED ENERGY CALCULATIONS TO BE BROUGHT IN.SPOKE | | | TO THE PERSON DOING THE ENERGY CALCULATIONS THREE | | | TIMES. | | | AS THESE HAVE NOT BEEN BROUGHT IN THE PLANS ARE BEING | | | PLACED OUTFRONT UNDER "T" (LARGE BINS) ON HOLD. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-13 |
Time |
07:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-13 |
Time |
07:01 |
Sent To |
|
|
| Notes |
| 2007-07-13 07:30:36 | | | | **** UNSAT**** | | | | | | | | | | | | 1) NOTE: PLEASE SEE THE ENERGY CALCULATIONS NEED TO BE | | | *SIGNED* BY THE DESIGNER OR RECORD. PLEASE SEE THE | | | PREPARER IS NOT SIGNED ON SHEETS. | | | 13-103.1.1.1 | | | | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED AS THE | | | INPUT DATA REPORTS DO NOT CORRELATE WITH THE PLANS FOR | | | THE AMOUNT OF FIXTURES, TYPES OF FIXTURES AND WATTAGE | | | OF FIXTURES. | | | PLEASE CORRELATE AND REVISE. | | | | | | 2) NOTE: PLEASE SEE THERE ARE FEES OWED AS THE REVISION | | | WHICH WAS SUBMITTED ON 6/28 HAD 7 SHEETS AND NOT 5 AS | | | INDICATED ON COVER SHEETS. | | | PLEASE ALSO SEE REVISED ENERGY CALCULATIONS ARE NOT | | | CONSIDERED A *SUBMITTAL* AND THE MINIMUM REVISION FEE | | | IS OWED. | | | THE TOTAL OWED FOR THESE REVISIONS ARE $80.00. PLEASE | | | KNOW WHEN SUBMITTING CORRECTED PLANS AND ENERGY | | | CALCULATIONS FEES WILL BE DUE FOR THE NEXT REVIEW | | | ALSO. | | | | | | FBC 108.3 | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-03 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-03 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2007-07-03 13:02:46 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SUBMIT THE REVISED ENERGY CALCULATIONS | | | AS PREVIOUS REQUESTED.THE REVIEW OF THE ENERGY | | | CALCULATIONS AND COORDINATION WITH PLANS CAN NOT BE | | | DONE AT THIS TIME. | | | FBC13-415.1.AB.1.1, 13-415.1.C, 13-415.2 | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-08 |
Time |
20:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-08 |
Time |
20:02 |
Sent To |
|
|
| Notes |
| 2007-06-08 20:21:09 | ** UNSAT* | | | | | | 1) NOTE: PLEASE SUBMIT REVISED ELECTRICAL PLANS SHOWING | | | REVISIONS. PLEASE SUBMIT REVISED PANEL SCHEDULE FOR | | | CIRCUITS TO BE SPECIFIC TO ALL AREAS AND ROOMS IN WHICH | | | THEY FEED. PLEASE SEE 408.4 | | | | | | 2) NOTE: PLEASE COORDINATE ALL ARCHITECTURAL, | | | ELECTRICAL, MECHANICAL AND PLUMBING SHEETS AS PANELS | | | ARE NOT THE SAME ON SHEETS. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE SEE A SHEETS INDICATE A STACKED | | | WASHER/DRYER HOWEVER ELECTRICAL PANEL SCHEDULE | | | INDICATES THESE AS SEPARATE UNITS? | | | PLEASE ADJUST A SHEETS OR ELECTRICAL PLANS AND PANEL | | | SCHEDULE. | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE THE CONDUCTORS FOR EACH AHU IS NOT | | | OF SUFFICIENT SIZE PER 310.16. REQUIRES #6 MINIMUM FOR | | | 60AMP BREAKER. | | | | | | 5) NOTE: PLEASE SEE PLANS SEEM TO SHOW A GUTTER OR | | | J-BOX OUTSIDE, THIS SEEMS TO BE AN OLD CT CAN WHICH IS | | | BEING REQUIRED TO BE REMOVED BASED ON FIELD CONDITIONS | | | AND PICTURES SUBMITTED TO THIS OFFICE FROM THE | | | ELECTRICAL INSPECTOR. | | | PLEASE BE SURE THE ON-SITE WORK IS COORDINATED WITH | | | PLANS. | | | | | | 6) NOTE: PLEASE SUBMIT REVISED ENERGY CALCULATIONS | | | BASED ON FIELD CHANGES. PLEASE SEE 13-415.1.AB.1.1, | | | 13-415.2.ABC.1.2 ETC. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-29 |
Time |
20:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-29 |
Time |
20:11 |
Sent To |
B |
|
| Notes |
