Plan Review Details - Permit 06060067
Plan Review Stops For Permit 06060067
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-13 Cont ID  
Sent By jwitmer Date 2006-07-13 Time 13:37 Rev Time 1.22
Received By jwitmer Date 2006-07-13 Time 13:37 Sent To PC
Notes
2006-07-13 00:00:00PERMIT: 06060067
 ADD: 400 N FLAGLER #804
 CONT: WILDES BUILDERS
 TEL: (772)260-8630
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
  
 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING
 UNIT AND A PUBLIC OR SERVICE AREA WITHIN
 THE STRUCTURE SHALL HAVE AN IMPACT
 INSULATION CLASS (IIC) RATING OF NOT
 LESS THAN 50 (45 IF FIELD TESTED) WHEN
 TESTED IN ACCORDANCE WITH ASTM E 492.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-23 Cont ID  
Sent By jwitmer Date 2006-06-23 Time 14:00 Rev Time 0.00
Received By jwitmer Date 2006-06-23 Time 14:00 Sent To  
Notes
2006-06-23 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06060067
 ADD: 400 N FLAGLER #804
 CONT: WILDES BUILDERS
 TEL: (772)260-8630
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A1 INDICATES THIS TO BE A
 TYPE IA BUILDING SPRINKLERS REQUIRED.
 THIS BUILDING IS NOT FIRE SPRINKLERED.
  
 2) CODES TO BE DESIGNED AND REVIEWED BY
 ARE THE :
 2004 FLORIDA BUILDING CODE
 2004 EXISTING BUILDING CODE
 CLASSIFICATION OF WORK:
 LEVEL I
 LEVEL 2
  
 3) SOUND TRANSMITION:
 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING
 ASSEMBLIES SEPARATING DWELLING UNITS
 FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND
 TRANSMISSION CLASS (STC) OF NOT LESS
 THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN
 ACCORDANCE WITH ASTM E 90. PENETRATIONS
 OR OPENINGS IN CONSTRUCTION ASSEMBLIES
 FOR PIPING; ELECTRICAL DEVICES; RECESSED
 CABINETS; BATHTUBS; SOFFITS; OR HEATING,
 VENTILATING OR EXHAUST DUCTS SHALL BE
 SEALED, LINED, INSULATED OR OTHERWISE
 TREATED TO MAINTAIN THE REQUIRED
 RATINGS. THIS REQUIREMENT SHALL NOT
 APPLY TO DWELLING UNIT ENTRANCE DOORS;
 HOWEVER, SUCH DOORS SHALL BE TIGHT
 FITTING TO THE FRAME AND SILL.
  
 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING
 UNIT AND A PUBLIC OR SERVICE AREA WITHIN
 THE STRUCTURE SHALL HAVE AN IMPACT
 INSULATION CLASS (IIC) RATING OF NOT
 LESS THAN 50 (45 IF FIELD TESTED) WHEN
 TESTED IN ACCORDANCE WITH ASTM E 492.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-09-17 Cont ID  
Sent By dpalmer Date 2006-09-17 Time 11:25 Rev Time 0.00
Received By dpalmer Date 2006-09-17 Time 11:15 Sent To PC
Notes
2006-09-17 00:00:00REV OK,
  
 NOTES FROM PREVIOUS PLANS STILL BE
 VERIFIED IN FIELD.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-06-23 Cont ID  
Sent By dpalmer Date 2006-06-23 Time 10:41 Rev Time 0.00
Received By dpalmer Date 2006-06-23 Time 10:41 Sent To I
Notes
2006-06-23 00:00:00REDLINED.
  
 VERIFY 2-MIN SMALL APPL CIRCUITS,
 210.11C1,210.52B1, 220.16
 VERIFY BATH DEDICATED CIRCUIT(S). 20A
 #12, 210.11C3, 210.52D

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-06-23 Cont ID  
Sent By mwennerg Date 2006-06-23 Time 15:05 Rev Time 0.00
Received By mwennerg Date 2006-06-23 Time 15:05 Sent To  
Notes
2006-06-23 00:00:00PLEASE SEE BUILDING REVIEW COMMENT (1).

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 17:54 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 17:54 Sent To E
Notes
2006-09-09 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-05 Cont ID  
Sent By adarroug Date 2006-07-05 Time 10:21 Rev Time 0.00
Received By adarroug Date 2006-07-05 Time 10:21 Sent To B
Notes
2006-07-05 00:00:00TO "JWITMER' DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-24 Cont ID  
Sent By adarroug Date 2006-06-24 Time 10:20 Rev Time 0.00
Received By adarroug Date 2006-06-15 Time 14:19 Sent To  
Notes
2006-06-15 00:00:006/15/06-TO "BOB"#2
2006-06-14 00:00:00PRE-INSPECT TAKEN FROM KEN CONRAD'S
 DESK..ROUTED TO INCOMING..CONTRACTOR
 CHGD SCOPE OF WORK, ADDED PLANS, &
 INCREASED CONTRACT VALUE

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-06-24 Cont ID  
Sent By pschmitz Date 2006-06-24 Time 13:38 Rev Time 0.00
Received By pschmitz Date 2006-06-24 Time 13:38 Sent To  
Notes
2006-06-24 00:00:00REPLACE EXISTING FIXTURES.