| 2006-09-29 00:00:00 | NEW SHEETS SIGNED , DATED AND SEALED BY | | | THE ENGINEER OF RECORD. | | | PLANS SENT BACK TO LUIS'S DESK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-14 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-14 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2006-09-14 00:00:00 | **** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE DUPLICATE PERMIT | | | APPLICATION SUBMITTED IS REQUIRED OT | | | HAVE THE PRINTED NAMES AND SIGNATURES OF | | | THE TWO SUB-CONTRACTORS WHICH WERE | | | ORIGINALLY SIGNED ON. THESE TWO WERE THE | | | MECHANICAL AND ELECTRICAL ONLY. PLEASE | | | SEE THAT NO PLUMBING SUB CONTRACTOR WAS | | | ORIGINALLY SIGNED ON APPLICATION. | | | PLEASE BE SURE ALL LICENSE INFORMATION | | | IS ALSO FILLED OUT ON PERMIT | | | APPLICATION. | | | | | | 2) NOTE: PLEASE SEE THAT THE NEW REVISED | | | ELECTRICAL PLANS ARE NOW SIGNED , DATED | | | AND SEALED BY THE ARCHITECT OF RECORD | | | WHICH IS NOT PERMITTED AS THESE | | | PLANS/DESIGNS WERE DONE BY AN | | | ENGINEERING FIRM. PLEASE BE SURE TO HAVE | | | NEW ELECTRICAL SHEETS SIGNED, DATED AND | | | SEALED BY THE RESPONSIBLE ENGINEER OF | | | RECORD. | | | FS 471.025, FAC 61G15-23.002 | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-16 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-16 |
Time |
07:04 |
Sent To |
|
|
| Notes |
| 2006-08-16 00:00:00 | **** NOTE ***** | | | | | | TEMP IN FAILED STATUS. NO PERMIT | | | APPLICATION IN PACKAGE CALLED AND LEFT | | | CONTRACTOR A MESSAGE FOR APPLICATION TO | | | BE BROUGHT BACK IN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-13 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-13 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2006-06-13 00:00:00 | *************** UNSAT ************* | | | | | | ** PLEASE KNOW, PLANS ARE NOT COMPLETE | | | AT THIS TIME. | | | | | | | | | 1) NOTE: PLEASE SHOW ALL CIRCUITING ON | | | PLANS AND CORRELATE WITH A PANEL | | | SCHEDULE TO BE SUBMITTED. | | | 215.5 | | | | | | 2) NOTE: PLEASE SEE THAT NO PANEL | | | SCHEDULE WAS SUBMITTED SHOWING ALL MIN | | | CIRCUITS, LOADS, CONDUCTOR SIZES ETC. | | | 215.5,408.4, 310.16,240.4 ETC | | | | | | 3) NOTE: PLEASE SUBMIT COMPLETE LOAD | | | CALCULATIONS AND RISER SHOWING THE | | | EXISTING SERVICE, SIZES OF EQQUIPMENT | | | ETC. 220.3,220.10,220.11,220.13, ALL | | | CONTINOUS LOADS @125% PER 215.3,230.42 | | | ETC | | | 215.5.240.4.310.16 ETC. | | | | | | 4) NOTE: PLEASE SEE 700.12E FOR | | | CIRCUTING OF ALL EM/ EXT LTS. | | | | | | 5) NOTE: PLEASE INDICATE NEW OR EXISTING | | | SIGN CIRCUIT REQUIRED PER 600.5 | | | | | | 6) NOTE: PLEASE SEE BUILDING SEEMS TO BE | | | PART OF A LARGER STRUCTURE. IF THE | | | BUILDING IS LARGER THAN 5000 SA FT OVER | | | ALL, THEN PLEASE SEE FBC CHAPTER | | | 13,13-415.1.ABC.1.1, .1.2,.1.3. | | | PLEASE PROVIDE LIGHTING CONTROLS WHICH | | | ARE REQUIRED UNDER THE NEW FLORIDA | | | ENERGY CODE. | | | | | | 7) NOTE: PLEASE SEE PANEL AS SHOWN ON | | | PLANS DOES NOT MEET 110.26,240.24. | | | PLEASE ADJUST. | | | | | | 8) NOTE: PLEASE SEE LOCATION OF WATER | | | HEATER DOES NOT MIN CLEARENCES PER | | | 422.17 | | | PLEASE ADJUST. | | | | | | 9) NOTE: PLEASE SEE POSSIBLE NOTES FROM | | | BUILDING REVIEW FOR VALUATION OF PROJECT | | | PER FBC 108.3 ADMINISTRATIVE SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 10) NOTE: PLEASE SEE THE OWNER AS SIGNED | | | ON NOTICE OF COMMENCEMENT IS DIFFERENT | | | THAN THE OWNER AS LISTED IN OUR SYSTEM | | | AND THE PROPERTY APPRAISER'S OFFICE. | | | PLEASE PROVIDE DOCUMENTS FOR NEW | | | OWNERSHIP. | | | FS 713.13 | | | | | | 11) NOTE: PLEASE SEE THAT THE CODES IN | | | EFFECT SHALL BE STATED ON PLANS. 106.1.2 | | | PLEASE SEE PLANS SHALL INCLUDE AT A MIN | | | 2004 FBC, NFPA-72 2002 , NFPA-101 2003, | | | NFPA-70 2002 . | | | PLEASE SEE OTHER CODES MAY BE REQUESTED | | | BY OTHER REVIEWER(S). | | | | | | 12) NOTE: PLEASE VERIFY WHAT TYPE OF | | | EGRESS LIGHTING IS PROVIDED TO THE | | | PUBLIC RIGHT OF WAY PER LS101 7.8,7.9 | | | NO LIGHTING INDICATED AT THIS TIME. | | | | | | ** PLEASE KNOW, PLANS MAY HAVE FURTHER | | | COMMENTS AS PLANS WERE NOT COMPLETE AT | | | THIS TIME. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-22 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-22 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2007-06-22 10:56:41 | *****PROVISO***** | | | | | | | | | THE APPROPIATE REVISED PLAN SHEET(S) TO BE FIRE-STAMPED | | | WHEN OTHER REVIEWERS HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-09-15 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-15 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | *****APPROVED***** | | | | | | | | | | | | | | | FIRE PLAN REVIEW COMMENTS OF 08/24/2006 | | | HAVE BEEN ADDRESSED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-08-24 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-08-24 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2006-08-24 00:00:00 | **UNSAT** | | | | | | | | | | | | 1.) FIRE REVIEW OF 6/19/2006 NOTE #3 HAS | | | NOT BEEN ADDRESSED. PLEASE INDICATE | | | INTERIOR FINISH FOR WALLS AND CEILING | | | (CLASS A OR B) IN THE MEANS OF EGRESS | | | AREAS. | | | | | | 2.)PLEASE INDICATE WHY THERE IF NOT AN | | | EXIT SIGN LIGHT AT THE EXISTING DOOR | | | LEADING FROM YOGA STUDIO (PG E1.1 NEAR | | | A-31). | | | | | | ALL OTHER NOTES AND(OR) CONCERNS OF | | | 06/19/2006 FIRE REVIEW HAVE BEEN | | | ACKNOWLEDGED/ADDRESSED.THANK YOU | | | | | | | | | | | | | | | | | | | | | LT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-06-19 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-06-19 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. ONLY ONE EXIT SIGN COULD BE LOCATED | | | ON PAGE A-4. PLEASE REVISE PLANS AS | | | NECESSARY. | | | | | | 3. PLEASE INDICATE INTERIOR FINISH FOR | | | WALLS AND CEILINGS. CLASS A OR B IS | | | REQUIRED IN MEANS OF EGRESS AREAS. | | | | | | 4. NO PORTABLE FIRE EXTINGUISHERS | | | ILLUSTRATED ON THE PLANS. PLEASE DISPLAY | | | THESE EXISTING OR NEW DEVICES. | | | | | | 5. PLEASE INDICATE EXISTING DOOR | | | HARDWARE INCLUDING LOCKING DEVICES SO A | | | DETERMINATION CAN BE MADE IF THEY MEET | | | CODE. | | | | | | 6. DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 7. EXITS SHALL REMAIN CLEAR AND | | | UNOBSTRUCTED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-06 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-06 |
Time |
14:36 |
Sent To |
E |
|
| Notes |
| 2007-07-06 14:36:27 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-29 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-29 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2007-07-03 08:20:57 | TO "BOB"#12 | | 2007-06-29 13:11:05 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-26 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-26 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2007-06-29 11:57:30 | TO "BOB"#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-04 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-04 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2007-06-04 10:00:54 | TO "BOB"#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-06 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-06 |
Time |
17:21 |
Sent To |
M |
|
| Notes |
| 2007-04-06 17:21:51 | TO TOM GORDON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-27 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-27 |
Time |
18:35 |
Sent To |
M |
|
| Notes |
| 2007-03-27 18:35:45 | TO MECH BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-13 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-13 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2006-09-13 00:00:00 | TO "BOB"#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-11 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-11 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | TO "BOB"#7 | | 2006-08-02 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-02 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-02 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2006-08-02 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-22 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-06-07 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2006-06-07 00:00:00 | TO "BOB"#17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-13 |
Time |
15:32 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-13 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2007-07-13 15:45:55 | *** REVISION DENIED *** | | | 1) REVISED COOLING LOAD CALCULATIONS ARE CALLING FOR | | | A/C SYSTEM #2 TO BE A 2 TON, REVISED MECHANICAL PLANS | | | ARE CALLING FOR A/C SYSTEM #2 TO BE A 3 TON. THE TWO | | | MUST COINCIDE , PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
N |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-12 |
Time |
08:48 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-06-12 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2007-06-12 08:48:45 | NO MECHANICAL CHANGES TO PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-09 |
Time |
08:14 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-04-09 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2007-04-09 08:15:12 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-29 |
Time |
14:03 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-29 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2007-03-29 14:03:39 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-15 |
Time |
11:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-15 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-09-15 00:00:00 | *** PROVISO *** | | | 1) CLOTHES DRYER VENT MUST TERMINATE A | | | MINIMUM OF 4 FT. FROM DOOR AND 10 FT. | | | FROM FRESH AIR INLETS. PER 2004 FBC/M | | | 401.5.1 AND 501.2 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-17 |
Time |
11:52 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-08-17 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 6-19-06 | | | NOTE #2, PLEASE PROVIDE FRESH AIR | | | CALCULATIONS, SEE 2004 FBC/M 403.3. | | | 20 CFM PER OCCUPANT IS NOT A | | | CALCULATION. PLEASE ALSO SHOW HOW MANY | | | CFM'S. ARE TO GO TO EACH AHU SO AIR | | | BALANCING MAY BE DONE PROPERLY. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-06-19 |
Time |
09:24 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-06-19 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2006-06-19 00:00:00 | *** DENIED *** | | | 1) PLEASE SHOW SIZE OF MAIN TRUNK LINES, | | | SUPPLY & RETURN. | | | | | | 2) PLEASE PROVIDE FRESH AIR & FRESH AIR | | | CALCULATIONS, PER 2004 FBC/M 401.2 . | | | | | | 3) PLEASE SHOW JOB ADDRESS ON MECHANICAL | | | PLANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-16 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-16 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2007-07-16 11:17:21 | DENIED; | | | THE BAR SINK IS REQUIRED TO MEET THE FLORIDA | | | ACCESSIBILITY CODE SECTIONS 11-4.24.2 THRU 11-4.24.7. | | | SHOW THE DETAIL DELETED FROM APPROVED PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2007-06-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-15 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-15 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2007-06-15 09:12:04 | REVISION DENIED; | | | 1. PLEASE CLOUD AND LIST REVISED SECTIONS. | | | 2. HEIGHT OF BAR SINK TO BE 34" TO TOP MAX. FBC-2004 | | | BUILDING SECTION 11-4.24.2. PLEASE SHOW DETAIL THAT WAS | | | DELETED FROM APPROVED PLANS. | | | 3. PAGE P-2 IS MISSING. ALL ACCESSIBLITY CODES WILL BE | | | CHECKED AT FINAL INSPECTION. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-10-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-02 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-02 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-09-23 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-09-23 |
Time |
12:23 |
Sent To |
|
|
| Notes |
| 2006-09-23 00:00:00 | DENIED; | | | 1.LAVATORY DETAIL ON PAGE P-2 IS | | | CORRECT. A WALLHUNG SINK. PAGE P-1 | | | (PLUMBING FIXTURE SCHEDULE) LAV IS SPECT | | | OUT AS A CABINET MTD. CHANGE FIXTURE | | | SCHEDULE. | | | 2.PAGE A-1 BAR SINK DETAIL DOES NOT MEET | | | HANDICAP REQUIREMENTS AND REQUIRES A | | | FRONT VIEW SHOWING THE OPEN FRONT FOR | | | KNEE CLEARANCE. SECTION 11-4.24.2 HEIGHT | | | OF SINK TO BE 34"'S NOT 36"'S AS | | | SHOWN.MAXIMUM DEPTH OF SINK IS 6 1/2"'S | | | NOT 9"'S SEE SECTION 11-4.24.4 | | | | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-08-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-12 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-12 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2006-08-12 00:00:00 | DENIED; | | | 1.(SECOND REQUEST) WATER RISER REQUIRED. | | | SIZE ALL PIPES. WATER HAMMER ARRESTORES | | | REQUIRED AT AUTOMATIC CLOTHES WASHER AND | | | BAR SINK. PLEASE SPEC OUT TYPE TO BE | | | USED. | | | 2.SHOWER MISSING FROM SANITARY RISER | | | DIAGRAM. | | | 3.(SECOND REQUEST) LIST ON PLANS | | | COMPLIANC TO FBC-2004 PLUMBING TABLE | | | 403.1, NOT ON RESONCE SHEET. TYPE OF | | | BUSINESS, SQ. FT. AND NUMBER OF PEOPLE | | | TO OCCUPY UNIT. | | | 4.(SECOND REQUEST) SHOW DETAIL DRAWINGS | | | OF HANDICAP FIXTURES. | | | A)SHOWER; NO CURB OR DOOR PERMITED | | | .SHOW LOCATION OF SHOWER VALVE AND | | | LOCATION OF AJUSTABLE SHOWER HEAD. | | | B)BATHROOM LAYOUT NEEDS TO BE | | | CHANGED. THE WATER CLOSET SHOULD BE 18" | | | OF THE WALL WITH GRAB BARS IN BACK AND | | | ON THE SIDE AS REQUIRED. THE LAVATORY | | | SHOULD BE IN THE MIDDLE 60" FROM TOILET | | | WALL TO EDGE OF LAVATORY. SEE HANDICAP | | | CODE FIGURE 30E. | | | C)DOOR SWING ON P-1 HAS NOT BEEN | | | CHANGED TO SWING OUT. ALSO DOOR SHOULD | | | BE LOCATED DIAGONAL TO THE TOILET. | | | D)SHOW DETAIL OF BAR SINK. CABINET | | | TO BE OPEN FRONT FOR FRONTAL APPROACH. | | | SHOW SIZE AND LOCATION OF WATER | | | PURIFIER, CANNOT INTERFER WITH KNEE | | | CLEARANCE UNDER BAR SINK. | | | E)SHOW HEIGHT REQUIREMENT OF | | | DRINKING FOUNTAIN, 36" TO SPOUT. | | | F)DRESSING ROOM IS REQUIRED TO HAVE | | | A FIXED SEAT SEE SECTIONS 11-4.35.4 AND | | | 11-4.35.5. SHOW IN DETAIL. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-06-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-14 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-14 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2006-06-14 00:00:00 | DENIED; | | | 1.ADD NOTE TO PAGE A-2; "IN THE REMOVAL | | | OF ANY PART OF A DRAINAGE SYSTEM DEAD | | | ENDS ARE NOT PERMITED. DEMO PLUMBING | | | INSPECTION REQUIRED". | | | 2.SANITARY AND WATER RISERS DIAGRAMS | | | REQUIRED ON DRAWING PER FBC-2004 CHAPTER | | | 1 SEC. 106.3.5.1.3. PLEASE SIZE ALL | | | PIPES. | | | 3.MINIMUM PLUMBING FIXTURES; SHOW | | | COMPIANCE ON PLANS TO MINIMUM PLUMBING | | | FIXTURES REQUIRED PER. TABLE 403.1. LIST | | | ON PLANS. | | | 4.AUTOMATIC CLOTHES WASHER DRAIN | | | REQUIRED TO BE 3" SEC. 406.3 WITH A | | | CLEANOUT OT 48" ABOVE FINISH FLOOR. | | | 5.SHOW DETAILS ON PLANS OF HANDICAP | | | REQUIREMENTS AS LISTED BELOW; | | | A.BATHROOM DIMENSIONS AND SHOW CLEAR | | | FLOOR SPACE OF FIXTURES. | | | B. SHOWER STALL REQUIRED TO MEET ALL | | | REQUIREMENTS OF CHAPTER 11 SEC 11-4.21.1 | | | THRU 11-4.21.8. | | | C.LACATORY SEC. 11-4.19.1 THRU | | | 11-4.19.6. | | | D.TOILET SEC.11-4.16.1 THRU 11-4.16.6. | | | E.GRAB BARS SEC. 11-4.17.6. | | | F. DOOR SWING INTO CLEAR FLOOR SPACE | | | SEC.11-4.17.5 | | | G.DRESSING ROOM SEC. 11-4.35.2 THRU | | | 11-4.35.5. | | | 6.MEANS OF THERMAL EXPANSION REQUIRED | | | PLUMBING CODE SEC. 607.3. SHOW ON PLANS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|